TPC Series Datasheet

TPC Series
Low ESR TACmicrochip®
FEATURES
•
•
•
•
•
Low ESR TACmicrochip® capacitor
Smallest and low profile tantalum
CV range: 1.0-100μF / 3-25V
4 case sizes available
Power supply applications
LEAD-FREE COMPATIBLE
COMPONENT
APPLICATIONS
• Portable controller with elevated power requirements
L
CASE DIMENSIONS: millimeters (inches)
Code
POLARITY BAND NOT TO
EXCEED CENTER LINE
%H
EIA
EIA
Code Metric
0805
Minimum
L+0.20 (0.008) W+0.15 (0.008) H+0.15 (0.008) Termination
Termination
-0.00 (0.000)
-0.00 (0.000) -0.00 (0.000) Spacing(S)
Length (Lt)
2012-10
2.00 (0.079)
1.35 (0.053)
+0.20
H
S
Lt
K
W
MARKING
0402
1005-07
0.50 -0.00
1.00 (0.039)
1.00 (0.039) max 0.70 (0.028) min
0.15 (0.006)
+0.20
0.50 -0.00
+0.008
0.40 (0.016) min
0.10 (0.004)
(0.020 -0.000 )
(0.020 -0.000 )
+0.008
%L
0603
1608-10
1.60 (0.063)
0.85 (0.033)
0.85 (0.033)
0.55 (0.022) min
0.15 (0.006)
R
0805
2012-15
2.00 (0.079)
1.35 (0.053)
1.35 (0.053)
0.70 (0.028) min
0.15 (0.006)
H, K, L, R CASE
Polarity
Band
(Anode+)
HOW TO ORDER
TPC
R
Type
TACmicrochip®
Case Size
See table
above
106
*
010
R
1800
Capacitance Code
pF code: 1st two digits
represent significant figures,
3rd digit represents multiplier
(number of zeros to follow)
Tolerance
K=±10%
M=±20%
Rated DC
Voltage
003=3Vdc
004=4Vdc
006=6.3Vdc
010=10Vdc
016=16Vdc
020=20Vdc
025=25Vdc
Packaging
R, P = 7" Standard Tin
Termination Plastic Tape
X, Q = 41⁄4" Standard Tin
Termination Plastic Tape
A, M = 7" Gold Termination
Plastic Tape
F, N = 41⁄4" Gold Termination
Plastic Tape
ESR in mΩ
TECHNICAL SPECIFICATIONS
Technical Data:
Capacitance Range:
Capacitance Tolerance:
Leakage Current DCL:
Rated Voltage (VR)
Category Voltage (VC)
Surge Voltage (VS)
Surge Voltage (VS)
Temperature Range:
Reliability:
Termination Finish:
102
ⱕ +85°C:
ⱕ +125°C:
ⱕ +85°C:
ⱕ +125°C:
All technical data relate to an ambient temperature of +25°C
1.0 μF to 100 μF
±10%; ±20%
0.01CV or 0.5μA whichever is the greater
3
4
6.3
10
16
20
25
2
2.7
4
7
10
13
17
3.9
5.2
8
13
20
26
32
2.6
3.2
5
8
12
16
20
-55°C to +125°C
1% per 1000 hours at 85°C, VR with 0.1Ω/V series impedance,
60% confidence level
Nickel and Tin Plating (standard),
Nickel and Gold Plating option available upon request
021616
TPC Series
Low ESR TACmicrochip®
CAPACITANCE AND RATED VOLTAGE RANGE
(LETTER DENOTES CASE SIZE)
Capacitance
μF
Code
1.0
105
1.5
155
2.2
225
3.3
335
4.7
475
6.8
685
10
106
15
22
33
47
68
100
156
226
336
476
686
107
3.0V
4.0V
Voltage Rating DC (VR ) at 85°C
6.3V
10V
L(5000)
K(8000)/L(5000)
K(8000)
L(4000)
R(1800)
R(1500)
L(5000)/R(1800)
H(1500)/R(1500)
R(1800)
R(1500)
16V
L(5000)
L(5000)
L(5000)
L(5000)
H(2500)
L(4000),R(1800)
R(1500)
R(1500)
R(1500)
R(1800)
20V
25V
R(3000)
R(1500)*
R(1800)
R(1000)
Codes shown are examples of ESR values offered on certain CV and case size.
