TNC Series

TNC Style Connector
TNC Series
FEATURE
・ TNC series is a thread coupling coaxial
connector which is modified BNC style
Characteristic
Impedance
connector.
50 Ω
・ Due to the thread coupling, it is superior to
BNC style connector in vibration load.
Frequency
Range
・ Other electrical and mechanical characteristics
are same as BNC style connector.
DC to 2GHz
・ Recommended toque of coupling is
45 ∼ 68.6N・cm.
Lock Type
Screw
CONFORMING STANDARD
MIL-C-39012
SPECIFICATIONS
Characteristic Impedance
50 Ω
Dielectric Withstanding Voltage 500V AC(r.m.s) / 1 minute
Insulation Resistance
1,000M Ω min. at 500V DC
Contact Resistance
3m Ω max.
V.S.W.R.
1.3 max. (DC ∼ 2GHz)
* The specifications are typical but may not apply to all connectors.
Please check the specifications on each item with its drawing from us
when you use.
RoHS
MATERIAL/FINISH
Compliant
Compliant
Item
Material / Finish
Shell
Copper Alloy / Ni or Ag Plating
Contact (Female)
Copper Alloy / Ag or Au Plating
Contact (Male)
Copper Alloy /Ag or Au Plating
Insulator
PTFE
Gasket
Silicon Rubber
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
Moreover, the characteristic and the specification of the published product are the reference values.
Please confirm the content with the latest delivery specifications when you use the product.
110526
http://www.ddknet.co.jp
TNC Series
Unit:mm
○ Straight Cable Plug
Clamp Type
Part Number
Finish
Center
L Outer
Applicable Cable
Assembly
Instruction
Conductor Conductor
3D-2V
TNC-P-3-CF
3D-QEV
25.0
Ag
Ag
6
L
Crimp Type
Part Number
Applicable Cable φA
L Outer
Finish
Center
Assembly Crimp
Instruction Tool
φA
Conductor Conductor
TNC-P-1.5DQEW-CF
L
TNC-P-2.5D2W-CR10-CF
TNC-P-3D2W-CR10-CF
φA
Part Number
1.5D-2W
1.5D-QEW
2.5D-2W
2.5D-QEW
3D-2W
3D-QEW
5.5 22.3
Ni
Au
1
CR-H-1100
6.3 24.3
Ni
Ag
2
CR-H-1115
7.9 24.3
Ni
Ag
2
CR-H-1135
Applicable Cable φA
L Outer
Finish
Center
Assembly
Crimp Tool
Instruction
Conductor Conductor
TNC-P-2DFB-1-CF
2D-FB
6.2 29.7
Ni
L
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
Moreover, the characteristic and the specification of the published product are the reference values.
Please confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
2
Au
3
CR-H-1105
TNC Series
Unit:mm
○ Straight Cable Jack
φB
φA
Crimp Type
Part Number
Applicable
Cable
TNC-J-1.5DXW-CR10-120-CF
2D-FB
φA φB
Finish
Center
L Outer
Assembly
Crimp Tool
Instruction
Conductor Conductor
2.5D-2W
TNC-J-2.5D2W-CR10-CF
2.5D-QEW
L
Applicable
Cable
Part Number
5.5 12.0 26.8
Ni
Ag
4
CR-H-1142
6.25 14.6 25.0
Ni
Ag
4
CR-H-1105
φA φB
Finish
Center
L Outer
Assembly
Crimp Tool
Instruction
φB
φA
Conductor Conductor
3D-2W
TNC-J-3D2W-CR10-CF
7.9 14.6 25.42
3D-QEW
Ni
Ag
4
CR-H-1135
5.0
17.0
L
○ Straight Bulkhead Cable Jack
Applicable
Part Number
Cable
2.5D-2W
TNC-BJ-2.5D-QEW-CF
2.5D-QEW
φA φB
L Outer
Finish
Center
Assembly
Crimp Tool
Instruction
Conductor Conductor
14.0 6.25 27.9
Ni
Ag
4
CR-H-1105
※ Mounting Panel Thickness:2.7mm max.
+0.1
13
φ11.2 0 φA
φB
(Flat Diameter)
2
16.8
L
+0.1
0
10.2
10.4
(Detent Diameter)
Panel Mounting Dimensions
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
Moreover, the characteristic and the specification of the published product are the reference values.
