SKY65364_21_203189F.pdf

DATA SHEET
SKY65364-21: 900 MHz Transmit/Receive Front-End Module
Applications
 Automated meter reading
 Advanced metering infrastructure
Digital
Control
3
Control
Logic
VPC
 ISM systems
PA
 Range extender
Matching
Network
Harmonic
Filter
Features
TX
ANT
 Transmit output power > +30 dBm
Harmonic
Filter
Matching
Network
 High-efficiency PA
Matching
Network
LNA
RXO
Bias
 Analog power control
RX1
 Receive path NF <2.1 dB
 PA bypass mode
RX2
RBIAS
203189E-001
Figure 1. SKY65364-21 Functional Block Diagram
 LNA low-current mode with external resistor
 LNA bypass mode
Description
 Integrated control logic
The Skyworks SKY65364-21 is a high-performance,
transmit/receive (T/R) front-end module (FEM). The device
provides a complete T/R chain with T/R switches.
 Internal RF match and bias circuits
 All RF ports internally DC blocked
 Shutdown mode
 Small footprint, MCM (28-pin, 6 x 6 mm) package
(MSL3, 260 C per JEDEC J-STD-020)
Skyworks GreenTM products are compliant with
all applicable legislation and are halogen-free.
For additional information, refer to Skyworks
Definition of GreenTM, document number
SQ04–0074.
The device transmit chain features +30 dBm output power and a
40 percent power-added efficiency (PAE).
The device receive chain features a low-noise amplifier (LNA) with
a 1.5 dB noise figure (NF) and 15 dB gain. The cascaded NF and
gain, taking into account the 0.5 dB insertion loss
transmit/receive antenna switch, are 2.1 dB and 14.5 dB,
respectively, which makes the SKY65364-21 ideal for medium
power microwave links such as 900 MHz Industrial, Scientific,
and Medical (ISM) band applications.
The module also has a shutdown mode, PA bypass mode, and
LNA bypass mode to minimize power consumption.
The device is mounted in a 28-pin, 6 x 6 mm Multi-Chip Module
(MCM) surface-mount technology (SMT) package, which allows
for a highly manufacturable low-cost solution.
A functional block diagram of the SKY65364-21 is shown in
Figure 1. The device package and pinout for the 28-pin MCM are
shown in Figure 2. Signal pin assignments and functional pin
descriptions are provided in Table 1.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
203189F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 24, 2016
1
GND
VCC_TX3
VCC_TX2
VCC_TX1
VDD2
27
26
25
24
23
21
GND
EN
3
20
TX
BYP
4
19
GND
VPC
5
18
RXO
GND
6
17
VCC_RX
ANT
7
16
VDD1
GND
8
15
GND
9
10
11
12
13
14
RBIAS
2
RX2
GND
GND
22
GND
TR
28
RX1
1
GND
GND
GND
DATA SHEET • SKY65364-21: T/R FRONT-END MODULE
203189E-002
Figure 2. Figure 1. SKY65364-21 Pinout
(Top View)
Table 1. SKY65364-21 Signal Descriptions
Pin
Name
Description
Pin
Name
Description
1
GND
Ground
15
GND
Ground
2
TR
Digital control input: transmit/receive mode
16
VDD1
3.3 V power supply
3
EN
Digital control input: shutdown mode
17
VCC_RX
3.3 V power supply
4
BYP
Digital control input: bypass mode
18
RXO
Receive output
5
VPC
Transmit output power adjustment
19
GND
Ground
6
GND
Ground
20
TX
Transmit path input port. Internally matched
to 50 Ω.
7
ANT
Antenna switch common port. Internally
matched to 50 Ω.
21
GND
Ground
8
GND
Ground
22
GND
Ground
9
GND
Ground
23
VDD2
3.6 V power supply
10
RX1
Receive arm of antenna switch. Internally
matched to 50 Ω.
24
VCC_TX1
3.6 V power supply
11
GND
Ground
25
VCC_TX2
3.6 V power supply
12
GND
Ground
26
VCC_TX3
3.6 V power supply
13
RX2
LNA and bypass switch output port.
Internally matched to 50 Ω.
