Module Group C Screening H3

MODULE GROUP C TESTING
For Module H3
TEST
CONDITION
MIL-STD-750
TEST
METHOD
SUBGROUP 1
Physical
Dimensions
Terminal Strength
(tension)
Test Condition A, W = 10lbs., t = 15 seconds
2036
Moisture
Resistance
Omit initial conditioning
1021
Electrical
Reverse Current (IR) @ rated VWM
Breakdown Voltage (V(BR)) @ IT
4016
4022
SUBGROUP 3
1500Gs, 0.5ms, 5 blows in each orientation X1, Y1,
Z1
Vibration
Electrical
SMALL
LOT
(Units)
15 c=0
6 c=0
22 c=0
6 c=0
22 c=0
6 c=0
15 c=0
6 c=0
22 c=0
12 c=0
2066
SUBGROUP 2
Shock
SAMPLE
PLAN
(Units)
2016
2056
Reverse Current (IR) @ rated VWM
Breakdown Voltage (V(BR)) @ IT
4016
4022
SUBGROUP 4
Salt Atmosphere
1041
SUBGROUP 5
Operating Life
@ rated VWM, TA = +125°C for 1,000 hours
1026
Reverse Current (IR) @ rated VWM, D-IR = 50% or
1µA, whichever is greater
Breakdown Voltage (V(BR)) @ IT, D-V(BR) ±5% from
initial reading
4016
Electrical
4022
Note: For bidirectional devices, test both polarities – split hours on Burn-in test and surge pulse to 50% each polarity.
Attributes Data Supplied
Sampling per MIL-PRF-19500
Module – H3(Group C)
05235.R0 03/10
ProTek Devices
2929 S. Fair Lane ● Tempe, Arizona ● 85282
Tel: 602-431-8101 ● Fax: 602-431-2288
Email: [email protected] ● Web: www.protekdevices.com
1