ON/OFF HIGHWAY Switches and Controls CATALOG • Rocker • Toggle • Pushbutton • Rotary CIRCUIT PROTECTION • Hydraulic-Magnetic • Thermal • GFCI / ELCI CUSTOM SOLUTIONS • PDU’s • Keypads • Control Modules STRATEGIC MARKETS SERVED: On/Off Highway Marine Telecom/Datacom Military Renewable Energy GLOBAL LOCATIONS: ISO9001:2008 ISO/TS16949:2009 ISO9001:2008 ISO/TS16949:2009 ISO9001:2008 ISO/TS16949:2009 ISO14001:2004 ISO9001:2008 ISO/TS16949:2009 ISO14001:2004 ISO9001:2008 ISO/TS16949:2009 ISO14001:2004 ISO9001:2008 ISO/TS16949:2009 COMPETITIVE ADVANTAGES + Vertical Integration Reliable & On-Time Delivery Excellent Customer Service MULTIPLEXED POWER SYSTEMS • HMI Devices & I/O Modules • Programmable Displays • Data Communication Interfaces • Electrical Systems Monitoring ..................................................................................................................... SWITCHES & CONTROLS ................... Since its founding, Carling Technologies has continually forged a tradition of leadership in quality and product innovation. ................... 1920 There are few products that Carling Technologies hasn’t turned “ON” and fewer industries that haven’t turned to Carling for solutions. With ISO and TS registered manufacturing facilities and technical sales offices worldwide, Carling ranks among the world’s largest manufacturers of circuit breakers, switches, power distribution units, digital switching systems and electronic controls. ................... FOUNDED IN Innovative & Eco-Friendly Products OTHER SERVED INDUSTRIES: Medical Industrial Control Audio / Visual Commercial Food HVAC Floor Care Generators Small Appliances Security Systems Test & Measurment WORLDWIDE NUMBERS: 2200+ 150+ EMPLOYEES ENGINEERS 70 + 50+ DISTRIBUTORS REP FIRMS On/Off Highway Table of Contents With years of design and manufacturing experience, Carling Technologies is the market leader in transportation application switches & control modules providing solutions to most all major OEMs. Carling’s switches are widely used and the most recognizable switch brand in the industry with unmatched quality and aesthetics. By drawing upon over 90 years of design experience, Carling Technologies is also able to provide custom product solutions such as operator control modules and custom electronic controls, that are sure to meet the most stringent design requirements. Switches & Controls V-Series - Sealed Rocker Switch...................................... 4 V-Series - Rotary Switch................................................... 23 V-Charger - Sealed Control .............................................. 30 VP-Series - Illuminated Indicator..................................... 37 W-Series - Submersible Switch....................................... 40 L-Series - Sealed Rocker Switch.................................... 45 LP-Series - Illuminated Indicator..................................... 55 Standard Legend Imprinting............................................. 83 S-Series - Rocker Switch.................................................. 58 N-Series - Addressable Rocker....................................... 62 LD-Series - Electronic Dimmer Control.......................... 67 LMR-Series - Mirror Rotate Control................................ 70 LW-Series - Wiper/Washer Control................................. 72 Within This Catalog, you will find comprehensive product information for each product series including applications, specifications and ordering schemes. Thermal CMB-Series......................................................................... 75 CLB-Series.......................................................................... 77 CMBA/CLBA....................................................................... 79 Available Online are tools such as part Custom Electronic Controls ............................................ 81 Operator Control Modules................................................ 82 Switches and Controls configurator, product selectors and stock checks. Please visit www.carlingtech.com for the latest information on all our products. page Product Selector Guide.......................................................2 Application Solution Engineers are readily available to assist you in selecting the appropriate product for your application. For further assistance, please email us at [email protected] Custom Design Solutions are available for OEMs that require specific product design and performance. Other Circuit Protection Products such as thermal protection and ground fault circuit protection are also available. Please refer to www.carlingtech.com for a complete list of product offering. www.carlingtech.com 1 Product Selector Guide SEALED ROCKERS NEW V-Series NEW V-Series Rotary Poles 1, 2 1, 2 Ratings up to 15A 24VDC 15A 125VAC 10A 250VAC Actuator rocker, paddle, locking rocker Mounting Hole Specifications .830” x 1.450” [21.08mm x 36.83mm] snap-in mount Termination V-Charger W-Series L-Series 1 1, 2 1, 2 up to 15A 24VDC 20A 12VDC 12V/24V DC up to 10A 24VDC up to 15A 125VAC 10A 250VAC 20A 18VDC ergonomic knob sealed spring-loaded access doors bezel-less rocker, paddle & locking rocker IP67, rocker, paddle, locking rocker .830” x 1.450” [21.08mm x 36.83mm] snap-in mount .830” x 1.450” [21.08mm x 36.83mm] snap-in mount .830” x 1.450” [21.08mm x 36.83mm] snap-in mount .867” x 1.734” [22mm x 44mm] snap-in mount .250 tabs solder lug wire leads solder lugs .250 tabs wire leads .250 tabs .110 tabs .187 tab .250 tabs Sealing IP66 above panel IP67 above panel IP64 above panel IP68 above and below panel, fully submersible IP67 above panel Illumination incandescent, LED, neon incandescent, LED LED LED incandescent, LED Approvals UL, CSA, VDE pending n/a n/a n/a ROCKER CONTROL S-Series N-Series L-SERIES CONTROLS LD Dimmer LMR Mirror LW Wiper Poles 1, 2 1 multi-function multi-function multi-function Ratings up to 10A 28VDC .4VA 28VDC up to 10A 12VDC 5A 24VDC up to 1A 14VDC .5A 28VDC up to 8A 14VDC 4A 28VDC Actuator bezel-less rocker rocker, paddle rocker, paddle joystick rocker, paddle Mounting Hole Specifications .787” x 1.575” snap-in, keyed .867” x 1.734” [22mm x 44mm] snap-in mount .867” x 1.734” [22mm x 44mm] snap-in mount .867” x 1.734” [22mm x 44mm] snap-in mount .867” x 1.734” [22mm x 44mm] snap-in mount Termination .110 Tabs .187 tabs .250 tabs wire leads with connector .187 tabs Sealing n/a IP67 above panel IP67 above panel Water Resistant n/a Illumination LED LED LED n/a LED Approvals n/a n/a n/a n/a n/a *Options and approvals shown may apply to specific construction combinations only, consult factory for clarification. Manufacturer reserves the right to change product specifications without prior notice. 2 www.carlingtech.com Product Selector Guide THERMAL CIRCUIT PROTECTION CMB-Series CLB-Series CLBA/CMBA-Series Number of Poles 1 1 1 Actuator pushbutton pushbutton n/a Leakage Current Trip Level n/a n/a n/a Leakage Current Trip Time n/a n/a n/a Max Current & Voltage Ratings 3 to 20A, 125-250VAC, 32VDC 3 to 60A, 125-250VAC, 32VDC 3 to 40A, 125-250VAC, 32VDC Max Interrupting Capacity 2500A@32 VDC 2500A@32 VDC 2500A@32 VDC Available Circuits series trip manual reset series trip manual reset series trip auto reset Termination .250 tab .250 tab with 90° bend screw terminal screw term with 90º bend .250 tab .250 tab with 90° bend screw terminal screw term with 90º bend .250” tab, .250” tab with 90° bend Mounting Method threaded bushing, front panel snap-in threaded bushing, front panel snap-in plug-in Approvals UL, CUL, CSA, TUV, CE, UL 1500 / ISO 8846 for ignition protection / marine UL, CUL, CSA, TUV, CE, UL 1500 / ISO 8846 for ignition protection / marine UL, CUL, TUV, UL 1500 / ISO 8846 for ignition protection / marine CUSTOM ELECTRONIC CONTROLS & POWER MANAGEMENT MODULES TOTAL VEHICLE CONTROL Cruise Control Light Control Module HVAC Motor Controller Horn Control Solid State Power Control CUSTOM OPERATOR CONTROL MODULES & DISPLAYS TOTAL VEHICLE CONTROL Keypads Multiplexed V-Series Rocker Modules Control Interface Multi-function Displays *Options and approvals shown may apply to specific construction combinations only, consult factory for clarification. www.carlingtech.com 3 V-Series Contura Sealed Rocker Switches - Introduction V-Series V-Series CONTURA SWITCHES Carling Technologies’ sealed V-Series Contura switches are well known for their cutting edge design, high quality, maximum performance and unmatched reliability. These switches are a staple in the marine and transportation industries and have passed a range of environmental, corrosion, temperature, vibration, shock and sealing tests including MIL Std 202F, MIL Std 810C, UL 1500, ISO 8846, IEC 60529 and BS 5490 among others, making them one of the most rugged and reliable switches ever manufactured. Resources: Download 3D CAD Files IGS STP Watch Product Video Product Highlights: Certified to IP66 with dual seals around lamps and rocker stem. Silver plated butt contact mechanism provides reliability up to and beyond 100K electrical cycles Greaseless construction withstands temperature extremes down to -40˚C The switch accommodates up to 10 terminals and endless illumination and circuit options. The switch connector allows the user to preload FQC terminals for ease of assembly. Numerous choices of removable rockers allow for style change without having to retest or re-qualify the switch base. 4 www.carlingtech.com V-Series Contura Sealed Rocker Switches - Design Features V-Series Switch DESIGN FEATURES INTERCHANGEABLE ACTUATORS Panel redesign is a snap with our wide range of rocker styles. Achieve maximum design variety with minimum inventory. Simply swap rockers to create an entirely new look for your panel. OPTIONAL PANEL SEAL Prevents water/dust ingress behind panel. www.carlingtech.com DUAL SEAL PROTECTION Seals out water, dust, debris, and enables switch certification to IP66 for front panel components. MULTIPLE LIGHTING OPTIONS In addition to Incandescent lamps, our LED illumination is offered in a wide array of light intensities, colors, as well as dual level, tri-color, and flashing options. CLEAN CONNECTIONS Options for both eight and ten terminal base styles with AMP & Packard compatible connectors affords myriad circuit options while providing ease of assembly. BRASS ROLLER PIN Robust mechanism eliminates the need for lubricants. Enables switch to withstand -40°C to +85°C temperatures. SILVER PLATED BUTT CONTACT MECHANISM Providing 50k to 100k electrical cycles and a variety of different electrical ratings. 5 V-Series Contura Sealed Rocker Switches - Actuator Options & Accessories Contura II & III Contura X Contura IV Contura XI Contura V Contura XII Contura VI (WAVE) Contura XIV Contura VII Illuminated Indicators & Accessories The Contura II & III actuators are constructed of thermoplastic polycarbonate and are offered with a hard nylon overlay or a “soft-touch” elastomer overlay. These models incorporate aesthetic designs on the top and bottom of the rocker featuring two rows of raised “bumps” on the Contura II and three “indented” lines on the Contura III. The Contura IV’s “Shape to create a Shape” actuator works with the curves, contours & advanced styling of the latest panel designs, flowing with these advanced curves & radii. This actuator style fits on the Contura flush bracket/bezel. The symmetrically curved Contura V actuator provides the perfect complement to the Contura IV’s “Shape to create a Shape” design concept. With its flush style mounting bracket, Contura V can be mounted in between two Contura IV’s, by itself, or in groups. The Contura VI WAVE sealed rocker switches, when used in a row, create an uniquely appealing “wave” design on your panel. A variety of colors and finishes are available for both rocker and wave insert. Contura VI features bar and oval lenses. Contura VII featuring gently curved corners and edges assuring compatibility with most any panel design. Intuitive feel is maximized by the use of 2 embossed circular pads located at opposite ends of the rocker. Any combination of Bar or Oval style lenses can be located in the pads providing a truly unique look, exclusive to Contura VII. 6 The raised bracket/bezel on the Contura X helps prevent inadvertent actuation of the rocker, as well as preventing debris from being trapped under the actuator. This curved rocker style is available with a variety of lenses and legends. The raised bracket/bezel on the Contura XI helps prevent inadvertent actuation of the rocker, as well as preventing debris from being trapped under the actuator. This convex style rocker is available with a wide variety of lenses and legends. The Contura XII version features a paddle style actuator with the raised bracket/bezel of Contura X and XI. The contoured handle design provides intuitive recognition and ease of operation and is available with all Contura X and XI lens and legend offerings. The Contura XIV represents a sleek new crossover rocker design which should appeal to Trucks, Buses and Heavy Vehicles as well as the Marine Industry. Intuitive feel is provided by recessed ridges along with a Center Groove which effectively defines the boundary between top and bottom switch functions. Alert operator of systems functions or malfunctions, are offered with removable/replaceable lamps in Contura II, II, V or X styles. Accessories include connectors, mounting panels, hole plugs, panel seals, and actuator removal tools. Refer to accessories page for full details www.carlingtech.com V–Series Contura Sealed Rocker Switches - General Specifications Electrical Contact Rating .4VA @ 24VDC (MAX) resistive 15 amps, 125VAC 10 amps, 250VAC 1/2 HP 125-250VAC 20 amps, 4-14VDC 15 amps, 15-28VDC 10A, 14VT 6A, 125VAC L Dielectric Strength 1500 Volts RMS Insulation Resistance 50 Megohms Initial Contact Resistance 10 milliohms max. @ 4VDC Life 50,000 - 100,000 cycles circuit dependent Contacts Silver alloy, silver tin-oxide, fine silver Terminals Brass or copper/silver plate 1/4” (6.3mm) Quick Connect terminations standard. Solder lug, Wire Lead Mechanical Endurance 150,000 cycles minimum circuit dependent Physical Lighted Incandescent - rated 10,000 hours Neon - rated 25,000 hours LED - rated 100,000 hours 1/2 life (LED is internally ballasted for voltages to 24VDC) Seals Internal Optional external gasket panel seal Base Polyester blend rated to 125°C with a UL flammability rating of 94V0. Contura II,III,IV,V, Hard Surface: Basic actuator VI, VII Actuator structure molded of thermoplastic polycarbonate with a hard Nylon 66 thermoplastic surface overlay. Soft Surface: Basic actuator structure molded of thermoplastic polycarbonate