Other codes and ESR values available upon request.
Available Ratings, (ESR ratings in mOhms in brackets)
Engineering samples - please contact manufacturer
*Code under development – subject to change
Note: Voltage ratings are minimum values. AVX reserves the right to supply
higher ratings in the same case size, to the same reliability standards
021616
103
TPC Series
Low ESR TACmicrochip®
RATINGS & PART NUMBER REFERENCE
AVX
Part No.
Case Capacitance
Size
(μF)
Rated
Voltage
(V)
Rated
Category Category
Temperature Voltage Temperature
(ºC)
(V)
(ºC)
TPCK475*003#8000
TPCR336*003#1800
TPCR476*003#1500
K
R
R
4.7
33
47
3
3
3
85
85
85
2
2
2
TPCL226*004#5000
TPCR226*004#1800
TPCH336*004#1500
TPCR336*004#1500
TPCR107*004#1000
L
R
H
R
R
22
22
33
33
100
4
4
4
4
4
85
85
85
85
85
2.7
2.7
2.7
2.7
2.7
TPCK225*006#8000
TPCL225*006#5000
TPCL106*006#4000
TPCR156*006#1800
TPCR226*006#1500
TPCR476*006#1800
K
L
L
R
R
R
2.2
2.2
10
15
22
47
6.3
6.3
6.3
6.3
6.3
6.3
85
85
85
85
85
85
4
4
4
4
4
4
TPCL105*010#5000
TPCL225*010#5000
TPCL335*010#5000
TPCL475*010#5000
TPCH106*010#2500
TPCL106*010#4000
TPCR106*010#1800
TPCR156*010#1500
TPCR226*010#1500
TPCR336*010#1500
L
L
L
L
H
L
R
R
R
R
1.0
2.2
3.3
4.7
10
10
10
15
22
33
10
10
10
10
10
10
10
10
10
10
85
85
85
85
85
85
85
85
85
85
7
7
7
7
7
7
7
7
7
7
TPCL225*016#5000
TPCR106*016#1800
L
R
2.2
10
16
16
85
85
10
10
TPCR475*020#1500
R
4.7
20
85
13
TPCR105*025#3000
R
1.0
25
85
17
3 Volt @ 85°C
125
125
125
4 Volt @ 85°C
125
125
125
125
125
6.3 Volt @ 85°C
125
125
125
125
125
125
10 Volt @ 85°C
125
125
125
125
125
125
125
125
125
125
16 Volt @ 85°C
125
125
20 Volt @ 85°C
125
25 Volt @ 85°C
125
DCL
Max.
(μA)
DF
Max.
(%)
ESR
Max.
