Rev. A PSDN-40 Series 40 Watt Single Output AC/DC DIN Rail Power Supply FEATURES ● Single Output ● RoHS Compliant ● Brown Out Protection ● True DC OK Signal Output ● Withstand 5G Vibration Test ● Universal AC Input 88~264VAC ● Installed on DIN Rail TS35 / 7.5 or 15 ● UL1310 Class 2 Power Unit / LPS Pass ● High Operating Temperature up to 70°C ● UL508 (Industrial Control Equipment) Listed ● High Efficiency, Long Life, and High Reliability ● All Using 105°C Long Life Electrolytic Capacitors ● Short Circuit, Over Load, and Over Voltage Protection DESCRIPTION The PSDN-40 series of AC/DC DIN Rail power supplies provides 40 Watts of continuous output power. All models have a single output and a universal input range. All models are over load, over voltage, and short circuit protected. SPECIFICATIONS: PSDN-40 Series All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. INPUT SPECIFICATIONS Input Voltage Range (See Note 3) 88 ~ 264VAC or 124 ~ 370VDC Input Frequency 47 to 63Hz AC Current (typical) 0.8A at 115VAC 0.4A at 230VAC Inrush Current (typical) Cold Start 30A at 115VAC 60A at 230VAC Leakage Current < 1mA at 230VAC OUTPUT SPECIFICATIONS Output Voltage See Table Output Power See Table Output Voltage Adjustability ±10% Voltage Tolerance (See Note 2) ±1% Line Regulation ±1% Load Regulation ±1% Output Current See Table Ripple & Noise (See Note 1) See Table Setup, Rise Time < 800ms, <50ms @ 230VAC and full load Hold Up Time (typical) > 16ms at 115VAC and full load, > 32ms at 230VAC and full load PROTECTION 115% ~ 150% rated output voltage Over Voltage Protection Protection Type: Latch-off mode > 105°C rated output power Over Load Protection Protection type: constant current limiting, automatically after fault condition is removed. GENERAL SPECIFICATIONS Efficiency See Table Withstand Voltage I/P - O/P: 4242VDC, I/P - FG: 2121VDC for 1 minute Isolation Resistance I/P - O/P, I/P - FG, O/P - FG: 100MΩ / 500VDC DC OK Signal Relay contact (30VDC / 1A, 120VAC / 1A) ENVIRONMENTAL SPECIFICATIONS Working Temperature -20°C ~ +70°C (refer to output load derating curve) Storage Temperature -40°C ~ +85°C Working Humidity 20% ~ 90% RH, non-condensing Storage Humidity 10% ~ 95% RH Vibration 10 ~ 500Hz, 5G 0.5Oct/min, period for 60 min., Each along X,Y,Z axes. Cooling Free Air Convection Temperature Coefficient ±0.03% / °C (0 ~ 50°C) PHYSICAL SPECIFICATIONS Packing 0.28Kg Dimensions (W x H x D) 1.57 x 3.54 x 3.90 inches (40 x 90 x 99 mm) Connection I/P: 3 poles, O/P: 6 poles screw DIN terminal SAFETY & EMC (See Note 4) Safety Standards UL 508, TUV EN60950-1, UL1310 NEC class 2 compliant EMI Conduction & Radiation EN55022: 2006 (Class B), EN61204-3: 2000, EN61000-6-3: 2007 Harmonic Current EN61000-3-2,3: 2006 EMS Immunity EN55024, EN61204-3: 2000, EN61000-6-1: 2007 (EN61000-4-2,3,4,5,6,8,11) Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 PSDN-40 Series 40 Watt Single Output AC/DC DIN Rail Power Supply Rev. A MODEL SELECTION GUIDE Model Number Input Voltage Output Voltage Output Current Rated Output Power Ripple & Noise (1) Efficiency PSDN-40-12 88 ~ 264VAC (124 ~ 370VDC) 12 VDC 3.4A 40.8W 100mVp-p 85% PSDN-40-15 88 ~ 264VAC (124 ~ 370VDC) 15 VDC 2.7A 40.5W 100mVp-p 85% PSDN-40-24 88 ~ 264VAC (124 ~ 370VDC) 24 VDC 1.7A 40.8W 120mVp-p 86% PSDN-40-48 88 ~ 264VAC (124 ~ 370VDC) 48 VDC 0.85A 40.8W 180mVp-p 87% NOTES 1. Ripple & noise is measured at 20MHz bandwidth by using a 12" twisted pair-wire terminated with a 0.1µF & 47µF capacitors in parallel. 2. Tolerance includes set up tolerance, line regulation, and load regulation. 3. Derating may be needed under low input voltages. Please check the derating curve for more details. 4. The power supply is considered a component, which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. In parallel connection only one unit may operate if the total output load is less than 5% of the rated load. BLOCK DIAGRAM DC OK RELAY CONTACT Contact Close When the output voltage reaches the adjusted output voltage Contact Open When the output voltage drops below 90% output voltage Contact Ratings (max.) 30V / 1A resistive load Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 PSDN-40 Series 40 Watt Single Output AC/DC DIN Rail Power Supply Rev. A DERATING CURVES Load vs Temperature Load vs Input Voltage Ta=25°C 100 100 90 Load (%) Load (%) 80 60 40 80 70 60 50 20 -20 40 0 10 20 30 40 50 60 85 70 Ambient Temperature (°C) 100 110 Input Voltage (VAC) 60Hz MECHANICAL DRAWING Unit: inches (mm) 1.57 (40) 1.38 (35) 3.90 (99) 3.54 (90) 0.2 0.2 0.2 0.2 0.2 (5) (5) (5) (5) (5) N Install DIN Rail TS35/7.5 or TS35/15 120 L 0.30 0.30 (7.5) (7.5) Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 264