with an elastomer overlay. Contura X,XI,XII Actuator,VP Nylon 66 Reinforced rated to 105°C Lens Polycarbonate rated at 100°C Contura XIV Polycarbonate lens/sub-rocker with ABS shell Actuator Travel (Angular Displacement) 2 position 3 positions 18° 9° from center Mounting Specifications Agency Certifications Environmental Sealing Sealed version: IP66, this rating applies to front panel components of the actual switch only, and signifies complete protection against dust as well as powerful jets of water. Corrosion Mixed Flowing Gas (MFG) Class III 3 year accelerated exposure per ASTM B-827, B-845 Silver and gold contacts Operating Temp. -40°C to +85°C Vibration 1 Per Mil-Std 202F, Method 204D Test Condition A 0.06 DA or 10G’s 10-500 Hz. Tested with VCH connector. Test criteria - No loss of circuit during test, pre and post test contact resistance. Vibration 2 Resonance search 24-50 Hz 0.40 DA 50-2000 Hz ±10 G’s peak Horizontal Axis 3-5 G’s max. Random 24 Hz 0.06 PSD-Gsq/Hz 60 Hz 0.50 100 Hz 0.50 200 Hz 0.025 2000 Hz 0.025 No loss of circuit during test; <10μ seconds chatter. Shock Per Mil-Std 202F, Method 213B, Test Condition K @ 30G’s. Tested with VCH connector. Test criteria - No loss of circuit during test, pre and post test contact resistance. Salt Spray Per Mil-Std 202F, Method 101D, Test Condition A, 96 Hrs. Sealed version only. Dust Per Mil-Std 810C, Method 510.2 Air Velocity 300 ±200 Feet/Min, Test Duration 16 Hrs. Thermal Shock Per Mil-Std 202F, Method 107F, Test Cond. A, -55°C to +85°C. Test criteria pre and post test contact resistance Moisture Resistance Per Mil-Std 202F, Method 106F, Test Criteria - pre and post test contact resistance Ignition Protection All Contura switches with sealed construction meet the requirements of UL1500/ISO8846 for ignition protection, in addition to conformance with EC directive 94/25/EC for marine products. .830[21.08] Panel Thickness Range Gaskets Acceptable Panel Thickness 0 .030 to .250 (.76 to 6.35mm) TEST CUT 1.450[36.83] HOLE IN 1 .030 to .109 & .147 to .157 ACTUAL MATERIAL (.76 to 2.77mm & 3.73 to 3.98mm) Recommended: No gasket with panel SWITCH thickness of .032, .062, .093, .125,.187 or .250 MOUNTING HOLE www.carlingtech.com 7 V-Series Contura Sealed Rocker Switches - Contura II & III - Ordering Scheme V 1 D A B T 0 B 1 Series 2 Circuit 3 Rating 4 5 6 Termination Illumination Lamp 7 Lamp 8 Bracket 1 SERIES V 2 CIRCUIT ( ) - momentary Terminal Connections as viewed from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10 - - 9 Position: 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1A ONNONE OFF 2B (ON)NONE OFF 3C ONNONE (OFF) 4D ONNONE ON 5F ONNONE (ON) 6J ONOFF ON 7K ONOFF (ON) 8L (ON)OFF (ON) SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2 & 3 OFF S* 2 & 3, 5 & 6 2 & 3 1&2 M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2&1 E* 5 & 6 5 & 3 5&1 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 3 RATING 3 1 .4VA @ 28VDC Resistive B 15A 24V C 20A 18V D 20A 12V E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) F 10A 14V, 6A 14VT (circuit G only) M .4VA/20A 12V N .4VA/15A 24V 4 TERMINATION / BASE STYLE 8 term 10 Term Termination 12 .250 TAB (QC) no barriers AB .250 TAB (QC) with barriers JK .250 TAB (QC) no barriers 35 Solder Lug no barriers CD Solder Lug 56 Wire Leads no barriers EF Wire Leads Note: Codes J & K for circuits H, G & M. 9 Actuator 10 Lens 11 Color 12 Legend 0 00 13 14 Legend Actuator Orientation Lens Legend 6,7 LAMP (SAME CODING FOR BOTH SELECTIONS) Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* superbrightsuperbright Red AmberGreen Red 2VDC A LF R 6VDC B MG S 12VDC C NH T 24VDC D PJ V * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 8 FLUSH BRACKET COLOR 1, PANEL SEAL Black White Gray No SealB W G One SealC Y H 9 ACTUATOR 0 No Actuator A, B Contura II C, D Contura III Actuator orientation above terminals: 10 LENS 0 - No Actuator Z - No Lens ClearWhite Amber Green Red 1 6 8 G M 2 7 C H N 3 8 D J P 4 9 E K R 5 A F L S 3,6 1,4 Blue T U V W Y Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. Jumper No No Yes T2 to 5 No No No No 5 ILLUMINATION Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals S 0 NONE – – A 1 1 INDEPENDENT 8 (+) 7 (–) B 2 1 DOWN 3 (+) 7 (–) C 3 2 UP 3 (+) 7 (–) D 4 1 DOWN 3 (+) 7 (–) 2 DOWN 1 (+) 7 (–) E 5 1 UP 1 (+) 7 (–) 2 UP 3 (+) 7 (–) F 6 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 6 (–) G 7 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 7 (–) H Z 2 INDEPENDENT 8 (+) 7 (–) U Y 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 10 (+) 9 (–) SINGLE POLE SWITCHES ONLY J8 1 DOWN 3 (+) 8 (–) 2 INDEPENDENT 6 (+) 7 (–) KW 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 6 (+) 7 (–) DOUBLE POLE SWITCHES ONLY L9 1 DOWN 3 (+) 6 (–) MR 1 UP 3 (+) 6 (–) NT 1 DOWN 3 (+) 6 (–) 2 DOWN 1 (+) 4 (–) PV 1 UP 1 (+) 4 (–) 2 UP 3 (+) 6 (–) 8 A R B 00 11 ACTUATOR COLOR 1 AND TEXTURE 0 - No Actuator BlackGray Red White Soft Surface BGRW Hard Surface CHSY 12 ACTUATOR LENS OR BODY LEGENDS 2 11ON 12OFF 13 I 14O OFF ONO I 15 O O 16O O 17 O I 18 I O F N N F F F For additional legend options & codes, visit us at www.carlingtech.com. 13 LEGEND ORIENTATION 0 No legend (used with codes 11-18 in selection 12) 1 Orientation 1 2 Orientation 2 3 Orientation 3 4 Orientation 4 14 ACTUATOR LENS LEGEND 00 No legend this location / no actuator (used with codes 11-18 in selection 12) Selection 14 required when switch requires two legends. If the two legends consist of one lens and one body legend, lens legend must be specified in selection 12; body legend specified in selection 14. For legend options & codes, visit us at www.carlingtech.com. Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 Body legends not available on Soft surface actuators; White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory. 3 Additional ratings available. See V-Series Switch Accessories page. 4 Contura II available with two square lenses. Consult factory for details. www.carlingtech.com V-Series Contura Sealed Rocker Switches - Contura II & III Locking - Ordering Scheme V 1 D A S W 0 B 1 Series 2 Circuit 3 Rating 4 5 6 Termination Illumination Lock 7 Lamp 1 SERIES V 2 CIRCUIT ( ) - momentary Terminal Connections as viewed from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10 - - 9 Position: 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1A ON NONEOFF 4D ON NONEON 6J ON OFFON 7K ON OFF(ON) 8L (ON) OFF(ON) 9N OFF NONEON SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2 & 3 OFF S* 2 & 3, 5 & 6 2 & 3 1&2 M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2&1 E* 5 & 6 5 & 3 5&1 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 3 RATING 4 1 B C D E F M N .4VA @ 28VDC Resistive 15A 24V 20A 18V 20A 12V 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 10A 14V, 6A 14VT (circuit G only) .4VA/20A 12V .4VA/15A 24V 4 TERMINATION / BASE STYLE 8 term 10 Term Termination 12 .250 TAB (QC) no barriers AB .250 TAB (QC) with barriers JK .250 TAB (QC) no barriers 35 Solder Lug no barriers CD Solder Lug 56 Wire Leads no barriers EF Wire Leads Note: Codes J & K for circuits H, G & M. A Z E 00 8 Bracket 9 Actuator 10 Lens 11 Function 0 12 Legend 13 Legend Orientation 7 LAMP Lamp above terminals 3 & 6 end of switch No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* superbrightsuperbright Red AmberGreen Red 2VDC A LF R 6VDC B MG S 12VDC C NH T 24VDC D PJ V * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 8 FLUSH BRACKET COLOR 1, PANEL SEAL Black White Gray No SealB W G One SealC Y H 9 HARD SURFACE ACTUATOR 1 BlackGray Red White Contura II A BGH Contura III C DEF 3,6 Actuator orientation above terminals: 1,4 10 LENS Z - No Lens ClearWhite Amber Green Red Blue 3 8 D J P V Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. Jumper No No Yes T2 to 5 No No No No 5 ILLUMINATION & SWITCH SEALING Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals S 0 NONE – – C 3 2 UP 3 (+) 7 (–) H Z 2 INDEPENDENT 8 (+) 7 (–) DOUBLE POLE SWITCHES ONLY MR 1 UP 3 (+) 6 (–) 11 ACTUATOR LOCK FUNCTION AND COLOR 1 Lock Color Up Down Up & Down Center 3 Match Actuator A HR 1 Black BJ S 2 White CK T 3 Red DL V 4 Safety Orange EM W 5 12 ACTUATOR LENS OR BODY LEGEND 2 00 - No Legend 21 22 23 24 OFF ON O I 25 O 26 O 27 O 28 I F N F For additional legend options & codes, visit us at www.carlingtech.com. ORIENTATION OF ACTUATOR/LENS IN PANEL 13 LEGEND ORIENTATION 0 No legend (used with codes 21-28 in selection 12) 1 Orientation 1 2 Orientation 2 3 Orientation 3 4 Orientation 4 ORIENTATION 1 ORIENTATION 4 ORIENTATION 2 AZC45-1 AZC45-2 6 LOCK Lock above terminals 1 & 4 end of switch Wlock 45 45 ORIENTATION 3 Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory. 3 Only available with 3 position circuits. Center OFF and special circuits only available with center position lock function. 4 Additional ratings available. See V-Series Switch Accessories page. www.carlingtech.com 9 V-Series Contura Sealed Rocker Switches - Contura IV - Ordering Scheme V 1 D A B T 0 B 1 Series 2 Circuit 3 Rating 4 5 6 Termination Illumination Lamp 7 Lamp 8 Bracket 1 SERIES V 2 CIRCUIT ( ) - momentary Terminal Connections as viewed from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10 - - 9 Position: 123 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1A ON NONEOFF 2B (ON)NONEOFF 3C ON NONE(OFF) 4D ONNONEON 5F ON NONE(ON) 6J ONOFFON 7K ON OFF(ON) 8L (ON)OFF(ON) SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2 & 3 OFF S* 2 & 3, 5 & 6 2 & 3 1&2 M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2&1 E* 5 & 6 5 & 3 5&1 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 3 RATING 4 1 .4VA @ 28VDC Resistive B 15A 24V C 20A 18V D 20A 12V E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) F 10A 14V, 6A 14VT (circuit G only) M .4VA/20A 12V N .4VA/15A 24V 4 TERMINATION / BASE STYLE 8 term 10 Term Termination 12 .250 TAB (QC) no barriers AB .250 TAB (QC) with barriers JK .250 TAB (QC) no barriers 35 Solder Lug no barriers CD Solder Lug 56 Wire Leads no barriers EF Wire Leads Note: Codes J & K for circuits H, G & M. 10 Lens 11 Color 12 Legend 0 00 13 14 Legend Actuator Orientation Lens Legend 6,7 LAMP (SAME CODING FOR BOTH SELECTIONS) Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* superbrightsuperbright Red AmberGreen Red 2VDC A LF R 6VDC B MG S 12VDC C NH T 24VDC D P JV * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 8 FLUSH BRACKET COLOR 1, PANEL SEAL Black White Gray No SealB W G One SealC Y H 9 ACTUATOR 0 No Actuator E Contura IV, left orientation T Contura IV, left orientation, laser etched F Contura IV, right orientation R Contura IV, right orientation, laser etched Actuator orientation above terminals: 10 LENS 0 - No Actuator Z - No Lens ClearWhite Amber Green Red 1 6 8 G M 2 7 C H N 3 8 D J P 4 9 E K R 5 A F L S 1,4 3,6 Blue T U V W Y EF Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 11 ACTUATOR COLOR 1,5,6 No Actuator 0 Black C White Y Nickel D Jumper No No Yes T2 to 5 No No No No 5 ILLUMINATION & SWITCH SEALING Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals S 0 NONE – – A 1 1 INDEPENDENT 8 (+) 7 (–) B 2 1 DOWN 3 (+) 7 (–) C 3 2 UP 3 (+) 7 (–) D 4 1 DOWN 3 (+) 7 (–) 2 DOWN 1 (+) 7 (–) E 5 1 UP 1 (+) 7 (–) 2 UP 3 (+) 7 (–) F 6 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 6 (–) G 7 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 7 (–) H Z 2 INDEPENDENT 8 (+) 7 (–) U Y 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 10 (+) 9 (–) SINGLE POLE SWITCHES ONLY J8 1 DOWN 3 (+) 8 (–) 2 INDEPENDENT 6 (+) 7 (–) KW 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 6 (+) 7 (–) DOUBLE POLE SWITCHES ONLY L9 1 DOWN 3 (+) 6 (–) MR 1 UP 3 (+) 6 (–) NT 1 DOWN 3 (+) 6 (–) 2 DOWN 1 (+) 4 (–) PV 1 UP 1 (+) 4 (–) 2 UP 3 (+) 6 (–) 10 E P C 00 9 Actuator Gray H Pewter E Red S 12 ACTUATOR LENS OR BODY LEGENDS 2 11ON 12OFF 13 I 14O OFF ONO I 15 O O 16O O 17 O I 18 I O F N N F F F For additional legend options & codes, visit us at www.carlingtech.com. ORIENTATION OF ACTUATOR/LENS IN PANEL 13 LEGEND ORIENTATION 0 No legend (used with codes 11-18 in selection 12) 1 Orientation 1 2 Orientation 2 3 Orientation 3 4 Orientation 4 ORIENTATION 1 ORIENTATION 4 E8C45-100 E3C70-200 F8C45-100 F3C70-200 ORIENTATION 2 E8C45-300 F8C45-300 ORIENTATION 3 14 ACTUATOR LENS LEGEND 00 No legend this location / no actuator (used with codes 11-18 in selection 12) Selection 14 required when switch requires two legends. If the two legends consist of one lens and one body legend, lens legend must be specified in selection 12; body legend specified in selection 14. For legend options & codes, visit us at www.carlingtech.com. Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory. 3 Gloss brow is on left side of E actuator and right side of F actuator. 4 Additional ratings available. See V-Series Switch Accessories page. 5 Laser etched rocker only available with lens code Z & actuator colors black, nickel or pewter. 