DATASHEET Rev. A PSMP20 SERIES 85~264VAC (125~373VDC) Input Voltage Range Single Outputs, Isolation Class II 20 Watts, Open Frame Medical AC/DC Switching Power Supplies MEDICAL FEATURES Isolation Class II Withstand 2G Vibration Test 3.5” x 2.0” x 0.76” Open Frame Package Universal Input Voltage: 85~264VAC or 125~373VDC Single Outputs 20 Watts Output Power 100% Full Load Burn-in Tested All Using 105°C Long Life Electrolytic Capacitors Cooling by Free Air Convection -20°C ~ +70°C Wide Operating Temperature Range ±10% Voltage Adjustment Short Circuit, Over Load, Over Voltage, and Brown-out RoHS Compliant (Low AC Input Voltage) Protection UL60601-1, TUV EN60601-1, and IEC60601-1 Medical Energy Star Compliant Green Design, No-Load Power Consumption < 0.5W Approvals DESCRIPTION The PSMP20 series of Medical AC/DC switching mode power supplies provides 20 Watts of continuous output power in a 3.5” x 2.0” x 0.76” open frame package. This series consists of 5V, 12V, 15V, and 24VDC output models with a universal input voltage range of 85~264VAC or 125~373VDC. These power supplies are protected against short circuit, over load, over voltage, and brown-out (low AC input voltage) conditions and have an MTBF of 188,300 hours using MIL-HDBK217F. This series also has UL60601-1, TUV EN60601-1, and IEC60601-1 medical approvals. All models have been 100% full load burn-in tested and are RoHS and Energy Star compliant. 12/02/2011 Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 Page 1 of 4 PSMP20 Series 20 Watts, Open Frame Single Outputs, Isolation Class II Medical AC/DC Switching Power Supplies Rev. A SPECIFICATIONS: PSMP20 Series All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION INPUT SPECIFICATIONS Input Voltage Range TEST CONDITIONS AC Input Voltage Range DC Input Voltage Range Low Line High Line Low Line Inrush Current High Line No Load Power Consumption OUTPUT SPECIFICATIONS Output Voltage Voltage Tolerance Full Load, Vin = 115VAC Full Load, Vin = 230VAC Cold Start, Vin = 115VAC Cold Start, Vin = 230VAC Line Regulation Output Power Output Current Ripple & Noise (See Note 1) Low Line Hold-Up Time High Line Setup Time (See Note 3) Low Line Rise Time High Line Temperature Coefficient PROTECTION Over Voltage Protection Over Load Protection Short Circuit Brown-out (Low AC Input Voltage) GENERAL SPECIFICATIONS Efficiency Withstand Voltage Isolation Resistance ENVIRONMENTAL SPECIFICATIONS Operating Temperature Storage Temperature Operating Humidity Storage Humidity Vibration Cooling MTBF PHYSICAL SPECIFICATIONS Weight 12/02/2011 Unit 264 373 63 VAC VDC Hz A A 0.5 5VDC output model 12V, 15V, & 24VDC output models 5VDC output model 12V, 15V, & 24VDC output models Low Line to High Line at rated load 0% to 100% rated load -2 -1 -10 -1 -0.5 -0.5 0 Full Load, Vin = 115VAC Full Load, Vin = 230VAC Full Load, Vin = 115/230VAC Full Load, Vin = 115VAC Full Load, Vin = 230VAC 0~50°C -0.03 Latch-off mode Hiccup mode, recovers automatically after fault condition is removed 115 110 W See Table +2 +1 +10 +1 +0.5 +0.5 20 See Table See Table 18 60 1000 25 35 +0.03 % % % % W ms ms ms %/°C 150 % % yes yes Vin = 230VAC Input to output 500VDC With derating (see derating curve) Non-condensing MIL-HDBK-217F See Table 4000 100 VAC MΩ -20 +70 °C -40 +85 °C 20 90 % RH 10 95 % RH 10~500Hz, 2G 10min/1cycle, period for 60 min each along X, Y, and Z axes Free air convection 188,300 hours Approximately 2.68oz (76g) 3.5 x 2.0 x 0.76 inches (88.9 x 50.8 x 19.3 mm) 3 years Dimensions (L x W x H) Warranty SAFETY & EMC Safety Approvals EMI Conduction & Radiation Harmonic Current EMS Immunity Max 0.6 0.4 30 65 Voltage Adjustment Range Load Regulation Nom 85 125 47 Input Frequency Input Current Min UL60601-1, TUV EN60601-1, and IEC60601-1 EN55011: 2007+A2: 2007 Class B EN61000-3-2: 2006 Class A, EN61000-3-3: 1995+A1: 2001+A2: 2005 EN60601-1-2: 2001+A1: 2006, IEC61000-4-2,3,4,5,6,8,11 light industry level, criteria A Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 Page 2 of 4 PSMP20 Series 20 Watts, Open Frame Single Outputs, Isolation Class II Medical AC/DC Switching Power Supplies Rev. A MODEL SELECTION TABLE Model Number Input Voltage Range Output Voltage Output Current Ripple & Noise (1) Efficiency Output Power 5 VDC 4A 80mVp-p 77% 20W 12 VDC 1.66A 150mVp-p 82% 20W 15 VDC 1.33A 150mVp-p 84% 20W 24 VDC 0.84A 240mVp-p 85% 20W PSMP-20-05 85 ~ 264 VAC or 125 ~ 373 VDC PSMP-20-12 PSMP-20-15 PSMP-20-24 NOTES 1. Ripple & noise is measured at 20MHz bandwidth by using 12" twisted pair-wire terminated with 0.1µF and 47µF capacitors in parallel. 2. Tolerance includes set up tolerance, line regulation, and load regulation. 3. The length of the setup time is measured a first cold start. Turning the power supply ON and OFF very quickly may lead to an increase in the setup time. 4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. BLOCK DIAGRAM RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING PWM CONTROL +V -V DETECTION CIRCUIT DERATING CURVE Load vs Input Voltage Load vs Temperature Ta=25°C rated output voltage, 100% load, 115-230VAC 100 100 90 Load (%) Load (%) 80 60 80 70 60 40 50 20 40 -20 0 10 20 30 40 50 60 70 85 100 Ambient Temperature (°C) 12/02/2011 Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 110 120 264 Input Voltage (VAC) Page 3 of 4 PSMP20 Series 20 Watts, Open Frame Single Outputs, Isolation Class II Medical AC/DC Switching Power Supplies Rev. A MECHANICAL DRAWING 3.5 (88.9) 0.15 (3.75) 0.15 (3.75) 0.76 (19.3) Unit: inches (mm) 1.7 (43.3) 2.0 (50.8) 3-0.13” (3.3mm) Dia. Mounting Holes C2 COMPANY INFORMATION Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008 certification is just one example of our commitment to producing a high quality, well-documented product for our customers. Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your future projects. Contact Wall Industries for further information: Phone: Toll Free: Fax: E-mail: Web: Address: 12/02/2011 (603)778-2300 (888)587-9255 (603)778-9797 [email protected] www.wallindustries.com 5 Watson Brook Rd. Exeter, NH 03833 Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 Page 4 of 4