TPC Series Low ESR TACmicrochip® FEATURES • • • • • Low ESR TACmicrochip® capacitor Smallest and low profile tantalum CV range: 1.0-100μF / 3-25V 4 case sizes available Power supply applications LEAD-FREE COMPATIBLE COMPONENT APPLICATIONS • Portable controller with elevated power requirements L CASE DIMENSIONS: millimeters (inches) Code POLARITY BAND NOT TO EXCEED CENTER LINE %H EIA EIA Code Metric 0805 Minimum L+0.20 (0.008) W+0.15 (0.008) H+0.15 (0.008) Termination Termination -0.00 (0.000) -0.00 (0.000) -0.00 (0.000) Spacing(S) Length (Lt) 2012-10 2.00 (0.079) 1.35 (0.053) +0.20 H S Lt K W MARKING 0402 1005-07 0.50 -0.00 1.00 (0.039) 1.00 (0.039) max 0.70 (0.028) min 0.15 (0.006) +0.20 0.50 -0.00 +0.008 0.40 (0.016) min 0.10 (0.004) (0.020 -0.000 ) (0.020 -0.000 ) +0.008 %L 0603 1608-10 1.60 (0.063) 0.85 (0.033) 0.85 (0.033) 0.55 (0.022) min 0.15 (0.006) R 0805 2012-15 2.00 (0.079) 1.35 (0.053) 1.35 (0.053) 0.70 (0.028) min 0.15 (0.006) H, K, L, R CASE Polarity Band (Anode+) HOW TO ORDER TPC R Type TACmicrochip® Case Size See table above 106 * 010 R 1800 Capacitance Code pF code: 1st two digits represent significant figures, 3rd digit represents multiplier (number of zeros to follow) Tolerance K=±10% M=±20% Rated DC Voltage 003=3Vdc 004=4Vdc 006=6.3Vdc 010=10Vdc 016=16Vdc 020=20Vdc 025=25Vdc Packaging R, P = 7" Standard Tin Termination Plastic Tape X, Q = 41⁄4" Standard Tin Termination Plastic Tape A, M = 7" Gold Termination Plastic Tape F, N = 41⁄4" Gold Termination Plastic Tape ESR in mΩ TECHNICAL SPECIFICATIONS Technical Data: Capacitance Range: Capacitance Tolerance: Leakage Current DCL: Rated Voltage (VR) Category Voltage (VC) Surge Voltage (VS) Surge Voltage (VS) Temperature Range: Reliability: Termination Finish: 102 ⱕ +85°C: ⱕ +125°C: ⱕ +85°C: ⱕ +125°C: All technical data relate to an ambient temperature of +25°C 1.0 μF to 100 μF ±10%; ±20% 0.01CV or 0.5μA whichever is the greater 3 4 6.3 10 16 20 25 2 2.7 4 7 10 13 17 3.9 5.2 8 13 20 26 32 2.6 3.2 5 8 12 16 20 -55°C to +125°C 1% per 1000 hours at 85°C, VR with 0.1Ω/V series impedance, 60% confidence level Nickel and Tin Plating (standard), Nickel and Gold Plating option available upon request 021616 TPC Series Low ESR TACmicrochip® CAPACITANCE AND RATED VOLTAGE RANGE (LETTER DENOTES CASE SIZE) Capacitance μF Code 1.0 105 1.5 155 2.2 225 3.3 335 4.7 475 6.8 685 10 106 15 22 33 47 68 100 156 226 336 476 686 107 3.0V 4.0V Voltage Rating DC (VR ) at 85°C 6.3V 10V L(5000) K(8000)/L(5000) K(8000) L(4000) R(1800) R(1500) L(5000)/R(1800) H(1500)/R(1500) R(1800) R(1500) 16V L(5000) L(5000) L(5000) L(5000) H(2500) L(4000),R(1800) R(1500) R(1500) R(1500) R(1800) 20V 25V R(3000) R(1500)* R(1800) R(1000) Codes shown are examples of ESR values offered on certain CV and case size. Other codes and ESR values available upon request. Available Ratings, (ESR ratings in mOhms in brackets) Engineering samples - please contact manufacturer *Code under development – subject to change Note: Voltage ratings are minimum values. AVX reserves the right to supply higher ratings in the same case size, to the same reliability standards 021616 103 TPC Series Low ESR TACmicrochip® RATINGS & PART NUMBER REFERENCE AVX Part No. Case Capacitance Size (μF) Rated Voltage (V) Rated Category Category Temperature Voltage Temperature (ºC) (V) (ºC) TPCK475*003#8000 TPCR336*003#1800 TPCR476*003#1500 K R R 4.7 33 47 3 3 3 85 85 85 2 2 2 TPCL226*004#5000 TPCR226*004#1800 TPCH336*004#1500 TPCR336*004#1500 TPCR107*004#1000 L R H R R 22 22 33 33 100 4 4 4 4 4 85 85 85 85 85 2.7 