Please confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
3
TNC Series
Unit:mm
○ Straight Panel Cable Jack
Crimp Type
Applicable
Part Number
Cable
Ni
1.5D-2W
Ag
5
CR-H-1142
4-φ3.0
4-φ3.0
12.7
12.7
φ5.5
Assembly
Crimp Tool
Instruction
Conductor Conductor
1.5D-QEW
TNC-PJ-1.5DQEW-CR10-CF
Finish
Center
Outer
φ12.0
15.8
2.3
12.7
□17.5
26.8
12.7
Panel Mounting Dimensions
Applicable
Part Number
Cable
TNC-PJ-1.5DXW-CR10-M-CF
Finish
Center
Outer
Assembly
Crimp Tool
Instruction
Conductor Conductor
1.5D-XW
Ni
1.5D-XWTA
Ag
7
CR-H-1100
+0.1
4-φ3.0 0
0.05
18.2
18.2
φ5.5
4-M2.5 0.45
+0.1
φ12.0 0
15.8
2.3
30.8
18.2
18.2
□25.4
0.05
Panel Mounting Dimensions
Applicable
Part Number
Cable
TNC-PJ-2H-1.5D-CR10-CF
1.5D-QEV
1.5D-2V
Outer
Finish
Center
Assembly
Crimp Tool
Instruction
Conductor Conductor
Ni
2-φ3.2
Ag
5
18.0
23.4
18.0
φ4
2-φ3.2
φ6.0
2.3
14.7
24.4
12
Panel Mounting Dimensions
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
Moreover, the characteristic and the specification of the published product are the reference values.
Please confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
4
CR-H-1101
TNC Series
Unit:mm
○ Receptacle Jack
Finish
Outer
Center
Conductor
Conductor
TNC-R-CF
Ag
Au
TNC-R-NiAu-CF
Ni
Au
Part Number
4-M2.6 0.45
0.15
12.7
12.7
0.05
φ1.4
4-φ2.8
+0.2
0
φ11.1
2.3
15.8
12.7
26.3
□17.5
12.7
0.05
Panel Mounting Dimensions
Finish
Outer
Center
Conductor
Conductor
TNC-R2-CF
Ag
Ag
TNC-R2-Ni-CF
Ni
Ag
TNC-R2-NiAu-CF
Ni
Au
Part Number
+0.1
4-φ3.0
12.7
12.7
0.05
φ1.4
4-φ3.0 0
+0.2
0
φ11.1
2.3
15.8
12.7
□17.5
26.3
12.7
0.05
Panel Mounting Dimensions
Finish
Outer
Center
Conductor
Conductor
Ni
Ag
Part Number
TNC-R2-2H-Ni-CF
0.05
18
23.3
18
φ1.4
2-φ3.0
+0.1
φ9.0 0
2.3
15.8
26.3
11
2-φ3
+0.1
0
Panel Mounting Dimensions
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
Moreover, the characteristic and the specification of the published product are the reference values.
Please confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
5
TNC Series
Unit:mm
○ Receptacle Jack
Finish
Outer
Center
Conductor
Conductor
Ni
Au
Part Number
TNC-SR-3-CF
+0.1
4-φ3.0 0
0.05
12.7
φ5.4
12.7
φ1.7
4-φ3.0
+0.1
0
φ12
4
2.3
9.6
15.8
12.7
27.7
12.7
□17.5
0.05
Panel Mounting Dimensions
Finish
Outer
Center
Conductor
Conductor
Ni
Au
Part Number
TNC-SR-6-CF
+0.1
4-φ3.1 0
12.7
12.7
0.05
φ4.0
0
φ1.27-0.1
4-φ3.0
(Thru-Hole)
+0.1
0
φ4.1
2
6.8
17.8
2
12.7
26.6
12.7
0.05
□17.5
Panel Mounting Dimensions
Finish
Outer
Center
Conductor
Conductor
Ni
Au
Part Number
4-φ3.0
(Thru-Hole)
+0.1
4-φ3.1 0
12.7
0.05
12.7
φ4.0
0
φ1.27-0.1
TNC-SR-9-CF
+0.1
0
φ4.1
12.7
2
8.5
17.8
2
□17.5
12.7
26.6
0.05
Panel Mounting Dimensions
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
Moreover, the characteristic and the specification of the published product are the reference values.
