User's Guide True RMS Multimeter plus IR Thermometer Extech 470 Introduction Congratulations on your purchase of the Extech 470 (part number EX470) True RMS Autoranging Multimeter plus IR Thermometer. This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency, Duty Cycle, Diode Test, and Continuity plus Thermocouple and Non-Contact IR Temperature. Proper use and care of this meter will provide many years of reliable service. Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present Double insulation WARNING This WARNING symbol indicates a potentially hazardous situation, which if not avoided, could result in death or serious injury. CAUTION This CAUTION symbol indicates a potentially hazardous situation, which if not avoided, may result damage to the product. MAX 600V This symbol advises the user that the terminal(s) so marked must not be connected to a circuit point at which the voltage with respect to earth ground exceeds (in this case) 600 VAC or VDC. This symbol indicates there is a potential hazard from a laser light source. 2 EX470-en-GB_v5.6 4/15 CAUTIONS Improper use of this meter can cause damage, shock, injury or death. Read and understand this user manual before operating the meter. Always remove the test leads before replacing the battery or fuses. Inspect the condition of the test leads and the meter itself for any damage before operating the meter. Repair or replace any damage before use. Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC. These voltages are considered a shock hazard. Always discharge capacitors and remove power from the device under test before performing Diode, Resistance or Continuity tests. Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty of connection to the recessed electrical contacts. Other means should be used to ensure that the terminals are not "live". If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. This device is not a toy and must not reach children’s hands. It contains hazardous objects as well as small parts that the children could swallow. In case a child swallows any of them, please contact a physician immediately Do not leave batteries and packing material lying around unattended; they can be dangerous for children if they use them as toys In case the device is going to be unused for an extended period of time, remove the batteries to prevent them from training Expired or damaged batteries can cause cauterization on contact with the skin. Always, therefore, use suitable hand gloves in such cases See that the batteries are not short-circuited. Do not throw batteries into the fire. Do not directly view or direct the laser pointer at an eye. Low power visible lasers do not normally present a hazard, but may present some potential for hazard if viewed directly for extended periods of time 3 EX470-en-GB_v5.6 4/15 OVERVOLTAGE CATEGORY III This meter meets the IEC 610-1-2001 standard for OVERVOLTAGE CATEGORY III. Cat III meters are protected against overvoltage transients in fixed installation at the distribution level. Examples include switches in the fixed installation and some equipment for industrial use with permanent connection to the fixed installation. SAFETY INSTRUCTIONS This meter has been designed for safe use, but must be operated with caution. The rules listed below must be carefully followed for safe operation. 1. NEVER apply voltage or current to the meter that exceeds the specified maximum: Input Protection Limits Function V DC or V AC mA AC/DC A AC/DC Frequency, Resistance, Capacitance, Duty Cycle, Diode Test, Continuity Temperature 2. 3. 4. 5. 6. 7. 8. Maximum Input 1000VDC/750AC, 200Vrms on 400mV range 500mA 250V fast acting fuse 20A 250V fast acting fuse(30 seconds max every 15 minutes) 250Vrms for 15sec max 60V DC/24V AC USE EXTREME CAUTION when working with high voltages. DO NOT measure voltage if the voltage on the "COM" input jack exceeds 600V above earth ground. NEVER connect the meter leads across a voltage source while the function switch is in the current, resistance, or diode mode. Doing so can damage the meter. ALWAYS discharge filter capacitors in power supplies and disconnect the power when making resistance or diode tests. ALWAYS turn off the power and disconnect the test leads before opening the covers to replace the fuse or batteries. NEVER operate the meter unless the back cover and the battery and fuse covers are in place and fastened securely. NEVER look directly at the laser light source or aim the pointer at an eye. 4 EX470-en-GB_v5.6 4/15 Controls and Jacks 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. IR Thermometer and laser pointer 4000 count LCD display HOLD