TNC Style Connector TNC Series FEATURE ・ TNC series is a thread coupling coaxial connector which is modified BNC style Characteristic Impedance connector. 50 Ω ・ Due to the thread coupling, it is superior to BNC style connector in vibration load. Frequency Range ・ Other electrical and mechanical characteristics are same as BNC style connector. DC to 2GHz ・ Recommended toque of coupling is 45 ∼ 68.6N・cm. Lock Type Screw CONFORMING STANDARD MIL-C-39012 SPECIFICATIONS Characteristic Impedance 50 Ω Dielectric Withstanding Voltage 500V AC(r.m.s) / 1 minute Insulation Resistance 1,000M Ω min. at 500V DC Contact Resistance 3m Ω max. V.S.W.R. 1.3 max. (DC ∼ 2GHz) * The specifications are typical but may not apply to all connectors. Please check the specifications on each item with its drawing from us when you use. RoHS MATERIAL/FINISH Compliant Compliant Item Material / Finish Shell Copper Alloy / Ni or Ag Plating Contact (Female) Copper Alloy / Ag or Au Plating Contact (Male) Copper Alloy /Ag or Au Plating Insulator PTFE Gasket Silicon Rubber ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. 110526 http://www.ddknet.co.jp TNC Series Unit:mm ○ Straight Cable Plug Clamp Type Part Number Finish Center L Outer Applicable Cable Assembly Instruction Conductor Conductor 3D-2V TNC-P-3-CF 3D-QEV 25.0 Ag Ag 6 L Crimp Type Part Number Applicable Cable φA L Outer Finish Center Assembly Crimp Instruction Tool φA Conductor Conductor TNC-P-1.5DQEW-CF L TNC-P-2.5D2W-CR10-CF TNC-P-3D2W-CR10-CF φA Part Number 1.5D-2W 1.5D-QEW 2.5D-2W 2.5D-QEW 3D-2W 3D-QEW 5.5 22.3 Ni Au 1 CR-H-1100 6.3 24.3 Ni Ag 2 CR-H-1115 7.9 24.3 Ni Ag 2 CR-H-1135 Applicable Cable φA L Outer Finish Center Assembly Crimp Tool Instruction Conductor Conductor TNC-P-2DFB-1-CF 2D-FB 6.2 29.7 Ni L ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 2 Au 3 CR-H-1105 TNC Series Unit:mm ○ Straight Cable Jack φB φA Crimp Type Part Number Applicable Cable TNC-J-1.5DXW-CR10-120-CF 2D-FB φA φB Finish Center L Outer Assembly Crimp Tool Instruction Conductor Conductor 2.5D-2W TNC-J-2.5D2W-CR10-CF 2.5D-QEW L Applicable Cable Part Number 5.5 12.0 26.8 Ni Ag 4 CR-H-1142 6.25 14.6 25.0 Ni Ag 4 CR-H-1105 φA φB Finish Center L Outer Assembly Crimp Tool Instruction φB φA Conductor Conductor 3D-2W TNC-J-3D2W-CR10-CF 7.9 14.6 25.42 3D-QEW Ni Ag 4 CR-H-1135 5.0 17.0 L ○ Straight Bulkhead Cable Jack Applicable Part Number Cable 2.5D-2W TNC-BJ-2.5D-QEW-CF 2.5D-QEW φA φB L Outer Finish Center Assembly Crimp Tool Instruction Conductor Conductor 14.0 6.25 27.9 Ni Ag 4 CR-H-1105 ※ Mounting Panel Thickness:2.7mm max. +0.1 13 φ11.2 0 φA φB (Flat Diameter) 2 16.8 L +0.1 0 10.2 10.4 (Detent Diameter) Panel Mounting Dimensions ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 3 TNC Series Unit:mm ○ Straight Panel Cable Jack Crimp Type Applicable Part Number Cable Ni 1.5D-2W Ag 5 CR-H-1142 4-φ3.0 4-φ3.0 12.7 12.7 φ5.5 Assembly Crimp Tool Instruction Conductor Conductor 1.5D-QEW TNC-PJ-1.5DQEW-CR10-CF Finish Center Outer φ12.0 15.8 2.3 12.7 □17.5 26.8 12.7 Panel Mounting Dimensions Applicable Part Number Cable TNC-PJ-1.5DXW-CR10-M-CF Finish Center Outer Assembly Crimp Tool Instruction