6 Pewter and nickel colors only available with laser etched actuator. www.carlingtech.com V-Series Contura Sealed Rocker Switches - Contura V - Ordering Scheme V 1 D A B T 0 B 1 Series 2 Circuit 3 Rating 4 5 6 Termination Illumination Lamp 7 Lamp 1 SERIES V 2 CIRCUIT ( ) - momentary Terminal Connections as viewed from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10 - - 9 Position: 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1 A ONNONE OFF 2 B (ON)NONE OFF 3 C ON NONE(OFF) 4 D ONNONE ON 5 F ONNONE(ON) 6 J ONOFF ON 7 K ONOFF(ON) 8 L (ON)OFF (ON) SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2 & 3 OFF S* 2 & 3, 5 & 6 2 & 3 1&2 M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2&1 E* 5 & 6 5 & 3 5&1 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 3 RATING 4 1 .4VA @ 28VDC Resistive B 15A 24V C 20A 18V D 20A 12V E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) F 10A 14V, 6A 14VT (circuit G only) M .4VA/20A 12V N .4VA/15A 24V 4 TERMINATION / BASE STYLE 8 term 10 Term Termination 12 .250 TAB (QC) no barriers AB .250 TAB (QC) with barriers JK .250 TAB (QC) no barriers 35 Solder Lug no barriers CD Solder Lug 56 Wire Leads no barriers EF Wire Leads Note: Codes J & K for circuits H, G & M. 9 Actuator 10 Lens 11 Color Jumper No No Yes T2 to 5 No No No No 12 Legend 0 00 13 14 Legend Actuator Orientation Lens Legend 6,7 LAMP (SAME CODING FOR BOTH SELECTIONS) Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* superbrightsuperbright Red AmberGreen Red 2VDC A LF R 6VDC B MG S 12VDC C NH T 24VDC D PJ V * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 8 FLUSH BRACKET COLOR 1, PANEL SEAL Black White Gray No SealB W G One SealC Y H 9 ACTUATOR 0 No Actuator G Contura V P Contura V, laser etched 10 Lens 0 - No Actuator Z - No Lens style & location: #1 / #2 ClearWhite Amber Green Red Blue 1 6 8 G M T bar 2 7 C H N U bar/bar 3 8 D J P V oval 4 9 E K R W oval/bar 5 A F L S Y oval/oval Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 11 ACTUATOR COLOR 1,3,5 No Actuator 0 Black C White Y Nickel D 5 ILLUMINATION & SWITCH SEALING Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals S 0 NONE – – A 1 1 INDEPENDENT 8 (+) 7 (–) B 2 1 DOWN 3 (+) 7 (–) C 3 2 UP 3 (+) 7 (–) D 4 1 DOWN 3 (+) 7 (–) 2 DOWN 1 (+) 7 (–) E 5 1 UP 1 (+) 7 (–) 2 UP 3 (+) 7 (–) F 6 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 6 (–) G 7 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 7 (–) H Z 2 INDEPENDENT 8 (+) 7 (–) U Y 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 10 (+) 9 (–) SINGLE POLE SWITCHES ONLY J8 1 DOWN 3 (+) 8 (–) 2 INDEPENDENT 6 (+) 7 (–) KW 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 6 (+) 7 (–) DOUBLE POLE SWITCHES ONLY L9 1 DOWN 3 (+) 6 (–) MR1 UP 3 (+) 6 (–) NT 1 DOWN 3 (+) 6 (–) 2 DOWN 1 (+) 4 (–) PV 1 UP 1 (+) 4 (–) 2 UP 3 (+) 6 (–) www.carlingtech.com G P C 00 8 Bracket Gray H Pewter E Red S 12 ACTUATOR LENS OR BODY LEGENDS 2,6 11ON 12OFF 13 I 14O OFF ONO I 15 O O 16O O 17 O I 18 I O F N N F F F For additional legend options & codes, visit us at www.carlingtech.com. 13 LEGEND ORIENTATION 0 No legend (used with codes 11-18 in selection 12) 1 Orientation 1 2 Orientation 2 3 Orientation 3 4 Orientation 4 ORIENTATION OF ACTUATOR/LENS IN PANEL ORIENTATION 1 4G13L ORIENTATION 4 4G MC MA 4G MA MC 3L ORIENTATION 2 4G200 MA3MC MA1MC ORIENTATION 3 14 ACTUATOR LENS LEGEND 00 No legend this location / no actuator (used with codes 11-18 in selection 12) Selection 14 required when switch requires two legends. If the two legends consist of one lens and one body legend, lens legend must be specified in selection 12; body legend specified in selection 14. For legend options & codes, visit us at www.carlingtech.com. Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory. 3 Laser Etched rocker only available with lens code Z & actuator colors black, nickel or pewter. 4 Additional ratings available. See V-Series Switch Accessories page. 5 Nickel and Pewter colors only available with laser etched actuator. 6 Consult factory for laser etched lens callout. 11 V-Series Contura Sealed Rocker Switches - Contura IV & V Locking - Ordering Scheme V 1 D A S W 0 B 3 Rating 4 5 6 Termination Illumination Lock 7 Lamp 1 SERIES V 2 CIRCUIT 3 Terminal Connections as viewed ( ) - momentary from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10 - - 9 Position: 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1A ON NONEOFF 4D ONNONE ON 6J ONOFF ON 7K ON OFF(ON) 8L (ON)OFF (ON) 9N OFFNONE ON 10 Lens 11 Function 12 Legend 13 Legend Orientation 7 LAMP Lamp above terminals 3 & 6 end of switch No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* superbrightsuperbright Red AmberGreen Red 2VDC A LF R 6VDC B MG S 12VDC C NH T 24VDC D PJ V * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 8 FLUSH BRACKET COLOR 1, PANEL SEAL Black White Gray No SealB W G One SealC Y H Actuator orientation above terminals: CONTURA V: Orientation BlackGray Red White UV WY Jumper No No Yes T2 to 5 No No No No 5 ILLUMINATION & SWITCH SEALING Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals S 0 NONE – – C 3 2 UP 3 (+) 7 (–) H Z 2 INDEPENDENT 8 (+) 7 (–) DOUBLE POLE SWITCHES ONLY MR 1 UP 3 (+) 6 (–) 6 LOCK Lock above terminals 1 & 4 end of switch. W low profile lock Y 6 9 Actuator 9 HARD SURFACE ACTUATOR CONTURA IV: Orientation BlackGray Red White Left J KL M Right NPR S 3 RATING 4 1 .4VA @ 28VDC Resistive B 15A 24V C 20A 18V D 20A 12V E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) F 10A 14V, 6A 14VT (circuit G only) M .4VA/20A 12V N .4VA/15A 24V 4 TERMINATION / BASE STYLE 8 term 10 Term Termination 12 .250 TAB (QC) no barriers AB .250 TAB (QC) with barriers JK .250 TAB (QC) no barriers 35 Solder Lug no barriers CD Solder Lug 56 Wire Leads no barriers EF Wire Leads Note: Codes J & K for circuits H, G & M. 8 Bracket high profile lock Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory. 3 Only available with 3 position circuits. Center OFF and special circuits only available with center position lock function. 4 Additional ratings available. See V-Series Switch Accessories page. 5 Located at T3-6 end of switch. 6 Contura V style only. 3,6 1,4 Actuator orientation above terminals: 3,6 1,4 10 LENS 5 Z - No Lens ClearWhiteAmberGreenRed Blue A B C D E F bar lens G H J K L M oval lens Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 11 ACTUATOR LOCK FUNCTION AND COLOR 1 Lock Color Up Down Up & DownCenter 3 Match Actuator A HR1 Black BJ S2 White CKT 3 Red DL V4 Safety Orange E M W5 Gray F GN6 12 ACTUATOR LENS OR BODY LEGEND 2 00 - No Legend 21 22 23 24 OFF ON O I 25 O 26 O 27 O 28 I F N F For additional legend options & codes, visit us at www.carlingtech.com. ORIENTATION OF ACTUATOR/LENS IN PANEL 13 LEGEND ORIENTATION 0 No legend 1 Orientation 1 2 Orientation 2 3 Orientation 3 4 Orientation 4 JHAY3-100 ORIENTATION 1 JHAY3-200 JHAY3-300 ORIENTATION 2 2 Circuit 0 ORIENTATION 4 1 Series J Z E 00 P P P P P P NHAY3-100 12 NHAY3-200 NHAY3-300 ORIENTATION 3 www.carlingtech.com V-Series Contura Sealed Rocker Switches - Contura VI WAVE - Ordering Scheme V 1 D B G N T B 2 Circuit 3 Rating 4 5 6 Termination Illumination Lamp 7 Lamp 8 Bracket 1 SERIES V 2 CIRCUIT ( ) - momentary Terminal Connections as viewed from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10 - - 9 Position: 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1A ONNONE OFF 2B (ON)NONE OFF 3C ON NONE(OFF) 4D ONNONE ON 5F ONNONE(ON) 6J ONOFF ON 7K ONOFF(ON) 8L (ON)OFF (ON) SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2 & 3 OFF S* 2 & 3, 5 & 6 2 & 3 1&2 M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2&1 E* 5 & 6 5 & 3 5&1 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 3 RATING 3 1 .4VA @ 28VDC Resistive B 15A 24V C 20A 18V D 20A 12V E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) F 10A 14V, 6A 14VT (circuit G only) M .4VA/20A 12V N .4VA/15A 24V 4 TERMINATION / BASE STYLE 8 term 10 Term Termination 12 .250 TAB (QC) no barriers AB .250 TAB (QC) with barriers JK .250 TAB (QC) no barriers 35 Solder Lug no barriers CD Solder Lug 56 Wire Leads no barriers EF Wire Leads Note: Codes J & K for circuits H, G & M. 10 Lens 11 Lens 12 Color 13 Insert Color 14 Actuator Lens 1 00 15 16 Legend Actuator Orientation Lens Legend 7 LAMP Lamp above terminals 3 & 6 end of switch No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* superbrightsuperbright Red AmberGreen Red 2VDC A LF R 6VDC B MG S 12VDC C NH T 24VDC D PJ V * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 8 FLUSH BRACKET COLOR 1, PANEL SEAL Black White Gray No SealB W G One SealC Y H 9 ACTUATOR 0 No Actuator H High Insert 10,11 LENS 4 0 - No Actuator Z - No Lens Clear White AmberGreen Red – 7 C H N 3 – D J P 4 – E K R – A F L S L Low Insert Blue U Bar Lens Translucent V Bar Lens Transparent W Oval Lens Transparent Y Oval Lens Translucent Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 12 ACTUATOR COLOR C Black H Gray Jumper No No Yes T2 to 5 No No No No 13 INSERT COLOR B Black C Bright Chrome Plated D Satin Chrome Painted S Red Y White N Bright Nickel Plated S Satin Chrome Plated T Satin Nickel Plated W White 14 ACTUATOR LENS OR BODY LEGENDS 2 00 - No Legend this location/No actuator 11ON 12OFF 13 I 14O OFF ONO I 15 O O 16O O 17 O I 18 I O F N N F F F For additional legend options & codes, visit us at www.carlingtech.com. 15 LEGEND ORIENTATION 0 No legend (used with codes 11-18 in selection 12) 1 Orientation 1 2 Orientation 2 3 Orientation 3 4 Orientation 4 Orientation 1 VTHAACN-MC1MC VTHA7CN-3M100 VTHWZCB-45146 VTLSZSC-70100 Orientation 2 5 ILLUMINATION & SWITCH SEALING Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals S 0 NONE – – A 1 1 INDEPENDENT 8 (+) 7 (–) B 2 1 DOWN 3 (+) 7 (–) C 3 2 UP 3 (+) 7 (–) D 4 1 DOWN 3 (+) 7 (–) 2 DOWN 1 (+) 7 (–) E 5 1 UP 1 (+) 7 (–) 2 UP 3 (+) 7 (–) F 6 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 6 (–) G 7 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 7 (–) H Z 2 INDEPENDENT 8 (+) 7 (–) U Y 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 10 (+) 9 (–) SINGLE POLE SWITCHES ONLY J8 1 DOWN 3 (+) 8 (–) 2 INDEPENDENT 6 (+) 7 (–) KW 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 6 (+) 7 (–) DOUBLE POLE SWITCHES ONLY L9 1 DOWN 3 (+) 6 (–) MR1 UP 3 (+) 6 (–) NT 1 DOWN 3 (+) 6 (–) 2 DOWN 1 (+) 4 (–) PV 1 UP 1 (+) 4 (–) 2 UP 3 (+) 6 (–) www.carlingtech.com H A 7 C B AC 9 Actuator Orientation 4 1 Series VTLLFHC-A813H VTLDECC-001MG Orientation 3 16 ACTUATOR LENS LEGEND 00 No legend this location / no actuator (used with codes 11-18 in selection 12) Selection 14 required when switch requires two legends. If the two legends consist of one lens and one body legend, lens legend must be specified in selection 12; body legend specified in selection 14. For legend options & codes, visit us at www.carlingtech.com. Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators. Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory. 3 Additional ratings available. See V-Series Switch Accessories page. 13 V-Series Contura Sealed Rocker Switches - Contura VII - Ordering Scheme V 1 D A B T 0 B 4 5 6 Termination Illumination Lamp 7 Lamp 1 SERIES V 2 CIRCUIT ( ) - momentary Terminal Connections as viewed from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10 - - 9 Position: 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1 A ON NONEOFF 2 B (ON)NONE OFF 3 C ON NONE(OFF) 4 D ONNONE ON 5 F ON NONE(ON) 6 J ONOFF ON 7 K ON OFF(ON) 8 L (ON)OFF (ON) SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2 & 3 OFF S* 2 & 3, 5 & 6 2 & 3 1&2 M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2&1 E* 5 & 6 5 & 3 5&1 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 3 RATING 4 1 .4VA @ 28VDC Resistive B 15A 24V C 20A 18V D 20A 12V E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) F 10A 14V, 6A 14VT (circuit G only) M .4VA/20A 12V N .4VA/15A 24V 13 14 Legend Actuator Orientation Lens Legend 6,7 LAMP (same coding for both selections) Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* superbrightsuperbright Red AmberGreen Red 2VDC A LF R 6VDC B MG S 12VDC C NH T 24VDC D PJ V * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 8 FLUSH BRACKET COLOR 1, PANEL SEAL Black White Gray No SealB W G One SealC Y H ACTUATOR ORENTATION ABOVE TERMINALS 9 ACTUATOR 0 No Actuator Z Contura VII 3,6 1,4 STANDARD 10 LENS Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 0 - No Actuator Z - No Lens White Amber Green Red Blue Lens style & location 6 B G MT 7 C H NU 8 D J PV 9 E K RW A F L SY 1 2 3 45 ORIENTATION 3 11 ACTUATOR COLOR/THUMB PRINT COLOR 1 O N/A - No Actuator CBlack/Black HGrey/Black SRed/Black YWhite/Black ORIENTATION 4 ORIENTATION 3 ORIENTATION 1 14 ACTUATOR LENS OR BODY LEGENDS 2 11ON 12OFF 13 I 14O OFF ONO I 15 O O 16O O 17 O I 18 I O F N N F F F For additional legend options & codes, visit us at www.carlingtech.com. ORIENTATION 1 AA AA 46 46 3AA-146 ORIENTATION 2 13 LEGEND ORIENTATION 0 No legend (used with codes 11-18 in selection 12) 1 Orientation 1 2 Orientation 2 3 Orientation 3 4 Orientation 4 ORIENTATION 4 Jumper No No Yes T2 to 5 No No No No 5 ILLUMINATION & SWITCH SEALING Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals 0 NONE – – A 1 1 INDEPENDENT 8 (+) 7 (–) B 2 1 DOWN 3 (+) 7 (–) C 3 2 UP 3 (+) 7 (–) D 4 1 DOWN 3 (+) 7 (–) 2 DOWN 1 (+) 7 (–) E 5 1 UP 1 (+) 7 (–) 2 UP 3 (+) 7 (–) F 6 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 6 (–) G 7 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 7 (–) H Z 2 INDEPENDENT 8 (+) 7 (–) U Y 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 10 (+) 9 (–) SINGLE POLE SWITCHES ONLY J8 1 DOWN 3 (+) 8 (–) 2 INDEPENDENT 6 (+) 7 (–) KW 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 6 (+) 7 (–) DOUBLE POLE SWITCHES ONLY L9 1 DOWN 3 (+) 6 (–) MR 1 UP 3 (+) 6 (–) NT 1 DOWN 3 (+) 6 (–) 2 DOWN 1 (+) 4 (–) PV 1 UP 1 (+) 4 (–) 2 UP 3 (+) 6 (–) 14 0 00 12 Legend ORIENTATION 2 4 TERMINATION / BASE STYLE 8 term 10 Term Termination 12 .250 TAB (QC) no barriers AB .250 TAB (QC) with barriers JK .250 TAB (QC) no barriers 35 Solder Lug no barriers CD Solder Lug 56 Wire Leads no barriers EF Wire Leads Note: Codes J & K for circuits H, G & M. 11 Color ORIENTATION 4 3 Rating 10 Lens ORIENTATION 1 2 Circuit Z R C 00 9 Actuator ORIENTATION 2 1 Series 8 Bracket 3AA-246 ORIENTATION 3 14 ACTUATOR LENS LEGEND 00 No legend this location / no actuator (used with codes 11-18 in selection 12) Selection 14 required when switch requires two legends. If the two legends consist of one lens and one body legend, lens legend must be specified in selection 12; body legend specified in selection 14. For legend options & codes, visit us at www.carlingtech.com. Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators. Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory. 3 Additional ratings available. See V-Series Switch Accessories page. 4 Legends available for lighted oval lens version only www.carlingtech.com V-Series Contura Sealed Rocker Switches - Contura X, XI & XII - Ordering Scheme V 1 D A B 6 0 1 2 Circuit 3 Rating 4 5 6 Termination Illumination Lamp 7 Lamp 1 SERIES V 2 CIRCUIT Terminal Connections as viewed ( ) - momentary from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10 - - 9 Position: 123 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1A ON NONEOFF 2B (ON)NONEOFF 3C ON NONE(OFF) 4D ONNONEON 5F ON NONE(ON) 6J ONOFFON 7K ON OFF(ON) 8L (ON)OFF(ON) SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2 & 3 OFF S* 2 & 3, 5 & 6 2 & 3 1&2 M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2&1 E* 5 & 6 5 & 3 5&1 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 3 RATING 4 1 .4VA @ 28VDC Resistive B 15A 24V C 20A 18V D 20A 12V E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) F 10A 14V, 6A 14VT (circuit G only) M .4VA/20A 12V N .4VA/15A 24V 4 TERMINATION / BASE STYLE 8 term 10 Term Termination 12 .250 TAB (QC) no barriers AB .250 TAB (QC) with barriers JK .250 TAB (QC) no barriers 35 Solder Lug no barriers CD Solder Lug 56 Wire Leads no barriers EF Wire Leads Note: Codes J & K for circuits H, G & M. 6 P Z 00 8 Bracket Jumper No No Yes T2 to 5 No No No No 10 Lens 11 Lens 12 Legend 0 00 13 14 Legend Actuator Orientation Lens Legend 6,7 LAMP (same coding for both selections) Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* superbrightsuperbright Red AmberGreen Red 2VDC A LF R 6VDC B MG S 12VDC C NH T 24VDC D PJ V * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 8 BRACKET COLOR 1, PANEL SEAL (EXTERNAL FOAM GASKET) X & XI with Flush Bracket X, XI, XII with Raised Bracket # of gaskets0 1 2 0 1 Black B C D 1 4 White WY Z 2 5 Gray GH J 3 6 9 ACTUATOR No Actuator 0 Black Gray WhiteRed Contura X 1 23 4 Contura XI 6 78 9 Contura XII J K N M Actuator orientation above terminals: 3,6 1,4 10 LENS - ABOVE LAMP #1 TERMINALS 1,4 11 LENS - ABOVE LAMP #2 TERMINALS 3,6 0 - No Actuator Z - No Lens Clear White Amber Green Red Blue Lens Style 3 8 D J PVBar 4 9 E K RW One piece Square 5 A F L SYTwo piece Square* (With clear top protective lens) 2 7 C H NUTwo piece Square* (With smoke top protective lens) 1 6 B G MTTwo piece Square* (With white top protective lens) * All bottom lenses are molded of opaque material. Consult factory for other lens colors. Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 12 ACTUATOR LENS OR BODY LEGEND 2 00 - No Legend this location/No actuator 11 ON 12 OFF 13 I 14 O OFF ON O I 15 O O 16 O O 17 O I 18 I O F N N F F F 21 22 23 24 OFF ON O I 25 O 26 O 27 O 28 I F N F For additional legend options & codes, visit us at www.carlingtech.com. 13 LEGEND ORIENTATION 3 0 No legend (used with codes 11-18 in selection 12) 1 Orientation 1 2 Orientation 2 3 Orientation 3 4 Orientation 4 6ZZ3G-100 6FFMA-4MC MA 3G ORIENTATION OF ACTUATOR/LENS IN PANEL ORIENTATION 1 ORIENTATION 2 5 ILLUMINATION & SWITCH SEALING Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals S 0 NONE – – A 1 1 INDEPENDENT 8 (+) 7 (–) B 2 1 DOWN 3 (+) 7 (–) C 3 2 UP 3 (+) 7 (–) D 4 1 DOWN 3 (+) 7 (–) 2 DOWN 1 (+) 7 (–) E 5 1 UP 1 (+) 7 (–) 2 UP 3 (+) 7 (–) F 6 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 6 (–) G 7 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 7 (–) H Z 2 INDEPENDENT 8 (+) 7 (–) U Y 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 10 (+) 9 (–) SINGLE POLE SWITCHES ONLY J8 1 DOWN 3 (+) 8 (–) 2 INDEPENDENT 6 (+) 7 (–) KW 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 6 (+) 7 (–) DOUBLE POLE SWITCHES ONLY L9 1 DOWN 3 (+) 6 (–) MR1 UP 3 (+) 6 (–) NT 1 DOWN 3 (+) 6 (–) 2 DOWN 1 (+) 4 (–) PV 1 UP 1 (+) 4 (–) 2 UP 3 (+) 6 (–) 9 Actuator ORIENTATION 4 1 Series 70 G3 A7 MC MA 6ZZ3G-1A7 6FFMA-3MC MC 6FZ70-100 ORIENTATION 3 14 ACTUATOR LENS LEGEND 00 No legend this location / no actuator (used with codes 11-18 in selection 12) Selection 14 required when switch requires two legends. If the two legends consist of one lens and one body legend, lens legend must be specified in selection 12; body legend specified in selection 14. For legend options & codes, visit us at www.carlingtech.com. Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red & gray actuators. Custom colors are available, consult factory. 3 With 2 square lenses, use selection 12 for lens above lamp 1, & selection 14 for lens above lamp 2. 4 Additional ratings available. See V-Series Switch Accessories page. 5 Not available with Contura XI rockers. www.carlingtech.com 15 V-Series Contura Sealed Rocker Switches - Contura X Locking - Ordering Scheme V 1 D A S W 0 1 1 Series 2 Circuit 3 Rating 4 5 6 Termination Illumination Lock 7 Lamp 1 SERIES V 2 CIRCUIT ( ) - momentary Terminal Connections as viewed from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10 - - 9 Position: 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1A ON NONEOFF 4D ON NONEON 6J ON OFFON 9N OFFNONEON SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2 & 3 OFF S* 2 & 3, 5 & 6 2 & 3 1&2 E* 5 & 6 5 & 3 5&1 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 3 RATING 4 1 .4VA @ 28VDC Resistive B 15A 24V C 20A 18V D 20A 12V E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) F 10A 14V, 6A 14VT (circuit G only) M .4VA/20A 12V N .4VA/15A 24V 4 TERMINATION / BASE STYLE 8 term 10 Term Termination 12 .250 TAB (QC) no barriers AB .250 TAB (QC) with barriers JK .250 TAB (QC) no barriers 35 Solder Lug no barriers CD Solder Lug 56 Wire Leads no barriers EF Wire Leads Note: Codes J & K for circuits H, G & M. Jumper No No Yes T2 to 5 No No No No 5 ILLUMINATION & SWITCH SEALING Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals S 0 NONE – – C 3 2 UP 3 (+) 7 (–) H Z 2 INDEPENDENT 8 (+) 7 (–) DOUBLE POLE SWITCHES ONLY MR1 UP 3 (+) 6 (–) 6 LOCK Lock above terminals 1 & 4 end of switch. WLock Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators; Custom colors are available, consult factory. 3 Located over T1-4 end of switch. 4 Additional ratings available. See V-Series Switch Accessories page. 5 Located over T3-6 end of switch. 1 P B 00 8 Bracket 9 Actuator 10 Lens 11 Function 12 Legend 0 13 Legend Orientation 6,7 LAMP (same coding for both selections) Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* superbrightsuperbright Red AmberGreen Red 2VDC A LF R 6VDC B MG S 12VDC C NH T 24VDC D PJ V * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 8 FLUSH BRACKET COLOR 1, PANEL SEAL Black White Gray No Gasket1 2 3 One Gasket4 5 6 9 HARD SURFACE ACTUATOR Contura X Black 1 Grey 2 Red 3 White 4 Actuator orientation above terminals: 3,6 1,4 10 LENS - ABOVE LAMP #2 TERMINALS 5 Z - No Lens Clear White Amber Green Red Blue Lens Style 3 8 D J PV Bar 4 9 E K RWOne piece Square 5 A F L SY Two piece Square* (with clear top protective lens) 27CHN U Two piece Square* (with smoke top protective lens) 1 6 B G MT Two piece Square* (with white top protective lens) * All bottom lenses are molded of opaque material. Consult factory for other lens colors. Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 11 ACTUATOR LOCK FUNCTION AND COLOR 3 Lock Color Up Down Up & Down Match Actuator A HR Black BJ S White CKT Red DL V Gray E MW Safety Orange F NY 12 ACTUATOR LENS OR BODY LEGEND 2 00 - No Legend 21 22 23 24 OFF ON O I 25 O 26 O 27 O 28 I F N F For additional legend options & codes, visit us at www.carlingtech.com. Orientation 1 13 LEGEND ORIENTATION 3 0 No legend (used with codes 11-18 in selection 12) 1 Orientation 1 2 Orientation 2 3 Orientation 3 Orientation 4 Orientation 4 4 Orientation 2 1PM4F-1 45 4F MC Orientation 3 18K45-2 13DMC-1 16 www.carlingtech.com V-Series Contura Sealed Rocker Switches - Contura XIV - Ordering Scheme V 1 D B B C 0 B 1 Series 2 Circuit 3 Rating 4 5 6 Termination Illumination Lamp 7 Lamp 8 Bracket 1 SERIES V 2 CIRCUIT ( ) - momentary Terminal Connections as viewed from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10 - - 9 Position: 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1A ON NONEOFF 2B (ON)NONEOFF 3C ON NONE(OFF) 4D ON NONEON 5F ON NONE(ON) 6J ON OFFON 7K ON OFF(ON) 8L (ON) OFF(ON) SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5&4 G* 2 & 3, 5 & 6 2 & 3 OFF M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2&1 E* 5 & 6 5 & 3 5&1 S* 2 & 3, 5 & 6 2 & 3 1&2 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 3 RATING 3 1 .4VA @ 28VDC Resistive B 15A 24V C 20A 18V D 20A 12V E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) F 10A 14V, 6A 14VT (circuit G only) 4 TERMINATION / BASE STYLE 8 term 10 Term Termination 12 .250 TAB (QC) no barriers AB .250 TAB (QC) with barriers JK .250 TAB (QC) no barriers 34 Solder Lug no barriers CD Solder Lug 56 Wire Leads no barriers EF Wire Leads Note: Codes J & K for circuits H, G & M. 10 Lens 11 Actuator Color 1 00 12 Legend 13 14 Legend Actuator, Orientation Lens Legends 6 & 7 LAMP No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* superbrightsuperbright Red AmberGreen Red 2VDC A LF R 6VDC B MG S 12VDC C NH T 24VDC D PJ V * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 8 BRACKET COLOR & PANEL SEAL Color No Gasket 1 Gasket 2 Gasket BlackB C D GrayG H J White W YZ 9 ACTUATOR STYLE 0 No Actuator - Furnished separately FA Contura XIV FB Contura XIV - Laser Etched 10 LENS COLOR / STYLE 0 - No Actuator Z - No Lens ClearWhite Amber Green Red 1 6 B G M 2 7 C H N 3 8 D J P 4 9 E K R 5 A F L S 5 A N/A N/A N/A Blue T U V W Y N/A PAD Printed Laser-Etched Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. Jumper No No Yes T2 to 5 No No No No 5 ILLUMINATION Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Lamps Illumination Type Lamp wired to Terminals S NONE – – A 1 INDEPENDENT 8 (+) 7 (–) B 1 DOWN 3 (+) 7 (–) C 2 UP 3 (+) 7 (–) D 1 DOWN 3 (+) 7 (–) 2 DOWN 1 (+) 7 (–) E 1 UP 1 (+) 7 (–) 2 UP 3 (+) 7 (–) F 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 6 (–) G 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 7 (–) H 2 INDEPENDENT 8 (+) 7 (–) SINGLE POLE SWITCHES ONLY J 1 DOWN 3 (+) 8 (–) 2 INDEPENDENT 6 (+) 7 (–) K 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 6 (+) 7 (–) DOUBLE POLE SWITCHES ONLY L 1 DOWN 3 (+) 6 (–) M 1 UP 3 (+) 6 (–) N 1 DOWN 3 (+) 6 (–) 2 DOWN 1 (+) 4 (–) P 1 UP 1 (+) 4 (–) 2 UP 3 (+) 6 (–) U 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 10 (+) 9 (–) www.carlingtech.com FA P C AB 9 Actuator 11 ACTUATOR COLOR 1 O N/A - No Actuator CBlack SRed YWhite 12 ACTUATOR LENS or BODY LEGEND 2 00 - No Legend this location/No actuator 11ON 12OFF 13 I 14O OFF ONO I 15 O O 16O O 17 O I 18 I O F N N F F F 13 LEGEND ORIENTATION 0 No legend 1 Orientation 1 2 Orientation 2 3 Orientation 3 4 Orientation 4 1 2 3 4 14 ACTUATOR / LENS LEGEND 00 No legend this location / no actuator (used with codes 11-18 in selection 12) Selection 14 required when switch requires two legends. If the two legends consist of one lens and one body legend, lens legend must be specified in selection 12; body legend specified in selection 14. For legend options & codes, visit us at www.carlingtech.com. Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators. 3 Additional ratings available. See V-Series Switch Accessories page. 17 V–Series Contura Sealed Rocker Switches - Contura II, III, & IV - Dimensional Specifications Dimensional Specifications: in. [mm] 18 www.carlingtech.com V–Series Contura Sealed Rocker Switches - Contura V, VI & VII - Dimensional Specifications Dimensional Specifications: in. [mm] CONTURA V CONTURA V SHOWN WITH BAR LENS SHOWN WITH LOW PROFILE LOCK 1.922 [48.56] 1.922 [48.56] 1.079 [27.40] 8 TERMINAL BASE W/BARRIERS .505 [12.83] .250 [6.35] X .031 [.78] .250 [6.35] X .031 [.78] SWITCH SHOWN WITH VCH CONNECTOR 8 TERMINAL www.carlingtech.com .960 [24.38] .960 [24.38] 8 TERMINAL BASE W/O BARRIERS 10 TERMINAL BASE W/O BARRIERS 8 7 8 7 1 4 1 4 2 5 2 5 3 6 3 6 10 9 BOTTOM VIEW TERMINAL ARRANGEMENT 8 TERMINAL BASE BOTTOM VIEW TERMINAL ARRANGEMENT 10 TERMINAL BASE 10 TERMINAL BASE W/O BARRIERS 0.985 [25.02] .250 [6.35] .031 [.78] .820 [20.83] .820 [20.83] .960 [24.38] 2.029 [51.53] 1.000 [25.40] .250 [6.35] X .031 [.78] .390 [9.90] 8 TERMINAL BASE W/BARRIERS 1.922 [48.82] 10 TERMINAL BASE W/BARRIER AND LAMP TERMINAL 1.020 [25.91] .505 [12.83] SHOWN WITH LARGE LENS AND BAR LENS 1.126 [28.60] 8 TERMINAL BASE W/O BARRIERS 1.020 [25.91] CONTURA VII SHOWN WITH OVAL LENS 1.950 [49.53] .080[2.03] 1.479 [37.57] 1.550 [39.37] CONTURA VI SWITCH SHOWN WITH VC1 CONNECTOR 10 TERMINAL .820 [20.83] .960 [24.38] 10 TERMINAL BASE W/O BARRIERS SWITCH SHOWN WITH VC1 CONNECTOR 10 TERMINAL 19 V–Series Contura Sealed Rocker Switches - Contura X, XI, XII & XIV - Dimensional Specifications Dimensional Specifications: in. [mm] CONTURA X SHOWN WITH RAISED BRACKET CONTURA XI CONTURA XII CONTURA XIV SHOWN WITH RAISED BRACKET AND TWO SQUARE LENSES SHOWN WITH PADDLE ACTUATOR SHOWN WITH LARGE LENS 1.928 [48.97] .350 [8.89] .667 [16.94] 1.910 [48.51] 1.910 [48.51] .426 [10.82] .350 [8.89] 1.586 [40.28] .573 [14.56] 1.305 [33.15] 1.506 [38.25] 1.370 [34.79] 1.370 [34.79] 1.370 [34.79] 8 TERMINAL BASE W/BARRIERS 10 TERMINAL BASE W/O BARRIERS 8 TERMINAL BASE W/O BARRIERS 10 TERMINAL BASE W/O BARRIERS .960 [24.38] .960 [24.38] .970 [24.64] .960 [24.38] .780 [19.81] .780 [19.81] .780 [19.81] .250 [6.35] X .031[.78] .390 [9.90] .390 [9.90] .820 [20.82] 8 TERMINAL BASE W/BARRIERS SWITCH SHOWN WITH VCH CONNECTOR 8 TERMINAL 20 .390 [9.90] .820 [20.82] .820 [20.82] 10 TERMINAL BASE W/BARRIERS .960 [24.38] 10 TERMINAL BASE W/O BARRIERS 8 1 7 4 8 7 1 4 2 5 2 5 3 6 3 6 10 9 BOTTOM VIEW TERMINAL ARRANGEMENT 8 TERMINAL BASE .820 [20.83] BOTTOM VIEW TERMINAL ARRANGEMENT 10 TERMINAL BASE SWITCHES SHOWN WITH VC1 CONNECTOR 10 TERMINAL www.carlingtech.com V-Series Contura Sealed Rocker Switches - II to XIV - Circuit Diagrams Circuit Diagrams: CIRCUIT CIRCUIT DIAGRAM CIRCUIT CIRCUIT DIAGRAM 3 1 3 2 3 5 3 3 5 3 6 2 1 3 4 2 1 2 6 3 4 2 6 4 1 1 6 5 3 3 6 5 3 2 6 5 6 G SYMBOL LEGEND SYM. 2 3 S 2 7 6 5 2 F 1 5 2 5 3 1 2 6 R 2 6 4 3 5 E 3 6 M 2 1 4 5 3 1 5 D 5 3 L 2 3 5 2 C 1 1 6 2 4 6 K 2 3 4 2 B 1 3 J 2 3 CIRCUIT DIAGRAM 1 6 A 2 CIRCUIT 2 5 DEFINITION DESIGNATES TERMINALS AND CONTACTS DESIGNATES LAMP LOCATION 1 3 3 4 DESIGNATES MAINTAINED CIRCUITS DESIGNATES OTHER POSITION 8 H DESIGNATES MOMENTARY CIRCUITS DESIGNATES TWO POSITION CONNECTION 2 www.carlingtech.com 2 5 DESIGNATES EXTERNAL JUMPER PROVIDED BY CUSTOMER 21 V-Series Contura Sealed Rocker Switches - II to XIV - Lamp Circuit Diagrams, Hazard Warning Circuit Diagrams Lamp Circuit Diagrams: LAMP CIRCUIT CIRCUIT DIAGRAM LAMP CIRCUIT +8 +8 A/1 1 -7 1 +3 +3 SPECIAL #1 +3 2 2 M/R +1 +3 -4 2 H/Z SPECIAL #3 +1 +3 2 J/8 2 2 1 N/T SPECIAL #4 +3 1 2 -7 +3 -8 1 +6 1 +8 -6 -7 -7 2 -7 +8 2 +6 1 +8 -6 +3 -7 C/3 CIRCUIT DIAGRAM -6 1 L/9 LAMP CIRCUIT -7 1 G/7 +3 +6 1 +1 +3 -4 P/V 2 -6 1 2 -7 -7 +8 +1 +3 E/5 -6 2 +8 -7 D/4 CIRCUIT DIAGRAM -7 +3 B/2 +3 1 F/6 LAMP CIRCUIT CIRCUIT DIAGRAM 1 2 K/W +6 1 U/Y 2 (-)7 -7 +8 +10 1 2 -7 -9 Hazard Warning Circuit Diagrams: CIRCUIT CIRCUIT DIAGRAM 1 17 18 10(-) 3 J1 1 2 5 3 14 11 13 CIRCUIT 10(-) J5 CIRCUIT DIAGRAM 1 3 5 1 5 3 11 13 3 14 11 13 3 14 15 12 6 16 JK 1 1 5 8 J3 2 8 17 18 10(-) 3 6 JJ 1 5 3 14 NOTE: J circuits are available for all non-locking V-Series styles. Consult factory for p/ n details. JA 17 18 10(-) J2 CIRCUIT DIAGRAM 11 13 17 18 2 2 8 CIRCUIT 8 17 18 10(-) SYMBOL LEGEND 1 J4 SYM. DEFINITION DESIGNATES TERMINALS AND CONTACTS DESIGNATES LAMP LOCATION 2 22 5 www.carlingtech.com V-Series Contura Rotary Switches - Introduction Rotary V-Series CONTURA ROTARY SWITCHES The V-Series Contura Rotary Switch was designed for maximum performance and reliability leveraging the features of the widely popular V-series Contura Rocker Switches. Available in maintained and momentary circuit options, the V-Series Rotary features a sturdy knob construction, up to three separate LEDs, and fits in an industry standard panel opening. Internally, the V-Series Contura Rotary uses a patented mechanism that translates rotary to linear motion. This allows for common switch functionality and terminal connections with the V-Series rocker version and requires no harness change. A secondary CAM, which helps drive the mechanism, provides definitive detent positions and prevents the switch from stopping between positions, while improving tactile feel. The