Features:
Pure Sine-Output VCXO
Low Height: 0.155’ max
Low-g: < 0.3ppb/g worst case axis option available
Compatible with automated assembly processes; including post reflow aqueous and non-aqueous cleaning
Applications:
Avionics
SatCom
Cyber security and communication systems
Electrical Specifications for Representative 125MHz VCXO:
Parameter
Nominal Frequency
vs. Temperature Range
vs. Supply Voltage
vs. Load
Aging 1st Year
Output Type
Output Load
Level
Method
Tuning Slope
Tuning Voltage
Tuning Range
Modulation Bandwidth
Input Impedance
SSB Phase Noise Under Static
Conditions
G-Sensitivity
Warm-up Time
Unless otherwise specified; T= +25°C, VS = +5VDC, VC = +2.5VDC, Load= 50Ω
Symbol
Min.
Typ.
Max.
Units
FO
10
300
MHz
Frequency Stabilities
-20
+20
ppm
-0.5
+0.5
ppm
-0.5
+0.5
ppm
-1.0
+1.0
ppm
RF Output
Sinewave
50
Ω
-3
0
+3
dBm
Frequency Adjustment
External Voltage Tuned
Negative
VTUNE
0
+5
VDC
-25
+25
ppm
3
kHz
10
KΩ
Other Parameters
-70
-97
-127
-150
-150
0.5
ppb/g
ΔF/F
Harmonics
Spurious
Supply Voltage
VS
5
Minutes
-20
-90
dBc
dBc
3
mA
-40
+85
°C
-55
+105
°C
Supply Voltage & Power Consumption
4.75
5.0
5.25
Current Draw
Conditions
-40°C to +85°C
±5% change in voltage
±5% change in load
±10%
In a 50Ω load
@ 10Hz Offset
@ 100Hz Offset
@ 1kHz Offset
@ 10kHz Offset
@ 100kHz Offset
Worst case axis
To be within ±100ppb, @ 25˚C,
referenced to the frequency
after 24-hour power on
VDC
Environmental Conditions:
Operating Temperature
OT
Non-Operating Temperature
1 of 2
The information contained herein is proprietary to MtronPTI and is submitted in confidence.
This information may not be copied or divulged without written permission from MtronPTI.
MtronPTI XO7080 Pure Sine Output SMT VCXO
P/N: XO7080-xxx
Shock and Vibration:
Three (3) ½ sine shock pulses of the given force and duration on each of the three (3) axis. The VCXO shall operate during and after the shock
pulses.
Direction: Force
Duration (msec)
Vertical: 160 G’s
3 to 5
Front to Back: 80 G’s
3 to 5
Side to Side: 80 G’s
3 to 5
VCXO shall operate for periods up to 2-hours duration when subjected to any of the vibration in the given ranges, with the corresponding input
amplitude listed. The requirement shall be met regardless of the direction of the vibration.
Frequency (Hz)
4 – 15
16 - 25
26 - 33
Input Amplitude (inches)
0.04 ±0.008
0.03 ±0.006
0.04 ±0.008
Figure 1 - XO7080 Outline Drawing
Figure 2 – Recommended PAD Layout
Data Sheet Revision Table:
Date
Rev.
12-28-15
A
Orig.
DD
Figure 3 – Recommended Reflow Profile
Details of Revision
Preliminary Draft
2 of 2
The information contained herein is proprietary to MtronPTI and is submitted in confidence.