PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 5:03 PM Page 28 PSC-96 Series Type Approved OUTPUT E361935 E205412 Features: • • • • • • • • • • • • ENERGY SAVER Universal AC input (88-264V AC) Protections: Short Circuit / Overload / Overvoltage Brown-out protection Installed on DIN rail TS35 / 7.5 or 15 True DC OK signal output All wiring 105°C long life electrolytic capacitors High operation temperature up to 70°C Withstands 2G vibration test High efficiency, long life and high reliability 3 year warranty UL1310 Class 2 Power unit / LPS pass UL508 (Industrial control equipment) listed Cat. No. PSC-9612* PSC-9615* PSC-9624 PSC-9648 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 12V 7.5A 0 ~ 7.5A 90W 180mVp-p 15V 6.4A 0 ~ 6.4A 96W 180mVp-p 24V 4A 0 ~ 4A 96W 180mVp-p 48V 2A 0 ~ 2A 96W 250mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 10.8 ~ 13.2V ±1.0% 13.5 ~ 16.5V ±1.0% 21.6 ~ 26.4V ±1.0% 43.2 ~ 52.8V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE ±1.0% ±1.0% ±2.0% ±2.0% < 800ms, < 40ms / 230VAC at full load > 32ms / 230VAC; >16ms / 115VAC at full load ±1.0% ±2.0% ±1.0% ±2.0% 88 ~ 264VAC; 124 ~ 370VDC Derating may apply in low input voltage. Please check the derating curve for more details. PROTECTION FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER LOAD PROTECTION 47Hz~63Hz < 0.92 / 230VAC; < 0.98 / 115VAC at full load 87% 87% 1.1 A / 115VAC; 0.55A / 230VAC COLD START 30A / 115VAC; 60A / 230VAC <1mA / 230VAC 88% 87% > 102% rated output power Protection type: Constant current limiting, recovers automatically after fault condition is removed. OVER VOLTAGE PROTECTION 115% ~ 150% rated output voltage Protection type: latch-off mode OVER TEMPERATURE PROTECTION 90˚C ± 10˚C (RTH2) detect on heat sink of power transistor Protection type: Shut down overvoltage, re-power on to recover ENVIRONMENT SAFETY & EMC OTHERS WORKING TEMP. WORKING HUMIDITY STORAGE TEMP. / HUMIDITY TEMP. COEFFICIENT VIBRATION -20 ~ +70˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85˚C; 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY UL508, TUV EN60950-1:2006+A11, UL1310 NEC class 2 compliant I/P-O/P: 4242DC I/P-FG: 2121DC 1 minute I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC EN55022:2006 Class B EN61000-3-2:2006 Class A, EN61000-3-3: 1995+A1: 2001+A2: 2005 EN61204-3:2000, EN55024:1998+A1:2001+A2:2003 light industry level, criteria A The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed that is still meets EMC directives. DC OK Signal MTBF DIMENSION PACKING CONNECTION COOLING Relay contact (24VDC / 1A, 120VAC / 1A) 120.4K Hrs MIL-HDBK-217F 55x90x99 mm (WxHxD) 0.4Kg/24 pcs. / 10.8Kg l/P 3 poles, 0/P: 6 poles screw DIN terminal Free air convection All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature. *Not included in UL E361935 28 For the latest on Altech Power Supplies please visit www.altechcorp.com/power. PowerSupplies_2013.QXD_PowerSupplies(v5).QXD 9/18/13 3:43 PM Page 29 PSC-96 Series Type Approved E361935 E205412 ENERGY SAVER Mechanical Specification Unit : mm / inch 55 99 Terminal Pin. No Assign. (TB1) Assignment FG AC/N AC/L 90 Pin No. 1 2 3 Terminal Pin. No Assign. (TB2) Pin No. 1,2 3,4 5,6 Assignment DC OUTPUT +V DC OUTPUT -V DC OK RELAY CONTACT Block Diagram DC O K E M I F I LT E R & R E C T IF IE R S I /P PFC C IR C U IT R E C T IF IE R S & F I LT E R P OWE R S W IT C H IN G +V -V DC O K O .C .P . O .L .P . O .V .P . O .L .P . D E T E C T IO N C IR C U IT P W M& P F C C O N T R O L O .V .P . O .T .P . DC OK Relay Contact Contact Close When the output voltage reaches the adjusted output voltage Contact Open When the output voltage drop below 90% rated output voltage Contact Ratings (max.) 30V / 1A resistive load Derating Curve Load V .S Temp. Load V .S I/P V oltage Ta=25°C 100 100 90 Load (%) Load (%) 80 60 80 70 60 40 50 20 -20 40 0 10 20 30 40 50 Ambient Temperature (°C) 60 70 85 100 110 120 264 VAC Input Voltage(VAC) 60Hz Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 29