@ 100kHz
(mΩ)
MSL
0.5
1.0
1.5
12
10
10
8000
1800
1500
0.9
0.9
1.3
1.3
4.0
6
8
14
10
30
0.5
0.5
0.6
0.9
1.4
3.0
100kHz RMS Current (A)
Product
Category
25ºC
85ºC
125ºC
1
1
1
0.043
0.158
0.173
0.039
0.142
0.156
0.017
0.063
0.069
3
2
3
5000
1800
1500
1500
1000
1
1
1
1
1
0.071
0.158
0.163
0.173
0.212
0.064
0.142
0.147
0.156
0.191
0.028
0.063
0.065
0.069
0.085
3
1
3
2
3
8
6
10
8
10
20
8000
5000
4000
1800
1500
1800
1
1
1
1
1
1
0.043
0.071
0.079
0.158
0.173
0.158
0.039
0.064
0.071
0.142
0.156
0.142
0.017
0.028
0.032
0.063
0.069
0.063
3
1
3
1
1
3
0.5
0.5
0.5
0.5
1.0
1.0
1.0
1.5
2.2
3.3
6
6
8
10
8
20
8
10
14
20
5000
5000
5000
5000
2500
4000
1800
1500
1500
1500
1
1
1
1
1
1
1
1
1
1
0.071
0.071
0.071
0.071
0.126
0.079
0.158
0.173
0.173
0.173
0.064
0.064
0.064
0.064
0.113
0.071
0.142
0.156
0.156
0.156
0.028
0.028
0.028
0.028
0.050
0.032
0.063
0.069
0.069
0.069
1
1
2
2
2
3
1
1
2
3
0.5
1.6
10
10
5000
1800
1
1
0.071
0.158
0.064
0.142
0.028
0.063
1
2
0.9
8
1500
1
0.173
0.156
0.069
1
0.5
8
3000
1
0.122
0.110
0.049
1
Moisture Sensitivity Level (MSL) is defined according to J-STD-020.
All technical data relates to an ambient temperature of +25°C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts.
DCL is measured at rated voltage after 5 minutes.
For typical weight and composition see page 223.
NOTE: AVX reserves the right to supply a higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards.
104
021616
TPC Series
Low ESR TACmicrochip®
QUALIFICATION TABLE – CATEGORY 1
TEST
Endurance
Humidity
Temperature
Stability
Surge
Voltage
TPC series (Temperature range -55ºC to +125ºC)
Characteristics
Visual
examination
no
visible damage
Determine after application of rated voltage for 2000
+48/-0 hours at 85±2ºC and then leaving 1-2 hours
DCL
1.25 x initial limit
at room temperature. Also determine of 125ºC temΔC/C
within ±10% of initial value
perature, category voltage for 2000 +48/-0 hours
and then leaving 1-2 hours at room temperature.
DF
1.5 x initial limit
Power supply impedance to be ≤0.1Ω/V.
ESR
1.5 x initial limit
Visual examination
no visible damage
Determine after storage without applied voltage at
DCL
initial limit
40±2ºC and 90-95% relative humidity for 1344
ΔC/C
within ±5% of initial value
+48/-0 hours and then recovery 1-2 hours at
room temperature
DF
1.2 x initial limit
ESR
1.2 x initial limit
Condition
Step
1
2
3
4
5
6
Temperature°C
+20±2
-55+0/-3
+20±2
+85+3/-0
+125+3/-0
+20±2
Duration(min)
15
15
15
15
15
15
Test temperature: 85ºC+3/0ºC
Test voltage: 1.3 x rated voltage
Series protection resistance 1000±100Ω
Discharge resistance: 1000Ω
Number of cycles: 1000x
Cycle duration: 6 min; 30 sec charge,
5 min 30 sec discharge
DCL
ΔC/C
DF
ESR
Visual examination
DCL
ΔC/C
DF
ESR
+20ºC
-55ºC
+20ºC
+85ºC
+125ºC +20ºC
IL*
n/a
IL*
10 x IL*
12.5 x IL*
IL*
n/a
+0/-10%
±5%
+10/-0%
+15/-0%
±5%
IL*
1.5 x IL*
IL*
1.5 x IL*
2 x IL*
IL*
IL*
1.25 x IL*
IL*
1.25 x IL*
2 x IL*
IL*
no visible damage
initial limit
within ±10% of initial value
initial limit
initial limit
*Initial Limit
QUALIFICATION TABLE – CATEGORY 2
TEST
Endurance
Humidity
Temperature
Stability
Surge
Voltage
TPC series (Temperature range -55ºC to +125ºC)
Characteristics
Visual
examination
no
visible damage
Determine after application of rated voltage for 2000
+48/-0 hours at 85±2ºC and then leaving 1-2 hours
DCL
1.25 x initial limit
at room temperature. Also determine of 125ºC temΔC/C
within ±15% of initial value
perature, category voltage for 2000 +48/-0 hours
and then leaving 1-2 hours at room temperature.