27
GND
Ground
14
RBIAS
LNA bias setting resistor
28
GND
Ground
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
May 24, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203189F
DATA SHEET • SKY65364-21: T/R FRONT-END MODULE
Technical Description
Receive Path
The SKY65364-21 consists of a complete T/R chain with T/R
switches contained in the module. A single-pole, triple-throw
(SP3T) switch selects between the receive, transmit, and transmit
bypass paths. The module has a shut-down mode to minimize
power consumption.
The receive path contains an LNA with bypass switch. The LNA
impedance matching networks are internal to the module and
have been optimized for a low NF while maintaining good return
losses into a 50 Ω source and load impedance. The receive arm
of the SP3T switch and the LNA input are connected to module
pins to allow an external filter to be inserted into the receive path.
Three digital input pins (EN, TR, and BYP) are used to select
between transmit, transmit bypass, receive, receive bypass, or
shutdown mode.
Transmit Path
The transmit path contains a Power Amplifier (PA) optimized for
saturated performance. The PA output is internally matched for
optimum output power and efficiency into a 50 Ω load
impedance. The PA output is passed through an harmonic filter
before being fed through the SP3T switch. The PA input provides
a good return loss into a 50 Ω source impedance.
Transmit output power is controlled by the VPC pin, which is
normally set to 2.25 V DC voltage. The nominal DC input
impedance into the VPC pin is 50 kΩ.
Operation Mode Control
The five SKY65364-21 operating modes are controlled by the
three digital pins TR, EN, and BYP (pins 2, 3, and 4, respectively).
The control logic truth is provided in Table 2.
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY65364-21 are provided
in Table 3. Recommended operating conditions are specified in
Table 4. Electrical specifications are provided in Tables 5, 6,
and 7.
Table 2. SKY65364-21 Operating Modes Truth Table1
Control Voltage
Internal States
TR
(Pin 2)
EN
(Pin 3)
BYP
(Pin 4)
PA
LNA
LNA Bypass
Switch
T/R Switch
PA Bypass
Switch
Transmit
1
1
0
On
Off
Open
PA
PA
Transmit bypass
1
1
1
Off
Off
Open
PA bypass
PA bypass
Receive
0
1
0
Off
On
Open
RX1
Open
Receive Bypass
0
1
1
Off
Off
Through
RX1
Open
Shutdown2
X
0
X
Off
Off
Open
Open
Open
Operating Mode
1 See Table 4 for logic 0 and 1 characteristics. “X” = don’t care state, defined as a valid state of logic 1 or 0.
2 In the high state, EN, TR, and BYP have an input current of 33 μA due to an internal 100 kΩ pulldown resistance. For the lowest leakage current, the high state is not recommended for TR
and BYP when the device is in shutdown mode (EN = 0).
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
203189F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 24, 2016
3
DATA SHEET • SKY65364-21: T/R FRONT-END MODULE
Table 3. SKY65364-21 Absolute Maximum Ratings1
Parameter
Symbol
Minimum
Maximum
Units
–0.3
+5.0
V
20
mA
–0.3
+6.0
V
1.6
A
LNA supply voltage
VCC_RX
LNA supply current
ICC_RX
PA supply voltage
VCC_TX1/2/3
PA supply current
ICC_TX
Digital supply voltage
VDD1
–0.5
+5.5
V
Digital supply voltage
VDD2
–0.5
+5.5
V
Digital control voltage (EN, TR, BYP)
VCTL
–0.5
VDD1 + 0.3
V
Transmit output power control voltage
VPC
–0.3
+5.0
V
Receive RF input power (RX2)
PIN_RX2
+5
dBm
Receive bypass RF input power (RX2)
PIN_RX2_BYP
+18
dBm
Receive RF input power (ANT)
PIN_ANT
+33
dBm
Transmit RF input power
PIN_TX
+15
dBm
+20
dBm
+85
°C
Transmit RF input power, bypass mode
PIN_TX_BYP
Operating case temperature (Note 2)
TC
–40
Storage temperature
TSTG
–55
+150
°C
Junction temperature
TJ
+150
°C
T/R port load VSWR in transmit mode
VSWR
10:1
–
1 Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set
at or below their nominal value.