Conductor Conductor 1.5D-XW Ni 1.5D-XWTA Ag 7 CR-H-1100 +0.1 4-φ3.0 0 0.05 18.2 18.2 φ5.5 4-M2.5 0.45 +0.1 φ12.0 0 15.8 2.3 30.8 18.2 18.2 □25.4 0.05 Panel Mounting Dimensions Applicable Part Number Cable TNC-PJ-2H-1.5D-CR10-CF 1.5D-QEV 1.5D-2V Outer Finish Center Assembly Crimp Tool Instruction Conductor Conductor Ni 2-φ3.2 Ag 5 18.0 23.4 18.0 φ4 2-φ3.2 φ6.0 2.3 14.7 24.4 12 Panel Mounting Dimensions ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 4 CR-H-1101 TNC Series Unit:mm ○ Receptacle Jack Finish Outer Center Conductor Conductor TNC-R-CF Ag Au TNC-R-NiAu-CF Ni Au Part Number 4-M2.6 0.45 0.15 12.7 12.7 0.05 φ1.4 4-φ2.8 +0.2 0 φ11.1 2.3 15.8 12.7 26.3 □17.5 12.7 0.05 Panel Mounting Dimensions Finish Outer Center Conductor Conductor TNC-R2-CF Ag Ag TNC-R2-Ni-CF Ni Ag TNC-R2-NiAu-CF Ni Au Part Number +0.1 4-φ3.0 12.7 12.7 0.05 φ1.4 4-φ3.0 0 +0.2 0 φ11.1 2.3 15.8 12.7 □17.5 26.3 12.7 0.05 Panel Mounting Dimensions Finish Outer Center Conductor Conductor Ni Ag Part Number TNC-R2-2H-Ni-CF 0.05 18 23.3 18 φ1.4 2-φ3.0 +0.1 φ9.0 0 2.3 15.8 26.3 11 2-φ3 +0.1 0 Panel Mounting Dimensions ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 5 TNC Series Unit:mm ○ Receptacle Jack Finish Outer Center Conductor Conductor Ni Au Part Number TNC-SR-3-CF +0.1 4-φ3.0 0 0.05 12.7 φ5.4 12.7 φ1.7 4-φ3.0 +0.1 0 φ12 4 2.3 9.6 15.8 12.7 27.7 12.7 □17.5 0.05 Panel Mounting Dimensions Finish Outer Center Conductor Conductor Ni Au Part Number TNC-SR-6-CF +0.1 4-φ3.1 0 12.7 12.7 0.05 φ4.0 0 φ1.27-0.1 4-φ3.0 (Thru-Hole) +0.1 0 φ4.1 2 6.8 17.8 2 12.7 26.6 12.7 0.05 □17.5 Panel Mounting Dimensions Finish Outer Center Conductor Conductor Ni Au Part Number 4-φ3.0 (Thru-Hole) +0.1 4-φ3.1 0 12.7 0.05 12.7 φ4.0 0 φ1.27-0.1 TNC-SR-9-CF +0.1 0 φ4.1 12.7 2 8.5 17.8 2 □17.5 12.7 26.6 0.05 Panel Mounting Dimensions ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 6 TNC Series Unit:mm ○ Receptacle Plug Finish Outer Center Conductor Conductor Ag Ag Part Number TNC-PR-CF +0.1 4-φ3.2 0 12.7 0.05 12.7 φ14.6 φ1.1 φ2.29 4-φ3.0 +0.1 φ9.0 0 18.0 2.3 12.7 28.5 □17.5 12.7 0.05 Panel Mounting Dimensions ○ Right Angle Receptacle Jack Finish Outer Center Conductor Conductor Part Number TNC-LR-CF Ag Au TNC-LR-Ni-CF Ni Ag 23 0.05 12.7 23 12.7 φ2.29 φ1.1 2.3 □17.5 14.3 +0.1 0 4-φ3 12.7 +0.1 φ9.0 0 4-φ3.0 12.7 0.05 Panel Mounting Dimensions Finish Part Number TNC-LR-1-CF 21.6 4-M2.6 5 23.1 12.7 φ2.29 14.3 2.3 12.7 □17.5 ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 7 Outer Center Conductor Conductor Ag Ag TNC Series Unit:mm ○ Dust Cap 7/16-28UNEF-2B Part Number (φ14.5) (φ3.5) Finish TNC-RC-1 Ni TNC-RC-1-D1 Ag (60) (75) (φ14.5) 7/16-28UNEF-2B Part Number TNC-C-2-CF Ni TNC-C-2-D1-CF Ag 15 ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 8 Finish TNC Series Unit:mm ○ Assembly Instruction(1) Parts Configulration Sleeve Heat-shrinkable tube Contact Body Insulator Ferule Cable length which require for the cable assembly. L=L1-3.3 L=L2+19.7 Cable length L L2 L1 ① 14.7 Sheath ② ① Insert the heat-shrinkable tube onto the cable. Cut the cable as fig.1. Please be careful to not damage the outer conductor. Outer Conductor Heat-shrinkable tube 0.5 ② Insert