DF
1.5 x initial limit
Power supply impedance to be ≤0.1Ω/V.
ESR
1.5 x initial limit
Visual examination
no visible damage
Determine after storage without applied voltage at
DCL
initial limit
40±2ºC and 90-95% relative humidity for 1344
ΔC/C
within ±10% of initial value
+48/-0 hours and then recovery 1-2 hours at
room temperature
DF
1.2 x initial limit
ESR
1.2 x initial limit
Condition
Step
1
2
3
4
5
6
Temperature°C
+20±2
-55+0/-3
+20±2
+85+3/-0
+125+3/-0
+20±2
Duration(min)
15
15
15
15
15
15
Test temperature: 85ºC+3/0ºC
Test voltage: 1.3 x rated voltage
Series protection resistance 1000±100Ω
Discharge resistance: 1000Ω
Number of cycles: 1000x
Cycle duration: 6 min; 30 sec charge,
5 min 30 sec discharge
+20ºC
-55ºC
+20ºC
+85ºC
+125ºC +20ºC
DCL
ΔC/C
DF
IL*
n/a
IL*
10 x IL*
12.5 x IL*
IL*
n/a
+0/-15%
±5%
+15/-0%
+20/-0%
±5%
IL*
1.5 x IL*
IL*
1.5 x IL*
2 x IL*
IL*
ESR
IL*
1.25 x IL*
IL*
1.25 x IL*
2 x IL*
IL*
Visual examination
DCL
ΔC/C
DF
ESR
no visible damage
1.5 x initial limit
within ±15% of initial value
1.5 x initial limit
1.5 x initial limit
*Initial Limit
021616
105
TPC Series
Low ESR TACmicrochip®
QUALIFICATION TABLE – CATEGORY 3
TEST
Endurance
Humidity
Temperature
Stability
Surge
Voltage
TPC series (Temperature range -55ºC to +125ºC)
Characteristics
Visual
examination
no
visible damage
Determine after application of rated voltage for 2000
+48/-0 hours at 85±2ºC and then leaving 1-2 hours
DCL
1.25 x initial limit
at room temperature. Also determine of 125ºC temΔC/C
within ±30% of initial value
perature, category voltage for 2000 +48/-0 hours
and then leaving 1-2 hours at room temperature.
DF
1.5 x initial limit
Power supply impedance to be ≤0.1Ω/V.
ESR
1.5 x initial limit
Visual examination
no visible damage
Determine after storage without applied voltage at
DCL
2 x initial limit
40±2ºC and 90-95% relative humidity for 1344
ΔC/C
within ±30% of initial value
+48/-0 hours and then recovery 1-2 hours at
room temperature
DF
1.5 x initial limit
ESR
1.25 x initial limit
Condition
Step
1
2
3
4
5
6
Temperature°C
+20±2
-55+0/-3
+20±2
+85+3/-0
+125+3/-0
+20±2
Duration(min)
15
15
15
15
15
15
Test temperature: 85ºC+3/0ºC
Test voltage: 1.3 x rated voltage
Series protection resistance 1000±100Ω
Discharge resistance: 1000Ω
Number of cycles: 1000x
Cycle duration: 6 min; 30 sec charge,
5 min 30 sec discharge
DCL
ΔC/C
DF
ESR
Visual examination
DCL
ΔC/C
DF
ESR
+20ºC
-55ºC
+20ºC
+85ºC
+125ºC +20ºC
IL*
n/a
IL*
10 x IL*
12.5 x IL*
IL*
n/a
+0/-25%
±5%
+20/-0%
+25/-0%
±20%
IL*
1.5 x IL*
IL*
1.5 x IL*
2 x IL*
1.5 x IL*
IL*
1.25 x IL*
IL*
1.25 x IL*
2 x IL*
1.5 x IL*
no visible damage
2 x initial limit
within ±30% of initial value
2 x initial limit
2 x initial limit
*Initial Limit
106