V-Series Rotary also features an innovative PC board that supports the LED and surface mount resistors; and IP67 sealing protection above panel by utilizing LED and actuator stem seals. Together, these features make the V-Series Contura Rotary switch the best choice available in the market today. Resources: Download 3D CAD Files IGS STP Watch Product Video Product Highlights: Accommodates up to three separate LEDs Patented mechanism translates rotary into linear motion Secondary CAM for definitive detent positions PC Board supports LED and surface mount resistors IP67 sealing protection above panel Common terminal & circuit functionality with V-Series Rocker switches, with no harness change required www.carlingtech.com 23 V-Series Contura Rotary Switches - Design Features V-Series Rotary Switch DESIGN FEATURES OPTIONAL PANEL SEAL Prevents water/dust ingress behind panel LEDS Up to three separate LEDs 24 SEALS LED and stem seals provide IP67 protection above panel ROTARY & LINEAR ACTUATOR Patented mechanism that translates rotary to linear motion PC BOARD Supports LEDs and surface mount resistors TERMINALS Same pinout as V-Series Rocker Switches, requiring no harness change SECONDARY CAM Provides definitive detent positions with ball & spring located in rotary actuator www.carlingtech.com V-Series Contura Rotary Switches - General Specifications Electrical Mechanical Rating Circuit Voltage Max Current Resistive 2 Position Maintain 2 Position Momentary 3 Position All 2 Position Maintain 2 Position Momentary 12 12 12 24 24 20 20 20 15 15 3 Position All 24 15 Dielectric Strength 1500 Volts RMS Insulation Resistance 50 Megohms Initial Contact Resistance 10 Milli Ohm max @ 4VDC Life 50,000 Cycles Two Position 25,000 Cycles Two Position Momentary and All Three position Terminals 0.250” (6.3mm) Quick Connect Physical Function Circuits Double Pole Single Throw, DPST Double Pole Double Throw, DPDT Operation Two and Three Position Maintained and Momentary Knob Rotation Two Position 60 Degrees Three Position 30 Degrees from Center Illumination LED; Red, Green, Amber, Yellow, White, Blue Seals LED O-ring(s) – Silicone, Bezel gasket – Neoprene, Knob seal - NBR Flammability Exceeds FVMSS 302 Requirements, Exterior Components, UL 94 V-2 or Better Interior Components, UL 94 HB or Better Base Polyester, PBT Bracket Nylon 66, PA Knob Polybutylene Terephthalate, PBT 6.5%GF Lens Polycarbonate, PC Connector Nylon 66, PA Mounting Front Panel Snap In, 1.450” (36.83mm) X 0.830” (21.08mm) Panel Thickness, 0.030” – 0.187” (0.76 – 4.75mm) Mechanical Life Knob Impact Environmental Sealing Dust Corrosion Chemical Splash Salt Spray Vibration Random Vibration Sinusoidal Shock Handling Shock Thermal Shock Moisture Resistance Thermal Cycling Ignition Protection UV Protection ESD 100,000 Cycles Maintained Circuits 50,000 Cycles Momentary Circuits 50 Gram weight dropped from a height of 18 inches on Top & Sides IP67, in accordance with IEC 60529, BS 5490, DIN 40050 & NFC 20 010. This rating applies to front panel components of the actual switch only, and signifies protection against dust and the prolonged effects of immersion under pressure. Mil STD 810, Method 510.2 Air Velocity 300 Ft/Min Duration 16Hr IEC 68-2-60 Mixed Flowing Gas (MFG) 14 Days Gasoline, Diesel, Motor Oil, Brake Fluid, Ammonia, Armour All Mil STD 202G, Method 101, Test Condition A 96 Hr Mil STD 202G, Method 214 test Condition C 10G’s RMS Mil STD 202G, Method 204D, Test Condition A 0.06DA or 10G’s 10-500Hz MIL-STD 202G, Method 213B Test Condition K, 30G’s 1 Meter Drop onto Hard Surface MIL-STD 202G, Method 107G Test Condition A -55 C to 85 C MIL-STD 202G, Method 106F 10, 25 C to 65 C Cycles 95% RH 25 Cycles -40 C to 85 C ISO 8846 with EC Directive 94/25/EC for Marine Products 300 hr Xenon Arc, 1.4W/m2 wavelength 420 nm Human Static Discharge, +/- 15KV applied during normal operation Shipping/Handling, frequency range 200-2000 MHz applied voltage is +8KV to +15KV and -8KV to -15KV 3 discharge cycles *Manufacturer reserves the right to change product specification without prior notice. www.carlingtech.com 25 V-Series Contura Rotary Switches - Ordering Scheme RV 21 D 2 B 6 0 0 B 1 Series 2 Circuit 3 Rating 4 5 6 Termination Illumination Lamp 1 1 SERIES RV Rotary Contura 2 CIRCUIT 1 Terminal Connections as viewed ( ) - momentary from bottom of switch: 8 - - 7 DP - double pole uses 1, 2, 3 and 4, 5, 6. 1 - - 4 2 - - 5 3 - - 6 10 - - 9 Position:1 2 3 DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 21 ON NONE OFF 22 (ON) NONE OFF 23 ON NONE(OFF) 24 ON NONE ON 26 ON OFF ON 28 (ON) OFF (ON) SPECIAL CIRCUITS 55 (ON) OFF ON 61 2 & 3, 5 & 6 2 & 3, 4 & 5 1 & 2, 4 & 5 62 2 & 3, 5 & 6 2 & 3 OFF 64 (2 & 3, 5 & 6) 2 & 3 OFF 3 RATING 1 .4VA 28VDC Resistive B 15A 24V D 20A 12V 4 TERMINATION / BASE STYLE 8 Term 10 Term TerminationJumper 1 2 .250 TAB (QC) - no barriers No AB .250 TAB (QC) - with barriers No J 4, 5K 4, 5 .250 TAB (QC) - no barriers Yes (T2 to T5) Notes: 1 Switch circuit uses terminals 1,2,3,4,5 & 6. Terminals 7,8,9 & 10 are for lamp circuit only. 2 Jumper between terminals 2 & 5 for Circuits 61, 62, & 64 to be specified in the Termination & Jumper selection. 3 Circuit 61 may be used for SP, OFF-ON-ON circuit. 4 Base will not have terminal insulating barriers when connector and/or jumpers are used. 5 Code J,K are optional for circuits 62 and 64. Customer may provide externally wired jumper to connect terminals 2 and 5. 6 Lamp #1 located at top end of switch, above terminal 4. Lamp #2 located at top end of switch between terminals 1 & 4. Lamp #3 located at top end of switch, above terminal Positive (+) and negative (-) symbols apply to L.E.D. lamps only. 7 Mounting hole size is 1.450” (36.83mm) by 0.830” (21.08mm). To mount multiple switches in single panel cut-out order optional interlocking mounting panels. 8 Lens color for L.E.D.s must be clear, white, or match color of L.E.D. 7 Lamp 2 8 Lamp 3 9 Bracket 5 ILLUMINATION 6, 8 Sealed Lamps S NONE A # 1 B # 1 C # 1 & # 3 D # 1 & # 3 E # 1 # 2 # 3 F # 1 # 2 # 3 G # 1 # 3 H # 2 J # 1 # 2 K # 1 # 2 L # 1 # 2 M # 2 # 3 N # 2 # 3 P # 2 # 3 R # 3 T # 3 K R C 10 Actuator 11 Lens 12 Knob Color when illuminated Terminals Independent Dependent Independent Independent Dependent Dependent Independent Independent Independent Dependent Independent Dependent Dependent Independent Independent Independent Independent Dependent Dependent Dependent Independent Independent Independent Dependent Dependent Independent Dependent Independent Dependent 8+ 3+ 8+ 10+ 3+ 1+ 8+ 9+ 10+ 3+ 9+ 1+ 3+ 8+ 8+ 8+ 10+ 3+ 1+ 3+ 8+ 8+ 10+ 3+ 1+ 10+ 1+ 8+ 1+ 77777777777777777777777777777- 6, 7, 8 LAMP #1, 2 AND OR LAMP #3 6, 8 Selection 6: above terminal 7; Selection 8: above terminal 8 No lamp 0 LED RedAmber Green Blue White 12VDC CN H E 6 24VDC DP J K 8 9 BRACKET COLOR & PANEL SEAL 7 Color No Gasket 1 Gasket 2 Gasket Black BC D Gray GH J White WY Z 10 ACTUATOR STYLE K Rotary Knob (Standard) ACTUATOR ORIENTATION ABOVE TERMINALS 4 1 11 LENS COLOR 8 No Lens Z Clear WhiteAmber Green Red Blue 4 9E KRW 12 KNOB COLOR Black GrayRed White C HS Y 26 www.carlingtech.com V-Series Contura Rotary Switches - Dimensional Specifications Dimensional Specifications: in. [mm] 1.400 [35.56] 1.700 [43.18] .845 [21.47] 1.079 [27.40] 1.550 [39.37] 10 TERMINAL BASE W/ BARRIERS .960 [24.38] 1.126 [29.24] .250 [6.35] X .031[.78] .353 [8.64] .820 [20.83] .960 [24.38] 10 TERMINAL BASE W/O BARRIERS 8 7 1 4 2 5 3 6 10 9 BOTTOM VIEW TERMINAL ARRANGEMENT 10 TERMINAL BASE SWITCH SHOWN WITH VC1 CONNECTOR 10 TERMINAL 1.266 [32.16] 1.318 [33.48] www.carlingtech.com 27 V-Series Contura Rotary Switches - Circuit Diagrams Circuits Diagrams: LEGEND SYMBOL DEFINITION TERMINAL LOCATION MAINTAINED CIRCUIT MOMENTARY CIRCUIT INTERNAL CONNECTION (JUMPER TERMINAL) 2 POSITION CONNECTION 2 POSITION CONNECTION P1 P3 2 POSITION P1 P2 P3 3 POSITION 28 www.carlingtech.com V-Series Contura Rotary Switches - Lamp Circuit Diagrams Lamp Circuit Diagrams: www.carlingtech.com 29 V-Charger Dual Port USB 2.0 Charger– Introduction V-Charger V-Charger V-SERIES DUAL PORT USB 2.0 CHARGERS Carling Technologies USB V-Charger is designed to charge tablets, e-readers, mobile and gaming devices, digital cameras, as well as other compatible electronic devices. Providing a total current of 3.15 amps, the V-Charger delivers fast charging times even in extreme temperatures from -40˚C to +80˚C. This innovative product safeguards its electronics with integrated over-current and thermal overload protection, as well as optional load dump circuitry, assuring prolonged safe and reliable operation. The center LED indicates charging is in progress. Snap-in mounting for an industry standard 1.450” x .830” panel cutout makes installation easy. *Additionally, the V-Charger’s double torsion spring-loaded access doors automatically close and provide effortless IP64 sealing protection with precision-fit silicone rubber seals. Resources: Download 3D CAD Files IGS STP Watch Product Video Product Highlights: Dual USB Charging Ports 3.15 Amps for Faster Charging 10,000 Operating Cycles per Port IP64 Sealing Protection 12-24 V Operating Voltage Protection for Internal Components 30 www.carlingtech.com V-Charger Dual Port USB 2.0 Charger - Dual Port USB 2.0 Charger V-Charger DESIGN FEATURES DUAL USB 2.0 PORTS Total current of 3.15 amps, facilitating faster charges SEALING PROTECTION Silicone rubber seal perfectly mates with door indent to provide IP64 level of sealing protection www.carlingtech.com SPRING LOADED DOORS Stylish, wing-shaped double doors automatically close to cover and seal each port when not in use PANEL SEAL Prevents water ingress beneath panel to protect critical connections LED Green LED brightens to indicate charging is in progress MOUNTING Fits industry standard panel opening size of 1.450” x .830” 31 V-Charger Dual Port USB 2.0 Charger - General Specifications Electrical USB Type 2.0 Number of USB Ports 2 Operating Voltage 12V/24V DC power systems (9 to 29 VDC) Output Voltage 5 VDC ± 5% Max Output Current 3.15A DC Total Current Draw (No Load) 12V: 0.8 mA, 24V: 1.9 mA LED Indicator Green LED brightens when charging is in progress. Compatibility Charges mobile devices including iPad, iPhone, iPod, HTC, Galaxy, Blackberry, MP3 Players, Digital Cameras and PDA’s Life 10,000 operating cycles per port minimum Terminals Copper/silver plating 1/4” (6.3 mm) Quick Connect terminations Reverse Polarity Operational with correct polarity after reverse polarity exposure ESD 15kV air, 8 kV touch Overcurrent Protection Short Circuit Thermal Overload Protection Operation will cease if internal temperature reaches 125°C. Charging will resume after sufficient heat loss Physical Panel Opening Panel Thickness Panel Mounting Method Seals Depth Behind Panel Connection Weight Styling Port Protection 1.450” x .830” .030 - .156 inches Front Panel Insertion Silicone and Poron See Figures 1 and 2 VC1, VC2 55g (0.12 lbs) Curved USB port doors Twin, self-closing doors Environmental Sealing IP64 for front panel components when USB Ports are covered Operating Temperature -40° to +60°C at 3.15A -40° to +70°C at 2.4A -40° to +80°C at 2.1A Vibration 1 Mil-Std 202G, Method 204D, Test Condition A. 0.06DA or 10G, 10-500 Hz Shock Mil-Std 202G, Method 213B, Test Condition K @ 30-G. No loss of circuit during test. Chemical Splash Brush method with USB doors closed: diesel, gasoline, brake fluid, Windex, Armor All Thermal Shock MIL-Std 202F, Method 107D, Test Condition A, -55° to +85°C. Test Criteria: Remains functional without damage Moisture Resistance Mil-Std 202G, Method 106G. Test Criteria: Remains functional without damage Thermal Cycling 25 Cycles -40° to +85°C, 2 hours for each temperature every cycle Salt Spray Mil-Std 202G, Method 101E, Test Condition A Dust Mil-Std 841C Method 510.2 Air Velocity 300 ± 200 Ft/min, test duration: 16 Hr Mechanical Endurance 10,000 door cycles minimum *Manufacturer reserves the right to change product specification without prior notice. 32 www.carlingtech.com V-Charger Dual Port USB 2.0 Charger - Ordering Scheme, Dimensional Specifications Ordering Scheme V 1 Series USB 2 Product Type 24 3 Source Voltage G 1 1 4 LED Indicator 5 Circuit Protection 6 Termination 1 SERIES V 6 TERMINATION 1 .250 Tab 2 PRODUCT TYPE USB Charger 7 DOOR STYLE 1 Curved 3 SOURCE VOLTAGE 24 24 / 12 Volts DC 8 DOOR COLOR B Black 4 LED INDICATOR (VOLTAGE MATCHES SOURCE) G Green 9 FRAME COLOR B Black 5 CIRCUIT PROTECTION 1 Reverse Polarity, Thermal Overload & Overcurrent 10 PANEL SEAL 1 Yes 1 B B 1 7 Door Style 8 9 10 Door Color Base Color Panel Seal Dimensional Specifications: in. [mm] NEGATIVE ( – ) POSITIVE ( + ) Notes: 1 Charger to install into 1.450” X 0.830” panel opening www.carlingtech.com 33 V-Series Contura Sealed Rocker Switches - Stand-Alone Components Reduce inventory levels and cost by stocking actuators and base switches separately. Contura II, III, IV, V, VI, VII, X, XI, XII, XIV Base switches separately: specify V with code selections 2-8 in the ordering schemes. Contura II, III, IV, V Actuator only: VV with code A or C for selection 9, & with selections 10-14 in the ordering schemes. Contura VI Actuator with lenses and inserts only: VV with code selections 9-16 Contura II, III, IV, V, VII Actuator only: VV with code A, C, E, G, P or Z for selection 9 & with selections 10-14 in the ordering schemes. Contura X, XI, XII, XIV actuators with lenses separately: VV with code selections 9-14 in the ordering schemes. Panel Seal: VPS Contura X & XI actuators without lenses separately: VVR 6 1 00 1 1 Actuator Separately 2 3 Actuator Lens Style/Color Opening 4 Actuator Legend Contura XII actuators without lenses separately: VVP J 1 Z 21 1 00 5 Legend Orientation 1 Actuator 2 Style & Color 3 Lens Opening 4 Lens Opening 6 7 Legend Legend Orientation 5 Legend 1 CONTURA X & XI ACTUATOR SEPARATELY VVR 1 CONTURA XII ACTUATOR SEPARATELY VVP 2 ACTUATOR STYLE & COLOR Black Gray WhiteRed Contura X 1234 Contura XI 6789 2 ACTUATOR STYLE & COLOR JBlack K Gray N White M Red 3,4 LENS OPENING FOR Z No lens 1 Bar lens Square lens 3 LENS OPENING FOR 1 1 One bar lens 2 One bar lenses 3 One square lens 4 two square lens 5 square lens on top/ bar lens on bottom (Contura X only) 4 ACTUATOR LENS OR BODY LEGEND 00 - No Legend this location 11 ON 12 OFF 13 I 14 O OFF ON O I 15 O O 16 O O 17 O I 18 I O F N N F F F For additional legend options & codes, visit us at www.carlingtech.com. 5 LEGEND ORIENTATION 1 0 No legend 1 Orientation 1 2 Orientation 2 3 Orientation 3 4 Orientation 4 5, 7 LENS OR BODY LEGEND 2 00 - No Legend 21 22 OFF ON 2 Color posts mount toward actuator stem 25 O 26 O 27 O 28 I F N F For additional legend options & codes, visit us at www.carlingtech.com. ORIENTATION OF ACTUATOR/LENS IN PANEL 6 LEGEND ORIENTATION 3 0 No legend 1 Orientation 1 2 Orientation 2 ORIENTATION 1 ORIENTATION 2 ORIENTATION OF ACTUATOR/LENS IN PANEL ORIENTATION 1 Contura X, XI & XII actuator lens assembly separately: ORIENTATION 4 VVL 2 1 00 0 ORIENTATION 2 1 Lens Separately top lens bottom lens } 3 Lens Color 4 Legend 5 Legend Orientation 2 LENS STYLE 3 1 Bar lens 2 One Piece Square lens 3 Bottom of Two-Piece Square lens 5 1 TOP OF LENS SEPARATELY VVT 2 COLOR 1 Clear 2 Smoke 2 Lens Style 1 CONTURA X, XI & XII LENS SEPARATELY VVL 3 White 3 TRANSLUCENT LENS COLOR 1 Clear2 White3 Amber4 Green 45 Red6 Blue 4 Contura X, XI & XII actuator lens assembly: actuator stem 24 I Contura X, XI & XII top piece of 2-piece lens separately: 1 Lens Separately 23 O ORIENTATION 3 VVT 1 2 4 LENS OR BODY LEGEND 2 00 - No Legend 21 22 OFF ON two piece lens assembly 23 O 24 I 1 piece lens/bar lens are positioned the same as bottom lens for assembly, minus the top lens. Lenses snap in from bottom. Notes: 1 If actuator lens opening for 2 bar or 2 square lenses, legend orientation 0,1, or 2 must be chosen. 