2 Nominal thermal resistance, junction to case, is 18 °C/W.
ESD HANDLING: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This
device must be protected at all times from ESD when handling or transporting. Static charges may easily produce
potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industrystandard ESD handling precautions should be used at all times.
Table 4. SKY65364-21 Recommended Operating Conditions
Parameter
Symbol
Minimum
Transmit frequency range
f
Receive frequency range
f
900
LNA supply voltage
VCC_RX
3.00
Digital supply voltage
VDD1
VDD2
PA supply voltage
Digital input voltage, logic 1 (EN, TR, BYP)
Digital input voltage, logic 0 (EN, TR, BYP)
Typical
890
Maximum
Units
960
MHz
960
MHz
3.30
3.45
V
3.00
VCC_RX
VCC_RX
V
3.40
VCC_TX1/2/3
3.80
V
VCC_TX1/2/3
3.40
3.60
3.80
V
VIH
2.8
VDD1
V
VIL
0
0.7
V
Transmit output power control voltage
VPC
0
Receive RF input power (RX2)
PIN_RX2
Transmit RF input power (TX)
PIN_TX
Transmit duty cycle
2.25
+12
2.50
V
–15
dBm
+13
dBm
50
%
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
May 24, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203189F
DATA SHEET • SKY65364-21: T/R FRONT-END MODULE
Table 5. SKY65364-21 DC Electrical Specifications1
(VCC_RX = VDD1 = 3.3 V, VCC_TX1/2/3 = VDD2 = 3.6 V, TC = 25 C, RBIAS = 0 Ω, No RF Input Power, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
Quiescent current, receive mode2
IQ_RX
12
mA
Quiescent current, receive bypass mode2
IQ_BYP
80
μA
VDD1 quiescent current, transmit mode
IQ_VDD1
22
VCC_TX1/2/3 quiescent current, transmit mode
IQ_TX
TC = 25 °C,
VCC_TX1/2/3 = 3.6 V,
VCC_RX = 3.3 V
18
VCC_TX1/2/3 operating current, transmit mode
IOP_TX
PIN = +12 dBm
680
VDD1 quiescent current, transmit bypass mode3
IDD1
VCC_TX1/2/3 quiescent current, transmit bypass
mode3
IQ_TXB
VCC_RX quiescent current, shutdown mode3
VCC_TX1/2/3 quiescent current, shudown mode3
Digital input current, logic 13
Digital input current, logic 03
30
mA
mA
750
mA
50
μA
4
μA
IQ_SD_RX
0.5
μA
IQ_SD_TX
0.005
μA
IIH
33
μA
IIL
0
μA
1 Performance is guaranteed only under the conditions listed in this table. Modes are established as indicated in Table 2.
2 Total current drawn from VCC_RX and VDD1 supplies.
3 Not production tested.
Table 6. SKY65364-21 Electrical Specifications: Receive and Receive Bypass Mode1 (1 of 2)
(VCC_RX = VDD1 = 3.3 V, VCC_TX1/2/3 = VDD2 = 3.6 V, TC = 25 C, f = 900 to 960 MHz, 50 Ω Source and Load Impedance, CW Input,
RBIAS = 0 Ω, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
Receive Mode: RX2 to Receive Output Path
Small signal gain
G
Noise figure
NF
15
TC = 25 °C,
VCC_RX = 3.3 V
1.5
dB
2.1
dB
Noise figure variation over temperature
NFTEMP
1 dB input compression point (Note 2)
IP1dB
1 dB gain compression
±0.15
dB
–10
dBm
Third order input intercept point (Note 2)
IIP3
PIN = –30 dBm/tone,
200 kHz spacing
Input return loss
|S11|
–3
0
dBm
12
15
dB
Output return loss
|S22|
8
Reverse isolation
|S12|
12
dB
20
dB
Transition time (Note 2)
t
0.5
μs
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
203189F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 24, 2016
5
DATA SHEET • SKY65364-21: T/R FRONT-END MODULE
Table 6. SKY65364-21 Electrical Specifications: Receive and Receive Bypass Mode1 (2 of 2)
(VCC_RX = VDD1 = 3.3 V, VCC_TX1/2/3 = VDD2 = 3.6 V, TC = 25 C, f = 900 to 960 MHz, 50 Ω Source and Load Impedance, CW Input,
RBIAS = 0 Ω, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
3
5
Units
Receive Bypass Mode: RX2 to Receive Output Path
Insertion loss
IL
1 dB input compression point2
IP1dB
1 dB gain compression
Third order input intercept point2
IIP3
PIN = 0 dBm/tone,
200 kHz spacing
Input return loss
+15
|S11|
10
Output return loss
|S22|
10
Transition time2
t
dB
dBm
+27
dBm
18
dB
18
dB
0.5
μs
Receive and Receive Bypass Mode: ANT to RX1 Path
Insertion loss
IL
0.5
1 dB input compression point2
IP1dBANT
1 dB gain compression
Third order input intercept point2
IIP3ANT
PIN = +10 dBm/tone,
200 kHz spacing
Input return loss
|S11|
14
Output return loss
|S22|
14
Transition time2
t
+24
1.0
+30
dBm
+47
dBm
19
dB
19
dB
3.0
μs
1 Performance is guaranteed only under the conditions listed in this table. Modes are established as indicated in Table 2.
