LIA135

Reliability Report
(Q2014-002)
LIA135/LIA136 Product Qualification
Optically Isolated Amplifier
October 1, 2015
IXYS Integrated Circuits Division
78 Cherry Hill Drive, Beverly, MA 01915
www.ixysic.com
LIA135/LIA136
Optically Isolated Amplifier
Summary
The LIA135 and LIA136 products have successfully passed IXYS ICD’s requirements for product
qualification.
Table 1: Device Information
Product Number
Package Type
Assembly Site
Test Site
LIA135, LIA136
8L DIP
Atec, Laguna, Philippines
IXYS ICD BEV, Beverly, MA, USA
Table 2: Reliability Test Result
Stress
Test
HTRB
HAST
Thermal
Shock
Temperature
Cycle
Hot Storage
MSL
Stress
Conditions
125°C,
80% WVDC,
1000 hrs
130°C,
85%,
18.8PSI,
96 hrs
0 to 100°C,
10/10 dwells,
15 cycles
-55 to 125°C,
10/10 dwells,
300 cycles
125C,
1000 hrs
IR Reflow,
Level 1
Product/
Applicable Specs Package
Mil-Std-883
LIA135/
M1005
TE3524
JESD22-A-108
LIA135/
Sample # of
Size (SS) Failures
105
0
112
0
105
0
77
0
80
0
55
0
Mil-Std-883,
M1011
TE3500
LIA136/
TE3513
LIA135/
TE3458
LIA136/
TE3483
LIA135/
TE3458
Mil-Std-883,
M1010, “B”
LIA135/
TE3458
55
0
JESD22-A103-C
LIA135/
TE3458
LIA135/
TE3500
LIA135/
TE3524
LIA135/
TE3525
LIA136/
TE3513
LIA135/
TE3458
50
0
50
0
50
0
50
0
50
0
50
0
JESD22A110-C
J-STD-020D.1
IXYS Integrated Circuits Division, Beverly, MA, USA
Report# Q2014-004
Page 2 of 4
LIA135/LIA136
Optically Isolated Amplifier
Table 3: ESD Results – 8-Pin DIP
Stress
Test
Stress
Conditions
HBM
All Pins,
1.5kΩ,
100pF
Applicable Specs
Product/
Package
Highest
Passed
Class
JESD22A114-E
LIA135/
TE3458
+/-2000V
2
LIA136/
TE3483
+/-2000V
2
Table 4: FIT Rate Summary
Qual
Lot #
1
Stress
Test
HTRB
# of
Devices
322
1
HAST
157
# of
Fail
0
Hours
Tested
1000
Equivalent
Dev. Hours
82,240,721
0
96
17,839,281
FIT Rate
@ 60% CL
11.19*
51.57**
* HTRB FIT Rate was calculated based on the Acceleration Factor (AF) and equivalent device hours at
0.7eV of activation energy at 125°C test temperature and 40°C use temperature.
** HAST FIT Rate was calculated based on the Acceleration Factor (AF) and equivalent device hours at
0.7eV of activation energy at 130°C test temperature and 40°C use temperature.
IXYS Integrated Circuits Division, Beverly, MA, USA
Report# Q2014-004
Page 3 of 4
LIA135/LIA136
Optically Isolated Amplifier
Approvals
Prepared by:
_Martha W, Brandt*_________________________________10/1/15__
Martha W. Brandt
Date
Quality Engineer
Approved by:
_George Belezos*___________________________________10/1/15__
George Belezos
Date
Quality Manager
Approved by:
_James Archibald*___________________________________10/1/15__
James Archibald
Date
Director of Engineering
*Signature on File
IXYS Integrated Circuits Division, Beverly, MA, USA
Report# Q2014-004
Page 4 of 4