2 Center of actuator marking not available for Contura XII. 3 Legend is not available for bar style lens. 4 Not recommended with neon lamps. 5 Must also order top piece of 2 piece square lens separately. 25 O 26 O 27 O 28 I F N F For additional legend options & codes, visit us at www.carlingtech.com. 5 LEGEND ORIENTATION 3 0 No legend 1 Orientation 1 2 Orientation 2 3 Orientation 3 4 Orientation 4 ORIENTATION OF ACTUATOR/LENS IN PANEL ORIENTATION 1 ORIENTATION 4 ORIENTATION 2 ORIENTATION 3 34 www.carlingtech.com V-Series Contura Sealed Rocker Switches - Accessories Easily integrate Contura products into your system, with Contura Accessories Q.C. SELECTION GUIDE PART NO Contura Connectors COMPANY SERIES WIRE RANGE TIN GUIDE PLAIN Q.C. SELECTION AWG PLATED BRASS PART NO BRASS COMPANY SERIES (REF) WIRE RANGE 12 02965580 ORIENTATION MM 2 3.0 ORIENTIN 02965471 (2)16-14 2GUIDE PLAIN TATION Q.C. SELECTION Q.C.12010601 SELECTION GUIDE Q.C. GUIDE MM(2)1.0-2.0 AWGSELECTION PLATED BRASS 02965470 16-14 (REF) 1.0-2.0 BRASS WIRE WIRE WIRE PART NO PART NO PART NO PACKARD 58 SERIES B RANGE .5-.8 RANGE 02965469 06288318RANGE 02965580 12 20-18 ORIEN3.0 COMPANY COMPANY ORIENTIN TIN 10 5.0 12084590 2TIN 2 SERIES PLAIN SERIES PLAIN PLAIN TATION TATION 02965471 PLATED 12010601 (2)16-14 (2)1.0-2.0 AWG MM AWG MM AWG MM 2 PLATED PLATED BRASS BRASS12052224 BRASS (REF) 12 3.0 (REF) BRASS BRASS BRASS 02965470 16-14 1.0-2.0 B (REF) COMPANY SERIES PACKARD 58 SERIES 02965580 0296558012015870 12 12 16-14 1.0-2.0 06288318 1202965580 20-18 3.0 .5-.8 3.0 PACKARD 02965469 12010601 12010601 12010601 (2)1.0-2.0 02965471 (2)16-14 (2)16-14 02965471 (2)16-14 02965471(2)1.0-2.0 12020035 (2)22-18 (2).5-.8 METRI-PACKPACKARD PACKARD PACKARD 10 5.0 12084590 Q.C. SELECTION GUIDE 02965470 02965470 16-14 02965470 1.0-2.0 16-14 B1.0-2.0 16-14 SERIES58 58630 SERIES SERIES 58 SERIES 12015869 20-18 .5-.8 12015832 12052224 12 .5-.8 02965469 06288318 02965469 20-18 06288318 02965469 20-18 062883183.0 .5-.8 20-18 WIRE PART NO 12052222 20-22 .35-.5 12015870 16-14 RANGE 1.0-2.05.0 10 5.0 10 10 12084590 12084590 12084590 PACKARD COMPANY ORIENTIN12052224 12052224 12 (2)22-18 3.012052224 12 3.0 12 2 PLAIN TATION METRI-PACK SERIES 12020035 (2).5-.8 1.3-3 AWG 16-12 MM Q.C. SELECTION GUIDE PLATED 60253-2 60253-1 BRASS 12015870 BRASS 16-14 12015870 1.0-2.0 16-14 12015870 1.0-2.0 16-14 630PACKARD SERIES AMP PACKARD PACKARD 12015832 12015869 20-18 (2) .5-.8 (2) 1.3 16 (REF) WIRE 250 SERIES METRI-PACK 12020035 (2)22-18 12020035 (2).5-.8 (2)22-18 12020035 A (2).5-.8 (2)22-18 METRI-PACK 02965580 METRI-PACK PART NO 12 3.0 12052222 20-22RANGE .35-.5 20-18 630 SERIES 630 SERIES 630 SERIES42100-2 18-14 .8-2 FASTIN-FASTON 42100-1 12015869 20-18 12015869 20-18 12015869 12015832 12015832 12015832 COMPANY ORIEN12010601 (2)16-14.5-.8 (2)1.0-2.0 .5-.8 02965471 TIN PACKARD 2 .35-.5 SERIES PLAIN TATION 16-12 1.3-3 12052222 PLATED 20-22 12052222 20-22 12052222 20-22 60295-2 22-18 .3-.9 60295-1 02965470 16-14.35-.5 1.0-2.0 B AWG MM 58 SERIES 60253-1BRASS 60253-2 AMP (REF) BRASS 02965469 06288318 20-18 16-12 (2) 16-12 .5-.8 16-12 161.3-3 (2) 1.31.3-3 ORIENTATION TANG 3.0 (2)1.0-2.0 A B1.0-2.0 .5-.8 A B 5.0 TANG 3.0 1.0-2.0 A(2).5-.8B .5-.8 TANG TANG SYMBOL = TANG SHOWS ORIENTATION OF TANG IN SLOT SYMBOL TANG A TANG SYMBOL = SHOWS ORIENTATION OF TANG IN SLOT .35-.5 SYMBOL TANG SYMBOL =TANGSHOWS SYMBOL =TANG SYMBOL = ORIENTATION SHOWS OFORIENTATION TANG IN SHOWS SLOT OFORIENTATION TANG IN SLOT OF TANG IN SLOT 1.3-3 SYMBOL SYMBOL SYMBOL 60253-2 60253-2 60253-2 60253-1 60253-1 60253-1 250 SERIES AMPConsult Delphi AMP Packard AMP 12084590 NOTE: and/or Amp on actual part numbers and availability. B 02965580 12 3.0 10 5.0 (2) 16 18-14 (2) 1.3 (2) 16 .8-2(2) 1.3 (2) 16 (2) 1.3 FASTIN-FASTON 42100-1 42100-2 250 SERIES 250 SERIES 250 SERIES B B AMP is a registered trademark of AMP Inc. Harrisburg, PA B TANG 12010601 (2)16-14 (2)1.0-2.0 12052224 12 3.0 42100-2 18-14 42100-2 .8-218-14 42100-2 .8-218-14 .8-2 FASTIN-FASTON FASTIN-FASTON 42100-1 02965471 FASTIN-FASTON 42100-1 42100-1 Delphi Packard is 02965470 a registered trademark 22-18 of Delphi-Packard Systems Warren, Ohio PACKARD 60295-1 60295-2 .3-.9 Electrical 16-14 1.0-2.0 B 12015870 16-14 1.0-2.0 60295-1 58 SERIES PACKARD METRI-PACK 60295-2 60295-1 02965469 22-18 60295-2 22-18 60295-2 60295-1 .3-.9 06288318 12020035 20-18 (2)22-18 .3-.9 22-18 .5-.8 (2).5-.8 .3-.9 A NOTE: Delphi Packard and/or Amp on actual part numbers and availability. .820[20.83] 630 SERIES NOTE:Consult Consult Delphi NOTE: Packard Consult and/or Delphi NOTE: Amp Packard Consult on actual and/or Delphi part Amp numbers Packard on actual and/or and part availability. Amp numbers on actual and part availability. numbers and availability. 12015869 20-18 .5-.8 12015832 10 5.0 12084590 .820[20.83] AMP a registered registered trademark oftrademark AMP Inc.ofHarrisburg, PA AMP is is a AMP trademark is a registered of AMP AMP Inc. is Harrisburg, a registered AMP PA trademark Inc. Harrisburg, of AMP PAInc. Harrisburg, PA TANG 12052224 12of 3.0 of 12052222 20-22 .35-.5 Delphi Packard Packard is is Delphi a registered Packard trademark is trademark Delphi a registered ofPackard Delphi-Packard trademark is a registered Electrical Delphi-Packard trademark Systems Electrical Warren, Delphi-Packard Systems Ohio Warren, Electrical Warren, Ohio Systems Ohio ORIENTATION OF TANG IN SLOT Delphi a registered of Delphi-Packard Electrical Systems TANGOhio SYMBOL Warren, = SHOWS 12015870 1.0-2.0 16-14 16-12 1.3-3 PACKARD SYMBOL 60253-2 60253-1 AMP .820[20.83] .820[20.83] (2)22-18 (2).5-.8 A METRI-PACK (2) 16 (2) 1.3 .820[20.83] .820[20.83] .820[20.83]12020035 .820[20.83] 250.820[20.83] SERIES B 630 SERIES .820[20.83] 12015869 20-18 .5-.8 12015832 42100-2 18-14 .8-2 FASTIN-FASTON 42100-1 12052222 20-22 .35-.5 60295-2 22-18 .3-.9 60295-1 TANG SYMBOL = SHOWS ORIENTATION OF TANG IN SLOT 16-12 1.3-3 SYMBOL NOTE: AMP Consult Delphi Packard Amp on actual part numbers and availability. 60253-1and/or60253-2 .770[19.56] (2) 16 PA (2) 1.3 AMP is a registered trademark of AMP Inc. Harrisburg, 250 SERIES B Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio 42100-2 18-14 .8-2 FASTIN-FASTON 42100-1 .920[23.37] A B A B PACKARDPACKARD 630 630 PACKARD 630 VC1 VC1 B AMP, PACKARD AMP, PACKARD 58 58 PACKARD 630 VC1 VC1 B B .820[20.83] A AMP, 58 AMP, PACKARD 58 AMP, PACKARD AMP, PACKARD 58 58 PACKARD AMP, PACKARD 58 VC1 B VC2 PACKARD 630 VC2 VC1 B A PACKARD 630 VC2 VC2 1.266[32.16] AMP AMP AMPAMP AMP AMP 5 B AMP AMP, PACKARD 58 679 VC2 4 73 45 2 1.266[32.16] 1.466[37.24] 1.266[32.16] .770[19.56] .950[24.13] B 69 15 8 6 A PACKARD 630 VC2 9 .920[23.37] B 1.266[32.16] 1.466[37.24] 1.266[32.16] 1.466[37.24] 1.266[32.16] A VC2 VC2 VC2 10 10 3 23 1VC1 1053 630 6729 417VC1 845 56 96 9 10 73 4 2 51 689 10 10 3 3 2 128 1 7104 8 3 5 2 619 8 7 4 28 10 1 38 2 1 784PACKARD .920[23.37] 1.170[29.72] 1.170[29.72] 1.170[29.72] A PACKARD 630 B 1.170[29.72] .820[20.83] B AMPAMP, PACKARD 58 .920[23.37] .770[19.56] .770[19.56] .920[23.37] 60295-2 22-18 .3-.9 60295-1 .820[20.83] .920[23.37] .820[20.83] .920[23.37] .920[23.37] .920[23.37] .920[23.37] NOTE: Consult Delphi Packard and/or Amp on actual partAnumbers and availability. A AMP is a registered trademark of AMP Inc. Harrisburg, PA VC2 A A A A A .920[23.37] .920[23.37] PACKARD 630 PACKARD 630 Delphi Electrical Systems Warren, Ohio VC1Packard is a registered trademark of Delphi-Packard VC1 PACKARD 630 .770[19.56] .770[19.56] B A B B B AMP, 58 PACKARD 58AMP, PACKARD 58 AMP, PACKARDPACKARD 58 AMP, AMP, PACKARD PACKARD 58 630 3 2 1 8 7 3 4 235 1 62 8 1.466[37.24] 1 87 4 .950[24.13] 1.170[29.72] 1.466[37.24] 1.266[32.16] A A A 1.170[29.72] PACKARD 630 PACKARD 630 .950[24.13] .950[24.13] .950[24.13] PACKARD 630 1.466[37.24] 1.250[31.75] B PACKARD 630 A PACKARD PACKARD 630 630 1.250[31.75] 5 A B B AMP, PACKARD 58 AMP, PACKARD PACKARD 630 58 6 7 4 5 6 7 4 5 6 1.250[31.75]B AMP 1.266[32.16] 1.466[37.24] .770[19.56] 1.250[31.75] AMP, PACKARD 58 AMP, PACKARD 58 10MARKING 3 2 DETAIL 1A 8 MARKING DETAIL 7MARKING 4DETAIL 5DETAIL 69 A 10 3 VC22 1 DETAIL 8 7 4 5 6MARKING 9 MARKING 3 2MARKING 1 8 DETAIL 7 4 5DETAIL 6 MARKING MARKING DETAIL MARKING MARKING DETAIL DETAIL MARKING MARKING DETAIL MARKING DETAIL DETAIL DETAIL MARKING DETAIL MARKING DETAIL MARKING DETAIL MARKING AMP, PACKARD 58 1.466[37.24] AMP, PACKARD 58 AMP A PACKARD 630 FRONT VIEWB MARKING VC1 FRONT VIEW DETAIL 1.266[32.16] FRONT VIEW AMP, PACKARD 58 PACKARD 630 .920[23.37] 1.466[37.24] REAR VIEW AMP, PACKARD 58 FRONT VIEW VC1 10 3 2 1 8 VC1 CONNECTOR HOUSING 1.266[32.16] CONNECTOR HOUSING FRONT REARVIEW VIEW AMP, PACKARD 58 8 7 4 5 69 VC1 10 3 2 1 VC1 VC1 CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING A MARKING DETAIL MARKING DETAIL A 1.266[32.16] 1.466[37.24] VC1 PACKARD 630 PACKARD 630 VC1 FRONT VIEW REAR VIEW VC1 B CONNECTOR HOUSING MARKING DETAIL VC2 MARKING DETAIL FRONT VIEW AMP 69 1.466[37.24] B AMP, PACKARD 58 AMP (For AMP terminals only) MARKING DETAIL REAR VIEW PACKARD 630 REAR VIEWMARKING FRONT REAR VIEW VIEW .950[24.13] FRONT VIEW DETAIL 1.466[37.24] REAR VIEW AMP CONNECTOR HOUSING MARKING DETAIL (For AMP terminals only) REAR VIEW 10 3 2 1VC2 8 7 4 5 69 CONNECTOR HOUSING VC2 1.266[32.16] 1.466[37.24] CONNECTOR (For AMP HOUSING terminals only) B Contura X Boot (P/N VB1-01) MARKING DETAIL FRONT VIEW FRONT REAR VIEW VIEW DETAIL 1.170[29.72] REAR FRONT VIEW VIEW MARKING B REAR VIEW DETAIL 1.250[31.75] FRONT VIEW MARKING DETAIL FRONT VIEW 1.050[26.67] VC1 CONNECTOR HOUSING 1.050[26.67] VC2 CONNECTOR HOUSING (For AMP terminals only) MARKING DETAIL B FRONT AMP, PACKARDVIEW 58 3 2 1 8 REAR VIEW MARKING DETAIL REAR VIEW AMP, PACKARD 58 10 3 2 1 8 VC2 7 VC2 4 5 69 VCH VC2 VCH 3 VCH 2 1 8 7 4 5 6 CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING A A MARKING DETAIL MARKING DETAIL MARKING DETAIL VCH 1.250[31.75] 1.266[32.16] 1.466[37.24] PACKARD 630 PACKARD 630 (For AMP terminals (Foronly) AMP terminals (For only) AMP terminals only) VC2 VC2 VC2 FRONT VIEW REAR VIEW FRONT VIEW .950[24.13] MARKING DETAIL REAR VIEW 5 FRONT VIEW MARKING 1.266[32.16] .920[23.37] FRONT VIEW AMP AMP, PACKARD 58 7 4 A PACKARD 630 VC1 REARFRONT VIEW VIEW REAR B VIEW MARKING DETAIL MARKING DETAIL REAR VIEW CONNECTOR HOUSING MARKING DETAIL B REAR VIEW AMP, PACKARD 58 VCH 7 4 5 6 HOUSING VCH CONNECTOR 1.250[31.75] CONNECTOR HOUSING Additional V-Series Ratings MARKING DETAIL REAR VIEW 1.050[26.67] 1 MARKING DETAIL FRONT VIEW MARKING DETAIL REAR VIEW VCH CONNECTOR HOUSING .4VA @ 28VDC Resistive VB1-01 VB1-01 4VB1-01 10A 250VAC 1/2 HP, 15A 125 CONTURA X BOOT CONTURA X BOOT CONTURA X BOOT VAC 1/2 HP, No Agency Listings 10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, UL Recognized, CSA Certified 51 62 15A 125VAC 1/2 HP, 12(2)A 125 VAC μ T85 1.050[26.67] 15A 125VAC 1/2VB1-01 HP, 12(6)A 125 VAC T85 72 VB1-01 2.000[50.80] CONTURA X BOOT .757[19.23] .757[19.23] 250VAC, 15A 125VAC, 82 10A CONTURA X BOOT 1/2 HP 125-250VAC, 12(2)A 250 VAC μ T85 2.000[50.80] 1.050[26.67].757[19.23] VB1-01 15A 125VAC, 1/2 HP 125-250VAC, 12(6)A 250 VAC T85 92 10A 250VAC, 2.000[50.80] CONTURA X BOOT B VB1-01 15A 24V 2.000[50.80] CONTURA X BOOT C 20A 18V .757[19.23] D 20A 12V .757[19.23] E 20A 14V, 10A 14VT (circuits 1, 4, A, & D only) 3.99 [101.35] 3.99 [101.35] .757[19.23] 3.99 [101.35] F 10A 14V, 6A, 14VT (circuit G only) .757[19.23] GVRT 20A 6V VRT VRT ACTUATOR ACTUATOR ACTUATOR REMOVAL H REMOVAL 20A 3V REMOVAL 3.99 [101.35] .900 [22.86] .900 [22.86] .900 [22.86] TOOL TOOL TOOL L bracket) 15A 10A 250VAC, (For flush (For125 flush VAC, bracket) (For flush bracket) 1/2 HP 125-250 VAC; 6A 125 VAC L M VRT.4VA/20A 12V (combi-contact) ACTUATOR REMOVAL .900 [22.86] TOOL (combination gold/silver contacts for borderline dry circuit applications) (For flush bracket) 3.99 [101.35] N .4VA/15A 24V (combi-contact) 3.99 [101.35] VRT(combination gold/silver contacts for borderline dry circuit applications) 3.99 [101.35] 2.000[50.80] 2.000[50.80] 1.050[26.67] 2.000[50.80] 1.050[26.67] Contura II, III, IV & V Actuator TOP TOP TOP INSERT POINTS UNDER INSERT POINTS UNDER INSERT POINTS UNDER ACTUATOR ACTUATOR ACTUATOR HOLD FLUSH ON BRACKET ANDHOLD PUSH FLUSH ON BRACKET AND HOLD PUSH FLUSH ON BRACKET AND PUSH IN IN IN TOP TOP Removal Tool (P/N VRT) TOP TOP INSERT POINTS UNDER ACTUATOR HOLD FLUSH ON BRACKET AND PUSH IN TOP TOP TOP INSERT POINTS UNDER ACTUATOR HOLD FLUSH ON BRACKET AND PUSH IN TOP TOP www.carlingtech.com ACTUATOR REMOVAL TOOL (For flush bracket) VRT ACTUATOR REMOVAL VRT NOTESACTUATOR .900 [22.86] TOOL REMOVAL Consult factory to determine availability for individual circuits and their HP rating. (For flush bracket) .900 [22.86] TOOL flush with bracket) 1. Not (For avaiable Contura 7 or 14 rocker styles. .900 [22.86] INSERT POINTS UNDER TOP ACTUATOR INSERT HOLD POINTSFLUSH UNDER ON BRACKET AND PUSH IN ACTUATOR HOLD FLUSH ON BRACKET AND PUSH TOP IN Ratings 6 - 9 are UL, CSA & VDE certified, require terminations A or B for double pole circuits, & are not available with illumination circuits 4, 8, D, J, N, & T or with wire lead or solder lug terminations. Circuits 1, 4, A, D, H, M & E are not available with rating 6 & 8. Rating 7 & 9 only available with circuits 1, 4, A & D. Circuits 2, 3, 5, 7, 8, K, L are 1/2 HP 250VAC only with rating 8. Ratings 6 & 7 must specify lamp code 1 (125VAC neon). Ratings 8 & 9 must specify lamp code 2 (250VAC neon). Rating L available with circuits 1, 4, A & D only. 2. 