2 Not production tested.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
dB
May 24, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203189F
DATA SHEET • SKY65364-21: T/R FRONT-END MODULE
Table 7. SKY65364-21 Electrical Specifications: Transmit Mode1
(VCC_RX = VDD1 = 3.3 V, VCC_TX1/2/3 = VDD2 = 3.6 V, PIN = +12 dBm, VPC = 2.25 V, TC = 25 C, f = 890 to 960 MHz, 50 Ω Source and
Load Impedance, CW Input, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
TX to ANT Path
Output power2
+30
dBm
Output power variation over supply voltage
POUT
TC = 25 °C
TC = 25 °C, VCC_TX1/2/3 = 3.6 V
+29.5
±0.4
dB
Output power variation over temperature
VCC_TX1/2/3 = 3.6 V
±0.3
dB
Output power control
PCTL
VPC = 0 V to 2.25 V3
Small signal transmit PA gain4
GTX
PRF input @ –30 dBm
Power-added efficiency
PAE
2nd harmonic
2fo
–50
dBc
3rd to 10th harmonic5
3fo to 10fo
–50
dBc
Input return loss
|S11|
10
dB
Output return loss
|S22|
8
dB
Non-harmonic spurious4
PSPUR
Power on time4
t
4.4
Insertion loss
IL
1.5
1 dB input compression point4
IP1dB
Third order input intercept point4
IIP3
PIN = +10 dBm/tone, 200 kHz spacing
+47
2nd harmonic
2fo
PIN = +12 dBm
–90
–40
dBc
–90
–40
dBc
40
47
dB
16
dB
40
VSWR 10:1, all phases
%
–50
dBm
μs
TX to ANT Path, Transmit Bypass Mode
rd
+24
2.5
+30
dB
dBm
dBm
3 harmonic
3fo
PIN = +12 dBm
Transmit bypass path rejection
R2FO
@ 2fo (1780 MHz to
1920 MHz)
27
36
dB
R3FO
@ 3fo (2670 MHz to
2880 MHz)
32
36
dB
10
dB
Input return loss
|S11|
Output return loss
|S22|
10
dB
Transition time4
t
3.4
μs
ANT to RX1 Path
Isolation
|S21|
25
35
dB
|S21|
25
35
dB
ANT to RX1 Path, Transmit Bypass Mode
Isolation
1 Performance is guaranteed only under the conditions listed in this table. Modes are established as indicated in Table 2.
2 Output power rated at the antenna output. PA output power is actually 1.5 dB higher or +32 dBm for a POUT of +30.5 dBm.
3 Output power control is the difference between the output power at VPC = 2.25 V and VPC = 0 V.
4 Not production tested.
5 Only the 2nd to 5th harmonics have been production tested. The 6th to 10th harmonics are characterized only.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
203189F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 24, 2016
7
DATA SHEET • SKY65364-21: T/R FRONT-END MODULE
Evaluation Board Description
Package and Handling Information
The SKY65364-21 Evaluation Board is used to test the
performance of the SKY65364-21 T/R FEM. A typical application
schematic diagram is provided in Figure 3. An Evaluation Board
schematic diagram is provided in Figure 4. An assembly drawing
for the Evaluation Board is shown in Figure 5, and the layer detail
is provided in Figure 6.