Please confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
6
TNC Series
Unit:mm
○ Receptacle Plug
Finish
Outer
Center
Conductor
Conductor
Ag
Ag
Part Number
TNC-PR-CF
+0.1
4-φ3.2 0
12.7
0.05
12.7
φ14.6
φ1.1
φ2.29
4-φ3.0
+0.1
φ9.0 0
18.0
2.3
12.7
28.5
□17.5
12.7
0.05
Panel Mounting Dimensions
○ Right Angle Receptacle Jack
Finish
Outer
Center
Conductor
Conductor
Part Number
TNC-LR-CF
Ag
Au
TNC-LR-Ni-CF
Ni
Ag
23
0.05
12.7
23
12.7
φ2.29
φ1.1
2.3
□17.5
14.3
+0.1
0
4-φ3
12.7
+0.1
φ9.0 0
4-φ3.0
12.7
0.05
Panel Mounting Dimensions
Finish
Part Number
TNC-LR-1-CF
21.6
4-M2.6
5
23.1
12.7
φ2.29
14.3
2.3
12.7
□17.5
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
Moreover, the characteristic and the specification of the published product are the reference values.
Please confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
7
Outer
Center
Conductor
Conductor
Ag
Ag
TNC Series
Unit:mm
○ Dust Cap
7/16-28UNEF-2B
Part Number
(φ14.5)
(φ3.5)
Finish
TNC-RC-1
Ni
TNC-RC-1-D1
Ag
(60)
(75)
(φ14.5)
7/16-28UNEF-2B
Part Number
TNC-C-2-CF
Ni
TNC-C-2-D1-CF
Ag
15
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
Moreover, the characteristic and the specification of the published product are the reference values.
Please confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
8
Finish
TNC Series
Unit:mm
○ Assembly Instruction(1)
Parts Configulration
Sleeve
Heat-shrinkable tube
Contact
Body
Insulator
Ferule
Cable length which require for the cable assembly.
L=L1-3.3
L=L2+19.7
Cable length
L
L2
L1
①
14.7
Sheath
②
① Insert the heat-shrinkable tube onto the cable.
Cut the cable as fig.1.
Please be careful to not damage the outer conductor.
Outer Conductor
Heat-shrinkable tube
0.5
② Insert the ferule on the outer conductor and
spread the top of the outer conductor.
Insulator
Insert the sleeve between insulator and outer
conductor. And cut the outer conductor along the sleeve.
Sleeve
Ferule
③
③ Cut the insulator as fig. 3.
Insulator
Outer Conductor
Please be careful to not damage the center conductor.
Pre-solder the center conductor and cut the center
conductor.
Please be careful to not damage the insulator by
soldering. Insert the insulator as fig.3.
Center Conductor
(Pre-soldering)
0
+0.2
4 -0.3
6.2 -0.5
Insulator
④
④ Solder up the contact with center conductor.
No gap between insulator and contact.
Soldering
No gap
Contact
⑤ Insert the body into the above cable assembly.
And crimp the root of the body.
Please be careful to meet the crimp height
as follows.
5.33∼5.84
⑤
(between body and contact)
B
(3.1)
Dies A
C
A
Measuring point
Note)Distance between body and contact must be met.
⑥
⑥ Cover the heat-shrinkable tube on the root of the body
and heat up.
Heat-shrinkable tube
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
Moreover, the characteristic and the specification of the published product are the reference values.
Please confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
9
TNC Series
Unit:mm
○ Assembly Instruction(2)
Parts Configulration
Boot
Ferule
①
Cable
Contact
Sleeve
① Insert the boot into the cable and
cut the cable as fig.1.
14
Boot
Body
Please be careful to not damage the outer conductor.
Outer Con
Sheath
Ferule
② Insert the ferule on the outer conductor and
spread the top of the outer conductor. Press-in rhe
sleeve between insulator and outer conductor.
②
Sleeve
Cut the extra outer conductor along the sleeve.
Outer Conductor
③ Cut the insulator and center conductor as fig.3.
Center Conductor
③
A
Part Number
B
④
Crimp Tool
4.0mm
TNC-P-3D2W-CR10-CF
5.5mm
3.5mm
Crimp the contact (match the side hole of contact
with the curve of crimping hole of tool.)
Center Conductor
No gap
Crimping Dies
⑤
B
5.0mm
④ Pinch the contact in the crimping hole(center
hole) and insert the center conductor of the cable.
Insulator
Tool Surface
A
TNC-P-2.5D2W-CR10-CF
Part Number
Contact
Crimp Tool
TNC-P-2.5D2W-CR10-CF
CR-H-1115
TNC-P-3D2W-CR10-CF
CR-H-1135
Contact crimped
Crimp Tool
⑤ Insert the above contact into the body. Match the
key in the insulator and keyway of the contact.
