Baumer R02 RTD Assembly with N-U-N Connection Special Features Mineral insulated cable. Spring loaded design for positive contact with thermowell Available in various connections & sheath diameters Enclosures (Head) Weatherproof IP - 67 Flameproof Gr. lIA, llB Explosion proof lIA, llB, IIC Transmitter output 4 - 20 mA (Optional) Reference Standard : IEC - 751 / DIN 43760 Application Such design is generally used in all industries, machinery manufactures, bearing temp. measurement etc. where space is limited. GOST - R GOST Specifications Standard Version No of element Element type Range Accuracy Wire configuration Sheath diameter Sheath material Terminal head type No. of conduit entry Cable gland Head extension type Immersion length "IL"mm Process conn. “P” Tag plate : : : : : : : : : : : : : : Simplex Pt - 100 -200°C till 450°C Class ‘B’ tolerance as per IEC - 751 / DIN 43760 3 Wire system 6.0 mm SS 316 Screwed type, weatherproof, IP-65 in Die Cast Aluminum One 3/4" ET, Nickel plated brass, single compression Head with nipple union nipple extension 150 mm. ½” BSP (M), SS 316 Aluminum tag plate Dimensional Details Design and specifications subject to change without notice Terminal Head IL N Mineral Insulated RTD Cable We Measure We Control "P" Nipple-Union-Nipple Extension Conduit entry (Cadmium Plated CS) Notes : • Drawings are not to scale. www.baumer.com 31- 08 -12 Nipple - Union - Nipple Connection • All Dimensions are in mm. Page 1 / 2 Baumer R02 RTD Assembly with N-U-N Connection How To Order Example Basic Model R02 A C Optional Extras No of Element X Elements Type Pt- 100 (Standard) Pt- 500 Pt - 1000 XX -200°C till 450°C X Class ‘A’ Class ‘B’ (Standard) X 2 Wire system 4 Wire system 3 3 Wire system (Standard) X Sheath Diameter 03 05 3.0 mm 4.5 mm 06 08 6.0 mm (Standard) 8.0 mm XX Sheath Material 1 SS 316 (Standard) 2 SS 316L Terminal Head Type F E H B A 3 4 5 Screwed type, Flameproof, IP-67, Gr. IIA IIB in Die Cast Aluminum Screwed type, Explosion proof, IP-67, Gr. IIC in Die Cast Aluminum Hinged type, Weatherproof, IP-67 in Die Cast Aluminum Weatherproof Head, IP-67 in Die Cast Aluminum with cover fitted with two screws. Screwed type, weatherproof, IP-65 in Die Cast Aluminum (Standard) Terminal head in SS 304 - WP, IP-67 Terminal head in SS 316 - WP, IP-67 Terminal head in cast iron, IP-65 X X No of Conduit Entry / Entries 1 2 E U N Head with nipple extension Head with nipple union extension Head with nipple union nipple extension X Immersion Length / Element Length 150mm 4NM 4NF 4BM 4BF ½”NPT (M) ½”NPT (F) ½”BSP (M) (Standard) ½”BSP (F) 5NM 5NF 5BM 5BF 3/4” NPT (M) 3/4” NPT (F) 3/4” BSP (M) 3/4” BSP (F) XXX Other Options Wire Configuration 2 4 X Process conn. “P” Accuracy A B 1/2” NPT(F) B IL - Specify in mm. Range C 3/4” ET (Standard) 3/4” NPT(F) Head Extension Type Simplex (Standard) Duplex P1 P2 P3 Example One entry (Standard) Double entry X 13 14 21 22 23 32 33 34 35 36 37 38 39 40 41 42 43 EC E4 E6 UC U4 U6 NC N4 N6 AC PW SX Head mounted transmitter (4-20 mA) SS base plate suitable for temperature transmitter mounting Plug for conduit entry in carbon steel Plug for conduit entry in SS 304 Plug for conduit entry in SS 316 S. C. cable gland in nickel plated brass - WP D. C. cable gland in nickel plated brass - WP S. C. cable gland in SS 304 - WP D. C. cable gland in SS 304 - WP S. C. cable gland in SS 316 - WP D. C. cable gland in SS 316 - WP S. C. cable gland in nickel plated brass - FLP D. C. cable gland in nickel plated brass - FLP S. C. cable gland in SS 304 - FLP D. C. cable gland in SS 304 - FLP S. C. cable gland in SS 316 - FLP D. C. cable gland in SS 316 - FLP Head with nipple extension 50 mm in CS Head with nipple extension 50 mm in SS 304 Head with nipple extension 50 mm in SS 316 Head with nipple extension 100 mm in CS Head with nipple extension 100 mm in SS 304 Head with nipple extension 100 mm in SS 316 Head with nipple extension 150 mm in CS Head with nipple extension 150 mm in SS 304 Head with nipple extension 150 mm in SS 316 Adjustable threaded connection Calibration certificate SS tag plate Note : 1. When selecting option “PW”, please also specify temp. Points at which calibration is to be carried out . 2. Explanations of Abbreviations used: SC = Single Compression SS = Stainless Steel DC = Double Compression FLP = Flameproof XX Design and specifications subject to change without notice 1 2 How To Order Cable Gland WP = Weatherproof 31- 08 -12 Ordering Example : R02 . X . XX. X . X . X . XX . X . X . X . X . X . 150 mm . XXX . XX Note : Specifications and dimensions given in this product catalogue represents the state of engineering at the time of printing. Modifications may take place and materials specified may be replaced by others without prior notice. www.baumer.com Page 2 / 2