and Backlight button SELECT button Function switch mA, uA and A input jacks COM input jack Positive input jack RANGE hold button RELATIVE button Laser pointer button Protective holster Note: Tilt stand and battery compartment are on rear of unit. Symbols and Annunciators •))) Continuity Diode test Laser pointer Battery status n µ m k M Hz % AC DC ºF Test lead connection error -9 nano (10 ) (capacitance) -6 micro (10 ) (amps, cap) -3 milli (10 ) (volts, amps) 3 kilo (10 ) (ohms) 6 mega (10 ) (ohms) Hertz (frequency) Percent (duty ratio) Alternating current Direct current Degrees Fahrenheit A F V REL AUTO HOLD ºC Amps Farads (capacitance) Ohms Volts Relative Autoranging Display hold Degrees Centigrade 5 EX470-en-GB_v5.6 4/15 Operating Instructions WARNING: Risk of electrocution. High-voltage circuits, both AC and DC, are very dangerous and should be measured with great care. 1. ALWAYS turn the function switch to the OFF position when the meter is not in use. 2. If “OL” appears in the display during a measurement, the value exceeds the range you have selected. Change to a higher range. NOTE: On some low AC and DC voltage ranges, with the test leads not connected to a device, the display may show a random, changing reading. This response is normal and is caused by the highinput sensitivity. The reading will stabilize and give a proper measurement when connected to a circuit. DC VOLTAGE MEASUREMENTS CAUTION: Do not measure DC voltages if a motor on the circuit is being switched ON or OFF. Large voltage surges may occur that can damage the meter. 1. Set the function switch to the green V position. 2. Press the SELECT button to indicate “DC” on the display. 3. Insert the black test lead banana plug into the negative COM jack. Insert the red test lead banana plug into the positive V jack. 4. Touch the black test probe tip to the negative side of the circuit. Touch the red test probe tip to the positive side of the circuit. 5. Read the voltage in the display. 6 EX470-en-GB_v5.6 4/15 AC VOLTAGE MEASUREMENTS WARNING: Risk of Electrocution. The probe tips may not be long enough to contact the live parts inside some 240V outlets for appliances because the contacts are recessed deep in the outlets. As a result, the reading may show 0 volts when the outlet actually has voltage on it. Make sure the probe tips are touching the metal contacts inside the outlet before assuming that no voltage is present. CAUTION: Do not measure AC voltages if a motor on the circuit is being switched ON or OFF. Large voltage surges may occur that can damage the meter. 1. Set the function switch to the green V position. 2. Press the SELECT button to indicate “AC” on the display. 3. Insert the black test lead banana plug into the negative COM jack. Insert red test lead banana plug into the positive V jack. 4. Touch the black test probe tip to the neutral side of the circuit. Touch the red test probe tip to the “hot” side of the circuit. 5. Read the voltage in the display. DC CURRENT MEASUREMENTS CAUTION: Do not make current measurements on the 20A scale for longer than 30 seconds. Exceeding 30 seconds may cause damage to the meter and/or the test leads. 1. Insert the black test lead banana plug into the negative COM jack. 2. For current measurements up to 4000µA DC, set the function switch to the yellow µA position and insert the red test lead banana plug into the µA/mA jack. 3. For current measurements up to 400mA DC, set the function switch to the yellow mA position and insert the red test lead banana plug into the µA/mA jack. 4. For current measurements up to 20A DC, set the function switch to the yellow A range and insert the red test lead banana plug into the A jack. 5. Press the SELECT button to indicate “DC” on the display. 6. Remove power from the circuit under test, then open up the circuit at the point where you wish to measure current. 7. Touch the black test probe tip to the negative side of the circuit. Touch the red test probe tip to the positive side of the circuit. 8. Apply power to the circuit. 9. Read the current in the display. 7 EX470-en-GB_v5.6 4/15 AC CURRENT MEASUREMENTS CAUTION: Do not make current measurements on the 20A scale for longer than 30 seconds. Exceeding 30 seconds may cause damage to the meter and/or the test leads. 1. Insert the black test lead banana plug into the negative COM jack. 2. For current measurements up to 4000µA AC, set the function switch to the yellow µA position and insert the red test lead banana plug into the µA/mA jack. 3. For current measurements up to 400mA AC, set the function switch to the yellow mA position and insert the red test lead banana plug into the µA/mA jack. 4. For current measurements up to 20A AC, set the function switch to the yellow A range and insert the red test lead banana plug into the A jack. 5. Press the SELECT button to indicate “AC” on the display. 