35 V-Series Contura Sealed Rocker Switches - Accessories Contura Mounting Panels Dimensional Specifications: in. [mm] Contura Hole Plug Dimensional Specifications: in. [mm] 1.450 [36.83] .830 [21.08] TEST CUT HOLE IN ACTUAL MATERIAL VHP CONTURA II,III HOLE PLUG 1.240 [31.50] 1.820 [46.23] .430 [10.92] VHP CONTURA II,III HOLE PLUG VH1 STANDARD HOLE PLUG (No wing serrations) (With VC1 connector attached) 2.000 [50.80] VH2 STANDARD HOLE PLUG (With wing serrations) 1.067 [27.10] 1.928 [48.97] VH3 CONTURA IV HOLE PLUG (No wing serrations) VH4 CONTURA IV HOLE PLUG (With wing serrations) DETAIL VIEW VH1,VH3 & VH5 HOLE PLUGS (No wing serrations for ease of removal) 1.020 [25.91] VH5 CONTURA V HOLE PLUG (No wing serrations) 36 VH6 CONTURA V HOLE PLUG (With wing serrations) DETAIL VIEW VH2,VH4 & VH6 HOLE PLUGS (With wing serrations) www.carlingtech.com VP-Series Contura Illuminated Indicator - Introduction VP-Series VP-Series CONTURA ILLUMINATED INDICATORS The Illuminated Indicator is offered with removable/replaceable lamps, Contura styling, and LED illumination. As a critical safety feature, it’s illumination alerts the operator of essential system functions or malfunctions like: oil pressure, high temperature, transmission or other fluid levels, parking brake, or general system malfunction. Three different style housings (flush, raised panel, oval) assure seamless integration with Contura switches and into most any dashboard panel. Product Highlights: 3 Styles to choose from Single or double window Illumination 25 lens colors and configurations Available connector for easily installation www.carlingtech.com 37 VP-Series Contura Illuminated Indicator - Ordering Scheme VP 1 6 6 1 Series 2 3 Termination Lamp B 1 1 K K 4 Lamp 5 Housing Color 6 Lens Design 1 SERIES VP Illuminated plug H2 1 Housing only 2 H3 Lamp module only HP1-01 VP connector for oval and flush bezel only VC1-01 VP connector for raised bezel only 2 TERMINATION 1 .250 TAB 7 Lens Design 8 Lens Color 9 Lens Color 00 0 00 10 Legend 11 12 Legend Actuator Orientation Legend 8, 9 LENS (same coding for both selections) 3,4,5,6,9 Z No Lens Clear White Amber Green Red Blue Lens Style 4 9 E K RWOne piece Square/Oval 11 5 A F L SY Two piece Square* (with clear top protective lens) 27CHN U Two piece Square* (with smoke top protective lens) 1 6 B G MT Two piece Square* (with white top protective lens) *All bottom lenses are molded of opaque material. Consult factory for other lens colors. 3,4 LAMP (same coding for both selections) 4,5,6,8,9,12 No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 5 6V 6 12V 7 18V 8 24V LED* AmberGreen Red 2VDC L F R 6VDC M G S 12VDC N H T 24VDC P J V *Typical current draw for LED is 20ma. 5 HOUSING COLOR flush bracket raised bracket 13 Black B6 GrayW – WhiteR 5 Red G– 10 LAMP #1 LENS OR BODY LEGEND 5 00 No legend For legend options, visit us at carlingtech.com 11 LEGEND ORIENTATION 0 No legend 1 Orientation 1 2 Orientation 2 3 Orientation 3 4 Orientation 4 oval bezel (Contura V) 1 2 3 4 6,7 SQUARE LENS DESIGN (same coding for both selections) 4,5,6,11,12 Z no lens 1 transparent diamond square 10 2 translucent square 7 3 laser etched 10 4 transparent oval 5 translucent oval 12 LAMP #2 LENS OR BODY LEGEND 5 00 No legend For legend options, visit us at carlingtech.com Notes: 1 To order housing with lenses only, specify H2 followed by fields 5-12. (flush bezel only) 2 To order lamp module only, specify H3 followed by fields 2-3. (flush bezel only) 3 Two piece lens not available with oval bezel. 4 If only 1 lamp, specify 0 in selection 4 and Z in selections 7 & 9. 5 Lamp and lens #1 located over terminals 1A and 1B for flush & oval bezel. 6 Lamp and lens #2 located over terminals 2A and 2B for flush & oval bezel. 7 Available with 2 piece lens option only. 8 Neon lamps not recommended with blue or green lenses. 9 Green or blue lenses not recommended with neon lamps. 10 Available with one piece lens option only. 11 Oval bezel available with oval lens only. Oval lens available with oval bezel only. 12 Lamp & lens #1 located over terminals 7 & 8, & #2 located over 9 & 10 for raised bezel option. 13 Both bracket and insert will be same color. For white bracket with black insert, specify 7. For black bracket with white insert, specify 8. *Manufacturer reserves the right to change product specification without prior notice. 38 www.carlingtech.com VP-Series Contura Illuminated Indicator - Dimensional Specifications Dimensional Specifications: in. [mm] 1.910 [48.51] 1.910 [48.51] .960 [24.38] .960 [24.38] .416 [10.57] .960 [24.38] .780 [19.81] .350 [8.89] 1.440[36.58] 1.506 [38.25] .100[2.54] .820 [20.83] .900 [22.86] .40[11.4] .390 [ 9.90] 1.370 [34.79] .820 [20.82] .250 X .032 Q.C. (6.35 X 0.81) 1.015 [25.78] 2.086 [52.98] .120 [3.05] .900 [22.86] .40[11.4] PLUG SHOWN WITH VC1 CONNECTOR .820 [20.83] 1.928 [48.97] .820 [20.83] 1.440 [36.58] .250 X .032 Q.C. (6.35 X 0.81) .830 [21.08] .820 [20.83] A PACKARD 630 VC1 .920[23.37] B AMP, PACKARD 58 10 3 2 1 8 .920 [23.37] 1.450 [36.83] 1.266[32.16] TEST CUT HOLE IN ACTUAL MATERIAL HP1-01 ILLUMINATED PLUG CONNECTOR MARKING DETAIL FRONT VIEW VC1 CONNECTOR HOUSING ILLUMINATED PLUG MOUNTING HOLE (OVAL, FLUSH AND RAISED BEZELS) LAMP #1 (+)8,1A (-)7,1B LAMP #2 (+)10,2A (-)9,2B CIRCUIT DIAGRAM (OVAL, FLUSH AND RAISED BEZELS) MOUNTING PANEL THICKNESSES: .062[1.57] .250[6.35] .093[2.36] .375[9.52] .125[3.17] .500[12.70] .187[4.75] Notes: Oval and flush bezel styles use terminals 1A, 1B, 2A, 2B. Raised bezel style uses terminals 7, 8, 9, 10. www.carlingtech.com 39 W–Series Fully Sealed Rocker Switches - Introduction W-Series W-Series SEALED ROCKER SWITCHES Carling Technologies set the standard for performance and aesthetics with the widely successful, often imitated, but never duplicated, V-Series rocker switches. Building further upon that platform, Carling has once again raised the bar with the fully sealed W-Series. The W-Series’ traditional appearance features complete IP68 protection, including below the panel, where the critical connection is made from the wiring harness. When used in conjunction with the integrated connector, the totally submersible W-Series provides a seal for up to ten individual wires, assuring compatibility with even the most complex circuitry. The W-Series also offers a wide variety of accoutrements, including endless illumination options featuring dual level and multicolor LEDs, progressive and hazard warning circuits, ratings up to 10A 24V, choice of paddle, rocker, locking or laser etched actuators, hundreds of standard legend choices and the electrical performance and reliability that is the hallmark of Carling Technologies products. Product Highlights: Fully sealed and submersible IP68 protection, including below the panel Tri-seal design Connector with twin locking tabs 40 www.carlingtech.com W–Series Fully Sealed Rocker Switches - Design Features W-Series Switch DESIGN FEATURES ILLUMINATION Choice of highly reliable SMT LED or incandescent lighting with 21 dependent or independent circuit options. BODY One piece polyester 94V0 seamless body acts as an umbrella to protect critical internal components. TRI-SEAL DESIGN Sealing at actuator, an insert molded neoprene base seal, along with wire lead seals, assures water tight, fully submersible protection. ROLLER PIN Proven reliable mechanism is lubricant free and allows for 100k electrical and 250k mechanical cycles, and withstands extreme temperatures from -40˚C to +85˚C. INTEGRATED CONNECTOR Accommodates Tyco/Amp .110 junior power timer contacts with twin locking tabs to provide a safe, secure, sealed connection. *Manufacturer reserves the right to change product specification without prior notice. www.carlingtech.com 41 W–Series Fully Sealed Rocker Switches - General Specifications Electrical Contact Rating Dielectric Strength Insulation Resistance Initial Contact Resistance Life Contacts Terminals Quick Voltage Overcurrent Mechanical Endurance .4VA @ 24VDC 10 amps, 3-24VDC 1500 Volts RMS 50 Megaohms 10 milliohms max. @ 4 VDC 100,000 cycles Silver tin-oxide, 88/12 Copper with silver or gold plating Connect terminations. 3-24 VDC 15A for 50 cycles 250,000 cycles minimum Physical Lighted LED - rated 100,000 hours 1/2 life (LED is internally ballasted for voltages to 24 VDC) SealsNeoprene Base Polyester blend rated to 125C with a UL flammability rating of 94V0. Actuator Basic actuator structure molded of thermoplastic polycarbonate with a hard Nylon 66 thermoplastic surface overlay. Lens Polycarbonate rated at 100°C Function 2 & 3 Position Rocker Style Operation Maintained & Momentary Base PA 6/6 30GF (glass filled) Actuator PA 6/6 13GF Bracket PBT 10GF Connector PBT 10GF, polarized Environmental Environmental IP68, Fully sealed Corrosion/ Flowing Mixed Gas (FMG) Chemical Splash Class III 3 year accelerated exposure per ASTM B-827, B-845 Operating Temperature -40°C to +85°C, 22 cycles, 300 hours Vibration 1 Per Mil-Std 202F, Method 204D Test Condition A 0.06 DA or 10G’s 10-500 Hz. Vibration 2 Resonance search 24-50 Hz 0.40 DA 50-2000 ±10 G’s peak Results Horizontal Axis 3-5 G’s max. Random 24 Hz 0.06 PSD-Gsq/Hz 60 Hz 0.50 100 Hz 0.50 200 Hz 0.025 2000 Hz 0.025 Handling/Drop One meter onto concrete floor Salt Spray Per Mil-Std 202F, Method 101D, Test Condition A, 48 Hrs. DustIP6X Thermal Shock Per Mil-Std 202F, Method 107F, Test Condition A, -55°C to 85°C Test criteria - pre and post test contact resistance Moisture Resistance/ Humidity Per Mil-Std 202F, Method 106F, Test Criteria - pre and post test contact resistance Mounting Specifications Panel Thickness Range .032 to .125 For optimum panel fit, the following panel thicknesses are suggested: .032, .062, .093, .125 .830[21.08] Actuator Travel (Angular Displacement) 24° full throw 1.450[36.83] TEST CUT HOLE IN ACTUAL MATERIAL SWITCH MOUNTING HOLE 42 www.carlingtech.com W-Series Fully Sealed Rocker Switches - Ordering Scheme 2 Circuit 3 Rating 4 5 6 Termination Illumination Lamp 7 Lamp 8 Bracket 1 SERIES W 2 CIRCUIT ( ) - momentary Terminal Connections as viewed from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 1 - - 4 1 - - 4 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10 - - 9 Position: 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1121 ON NONEOFF 1222 (ON)NONE OFF 1323 ON NONE(OFF) 1424 ONNONE ON 1525 ON NONE(ON) 1626 ONOFF ON 1727 ON OFF(ON) 1828 (ON)OFF (ON) - 49 ONON ON 3 RATING B 10A 24V D 10A 12V G 10A 6V H 10A 3V 4 TERMINATION / BASE STYLE 2 .110 TAB (QC) www.carlingtech.com 10 Lens 11 Lens 0 00 12 Legend 13 14 Legend Actuator Orientation Lens Legend 6,7 LAMP (SAME CODING FOR BOTH SELECTIONS) Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 No lamp 0 LED* superbright Red AmberGreen White 2VDC A LF4 6VDC B MG5 12VDC C NH6 24VDC D PJ8 * Consult factory for “daylight bright”, blue/green and white LED options. Typical current draw for LED is 20ma. 8 BRACKET COLOR 1 1 Black 9 ACTUATOR 1,3 3 Black with Laser Etched A Black 10 LENS - ABOVE LAMP #1 TERMINALS 1,4 11 LENS - ABOVE LAMP #2 TERMINALS 3,6 0 - No Actuator Z - No Lens ClearWhite Amber Green Red Blue 1 - B G M T - 7 C H N U 3 - D J P V - 9 E K R W 5 A - - - - Large Transparent Large Translucent Bar Transparent Bar Translucent Laser-Etched Lens color for LEDs must be clear, white, or match color of LED. 12 ACTUATOR LENS OR BODY LEGEND 2 00 - No Legend this location/No actuator 11 ON 12 OFF 13 I 14 O OFF ON O I 15 O O 16 O O 17 O I 18 I O F N N F F F 21 22 23 24 OFF ON O I 25 O 26 O 27 O 28 I F N F For additional legend options & codes, visit us at carlingtech.com 13 LEGEND ORIENTATION 0 No legend (used with codes 11-18 in selection 12) 1 Orientation 1 2 Orientation 2 3 Orientation 3 4 Orientation 4 Orientation 1 P P P Orientation 2 5 ILLUMINATION Lamp #1:above terminals 1&4 end of switch.; Lamp #2 above terminals 3&6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only Actuator Lens Position Lamps Illumination Type Lamp Wired to Terminals O NONE A # 1 Independent 8+ 7B # 1 Down 3+ 7C # 2 Up 3+ 7D # 1 Down 3+ 7 & # 2 Down 1+ 7E # 1 Up 1+ 7 & # 2 Up 3+ 7F # 1 Independent 8+ 7 & # 2 Up 3+ 6G # 1 Independent 8+ 7 & # 2 Up 3+ 7H # 2 Independent 8+ 7Selections for Single Pole Witches Only: J # 1 Down 3+ 8 & # 2 Independent 6+ 7K # 1 Independent 8+ 7 & # 2 Independent 6+ 7Selections for Double Pole Switches Only: L # 1 Down 3+ 6M # 2 Up 3+ 6N # 1 Down 3+ 6 & # 2 Down 1+ 4P # 1 Up 1+ 4 & # 2 Up 3+ 6R # 1 Down 3+ 7 & # 2 Up 6+ 7S # 1 Down 6+ 7 & # 2 Independent 8+ 7U # 1 Independent 8+ 7 & # 2 Independent 10+ 9V # 2 Independent 10+ 9W # 1 Independent 8+ 7 & # 2 Independent 10+ 7Y # 1 & # 2 Independent in Series 8+ 7Z # 1 & # 2 Independent in Parallel 8+ 7- A 7 Z 00 9 Actuator Orientation 4 W 11 D 2 B C 0 1 1 Series P P AY3-200 P AY3-100 Orientation 3 14 ACTUATOR LENS LEGEND 2 00 No legend this location/no actuator (used with codes 11-18 in selection 12) Selection 14 required when switch requires two legends. If the two legends consist of one lens & one body legend, lens legend must be specified in selection 12; body legend specified in selection 14. For legend options & codes, visit us at carlingtech.com Notes: 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red & gray actuators; Custom colors are available, consult factory. 3 Locking rocker version is also available, consult factory for details. 43 W-Series Fully Sealed Rocker Switches - Dimensional Specifications Dimensional Specifications: in. [mm] 1.000 [25.40] 1.724 [43.78] 12° 1.962 [49.83] .418 [10.62] 1.707 [43.36] 2.162 [54.91] .031 [.79] .465 [11.81] 1.664 [42.27] .110 [2.79] SWITCH SHOWN WITH CONNECTOR INSTALLED KEYING FEATURE 1.178 [29.93] .714 [18.14] 1.080 [27.43] WCH CONNECTOR (190-31214-001) 1.200 [30.48] Notes: WCH connector is intended for use with Tyco/Amp .110 Junior Power Timer, female contacts, and wire seals. For 14-16 awg wire, specify Tyco/Amp P/N 927766-3 For 16-20 awg wire, specify Tyco/Amp P/N 927770-3 Tyco/Amp cable seal P/N 828904-1 (20-18 awg wire) or P/N 828905-1 (16-14 awg wire) is required for each individual wire lead, and Tyco/Amp cable plug, P/N 828922-1, is required to seal each unused connector opening. Consult Tyco/Amp for the cable seal recommended for your specific wire gauge and thickness. 