Since the device package is sensitive to moisture absorption, it is
baked and vacuum packed before shipping. Instructions on the
shipping container label regarding exposure to moisture after the
container seal is broken must be followed. Otherwise, problems
related to moisture absorption may occur when the part is
subjected to high temperature during solder assembly.
The SKY65364-21 is rated to Moisture Sensitivity Level 3 (MSL3)
at 260 C. It can be used for lead or lead-free soldering. For
additional information, refer to Skyworks Application Note, PCB
Design and SMT Assembly/Rework Guidelines for MCM-L
Packages, document number 101752.
Package Dimensions
The footprint drawing and package dimensions are shown in
Figure 7, and tape and reel dimensions are provided in Figure 8.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
3.6 V
220 pF
6
4.7 nF
1 μF
7
8
VDD2
VCC_TX1
VCC_TX2
GND
EN
GND
GND
TX
BYP
GND
VPC
RXO
GND
VCC_RX
ANT
VDD1
GND
9
10
11
12
13
1 μF
23
RBIAS
5
24
RX2
Receive Bypass Mode
Digital Input
Transmit Output
Power Adjust
25
GND
4
TR
VCC_TX3
3
26
GND
Shutdown Mode
Digital Input
27
RX1
2
GND
GND
1
GND
28
Transmit/Receive
Digital Input
1 nF
GND
22
21
50 Ω Line
20
Transmit Input
19
50 Ω Line
18
Receive Output
17
3.3 V
16
220 pF
1 uF
15
14
0Ω
Antenna
50 Ω Line
Antenna
Switch Receive
LNA and Bypass
Switch Output
50 Ω Line
203189E-003
Figure 3. SKY65364-21 Typical Application Schematic
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
May 24, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203189F
DATA SHEET • SKY65364-21: T/R FRONT-END MODULE
14 13
12
11
10
9
8
7
6
5
4
3
2
VCC_RX
GND
GND
VCC_TX1_SENSE
VCC_TX1
GND
GND
VCC_TX23
VCC_TX23_SENSE
GND
TR
EN
BYP
VPC
DCH1 Header
1
C28
10 μF
C27
220 μF
R8
DNI
C12
10 μF
C1
DNI
C7
10 nF
C2
4.7 nF
C8
4.7 nF
L3
0Ω
L4
0Ω
C24
DNI
C26
1 μF
Antenna
6
L5
0Ω
J1
50 Ω Line
7
8
C19
DNI
Antenna
Switch Receive
J2
C25
DNI
N/C
VCC_TX1
VCC_TX2
23
GND
GND
EN
TX
N/C
GND
VPC
RX
GND
N/C
ANT
VDD1
GND
C20
DNI
9
10
11
12
13
N/C
5
TR
24
N/C
R9
0Ω
25
GND
4
26
GND
3
GND
GND
2
27
GND
28
1
C10
DNI
VCC_TX3
C22
DNI
R10
DNI
C15
DNI
C5
220 pF
C23
DNI
C21
DNI
C16
DNI
C11
1 μF
GND
L2
0Ω
C17
DNI
C6
1 nF
C9
4.7 nF
N/C
L1
0Ω
C18
DNI
R7
0Ω
GND
22
21
Transmit Input
19
J4
50 Ω Line
18
Receive Output
17
16
C3
220 pF
C4
1 uF
15
R5
0Ω
14
50 Ω Line
J5
50 Ω Line
20
50 Ω Line
J3
LNA and Bypass
Switch Output
Notes:
Some component labels may be different from the corresponding component symbol shown here.
Component values, however, are accurate as of the date of this data sheet.
PCB Recommendations:
Metal Layer 1 = RF traces + control lines. Core thickness between top RF layer and ground plane is critical.
Metal Layer 2 = Solid ground plane. No traces routing.
Metal Layer 3 and 4 = Control lines + VCC traces (no VCC plane).