2.7 2.7 2.7 2.7 TPCK225*006#8000 TPCL225*006#5000 TPCL106*006#4000 TPCR156*006#1800 TPCR226*006#1500 TPCR476*006#1800 K L L R R R 2.2 2.2 10 15 22 47 6.3 6.3 6.3 6.3 6.3 6.3 85 85 85 85 85 85 4 4 4 4 4 4 TPCL105*010#5000 TPCL225*010#5000 TPCL335*010#5000 TPCL475*010#5000 TPCH106*010#2500 TPCL106*010#4000 TPCR106*010#1800 TPCR156*010#1500 TPCR226*010#1500 TPCR336*010#1500 L L L L H L R R R R 1.0 2.2 3.3 4.7 10 10 10 15 22 33 10 10 10 10 10 10 10 10 10 10 85 85 85 85 85 85 85 85 85 85 7 7 7 7 7 7 7 7 7 7 TPCL225*016#5000 TPCR106*016#1800 L R 2.2 10 16 16 85 85 10 10 TPCR475*020#1500 R 4.7 20 85 13 TPCR105*025#3000 R 1.0 25 85 17 3 Volt @ 85°C 125 125 125 4 Volt @ 85°C 125 125 125 125 125 6.3 Volt @ 85°C 125 125 125 125 125 125 10 Volt @ 85°C 125 125 125 125 125 125 125 125 125 125 16 Volt @ 85°C 125 125 20 Volt @ 85°C 125 25 Volt @ 85°C 125 DCL Max. (μA) DF Max. (%) ESR Max. @ 100kHz (mΩ) MSL 0.5 1.0 1.5 12 10 10 8000 1800 1500 0.9 0.9 1.3 1.3 4.0 6 8 14 10 30 0.5 0.5 0.6 0.9 1.4 3.0 100kHz RMS Current (A) Product Category 25ºC 85ºC 125ºC 1 1 1 0.043 0.158 0.173 0.039 0.142 0.156 0.017 0.063 0.069 3 2 3 5000 1800 1500 1500 1000 1 1 1 1 1 0.071 0.158 0.163 0.173 0.212 0.064 0.142 0.147 0.156 0.191 0.028 0.063 0.065 0.069 0.085 3 1 3 2 3 8 6 10 8 10 20 8000 5000 4000 1800 1500 1800 1 1 1 1 1 1 0.043 0.071 0.079 0.158 0.173 0.158 0.039 0.064 0.071 0.142 0.156 0.142 0.017 0.028 0.032 0.063 0.069 0.063 3 1 3 1 1 3 0.5 0.5 0.5 0.5 1.0 1.0 1.0 1.5 2.2 3.3 6 6 8 10 8 20 8 10 14 20 5000 5000 5000 5000 2500 4000 1800 1500 1500 1500 1 1 1 1 1 1 1 1 1 1 0.071 0.071 0.071 0.071 0.126 0.079 0.158 0.173 0.173 0.173 0.064 0.064 0.064 0.064 0.113 0.071 0.142 0.156 0.156 0.156 0.028 0.028 0.028 0.028 0.050 0.032 0.063 0.069 0.069 0.069 1 1 2 2 2 3 1 1 2 3 0.5 1.6 10 10 5000 1800 1 1 0.071 0.158 0.064 0.142 0.028 0.063 1 2 0.9 8 1500 1 0.173 0.156 0.069 1 0.5 8 3000 1 0.122 0.110 0.049 1 Moisture Sensitivity Level (MSL) is defined according to J-STD-020. All technical data relates to an ambient temperature of +25°C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts. DCL is measured at rated voltage after 5 minutes. For typical weight and composition see page 223. NOTE: AVX reserves the right to supply a higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards. 104 021616 TPC Series Low ESR TACmicrochip® QUALIFICATION TABLE – CATEGORY 1 TEST Endurance Humidity Temperature Stability Surge Voltage TPC series (Temperature range -55ºC to +125ºC) Characteristics Visual examination no visible damage Determine after application of rated voltage for 2000 +48/-0 hours at 85±2ºC and then leaving 1-2 hours DCL 1.25 x initial limit at room temperature. Also determine of 125ºC temΔC/C within ±10% of initial value perature, category voltage for 2000 +48/-0 hours and then leaving 1-2 hours at room temperature. DF 1.5 x initial limit Power supply impedance to be ≤0.1Ω/V. ESR 1.5 x initial limit Visual examination no visible damage Determine after storage without applied voltage at DCL initial limit 40±2ºC and 90-95% relative humidity for 1344 ΔC/C within ±5% of initial value +48/-0 hours and then recovery 1-2 hours at room temperature DF 1.2 x initial limit ESR 1.2 x initial limit Condition Step 1 2 3 4 5 6 Temperature°C +20±2 -55+0/-3 +20±2 +85+3/-0 +125+3/-0 +20±2 Duration(min) 15 15 15 15 15 15 Test temperature: 85ºC+3/0ºC Test voltage: 1.3 x rated voltage Series protection resistance 1000±100Ω Discharge resistance: 1000Ω Number of cycles: 1000x Cycle duration: 6 min; 30 sec charge, 5 min 30 sec discharge DCL ΔC/C DF