the ferule on the outer conductor and spread the top of the outer conductor. Insulator Insert the sleeve between insulator and outer conductor. And cut the outer conductor along the sleeve. Sleeve Ferule ③ ③ Cut the insulator as fig. 3. Insulator Outer Conductor Please be careful to not damage the center conductor. Pre-solder the center conductor and cut the center conductor. Please be careful to not damage the insulator by soldering. Insert the insulator as fig.3. Center Conductor (Pre-soldering) 0 +0.2 4 -0.3 6.2 -0.5 Insulator ④ ④ Solder up the contact with center conductor. No gap between insulator and contact. Soldering No gap Contact ⑤ Insert the body into the above cable assembly. And crimp the root of the body. Please be careful to meet the crimp height as follows. 5.33∼5.84 ⑤ (between body and contact) B (3.1) Dies A C A Measuring point Note)Distance between body and contact must be met. ⑥ ⑥ Cover the heat-shrinkable tube on the root of the body and heat up. Heat-shrinkable tube ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 9 TNC Series Unit:mm ○ Assembly Instruction(2) Parts Configulration Boot Ferule ① Cable Contact Sleeve ① Insert the boot into the cable and cut the cable as fig.1. 14 Boot Body Please be careful to not damage the outer conductor. Outer Con Sheath Ferule ② Insert the ferule on the outer conductor and spread the top of the outer conductor. Press-in rhe sleeve between insulator and outer conductor. ② Sleeve Cut the extra outer conductor along the sleeve. Outer Conductor ③ Cut the insulator and center conductor as fig.3. Center Conductor ③ A Part Number B ④ Crimp Tool 4.0mm TNC-P-3D2W-CR10-CF 5.5mm 3.5mm Crimp the contact (match the side hole of contact with the curve of crimping hole of tool.) Center Conductor No gap Crimping Dies ⑤ B 5.0mm ④ Pinch the contact in the crimping hole(center hole) and insert the center conductor of the cable. Insulator Tool Surface A TNC-P-2.5D2W-CR10-CF Part Number Contact Crimp Tool TNC-P-2.5D2W-CR10-CF CR-H-1115 TNC-P-3D2W-CR10-CF CR-H-1135 Contact crimped Crimp Tool ⑤ Insert the above contact into the body. Match the key in the insulator and keyway of the contact. Body Crimp the root of body as fig.5. Cover the boot on the root of the connector body. Body Surface Boot ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 10 TNC Series Unit:mm ○ Assembly Instruction(3) Parts Configulration Sleeve Boot ① Boot Contact assembly Sleeve Body ① Insert the boot and sleeve into the cable and cut the cable as fig.1. Please be careful to not damage the outer conductor. 19 Outer Conductor Sheath Cable 7 10 4 ② 4 ② Cut the cable as fig.2. Cut the center conductor after pre-soldering. Outer Conductor Aluminum foil tape ③ Insulator Cente Conductor (Cut off afterpre-soldering) ③ Insert the contact between outer conductor and aluminum foil tape. Solder the contact with center conductor. When the solder is stick out, please shave the extra solder along the contact. Soldering Contact assembly 1 ④ Cover the sleeve on the outer conductor and crimp as fig.4. Crimp Tool : (CR-H-1105) ④ Sleeve ⑤ ⑤ Insert the above contact into the body and screw. Cover the boot on