6. Remove power from the circuit under test, then open up the circuit at the point where you wish to measure current. 7. Touch the black test probe tip to the neutral side of the circuit. Touch the red test probe tip to the “hot” side of the circuit. 8. Apply power to the circuit. 9. Read the current in the display. RESISTANCE MEASUREMENTS WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements. Remove the batteries and unplug the line cords. 1. Set the function switch to the green Ω position. 2. Insert the black test lead banana plug into the negative COM jack. Insert the red test lead banana plug into the positive jack. 3. Press the SELECT button to indicate “"on the display. 4. Touch the test probe tips across the circuit or part under test. It is best to disconnect one side of the part under test so the rest of the circuit will not interfere with the resistance reading. 5. Read the resistance in the display. 8 EX470-en-GB_v5.6 4/15 CONTINUITY CHECK WARNING: To avoid electric shock, never measure continuity on circuits or wires that have voltage on them. 1. Set the function switch to the green Ω position. 2. Insert the black lead banana plug into the negative COM jack. Insert the red test lead banana plug into the positive jack. 3. Press the SELECT button to indicate” "and “Ω” on the display 4. Touch the test probe tips to the circuit or wire you wish to check. 5. If the resistance is less than approximately 150, the audible signal will sound. If the circuit is open, the display will indicate “OL”. DIODE TEST 1. Set the function switch to the green Ω position. 2. Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive V jack. 3. Press the SELECT button to indicate and V on the display. 4. Touch the test probes to the diode under test. Forward voltage will typically indicate 0.400 to 0.700V. Reverse voltage will indicate “OL”. Shorted devices will indicate near 0V and an open device will indicate “OL” in both polarities. 9 EX470-en-GB_v5.6 4/15 CONTACT TEMPERATURE MEASUREMENTS 1. Set the function switch to the black Type K ºC or ºF position. 2. Insert the Temperature Probe into the input jacks, making sure to observe the correct polarity. 3. Touch the Temperature Probe head to the part whose temperature you wish to measure. Keep the probe touching the part under test until the reading stabilizes (about 30 seconds). 4. Read the temperature in the display. Note: The temperature probe is fitted with a type K mini connector. A mini connector to banana connector adaptor is supplied for connection to the input banana jacks. NON-CONTACT TEMPERATURE MEASUREMENTS 1. Set the function switch to the red IR Non-Contact ºC or ºF position. 2. Point the meter at the surface to be measured. 3. If needed, press the red IR Laser Pointer button to locate the exact spot being measured. 4. The area of the surface to be measured must be larger than the spot size as determined by the distance to spot size specification. 5. Read the temperature in the display. Diameter of Spot (2.5cm) (20cm) (40cm) (5cm) (10cm) (80cm) Distance to Object WARNING: Do not directly view or direct the laser pointer at an eye. Low power visible lasers do not normally present a hazard, but may present some potential for hazard if viewed directly for extended periods of time. 10 EX470-en-GB_v5.6 4/15 CAPACITANCE MEASUREMENTS WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any capacitance measurements. Remove the batteries and unplug the line cords. 1. Set the rotary function switch to the green position. 2. Insert the black test lead banana plug into the negative (COM) jack. Insert the red test lead banana plug into the positive jack. 3. Touch the test leads to the capacitor to be tested. 4. Read the capacitance value in the display FREQUENCY MEASUREMENTS 1. Set the rotary function switch to the green “Hz” position. 2. Insert the black lead banana plug into the negative COM jack and the red test lead banana plug into the positive Hz jack. 3. Touch the test probe tips to the circuit under test. 4. Read the frequency on the display. % DUTY CYCLE 1. Set the rotary function switch to the “Hz” position. 2. Insert the black lead banana plug into the negative COM jack and the red test lead banana plug into the positive Hz jack. 3. Press the SELECT key momentarily to select “%” in the display. 4. Touch the test probe tips to the circuit under test. 5. Read the % duty cycle on the display. 