Body
Crimp the root of body as fig.5. Cover the boot on the
root of the connector body.
Body Surface
Boot
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
Moreover, the characteristic and the specification of the published product are the reference values.
Please confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
10
TNC Series
Unit:mm
○ Assembly Instruction(3)
Parts Configulration
Sleeve
Boot
①
Boot
Contact assembly
Sleeve
Body
① Insert the boot and sleeve into the cable and
cut the cable as fig.1. Please be careful to not
damage the outer conductor.
19
Outer Conductor
Sheath
Cable
7
10
4
②
4
② Cut the cable as fig.2. Cut the center conductor
after pre-soldering.
Outer Conductor
Aluminum foil tape
③
Insulator
Cente Conductor
(Cut off afterpre-soldering)
③ Insert the contact between outer conductor and
aluminum foil tape. Solder the contact with
center conductor.
When the solder is stick out, please shave
the extra solder along the contact.
Soldering
Contact assembly
1
④ Cover the sleeve on the outer conductor and
crimp as fig.4. Crimp Tool : (CR-H-1105)
④
Sleeve
⑤
⑤ Insert the above contact into the body and
screw. Cover the boot on the root of the body.
Boot
Body
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
Moreover, the characteristic and the specification of the published product are the reference values.
Please confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
11
TNC Series
Unit:mm
○ Assembly Instruction(4)
Parts Configulration
Heat-shrinkable tube
Ferule
Insulator
Sleeve
Sheath
Body
① Insert the heat-shrinkable tube into the cable
and cut the cable as fig.1. Please be careful to
not damage the outer conductor.
①
Heat-shrinkable tube
Contact
Outer Conductor
Part Number
Cable
A
②
Outer Conductor
Ferule
TNC-J-1.5DXW-CR10-120-CF
13.0mm
TNC-J-2.5D2W-CR10-CF
11.0mm
TNC-J-3D2W-CR10-CF
11.5mm
TNC-BJ-2.5DQEW-CF
13.0mm
Sleeve
② Insert the ferule on the outer conductor and
spread the top of the outer conductor. Press in
the sleeve between outer conductor and
insulator.
③ Cut off the extra outer conductor along the sleeve.
Spread the top
③
Cut the cable as fig.3. Cut the center conductor
after pre-soldering. Please be careful to not damage
the center conductor.
Insulator
Sleeve
Center Conductor
(Pre-soldering)
Outer Conductor
B
●
Part Number
C
TNC-J-1.5DXW-CR10-120-CF
④
A
Insulator
Soldering
Contact
B
C
5.7mm
2.8mm
TNC-J-2.5D2W-CR10-CF
3.0mm
2.5mm
TNC-J-3D2W-CR10-CF
3.1mm
2.5mm
TNC-BJ-2.5DQEW-CF
6.0mm
2.0mm
④ Insert the insulator and solder the contact with center
conductor. When the solder is stick out, please
shave the extra solder along the contact.
No gap
⑤
⑤ Insert the above contact into the body. Match the
key in the insulator and keyway of the contact.
Crimping Dies
Crimp the root of body as fig.5.
same level
Part Number
⑥
at-shrinkable tube
Tool
TNC-J-1.5DXW-CR10-120-CF
CR-H-1100
TNC-J-2.5D2W-CR10-CF
CR-H-1105
TNC-J-3D2W-CR10-CF
CR-H-1135
TNC-BJ-2.5DQEW-CF
CR-H-1105
⑥ Cover the heat-shrinkable tube on the root of
the body and heat up.
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
Moreover, the characteristic and the specification of the published product are the reference values.
Please confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
12
TNC Series
Unit:mm
○ Assembly Instruction(5)
Parts Configulration
Ferule
Heat-shrinkable tube
①
Sheath
Insulator
Sleeve
Body
① Cut the cable as fig.1.
Please be careful to not damage the outer
conductor.
Outer Conductor
Part Number
A
Ferule
②
Contact
Insulator
A
TNC-PJ-1.5DQEW-CR10-CF
13.0mm
TNC-PJ-2H-1.5D-CR10-CF
10.0mm
Spread the top
② Insert the ferule on the outer conductor and spread
the top of the outer conductor.
Sleeve
③
Center Conductor
(Pre-soldering)
B
●
C
Cut the center conductor after pre-soldering
③ Insert the sleeve and cut the cable as fig.3.
Press in the sleeve between outer conductor and
insulator. Cut off the extra outer conductor along the
sleeve. Cut the insulator and center conductor as below
table. Cut the center conductor after pre-soldering.
