Technical Data

Baumer
R02
RTD Assembly with N-U-N Connection
Special Features
Mineral insulated cable.
Spring loaded design for positive contact with thermowell
Available in various connections & sheath diameters
Enclosures (Head)
Weatherproof IP - 67
Flameproof Gr. lIA, llB
Explosion proof lIA, llB, IIC
Transmitter output 4 - 20 mA (Optional)
Reference Standard : IEC - 751 / DIN 43760
Application
Such design is generally used in all industries, machinery
manufactures, bearing temp. measurement etc. where space is
limited.
GOST - R
GOST
Specifications
Standard Version
No of element
Element type
Range
Accuracy
Wire configuration
Sheath diameter
Sheath material
Terminal head type
No. of conduit entry
Cable gland
Head extension type
Immersion length "IL"mm
Process conn. “P”
Tag plate
:
:
:
:
:
:
:
:
:
:
:
:
:
:
Simplex
Pt - 100
-200°C till 450°C
Class ‘B’ tolerance as per IEC - 751 / DIN 43760
3 Wire system
6.0 mm
SS 316
Screwed type, weatherproof, IP-65 in Die Cast Aluminum
One
3/4" ET, Nickel plated brass, single compression
Head with nipple union nipple extension
150 mm.
½” BSP (M), SS 316
Aluminum tag plate
Dimensional Details
Design and specifications subject to change without notice
Terminal Head
IL
N
Mineral Insulated RTD Cable
We Measure
We Control
"P"
Nipple-Union-Nipple Extension
Conduit entry
(Cadmium Plated CS)
Notes : • Drawings are not to scale.
www.baumer.com
31- 08 -12
Nipple - Union - Nipple Connection
• All Dimensions are in mm.
Page 1 / 2
Baumer
R02
RTD Assembly with N-U-N Connection
How To Order
Example
Basic Model
R02
A
C
Optional Extras
No of Element
X
Elements Type
Pt- 100 (Standard)
Pt- 500
Pt - 1000
XX
-200°C till 450°C
X
Class ‘A’
Class ‘B’ (Standard)
X
2 Wire system
4 Wire system
3
3 Wire system (Standard)
X
Sheath Diameter
03
05
3.0 mm
4.5 mm
06
08
6.0 mm (Standard)
8.0 mm
XX
Sheath Material
1 SS 316 (Standard)
2 SS 316L
Terminal Head Type
F
E
H
B
A
3
4
5
Screwed type, Flameproof, IP-67, Gr. IIA IIB in
Die Cast Aluminum
Screwed type, Explosion proof, IP-67, Gr. IIC in
Die Cast Aluminum
Hinged type, Weatherproof, IP-67 in Die Cast
Aluminum
Weatherproof Head, IP-67 in Die Cast Aluminum
with cover fitted with two screws.
Screwed type, weatherproof, IP-65 in Die Cast
Aluminum (Standard)
Terminal head in SS 304 - WP, IP-67
Terminal head in SS 316 - WP, IP-67
Terminal head in cast iron, IP-65
X
X
No of Conduit Entry / Entries
1
2
E
U
N
Head with nipple extension
Head with nipple union extension
Head with nipple union nipple extension
X
Immersion Length / Element Length
150mm
4NM
4NF
4BM
4BF
½”NPT (M)
½”NPT (F)
½”BSP (M) (Standard)
½”BSP (F)
5NM
5NF
5BM
5BF
3/4” NPT (M)
3/4” NPT (F)
3/4” BSP (M)
3/4” BSP (F)
XXX
Other Options
Wire Configuration
2
4
X
Process conn. “P”
Accuracy
A
B
1/2” NPT(F)
B
IL - Specify in mm.
Range
C
3/4” ET (Standard)
3/4” NPT(F)
Head Extension Type
Simplex (Standard)
Duplex
P1
P2
P3
Example
One entry (Standard)
Double entry
X
13
14
21
22
23
32
33
34
35
36
37
38
39
40
41
42
43
EC
E4
E6
UC
U4
U6
NC
N4
N6
AC
PW
SX
Head mounted transmitter (4-20 mA)
SS base plate suitable for temperature transmitter
mounting
Plug for conduit entry in carbon steel
Plug for conduit entry in SS 304
Plug for conduit entry in SS 316
S. C. cable gland in nickel plated brass - WP
D. C. cable gland in nickel plated brass - WP
S. C. cable gland in SS 304 - WP
D. C. cable gland in SS 304 - WP
S. C. cable gland in SS 316 - WP
D. C. cable gland in SS 316 - WP
S. C. cable gland in nickel plated brass - FLP
D. C. cable gland in nickel plated brass - FLP
S. C. cable gland in SS 304 - FLP
D. C. cable gland in SS 304 - FLP
S. C. cable gland in SS 316 - FLP
D. C. cable gland in SS 316 - FLP
Head with nipple extension 50 mm in CS
Head with nipple extension 50 mm in SS 304
Head with nipple extension 50 mm in SS 316
Head with nipple extension 100 mm in CS
Head with nipple extension 100 mm in SS 304
Head with nipple extension 100 mm in SS 316
Head with nipple extension 150 mm in CS
Head with nipple extension 150 mm in SS 304
Head with nipple extension 150 mm in SS 316
Adjustable threaded connection
Calibration certificate
SS tag plate
Note :
1. When selecting option “PW”, please also specify temp. Points at which calibration is to be carried out .
2. Explanations of Abbreviations used:
SC = Single Compression SS = Stainless Steel DC = Double Compression FLP = Flameproof
XX
Design and specifications subject to change without notice
1
2
How To Order
Cable Gland
WP = Weatherproof
31- 08 -12
Ordering Example : R02 . X . XX. X . X . X . XX . X . X . X . X . X . 150 mm . XXX . XX
Note : Specifications and dimensions given in this product catalogue represents the state of engineering at the time of
printing. Modifications may take place and materials specified may be replaced by others without prior notice.
www.baumer.com
Page 2 / 2