11 EX470-en-GB_v5.6 4/15 AUTORANGING/MANUAL RANGE SELECTION When the meter is first turned on, it automatically goes into AutoRanging. This automatically selects the best range for the measurements being made and is generally the best mode for most measurements. For measurement situations requiring that a range be manually selected, perform the following: 1. 2. 3. Press the RANGE key. The “AUTO” display indicator will turn off. Press the RANGE key to step through the available ranges until you select the range you want. To exit the Manual Ranging mode and return to AutoRanging, press and hold the RANGE key for 2 seconds. Note: Manual ranging does not apply for the Capacitance, Frequency and Temperature functions. RELATIVE MODE The relative measurement feature allows you to make measurements relative to a stored reference value. A reference voltage, current, etc. can be stored and measurements made in comparison to that value. The displayed value is the difference between the reference value and the measured value. 1. Perform the measurement as described in the operating instructions. 2. Press the REL button to store the reading in the display and the "REL" indicator will appear on the display. 3. The display will now indicate the difference between the stored value and the measured value. 4. Press the REL button to exit the relative mode. Note: The Relative function does not operate in the Frequency function. DISPLAY BACKLIGHT Press and hold the HOLD key for >1 second to turn on or off the display backlight function. Note: The HOLD feature will activate when the Backlight is turned on. Press the HOLD key again to exit Hold. HOLD The hold function freezes the reading in the display. Press the HOLD key momentarily to activate or to exit the HOLD function. AUTO POWER OFF The auto off feature will turn the meter off after 15 minutes. LOW BATTERY INDICATION The icon will appear in the lower left conner of the display when the battery voltage becomes low. Replace the battery when this appears. WRONG CONNECTION INDICATION The icon will appear in the upper right conner of the display and the buzzer will sound whenever the positive test lead is inserted into the 20A or uA/mA input jack and a non-current (green, black or red) function is selected. If this occurs, turn the meter off and reinsert the test lead into the proper input jack for the function selected. 12 EX470-en-GB_v5.6 4/15 Specifications Function DC Voltage Range 400mV Resolution 0.1mV Accuracy 4V 40V 400V 1000V 0.001V 0.01V 0.1V 1V 400mV 0.1mV 4V 40V 400V 750V 0.001V 0.01V 0.1V 1V 400A 0.1A 4000A 40mA 400mA 4A 20A 1A 0.01mA 0.1mA 0.001A 0.01A 400A 0.1A 4000A 40mA 400mA 4A 20A 400 1A 0.01mA 0.1mA 0.001A 0.01A 0.1 (0.8% reading + 4 digits) 4k 0.001k (0.8% reading + 2 digits) 40k 0.01k 400k 0.1k 4M 0.001M 40M 40nF 0.01M 0.01nF (3.0% reading + 5 digits) 400nF 0.1nF (3.0% reading + 5 digits) (0.3% reading + 2 digits) (0.5% reading + 2 digits) (0.8% reading + 3 digits) 50 to 400Hz 400Hz to 1kHz AC Voltage DC Current (1.5% reading + 15 digits) (1.5% reading + 6 digits) (1.8% reading + 6 digits) Capacitance (3% reading + 8 digits) (2.5% reading + 5 digits) 50 to 400Hz 400Hz to 1KHz (1.8% reading + 8 digits) (3.0% reading + 7 digits) (3.0% reading + 8 digits) (3.5% reading + 10 digits) (1.0% reading + 2 digits) 4F 0.001F 40F 0.01F (5.0% reading + 7 digits) (3.5% reading + 5 digits) 100F 0.1F (5.0% reading + 5 digits) Temp (type-K) -20 to 750C 1C -4 to 1382F 1F (3.0% reading + 3 digits) (probe accuracy not included) Temp (IR) -50 to 270C 1C -58 to 518F 1F o (2.5% reading + 8 digits) (1.5% reading + 3 digits) AC Current Resistance (2.5% reading + 15digits) 2.0% reading or 2C, 4 F o o o NOTE: Accuracy is stated at 18 C to 28 C (65 F to 83 F) and less than 75% RH. 13 EX470-en-GB_v5.6 4/15 Function Frequency Range 5.000Hz 50.00Hz 500.0Hz 5.000kHz 50.00kHz 500.0kHz 5.000MHz 10.00MHz Resolution 0.001Hz 0.01Hz 0.1Hz 0.001kHz 0.01kHz 0.1kHz 0.001MHz 0.01MHz Accuracy (1.5% reading + 5 digits) (1.2% reading + 2 digits) (1.5% reading + 4 digits) Sensitivity: 0.8V rms min. @ 20% to 80% duty cycle and <100kHz; 5Vrms min @ 20% to 80% duty cycle and > 100kHz. 0.1% (1.2% reading + 2 digits) Pulse width: 100µs - 100ms, Frequency: 5Hz to 150kHz Note: Accuracy specifications consist of two elements: (% reading) – This is the accuracy of the measurement circuit. (+ digits) – This is the accuracy of the analog to digital converter. Duty Cycle 0.1 to 99.9% Diode Test Continuity Check Test current of 0.3mA maximum, open circuit voltage 1.5V DC typical Audible signal will sound if the resistance is less than 150 (approx.), test current <0.7mA Temperature Sensor Requires