Please be careful to not damage the center conductor.
Part Number
④
C
5.7mm
3.0mm
TNC-PJ-2H-1.5D-CR10-CF
4.0mm
3.0mm
④ Insert the insulator on the insulator of the cable
and solder the contact with center conductor.
When the solder is stick out, please
shave the extra solder along the contact.
Soldering
Insulator
B
TNC-PJ-1.5DQEW-CR10-CF
Contact
No gap
⑤
⑤ Insert the above contact into the body. Match the
key in the insulator and keyway of the contact.
Body
Crimp the root of body as fig.5.
same level
Part Number
Crimping Dies
⑥
Tool
TNC-PJ-1.5DQEW-CR10-CF
CR-H1142
TNC-PJ-2H-1.5D-CR10-CF
CR-H1101
⑥ Cover the heat-shrinkable tube on the root of
the body and heat up.
Heat-shrinkable tube
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
Moreover, the characteristic and the specification of the published product are the reference values.
Please confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
13
TNC Series
Unit:mm
○ Assembly Instruction(6)
Parts Configulration
Washer
Nut
Gasket
Clamp
Contact
Body
3D-2V
①
① The cable length require for the cable assembly
L1=L-x
L1
L
Sheath
Outer Conductor
②
Please be careful to not damage the outer conductor.
Nut
10
Washer
Gasket
③
② Insert nut, washer and gasket into the cable and
cut the cable as fig.2.
Pick the outer conductor
and turn down to the clamp
Clamp
③ Insert the clamp on the outer conductor and turn
down the outer conductor. Cut the outer
conductor along the clamp.
Insulator
Cut the insulator as fig.3. Please be careful to not
damage the center conductor.
Cut the center conductor after pre-soldering.
Center Conductor
(Pre-soldering)
Trim the outer conductor
along the clamp
0
+0.5
0
3-0.5
3
Contact
Soldering
④ Insert the contact and solder the contact with
center conductor.
Please bee careful to not damage the insulator by
heat.
④
Insulator
No gap
Body
⑤
Body assembly
Flat Diameter:
9.5±0.2
Flat Diameter:9.5±0.2
⑤ Insert the above contact into the body.
Insert the the gasket and washer into the body and
screw the nut.
Recommended torque : 117.5 ∼ 147N・cm
(12 ∼ 15Kgf・cm)
+0.23
0.21 -0.13
(Gap between body and contact)
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
Moreover, the characteristic and the specification of the published product are the reference values.
Please confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp
14
TNC Series
Unit:mm
○ Assembly Instruction(7)
Parts Configulration
Contact
Insulator
Ferule
Heat-shrinkable tube
Body
Cable length which require for the cable assembly.
L=L1-10.5
L1
①
Outer Conductor
Cable
① Insert the heat-shrinkable tube into the cable.
Sheath
Heat-shrinkable tube
②
Cut the cable as fig.1.
Note)Please be careful to not damage the outer conductor.
+1
15 0
Ferule
② Insert the ferule on the outer conductor
Pick and spread the outer conductor.
Pick and spread the top
③
Insulator
Center Conductor
Pre-soldering
0
2.9 -1
4
0.5
(9.7)
No gap
④
Soldering
Contact
Insulator
⑤
Interface Dimension
4.98 0.25
(between contact and washer
③ Turn down the outer conductor to the ferule and
cut the outer conductor as fig.3.
Cut the insulator as fig. 3 and pre-solder the center
conductor. And cut the center conductor as fig.3.
Note)Please be careful to not center conductor.
④ Insert the insulator into the cable, solder up the
contact with center conductor.
Note)When the solder is stick out, please shave the
extra solder along the contact.
⑤ Insert the body into the above cable assembly and
crimp the root of the body.
Note)When inserting the body, match the contact notch
with projection of insulator.
Note)Crimp the body with same level of body and dies.
Note)Meet the interface dimension and crimp height Dies:A
Cable assembly
Same level
Body
b
c
Body Surface
a
Measurering point
L/2
Crimp Height
a,b,c(each sides)=4.76∼5.00
⑥
Heat-shrinkable tube
L
⑥ Cover the heat-shrinkable tube on the root of the
body and heat up.
◎ Please acknowledge that the specification etc. of this catalog might change by the improvement etc. without notice.
Moreover, the characteristic and the specification of the published product are the reference values.
Please confirm the content with the latest delivery specifications when you use the product.
http://www.ddknet.co.jp