Altech UL508 V-EA and MA Manual Motor Controllers Accessories E137938 UL508 Listed Accessories can be factory or field mounted on V-EA and MA manual motor controllers for enhanced control and monitoring capabilities. Field mounting kits include all necessary parts and instructions. Accessories can be gang mounted on a single controller (the Auxiliary Switch in the outside position). The mounting arrangement links the internal latch-pins for the tripping mechanisms, ensuring simultaneous trips. Handles are linked to simplify manual resetting. FA - Shunt Trip Trip/Coil Voltage AC or DC Type/ Cat. No. FA12UM FA24UM FA48UM FA110UM Standard Pack: 5 Weight: 525 grams (1.16 lb.) Width: 17.5mm (.689in.) Max. Coil Current 12V 24V 48-72V 110V/220V Approvals 1.3A 0.6A 0.2A 0.25A/0.5A UA - Undervoltage Trip (not UL listed) Type/ Cat. No. Line Voltage 60Hz* UA120UM UA220UM 120VAC 220VAC Standard Pack: 5 Weight: 750 grams (1.65 lb.) Width: 17.5mm (.689in.) H - Auxiliary Switch Type/ No. of Cat. No. Contacts H10UM H11UM H12UM H21UM Contact Type 1 2 3 3 1NO 1NO + 1NC 1NO + 2NC 2NO + 1NC Standard Pack: 10 Weight: 450 grams (0.99 lb.) Width: 9mm (.354in.) Add-on Neutral Pole Type/ Cat. No. N63UM Rating 0.3-63A/ 480Y/277V For further Busbar information please see our comprehensive Altech Universal Power Distribution catalog. Contact Rating Wire Size For Use with: 10A / 220V AC 3A / 110V DC or pulsed 1A / 220V DC or pulsed 4mm2 (12 AWG) V-EA, MA Approvals Approvals Standard Pack: 5 Weight: 0.775kg (1.71lb.) Width: 17.5mm (.689in.) * Please consult Altech for other voltages and your 50Hz application needs. 20 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com Lock-out ** Cat. No. EASS Cooling Spacer Cat. No. 15.960 Prevent inadvertent resetting of the V-EA or MA during maintenance. Fits 1/4” pad lock. TEMPERATURE CORRECTION CURVE Ambient Temperature and Adjacent Mounting/Loading Adjustment (V-EA/MA Ambient Temperature - 25°C to 55°C, Storage Temperature -40°C to 70°C) 160 Calibration Temperature 150 140 130 110 80 * Cooling spacer (Part #15.960) between each group of 3 poles will eliminate these adjustments. 50 -40 -40 -30 -22 -20 -4 -10 14 0 32 10 50 pol es adj ace nt m oun ted ma or ximum mo re , 2 0 % adj ace off R nt m C fo oun r a t ted otal * off 70 60 to 3 20 68 30 86 40 104 Ambient Temperature 50 122 60 140 70 158 10 pol es 80 176 Altech UL508 up 90 40 Adjacent Mounting Temperature Adjustment 3% of RC for every additional pole above 3. Maximum 20% off RC for a total of 10 poles or more.* % 100 20 Rated Current (%) 120 Ambient Temperature Adjustment 5% of RC for every 10°C (18°F). 90 (°C) 194 (°F) ** V-EA and MA can also be locked in the on and off position by simply using a common lead or meter seal, which gets fed through the hole in the handle and a corresponding hole in the housing. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 21