type K thermocouple IR Spectral response 6 to 16µm IR Emissivity 0.95 fixed IR distance ratio 8:1 Input Impedance >7.5MΩ (VDC & VAC) AC Response True rms ACV Bandwidth 50Hz to 1kHz Crest Factor <3:1 at full scale & <6:1 at half scale Display 4000 count backlit liquid crystal Overrange indication “OL” is displayed Auto Power Off 15 minutes (approximately) Polarity Automatic (no indication for positive); Minus (-) sign for negative Measurement Rate 2 times per second, nominal Low Battery Indication “ ” is displayed if battery voltage drops below operating voltage Battery One 9 volt (NEDA 1604) battery Fuses mA, µA ranges; 0.5A/250V fast blow A range; 20A/250V ceramic fast blow Operating Temperature 5ºC to 40ºC (41ºF to 104ºF) o o o o Storage Temperature -20 C to 60 C (-4 F to 140 F) Operating Humidity Max 80% up to 31ºC (87ºF) decreasing linearly to 50% at 40ºC (104ºF) Storage Humidity <80% Operating Altitude 2000 meters.(7000ft) maximum. Weight 342g (0.753lb) (includes holster). Size 187 x 81 x 50mm (7.36” x 3.2” x 2.0”) (includes holster) Safety For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (2001): EN61010-1 (2001) Overvoltage Category III 600V and Category II 1000V, Pollution Degree 2. Patent Notice U.S. Patent 7056012 14 EX470-en-GB_v5.6 4/15 Maintenance WARNING: To avoid electrical shock, disconnect the meter from any circuit, remove the test leads from the input terminals, and turn OFF the meter before opening the case. Do not operate the meter with an open case. This MultiMeter is designed to provide years of dependable service, if the following care instructions are performed: 1. KEEP THE METER DRY. If it gets wet, wipe it off. 2. USE AND STORE THE METER IN NORMAL TEMPERATURES. Temperature extremes can shorten the life of the electronic parts and distort or melt plastic parts. 3. HANDLE THE METER GENTLY AND CAREFULLY. Dropping it can damage the electronic parts or the case. 4. KEEP THE METER CLEAN. Wipe the case occasionally with a damp cloth. DO NOT use chemicals, cleaning solvents, or detergents. 5. USE ONLY FRESH BATTERIES OF THE RECOMMENDED SIZE AND TYPE. Remove old or weak batteries so they do not leak and damage the unit. 6. IF THE METER IS TO BE STORED FOR A LONG PERIOD OF TIME, the batteries should be removed to prevent damage to the unit. Battery Replacement 1. Remove the Phillips head screw that secures the rear battery door 2. Open the battery compartment 3. Replace the 9V battery 4. Secure the battery compartment Never dispose of used batteries or rechargeable batteries in household waste. As consumers, users are legally required to take used batteries to appropriate collection sites, the retail store where the batteries were purchased, or wherever batteries are sold. Disposal: Do not dispose of this instrument in household waste. The user is obligated to take end-oflife devices to a designated collection point for the disposal of electrical and electronic equipment. Other Battery Safety Reminders o Never dispose of batteries in a fire. Batteries may explode or leak. o Never mix battery types. Always install new batteries of the same type. WARNING: To avoid electric shock, do not operate the meter until the battery cover is in place and fastened securely. NOTE:: If your meter does not work properly, check the fuses and batteries to make sure that they are still good and that they are properly inserted. 15 EX470-en-GB_v5.6 4/15 REPLACING THE FUSES WARNING: To avoid electrical shock, disconnect the meter from any circuit, remove the test leads from the input terminals, and turn OFF the meter before opening the case. Do not operate the meter with an open case. 1. Disconnect the test leads from the meter. 2. Remove the protective rubber holster. 3. Remove the battery cover (two “B” screws) and the battery. 4. Remove the four “A” screws securing the rear cover. 5. Lift the center circuit board straight up from the connectors to gain access to the fuse holders. 6. Gently remove the old fuse and install the new fuse into the holder. 7. Always use a fuse of the proper size and value (0.5A/250V fast blow for the 400mA range, 20A/250V fast blow for the 20A range). 8. Align the center board with the connectors and gently press into place. 9. Replace and secure the rear cover, battery and battery cover. WARNING: To avoid electric shock, do not operate your meter until the fuse cover is in place and fastened securely. UL LISTED The UL mark does not indicate that this product has been evaluated for the accuracy of its readings. Copyright © 2013‐2015 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form ISO‐9001 Certified www.extech.com 16 EX470-en-GB_v5.6 4/15