ESR Visual examination DCL ΔC/C DF ESR +20ºC -55ºC +20ºC +85ºC +125ºC +20ºC IL* n/a IL* 10 x IL* 12.5 x IL* IL* n/a +0/-10% ±5% +10/-0% +15/-0% ±5% IL* 1.5 x IL* IL* 1.5 x IL* 2 x IL* IL* IL* 1.25 x IL* IL* 1.25 x IL* 2 x IL* IL* no visible damage initial limit within ±10% of initial value initial limit initial limit *Initial Limit QUALIFICATION TABLE – CATEGORY 2 TEST Endurance Humidity Temperature Stability Surge Voltage TPC series (Temperature range -55ºC to +125ºC) Characteristics Visual examination no visible damage Determine after application of rated voltage for 2000 +48/-0 hours at 85±2ºC and then leaving 1-2 hours DCL 1.25 x initial limit at room temperature. Also determine of 125ºC temΔC/C within ±15% of initial value perature, category voltage for 2000 +48/-0 hours and then leaving 1-2 hours at room temperature. DF 1.5 x initial limit Power supply impedance to be ≤0.1Ω/V. ESR 1.5 x initial limit Visual examination no visible damage Determine after storage without applied voltage at DCL initial limit 40±2ºC and 90-95% relative humidity for 1344 ΔC/C within ±10% of initial value +48/-0 hours and then recovery 1-2 hours at room temperature DF 1.2 x initial limit ESR 1.2 x initial limit Condition Step 1 2 3 4 5 6 Temperature°C +20±2 -55+0/-3 +20±2 +85+3/-0 +125+3/-0 +20±2 Duration(min) 15 15 15 15 15 15 Test temperature: 85ºC+3/0ºC Test voltage: 1.3 x rated voltage Series protection resistance 1000±100Ω Discharge resistance: 1000Ω Number of cycles: 1000x Cycle duration: 6 min; 30 sec charge, 5 min 30 sec discharge +20ºC -55ºC +20ºC +85ºC +125ºC +20ºC DCL ΔC/C DF IL* n/a IL* 10 x IL* 12.5 x IL* IL* n/a +0/-15% ±5% +15/-0% +20/-0% ±5% IL* 1.5 x IL* IL* 1.5 x IL* 2 x IL* IL* ESR IL* 1.25 x IL* IL* 1.25 x IL* 2 x IL* IL* Visual examination DCL ΔC/C DF ESR no visible damage 1.5 x initial limit within ±15% of initial value 1.5 x initial limit 1.5 x initial limit *Initial Limit 021616 105 TPC Series Low ESR TACmicrochip® QUALIFICATION TABLE – CATEGORY 3 TEST Endurance Humidity Temperature Stability Surge Voltage TPC series (Temperature range -55ºC to +125ºC) Characteristics Visual examination no visible damage Determine after application of rated voltage for 2000 +48/-0 hours at 85±2ºC and then leaving 1-2 hours DCL 1.25 x initial limit at room temperature. Also determine of 125ºC temΔC/C within ±30% of initial value perature, category voltage for 2000 +48/-0 hours and then leaving 1-2 hours at room temperature. DF 1.5 x initial limit Power supply impedance to be ≤0.1Ω/V. ESR 1.5 x initial limit Visual examination no visible damage Determine after storage without applied voltage at DCL 2 x initial limit 40±2ºC and 90-95% relative humidity for 1344 ΔC/C within ±30% of initial value +48/-0 hours and then recovery 1-2 hours at room temperature DF 1.5 x initial limit ESR 1.25 x initial limit Condition Step 1 2 3 4 5 6 Temperature°C +20±2 -55+0/-3 +20±2 +85+3/-0 +125+3/-0 +20±2 Duration(min) 15 15 15 15 15 15 Test temperature: 85ºC+3/0ºC Test voltage: 1.3 x rated voltage Series protection resistance 1000±100Ω Discharge resistance: 1000Ω Number of cycles: 1000x Cycle duration: 6 min; 30 sec charge, 5 min 30 sec discharge DCL ΔC/C DF ESR Visual examination DCL ΔC/C DF ESR +20ºC -55ºC +20ºC +85ºC +125ºC +20ºC IL* n/a IL* 10 x IL* 12.5 x IL* IL* n/a +0/-25% ±5% +20/-0% +25/-0% ±20% IL* 1.5 x IL* IL* 1.5 x IL* 2 x IL* 1.5 x IL* IL* 1.25 x IL* IL* 1.25 x IL* 2 x IL* 1.5 x IL* no visible damage 2 x initial limit within ±30% of initial value 2 x initial limit 2 x initial limit *Initial Limit 106 021616