here - Chinfa

AMR1 SERIES
AC - DC DIN RAIL MOUNTABLE POWER SUPPLY
INDUSTRIAL CONTROL EQUIPMENT
FEATURES
‧UNIVERSAL INPUT 90~264VAC
‧SHORT CIRCUIT PROTECTION
‧INTERNAL INPUT FILTER
‧LOW PROFILE FOR BUILDING AUTOMATION
‧3 YEARS WARRANTY
R
R
R
H HH
Class I, Div 2
a
UL 60950-1
UL 1310
IND. CONT. EQ.
UL 508
EN 60950-1
MODEL LIST
MODEL NO.
INPUT
VOLTAGE
OUTPUT
WATTAGE
OUTPUT
VOLTAGE
OUTPUT
CURRENT
EFF.
(min.)
EFF.
(typ.)
Single Output Models
AMR1-05
90~264 VAC
7.5 WATTS
+ 5 VDC
1500 mA
73%
75%
AMR1-12
90~264 VAC
10 WATTS
+ 12 VDC
830 mA
77%
79%
AMR1-15
90~264 VAC
10 WATTS
+ 15 VDC
670 mA
78%
80%
AMR1-24
90~264 VAC
10 WATTS
+ 24 VDC
420 mA
78%
80%
SPECIFICATION
o
All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed
GENERAL
Characteristics
min.
Conditions
Switching frequency
Vi nom, Io nom
Isolation voltage
Input-Output
Isolation resistance
Input-Output, @ 500VDC
Ambient temperature
Operating at Vi nom
typ.
max.
132
o
unit
KHz
3,000/4,242
VAC / VDC
100
MΩ
+ 71
-40
o
o
C
% / oC
Derating (see derating curve)
Vi nom, from +61 C to +71 C
Storage temperature
Non operational
-40
+ 85
Relative humidity
Vi nom, Io nom
20
95
% RH
Temperature coefficient
Vi nom, Io min
± 0.03
% / oC
MTBF
Bellcore Issue 6 @40oC, GB
Altitude during operation
Free air convection
Installation position
Vertical ( other direction may derating using )
www.chinfa.com
2014.08.11
C
5V
901,000
Hours
888,000
Hours
15V
893,000
Hours
24V
910,000
Hours
4,850
L91 x W18 x D56.5
Cooling
o
12V
IEC 60068-2-13
Dimension
Pollution degree
2.5
m
mm
2
[email protected]
P1
AMR1 SERIES
SPECIFICATION
o
All Specifications Typical At Nominal Line, Full Load, 25 C Unless Otherwise Noticed
INPUT SPECIFICATIONS
Characteristics
Rated input voltage
Absolute input max. range
Conditions
Io nom
Ta min ... Ta max,
Io nom
Input current
Vi : 115 / 230 VAC, Io nom
Rated input current
Vi : 90 VAC, Io nom
Line frequency
Vi nom, Io nom
Inrush current
Power dissipation
Vi : 115 / 230 VAC , Io nom
Leakage current
Vi : 230 VAC, Io nom
typ.
max.
unit
100
240
VAC
AC in
90
264
VAC
DC in
120
375
VDC
min.
200 / 135
47
mA
300
mA
63
16 / 32
Hz
A
5V
2.5
W
12V
15V
2.7
W
2.5
W
24V
2.5
Input-Output
W
0.25
mA
max.
unit
±1
%
OUTPUT SPECIFICATIONS
Characteristics
Conditions
min.
Output voltage accuracy
(Adjusted before shipment)
Vi nom, Io max
Minimum load
Line regulation
Load regulation
Hold up time
Vi nom
Io nom, Vi min ...Vi max
Vi nom, Io min ...Io nom
Vi : 115 / 230 VAC , Io nom
Vi nom, Io nom
Vi nom, Io nom
Capacitor load
Vi nom, Io nom
Vi nom, Io nom
Capacitor load
Vi nom, Io nom
Vi nom, 1~0.5 Io nom
Vi nom, Io nom, BW = 20MHz
Vi nom, Io nom
5V
12V
15V
24V
Vi nom, Io nom
5V
12V
15V
24V
Vi nom, Io nom
5V
12V
15V
24V
Vi nom, Io nom
5V
12V
15V
24V
Vi nom, Io nom, Po / Pi
Turn on time
Rise time
Fall time
Transient recovery time
Ripple & noise
Power back immunity
Capacitor load
DC ON indicator threshold
at start up (Green LED)
DC LOW indicator threshold
after start up (Red LED)
Efficiency
typ.