the root of the body. Boot Body ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 11 TNC Series Unit:mm ○ Assembly Instruction(4) Parts Configulration Heat-shrinkable tube Ferule Insulator Sleeve Sheath Body ① Insert the heat-shrinkable tube into the cable and cut the cable as fig.1. Please be careful to not damage the outer conductor. ① Heat-shrinkable tube Contact Outer Conductor Part Number Cable A ② Outer Conductor Ferule TNC-J-1.5DXW-CR10-120-CF 13.0mm TNC-J-2.5D2W-CR10-CF 11.0mm TNC-J-3D2W-CR10-CF 11.5mm TNC-BJ-2.5DQEW-CF 13.0mm Sleeve ② Insert the ferule on the outer conductor and spread the top of the outer conductor. Press in the sleeve between outer conductor and insulator. ③ Cut off the extra outer conductor along the sleeve. Spread the top ③ Cut the cable as fig.3. Cut the center conductor after pre-soldering. Please be careful to not damage the center conductor. Insulator Sleeve Center Conductor (Pre-soldering) Outer Conductor B ● Part Number C TNC-J-1.5DXW-CR10-120-CF ④ A Insulator Soldering Contact B C 5.7mm 2.8mm TNC-J-2.5D2W-CR10-CF 3.0mm 2.5mm TNC-J-3D2W-CR10-CF 3.1mm 2.5mm TNC-BJ-2.5DQEW-CF 6.0mm 2.0mm ④ Insert the insulator and solder the contact with center conductor. When the solder is stick out, please shave the extra solder along the contact. No gap ⑤ ⑤ Insert the above contact into the body. Match the key in the insulator and keyway of the contact. Crimping Dies Crimp the root of body as fig.5. same level Part Number ⑥ at-shrinkable tube Tool TNC-J-1.5DXW-CR10-120-CF CR-H-1100 TNC-J-2.5D2W-CR10-CF CR-H-1105 TNC-J-3D2W-CR10-CF CR-H-1135 TNC-BJ-2.5DQEW-CF CR-H-1105 ⑥ Cover the heat-shrinkable tube on the root of the body and heat up. ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 12 TNC Series Unit:mm ○ Assembly Instruction(5) Parts Configulration Ferule Heat-shrinkable tube ① Sheath Insulator Sleeve Body ① Cut the cable as fig.1. Please be careful to not damage the outer conductor. Outer Conductor Part Number A Ferule ② Contact Insulator A TNC-PJ-1.5DQEW-CR10-CF 13.0mm TNC-PJ-2H-1.5D-CR10-CF 10.0mm Spread the top ② Insert the ferule on the outer conductor and spread the top of the outer conductor. Sleeve ③ Center Conductor (Pre-soldering) B ● C Cut the center conductor after pre-soldering ③ Insert the sleeve and cut the cable as fig.3. Press in the sleeve between outer conductor and insulator. Cut off the extra outer conductor along the sleeve. Cut the insulator and center conductor as below table. Cut the center conductor after pre-soldering. Please be careful to not damage the center conductor. Part Number ④ C 5.7mm 3.0mm TNC-PJ-2H-1.5D-CR10-CF 4.0mm 3.0mm ④ Insert the insulator on the insulator of the cable and solder the contact with center conductor. When the solder is stick out, please shave the extra solder along the contact. Soldering Insulator B TNC-PJ-1.5DQEW-CR10-CF Contact No gap ⑤ ⑤ Insert the above contact into the body. Match the key in the insulator and keyway of the contact. Body Crimp the root of body as fig.5. same level Part Number Crimping Dies ⑥ Tool TNC-PJ-1.5DQEW-CR10-CF CR-H1142 TNC-PJ-2H-1.5D-CR10-CF CR-H1101 ⑥ Cover the heat-shrinkable tube on the