Download Data Sheet

Rev A
DTIPU68 Series
60W (80Wpk)
Single Output
AC/DC Desktop Power Supply
FEATURES
● 100% Burn-in
● Class I Insulation
● IEC-320-C14 Input Inlet
● CEC and Energy Star Compliant
● No Load Power Consumption < 0.5
● Optional Output Connectors Available
● Over Voltage and Over Current Protection
● Over Voltage Protection (Crowbar Design)
● -20°C ~ 70°C Operating Temperature Range
● Wide Input Voltage Range: 90 to 264VAC, 47~63Hz
DESCRIPTION
The DTIPU68 series of AC/DC desktop switching mode power supplies provides 80 watts peak output power. This series consists of single
output supplies with a universal input range of 90~264VAC and an IEC-320-C14 AC input connector. Some features include no load power
consumption < 0.5, -20°C~+70°C operating temperature range, and over voltage and over current protection. All supplies are CEC, Energy
Star, and UL 94V-1 min compliant. This series meets FCC-Part-15 class B and CISPR-22 class B emission limits and are designed to
comply with UL/c-UL (UL 60950-1), TUV/GS (EN 60950-1), and new CE requirements. With the delay buffer duration of over current
protection a large amount of current can be acquired and the LPS safety requirement can be met which is very useful for motor
drivers/devices (peak load). All models are 100% burn-in tested.
SPECIFICATIONS: DTIPU68 Series
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
INPUT (Vin)
Operating Voltage Range
Input Frequency
Input Current (Low Line)
Input Current (High Line)
Inrush Current (Low Line)
Inrush Current (High Line)
Safety Ground Leakage Current
Start-Up Time
OUTPUT (Vo)
Output Voltage Range
Load Regulation
Line Regulation
Output Power
Output Current Range
Ripple & Noise (peak to peak)
Transient Response Time
Hold-Up Time
PROTECTION
Over Voltage Protection
Over Current Protection
GENERAL
Efficiency
Dielectric Withstanding Voltage
For Primary to Secondary
Dielectric Withstanding Voltage
For Primary to Ground
Isolation Resistance
No Load Power Consumption
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
MTBF
PHYSICAL
Weight
TEST CONDITIONS
Min
90
47
Io = Full Load, Vin = 115VAC
Io = Full Load, Vin = 230VAC
Io = Full Load, 25°C, Cool Start, Vin = 115VAC
Io = Full Load, 25°C, Cool Start, Vin = 230VAC
Io = Full Load, Vin = 240VAC
Io = Full Load, Vin = 100VAC
Vin = 230VAC
Io = Full Load
Vin = 90 to 264VAC
Full Load, Vin = 90VAC
Io = Full Load to Half Load, Vin = 100VAC
Io = Full Load, Vin = 100VAC
12
26
0.5
0.3
Unit
264
63
1
0.5
15
30
0.75
0.5
VAC
Hz
A
A
A
A
mA
s
%
%
W
%
ms
ms
16
112
110
Io = Full Load, Vin = 230VAC
Max
See Rating Chart
3
5
0.5
1
60
See Rating Chart
0.5
1
4
0
132
150
%
%
84
%
Primary to Secondary
4242
VDC
Primary to Ground
2121
VDC
Test Voltage = 500VDC
No load, Vin=240VAC
Derates linearly from 100% Load at 50°C to 50% load at 70°C
All Outputs
Operating Temperature at 25°C, Calculated per MIL-HDBK-217F
50
0.3
-20
-40
5
-0.04
MΩ
W
0.5
+70
+85
95
+0.04
130,000 hours
°C
°C
%
%/°C
Approximately 275 grams
5.75 x 2.99 x 1.69 inches
146.0 x 76.0 x 43.0 mm
Dimensions (L x W x H)
SAFETY
EMI Requirements for CISPR-22
EMI Requirements for FCC PART-15
Nom
Vin = 220VAC
Vin = 110VAC
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
B
B
Class
Class
DTIPU68 Series
60W (80Wpk)
Single Output
AC/DC Desktop Power Supply
Rev A
MODEL SELECTION TABLE
Input Voltage
Range
Preset Voltage
Output Voltage
Range
Output Current
Total Regulation(3)
Output Power
DTIPU68-105
90 ~ 264 VAC
13 VDC
11 ~ 13 VDC
6.66 A
3%
80Wpk
DTIPU68-108
90 ~ 264 VAC
27 VDC
21 ~ 27 VDC
3.33 A
2%
80Wpk
Model Number
NOTES
1. The output voltage is specified as a range (Ex: 21 ~ 27VDC); the preset voltage will be set as standard models if nothing
different is requested. Please contact factory for ordering details.
2. The output voltage ≥ 12VDC can meet CEC approvals.
3. An AWG#18/4ft output cable is required to use in order to meet the total regulation on each model. The total regulation will
change if a different output cable is used.
4. Optional output connectors are available. Please call factory for ordering details.
MECHANICAL DRAWING
Unit: inches [mm]
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797