0
%
%
%
ms
ms
ms
ms
ms
ms
ms
±1
±1
10 / 30
1,000
1,500
150
500
150
2
50
mV
VDC
VDC
VDC
VDC
μF
3,500
μF
1,800
μF
1,500
μF
560
4.5
VDC
3.5
VDC
10.8
9
VDC
13.5
11
VDC
19.2
21.6
4.5
VDC
3.5
VDC
10.8
9
VDC
13.5
11
VDC
19.2
21.6
Up to 80%, See model list and typ efficiency curve
7.5
18
22
35
CONTROL AND PROTECTION
Characteristics
Input fuse
Internal surge voltage protection
Rated over load protection
Over voltage protection
min.
Conditions
IEC 61000-4-5
Vi nom (see typ current limited curve)
Vi nom, Io nom
5V
(Auto Recovery)
12V
15V
24V
Output short circuit
Degree of protection
www.chinfa.com
2014.08.11
125
5.75
15
18
30
typ.
max.
T1A / 250VAC internal
Varistor
185
6.5
16.5
20
33
Hiccup mode
IP20
unit
%
VDC
VDC
VDC
VDC
[email protected]
P2
AMR1 SERIES
SPECIFICATION
All Specifications Typical At Nominal Line, Full Load, 25oC Unless Otherwise Noticed
APPROVALS AND STANDARDS
UL / cUL
UL 508 Listed
UL 60950-1, UL 1310 Class 2 Power Recognized
ISA 12.12.01(Class I, Division 2, Groups A, B, C and D)
TUV
EN 60950-1
CE
EN 61000-6-3, EN 55022 Class B, EN 61000-3-2, EN 61000-3-3
EN 61000-6-2, EN 55024, EN 61000-4-2 Level 3, EN 61000-4-3 Level 3
EN 61000-4-4 Level 4, EN 61000-4-5 L-N Level 3
EN 61000-4-6 Level 3, EN 61000-4-8 Level 4, EN 61000-4-11
ENV 50204 Level 2, EN 61204-3
Vibration resistance
meet IEC 60068-2-6 (Mounting on rail : 10-500 Hz, 2G, along X, Y, Z each Axis, 60 min for each Axis )
Shock resistance
meet IEC 60068-2-27 (15G, 11ms, 3 Axis, 6 Faces, 3 times for each Face)
PHYSICAL CHARACTERISTICS
Case size
91 x 18 x 56.5 mm (3.58 x 0.71 x 2.22 inches)
Case material
Plastic
Weight
65g
Packing
0.11kg ; 120
/ 14.5kg / 2.28CUFT
MECHANISM & PIN CONFIGURATION
mm [inch]
CONSTRUCTION
Easy snap-on mounting onto the DIN-Rail
(TS35/7.5 or TS35/15), unit sits safely and
firmly on the rail; no tools required even to remove
2 1
+
INSTALLATION
12.00 [0.47]
11.00 [0.43]
18.00 [0.71]
45.00 [1.77]
DC LO
L
3
N
56.50 [2.22]
49.60 [1.95]
32.30 [1.27]
51.50 [2.02]
91.00 [3.58]
DC ON
91.00 [3.58]
4
Ventilation / Cooling
Normal convection
All sides 25m/m free space
For cooling recommended
Connector size range
AWG26-12 (0.2~2.5mm2) flexible / solid cable
-Connector can withstand torque at maximum
5 pound-inches.
4~5m/m stripping at cable end recommends.
Use copper conductors only, 60/75 oC
GENERAL TOLERANCE
0.00[0.00] - 30.00[1.18]
±0.30[0.01]
30.00[1.18] - 120.00[4.72]
±0.50[0.02]
PIN ASSIGNMENT
1
2
3
OUT
Designation
IN
PIN NO
OTHER
4
www.chinfa.com
2014.08.11
Description
-
Negative output terminal
+
Positive output terminal
L
Input terminals (phase conductor, no polarity at DC input)
N
Input terminals (neutral conductor, no polarity at DC input)
DC ON
Operation indicator LED
DC LO
DC Low indicator LED
[email protected]
P3
AMR1 SERIES
CIRCUIT SCHEMATIC
‧Block diagram for AMR1 series
L
Fuse
N
Vo +
Inrush Current
Limiter and
rectifier
Switching
Device
Rectifier
Vo Control
circuit
Reference &
Error Amp.
Opto Isolation
Output Level
Detection
DC ON
(Green LED)
DC LO
(Red LED)
TYP. CURRENT LIMITED CURVE
Output Voltage [ % ]
v
AMR 1-24
Hiccup mode
100
50
t
Time
DERATING CURVE
TYP. EFFICIENCY CURVE
AMR1-24
85
80
EFFICIENCY [ % ]
Power out [ % ]
100
75
Safe Operating Area
75
70
65
60
230 Vac
115 Vac
55
50
0
-40
61
Temperature [ oC ]
www.chinfa.com
2014.08.11
71
10
25
50
75
100
Power out [ % ]
[email protected]
P4