root of the body and heat up. Heat-shrinkable tube ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 13 TNC Series Unit:mm ○ Assembly Instruction(6) Parts Configulration Washer Nut Gasket Clamp Contact Body 3D-2V ① ① The cable length require for the cable assembly L1=L-x L1 L Sheath Outer Conductor ② Please be careful to not damage the outer conductor. Nut 10 Washer Gasket ③ ② Insert nut, washer and gasket into the cable and cut the cable as fig.2. Pick the outer conductor and turn down to the clamp Clamp ③ Insert the clamp on the outer conductor and turn down the outer conductor. Cut the outer conductor along the clamp. Insulator Cut the insulator as fig.3. Please be careful to not damage the center conductor. Cut the center conductor after pre-soldering. Center Conductor (Pre-soldering) Trim the outer conductor along the clamp 0 +0.5 0 3-0.5 3 Contact Soldering ④ Insert the contact and solder the contact with center conductor. Please bee careful to not damage the insulator by heat. ④ Insulator No gap Body ⑤ Body assembly Flat Diameter: 9.5±0.2 Flat Diameter:9.5±0.2 ⑤ Insert the above contact into the body. Insert the the gasket and washer into the body and screw the nut. Recommended torque : 117.5 ∼ 147N・cm (12 ∼ 15Kgf・cm) +0.23 0.21 -0.13 (Gap between body and contact) ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp 14 TNC Series Unit:mm ○ Assembly Instruction(7) Parts Configulration Contact Insulator Ferule Heat-shrinkable tube Body Cable length which require for the cable assembly. L=L1-10.5 L1 ① Outer Conductor Cable ① Insert the heat-shrinkable tube into the cable. Sheath Heat-shrinkable tube ② Cut the cable as fig.1. Note)Please be careful to not damage the outer conductor. +1 15 0 Ferule ② Insert the ferule on the outer conductor Pick and spread the outer conductor. Pick and spread the top ③ Insulator Center Conductor Pre-soldering 0 2.9 -1 4 0.5 (9.7) No gap ④ Soldering Contact Insulator ⑤ Interface Dimension 4.98 0.25 (between contact and washer ③ Turn down the outer conductor to the ferule and cut the outer conductor as fig.3. Cut the insulator as fig. 3 and pre-solder the center conductor. And cut the center conductor as fig.3. Note)Please be careful to not center conductor. ④ Insert the insulator into the cable, solder up the contact with center conductor. Note)When the solder is stick out, please shave the extra solder along the contact. ⑤ Insert the body into the above cable assembly and crimp the root of the body. Note)When inserting the body, match the contact notch with projection of insulator. Note)Crimp the body with same level of body and dies. Note)Meet the interface dimension and crimp height Dies:A Cable assembly Same level Body b c Body Surface a Measurering point L/2 Crimp Height a,b,c(each sides)=4.76∼5.00 ⑥ Heat-shrinkable tube L ⑥ Cover the heat-shrinkable tube on the root of the body and heat up. ◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice. Moreover, the characteristic and the specification of the published product are the reference values. Please confirm the content with the latest delivery specifications when you use the product. http://www.ddknet.co.jp