Pour copper on each layer connected to the ground plane. Use VCC traces in a star distribution pattern.
Always use 4 layers.
203189E-004
Figure 4. SKY65364-21 Evaluation Board Schematic
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
203189F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 24, 2016
9
DATA SHEET • SKY65364-21: T/R FRONT-END MODULE
203189E-005
Figure 5. SKY65364-21 Evaluation Board Assembly Diagram
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
10
May 24, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203189F
DATA SHEET • SKY65364-21: T/R FRONT-END MODULE
Layer 1: Top – Metal
Layer 3: Ground
Layer 2: Ground
Layer 4: Solid Ground Plane
203189E-006
Figure 6. SKY65364-21 Evaluation Board Layer Detail
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
203189F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 24, 2016
11
DATA SHEET • SKY65364-21: T/R FRONT-END MODULE
0.5
0.4
0.05 0.05
0.15
Stencil aperture size for center
ground pads should be 80% to
100% (by area) of the solder
mask opening of the package.
6.3
0.8 0.9
Stencil and
Metallization
8X 0.062
Package Outline
Solder Mask Opening
6.3
16X 0.875
SMT Pad Detail
Scale: 2X
6X This Rotation
6X Rotated 180°
6X Rotated 90° CW
6X Rotated 90° CCW
Package Outline
8X 0.063
16X 0.875
Stencil Aperture
Top View
6.4
3.875
0.9
0.8
0.05
0.05
0.15
0.85 0.75
Package Outline
6.4 3.875
Stencil and
Metallization
Package Outline
Solder Mask Opening
SMT Pad Detail
Scale: 2X
1X This Rotation
1X Rotated 180°
Solder Mask Opening
Top View
(6.3)
(1.5)
Pin 28
0.25 Typ.
Pin 1
The cross-hatched area represents the merger
of the center ground pad +12 individual I/O
ground pads. All I/O ground pads should have
at least one via connected to internal ground
planes for optimum electrical performance.
0.9
0.8
Package Outline
(10X 0.75 Pitch)
(6.3)
0
4X 0.375
(1.2)
0.05
0.05
0.75 0.85
0.15
4X 1.125
4X 1.875
Stencil and
Metallization
2X 2.750
Package Outline
Solder Mask Opening
Metallization
Top View
2X 2.750
4X 1.813
4X 1.088
0
4X 0.363
(10X 0.725 Pitch)
Thermal Via Array.
∅0.3 mm on 0.6 mm pitch.
Additional vias in common ground
pad will improve thermal and electrical
performance. NOTE: thermal vias
should be tented and filled with solder
mask, 30-35 μm Cu plating recommended.
SMT Pad Detail
Scale: 2X
1X This Rotation
1X Rotated 180°
203189E-007
All measurements are in millimeters
Figure 7. SKY65364-21 Footprint Drawing and Package Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
12
May 24, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203189F
DATA SHEET • SKY65364-21: T/R FRONT-END MODULE
∅1.50 ± 0.10
0.25 ± 0.02 (T)
4.00 ± 0.10
2.00 ± 0.10
1.75 ± 0.10
6.35 ± 0.10 (Bo)
A
A
B
1.30 ± 0.10 (Ko)
12.00 ± 0.20
B
5.50 ± 0.10
Pin 1 Indicator
∅1.55 ± 0.05
8.00 ± 0.10
B
6.35 ± 0.10 (Ao)
Notes:
1.
2.
3.
4.
5.
Carrier tape: black conductive polycarbonate or polystyrene.
Cover tape material: transparent conductive PSA.
Cover tape size: 9.3 mm width.
All dimensions are in millimeters.
ESD-surface resistivity is ≤1 x 1010 Ohms/square per EIA, JEDEC
TNR Specification.
A
203189E-008
Figure 8. SKY65364-21 Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
203189F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • May 24, 2016
13
DATA SHEET • SKY65364-21: T/R FRONT-END MODULE
Ordering Information
Model Name
SKY65364-21: T/R Front-End Module
Manufacturing Part Number
SKY65364-21
Evaluation Board Part Number
SKY65364-21-EK1
Copyright © 2012, 2014-2016 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of
Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for
identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by
reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
14
May 24, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203189F