44 www.carlingtech.com L–Series Sealed Rocker Switches - Introduction L-Series L-Series SEALED ROCKER SWITCHES The L-Series rocker switch is an innovative product offering total design flexibility, while at the same time setting new standards for performance and reliability. Its versatile design features include a neatly proportioned size that fits into an industry standard mounting hole of 1.734 x .867 (44.0mm x 22.0mm), countless unique choices for ratings, circuits, colors, illuminations and laser etched legends. These single or double pole switches also feature a broad choice of actuator styles, colors, and lenses with up to twelve terminals offering an extensive range of switch and lamp circuit options, including LED or incandescent illumination. Additionally, an optional plug-in terminal connector enables pre-wiring of wire harness. Resources: Download 3D CAD Files IGS STP Watch Product Video Product Highlights: IP67 certified sealed front panel components Withstands temperatures from -40°C to +85°C Vibration, shock, thermoshock, moisture and salt spray resistant www.carlingtech.com 45 L–Series Sealed Rocker Switches - Design Features L-Series Switch DESIGN FEATURES LED LIGHTING Utilize less current and are not affected by vibration, providing long lasting illumination. Available in 3 standard colors. LENS & LEGENDS Lens available in 2 sizes and 6 standard colors in either translucent or transparent materials. Numerous symbols and text available for imprinting or laser etching. SEAL PROTECTION Locks out elements such as water, dust & debris. Certified to IP67 for front panel components. ACTUATOR Available in rocker or paddle styles. Several standard color options also available. ROLLER PIN Eliminates need for lubricants, increasing the temperature range of the switch from -40˚ C to +85˚C [-40˚ F to 185˚ F]. TERMINALS Available with 2 industry standard termination options: .250 or .187 tabs with up to 12 terminal options. BASE Fits into industry standard mounting hole of 1.734 x .867 in [44.0mm x 22.0mm]. *Manufacturer reserves the right to change product specification without prior notice. 46 www.carlingtech.com L–Series Sealed Rocker Switches - General Specifications Electrical Environmental Contact Rating .4VA @ 24VDC (MAX) resistive 15 amps, 125VAC 10 amps, 250VAC 20 amps, 4-14VDC 15 amps, 15-28VDC Dielectric Strength 1250 Volts RMS between pole to pole 3750 Volts RMS between live parts and accessible surfaces Insulation Resistance 50 Megaohms Initial Contact Resistance 10 milliohms max. @ 4 VDC Life 100,000 cycles maintained, 50,000 cycles momentary at rated voltage and current Contacts 90/10 silver-nickel, silver tinoxide, gold Terminals Brass or copper/silver plate 3/16” (4.76mm) & 1/4” (6.3mm) Quick Connect terminations standard. Environmental IP67 for above panel components of the actual switch, representing an index of protection as applied to electrical equipment in accordance with IEC 529, BS 5490, DIN 400 50 & NFC 20 010. Corrosion Mixed Flowing Gas MFG Class III per ASTM B-827 & B-845, Method H, with 3 years exposure. Operating Temperature -40°C to + 85°C Vibration 1 Per Mil-Std 202F, Method 204D Test Condition A 0.06 DA or 10G’s 10-500 Hz. Tested with VCH connector. Test criteria - No loss of circuit during test and pre and post test contact resistance. Vibration 2 Resonance search 24-50 Hz 0.40 DA 50-2000 ±10 G’s peak Results Horizontal Axis 3-5 G’s max. Random 24 Hz 0.06 PSD-Gsq/Hz 60 Hz 0.50 100 Hz 0.50 200 Hz 0.025 2000 Hz 0.025 No loss of circuit during test; <10µ chatter. Shock Per Mil-Std 202F, Method 213B, Test Condition K @ 30G’s. Tested with VCH connector. Test criteria - No loss of circuit during test, pre, and post test contact resistance. Salt Spray Per Mil-Std 202F, Method 101D, Test Condition A, 48 Hrs. Thermal Shock Per Mil-Std 202F, Method 107F, Test Condition A, -55°C to 85°C. Test criteria - pre and post test contact resistance. Moisture Resistance Per Mil-Std 202F, Method 106F, Test Criteria - pre and post test contact resistance. Mechanical Endurance 250,000 cycles minimum Physical Lighted Incandescent - rated 10,000 hours LED - rated 100,000 hours 1/2 life (LED is internally ballasted for voltages to 24 VDC) Seals Rocker, base & bracket are sealed. Base Nylon 66 GF rated to 85°C with a flammability rating of 94V0. Actuator Basic actuator structure molded of thermoplastic polycarbonate with a hard Nylon 66 thermoplastic surface overlay. LockAcetal Lens Polycarbonate rated at 100°C Function 2 & 3 Position Rocker Style Bracket Nylon Zytel 1.970 Connector Nylon 66 rated at 85°C. Polarized. Actuator Travel (Angular Displacement) .260 [6.60] .390 [9.91] 2 position 3 positions 26° 13° from center .867 [22.02] 1.734 [44.04] 1.020 [25.91] TEST CUT HOLE IN ACTUAL MATERIAL MOUNTING HOLE .100 [2.54] 2.265 [57.53] 3.055 [77.60] Panel Thickness Range Acceptable Panel Thickness .030 to .156 (.76mm to 3.96mm) Recommended: .030, .062, .093, .125 and .156 .230 X .031 [5.84 X .79] T1 BAT T2 OUTPUT (LOAD) T3 GROUND 1.300 [33.02] www.carlingtech.com .344 [8.74] 1.570 [39.88] Mounting Specifications PADDLE STYLE ACTUATOR Q.C. SELECTION GUIDE COMPANY SERIES 47 WIRE GAGE PACKARD PART NO. AWG MM 2 12084590 12 3.0 L-Series Sealed Rocker Switches – Ordering Scheme L 11 E 3 C H N 1 2 Circuit 3 Rating 4 5 6 Termination Illumination Lamp 7 Lamp 1 SERIES L 2 CIRCUIT 2 Terminal Orientation 9 Actuator 1 48 10 11 12 Lens Style Lens Style Legend & Color & Color 13 14 Legend Actuator Orientation Lens Legend 5 ILLUMINATION Lamp #1:above terminals 9 & 10 end of switch.; Lamp #2 above terminals 11 & 12 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only. ( ) - momentary SP - single pole - uses terminals 1, 2 & 4. DP - double pole uses terminals 5, 6 & 8. Terminals 9, 10 & 11 for lamp circuit only. Position:1 2 SP DP 2 & 4, 6 & 8 Connected Terminals 1121 ONNONE 1222 (ON)NONE 1323 ONNONE 1424 ONNONE 1525 ON NONE 1626 ONOFF 1727 ON OFF 1828 (ON) OFF CIRCUITS WITH JUMPER TERMINALS 30* (2,4&5), (1,6&8) OFF, OFF 31 1, 2 & 5 2, 3 & 7 PROGRESSIVE CIRCUITS 51 3 & 4 2, 3 52 3 & 4 2, 3 53 (3 & 4) 2, 3 54 (3 & 4) 2, 3 55 (3 & 4) 2, 3 56 (3 & 4) 2, 3 57 3 & 4 2, 3 58* 2 & 4 2, 3 61 3 & 4, 7 & 8 2 & 3, 6 & 7 62 3 & 4, 7 & 8 2 & 3, 6 & 7 63 (3 & 4), (7 & 8) 2 & 3, 6 & 7 64 (3 & 4), (7 & 8) 2 & 3, 6 & 7 65 (3 & 4), (7 & 8) 2 & 3, 6 & 7 66 (3 & 4), (7 & 8) 2 & 3, 6 & 7 67 3 & 4, 7 & 8 2 & 3, 6 & 7 68 2 & 4, 7 & 8 2 & 4, OFF 69* 2 & 4, 1, 7 & 8 2 & 4, OFF 70 (2 & 4), (7 & 8) 2 & 4, 5 & 7 71 (2&4), (7 & 8) 2 & 4, 5 & 7 72 2 & 4, 7 & 8 2 & 4, 5 & 7 73 (2 & 4), (7 & 8) 2 & 4, OFF 80 2 & 4, 6 & 8 2 & 4, OFF HAZARD WARNING CIRCUITS A2 6,7 & 8, 3 & 4 NONE A3 6,7 & 8, 2 & 4 NONE * Available with ratings 1, 4, & E only. 3 1 & 2, 5 & 6 OFF OFF (OFF) ON (ON) ON (ON) (ON) (1,2&8), (4,5&6) 2, 4 & 8 1&2 OFF 1&2 (OFF) (1 & 2) (OFF) (OFF) 1&2 1 & 2, 5 & 6 OFF, OFF 1 & 2, 5 & 6 OFF, OFF (1 & 2), (5 & 6) (OFF, OFF) (OFF, OFF) OFF, OFF OFF, OFF (1 & 2), (5 & 7) 1 & 2, 5 & 7 1 & 2, 5 & 7 OFF, OFF OFF, 5 & 6 OFF, 1 & 2 OFF, 1 & 2 3 RATING 2 1 .4VA @ 28VDC Resistive 4 10A 250VAC 1/2 HP, 15A 125VAC 1/2 HP, No Listings B 15A 24V C 20A 18V D 20A 12V E 15A 12V G 20A 6V H 20A 3V 4 TERMINATION 2,3 1 3 3 A A 45 8 Bracket .250 (6.4mm) TAB (QC) .187 (4.7mm) TAB (QC) Lamps Illumination Type None # 1 Independent # 2 Independent # 1 Independent & # 2 Independent # 1 Dependent # 1 Independent & # 2 Dependent # 1 Independent & # 2 Dependent # 1 Dependent & # 2 Independent # 1 Both Independent & # 2 (in series) # 1 Dependent & # 2 Dependent # 2 Hazard # 1 Hazard Lamp Wired to Terminals 10+ 12+ 10+ 12+ 4+ 10+ 4+ 10+ 8+ 4+ 10+ 10+ 9119999999999- 4+ 1+ 6+ 6+ 991010- 1212- 6,7 LAMP (SAME CODING FOR BOTH SELECTIONS) Selection 6: above terminals 10 & 9; Selection 7: above terminals 12 & 11 No lamp 0 Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* Red AmberGreen 2VDC A LF 6VDC B MG 12VDC C NH 24VDC D PJ * Consult factory for “daylight bright”, blue/green and white LED options. Typical current draw for LED is 20ma. 8 BRACKET COLOR 1 Standard Bracket Rockerguard at Lamp 1 Rockerguard at Lamp 2 Black White Gray Red 1 2 34 A B CD E F GH 9 ACTUATOR STYLE AND COLOR 1 Black White Gray Red Laser Etched Rocker A B C D3 Paddle J N K M4 10 & 11 LENS STYLE AND COLOR Lens color for LEDs must be clear, white, or match color of LED. 0 - No Actuator Z - No Lens ClearWhite Amber Green Red Blue 1 - B G M T Large Transparent - 7 C H NU Large Translucent 3 - D J PV Bar Transparent - 9 E K RW Bar Translucent 5A - - -- Laser Etched background color 12 LASER ETCHED, LENS OR BODY LEGEND 00 No legend this location / no actuator For legend options & codes, visit us at carlingtech.com 13 LEGEND ORIENTATION 0 No legend (used with codes 11-18 in selection 12) 1 Orientation 1 - vertical, lamp 1 on top 2 Orientation 2 - horizontal, lamp 1 on right 3 Orientation 3 - vertical, lamp 1 on bottom 4 Orientation 4 - vertical, lamp 1 on left Orientation 1 AA 46 AA 46 3AA-146 Orientation 2 Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 Circuits 30, 31, 58, 69 are not available with rating codes 4, C, D, G or H. 3 Termination 3 only available with rating codes 1, B, and E. 4 Not available with circuits 11-18, 51-57 and 69. S A B C D E F 4 G H J 1 2 Orientation 4 1 Series 3AA-246 Orientation 3 14 ACTUATOR LENS LEGEND 00 No legend this location / no actuator For legend options & codes, visit us at carlingtech.com 48 www.carlingtech.com L-Series Sealed Rocker Switches - Locking - Ordering Scheme L 11 D 1 S W C J 3 Rating 7 Lamp 1 SERIES L 9 Actuator 10 Lens 11 Lock 0 12 Legend 13 Legend Orientation 6 LOCK W Lock above terminals 10 & 9. 2 CIRCUIT 5 Terminal Orientation ( ) - momentary SP - single pole - uses terminals 1, 2 & 4. DP - double pole uses terminals 5, 6 & 8. Terminals 9, 10 & 11 for lamp circuit only. Position:1 2 SP DP 2 & 4, 6 & 8 Connected Terminals 1121 ONNONE 1424 ONNONE 1626 ONOFF 1727 ON OFF 1828 (ON) OFF CIRCUITS WITH JUMPER TERMINALS 30 2 (2,4&5), (1,6&8) OFF, OFF 31 2 1, 2 & 5 2, 3 & 7 PROGRESSIVE CIRCUITS 51 3 & 4 2, 3 52 3 & 4 2, 3 53 (3 & 4) 2, 3 54 (3 & 4) 2, 3 55 (3 & 4) 2, 3 56 (3 & 4) 2, 3 57 3 & 4 2, 3 58 2 & 4 2, 3 61 3 & 4, 7 & 8 2 & 3, 6 & 7 62 3 & 4, 7 & 8 2 & 3, 6 & 7 63 (3 & 4), (7 & 8) 2 & 3, 6 & 7 64 (3 & 4), (7 & 8) 2 & 3, 6 & 7 65 (3 & 4), (7 & 8) 2 & 3, 6 & 7 66 (3 & 4), (7 & 8) 2 & 3, 6 & 7 67 3 & 4, 7 & 8 2 & 3, 6 & 7 68 2 & 4, 7 & 8 2 & 4, OFF 69 2 & 4, 1, 7 & 8 2 & 4, OFF 70 (2 & 4), (7 & 8) 2 & 4, 5 & 7 71 (2&4), (7 & 8) 2 & 4, 5 & 7 72 2 & 4, 7 & 8 2 & 4, 5 & 7 73 (2 & 4), (7 & 8) 2 & 4, OFF 80 2 & 4, 6 & 8 2 & 4, OFF 3 1 & 2, 5 & 6 OFF ON ON (ON) (ON) (1,2&8), (4,5&6) 2, 4 & 8 1&2 OFF 1&2 (OFF) (1 & 2) (OFF) (OFF) 1&2 1 & 2, 5 & 6 OFF, OFF 1 & 2, 5 & 6 OFF, OFF (1 & 2), (5 & 6) (OFF, OFF) (OFF, OFF) OFF, OFF OFF, OFF (1 & 2), (5 & 7) 1 & 2, 5 & 7 1 & 2, 5 & 7 OFF, OFF OFF, 5 & 6 3 RATING 2 1 .4VA @ 28VDC Resistive 4 10A 250VAC 1/2 HP, 15A 125VAC 1/2 HP, No Listings B 15A 24V C 20A 18V D 20A 12V E 15A 12V G 20A 6V H 20A 3V 4 TERMINATION 4 1 .250 (6.4mm) TAB (QC) 3 .187 (4.7mm) TAB (QC) 7 LAMP Above terminals 12 & 11 No lamp 0 Incandescent 4 3V 5 6V 6 12V LED* Red AmberGreen 2VDC A LF 6VDC B MG 12VDC C NH 24VDC D PJ 7 18V 8 24V * Consult factory for “daylight bright”, blue/green and white LED options. Typical current draw for LED is 20ma. 8 BRACKET COLOR 1 J Black 9 ACTUATOR STYLE AND COLOR 1 BlackRed Locking Rocker PR 10 & 11 LENS STYLE AND COLOR Lens color for LEDs must be clear, white, or match color of LED. 0 - No Actuator Z - No Lens ClearWhite Amber Green Red Blue 1 - B G M T Large Transparent - 7 C H NU Large Translucent 3 - D J PV Bar Transparent - 9 E K RW Bar Translucent 11 LOCK FUNCTION AND COLOR Locking Position Up Down Up & Down Center 3 AH R 1 BJ S 2 CK T 3 DL V 4 EM W 5 Lock Color Match Actuator Black White Red Safety Orange 12 LASER ETCHED, LENS OR BODY LEGEND 00 No legend this location / no actuator For legend options & codes, visit us at carlingtech.com 13 LEGEND ORIENTATION 0 No legend (used with codes 11-18 in selection 12) 1 Orientation 1 - vertical, lamp 1 on top 2 Orientation 2 - horizontal, lamp 1 on right 3 Orientation 3 - vertical, lamp 1 on bottom 4 Orientation 4 - vertical, lamp 1 on left ORIENTATION OF ACTUATOR/LENS IN PANEL ORIENTATION 1 LOCK P LOCK PZAY2-2 LOCK P P LOCK ORIENTATION 2 2 Circuit P M H 00 8 Bracket ORIENTATION 4 1 Series 4 5 6 Termination Illumination Lock P 5 ILLUMINATION Lamp #1:above terminals 9 & 10 end of switch.; Lamp #2 above terminals 11 & 12 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only. S B Lamps None # 2 P P Illumination Type Lamp Wired to Terminals Independent 12+ LOCK LOCK PZAY2-1 ORIENTATION 3 11- Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 Additional lamp circuits available. Consult factory. 3 Available only with 3 position circuits. 4 Termination 3 only available with ratings 1, B and E. 5 Circuits 30, 31, 58 and 69, are not available with rating codes 4, C, D, G or H. www.carlingtech.com 49 L-Series Sealed Rocker Switches - Dimensional Specifications Dimensional Specifications: in. [mm] L-SERIES L-SERIES SHOWN WITH LASER ETCHED ACTUATOR SHOWN WITH ROCKER GUARD 1.970 [50.04] 1.020 [25.91] .435 [10.16] .400 [10.16] 1.450 [36.83] .855 [21.72] L-SERIES L-SERIES SHOWN WITH LARGE LENS AND PADDLE ACTUATOR SHOWN WITH BAR LENS, LOCK AND CONNECTOR 1.970 [50.04] 1.020 [25.91] .453 [11.51] .400 [10.16] Connector LC1-01 LC2-01 LC3-01 12 4 3 2 1 10 12 4 3 2 1 10 Hole Plug L-SERIES CONNECTOR 2.380 [60.45] L-SERIES HOLE PLUG LH1 BLACK .250 TAB CONNECTOR (PACKARD 630 SERIES) BLACK .187 TAB CONNECTOR (PACKARD 480 SERIES) 1.970 [50.04] BLACK .250 TAB CONNECTOR (AMP ONLY) REMOVABLE HOLE PLUG WITH NON-SERRATED WINGS LH2 HOLE PLUG WITH SERRATED WINGS 1.020 [25.91] .500 [12.70] 1.325 [33.66] .920 [23.37] 1.710 [43.43] 50 .790 [20.07] .300 [7.62] .855 [21.72] www.carlingtech.com L-Series Sealed Rocker Switches - Dimensional Specifications Dimensional Specifications: in. [mm] +.008 -.000 +.008 -.000 .984 [25.00] 2.020 [51.31] R .093 MAX TYP R .093 MAX TYP MOUNTING PANEL TEST CUT HOLE IN ACTUAL MATERIAL TEST CUT HOLE IN ACTUAL MATERIAL +.008 -.000 1.900 [48.26] FOR ADDITIONAL UNITS, ADD 1.03 [26.2] PER UNIT. FOR MORE THAN 2 L-SERIES SWITCHES, ADD MIDDLE SECTION. AVAILABLE IN PANEL THICKNESSES LISTED BELOW. CONSULT FACTORY +.008 -.000 1.900 [48.26] DIMENSIONS: LME 2.02 [51.3mm] PLUS NUMBER OF CENTER BEZELS (LMM) X 1.034 [26.26mm] LMS MOUNTING PANEL HOLE MOUNTING PANEL THICKNESS .062 [1.57] .093 [2.36] .125 [3.17] .156 [3.96] MOUNTING PANEL OPENING (2) UNITS 2.300 [58.42] 2.300 [58.42] 1.187 [30.15] 1.030 [26.16] LME MOUNTING PANEL END 1.990 [50.55] 2.300 [58.42] 1.340 [34.04] LMM MOUNTING PANEL MIDDLE LMS MOUNTING PANEL 1.700 [43.18] 1.030 [26.16] 1.030 [26.16] .670 [17.02] 2.300 [58.42] 2.300 [58.42] 3.400 [86.36] 4.430 [112.52] LM3 MOUNTING PANEL PANEL OPENING SIZE: 1.90 X 3.06 [48.3mm X 77.7mm] LM4 MOUNTING PANEL PANEL OPENING SIZE: 1.90 X 4.09 [48.3mm X 103.9mm] 1.030 [26.16] .670 [17.02] 2.300 [58.42] 6.490 [164.85] LM6 MOUNTING PANEL PANEL OPENING SIZE: 1.90 X 6.15 [48.3mm X 156.2mm] www.carlingtech.com 51 L-Series Sealed Rocker Switches - Circuit Diagrams Circuit Diagrams: CIRCUIT CODE CIRCUIT CODE SCHEMATIC 5 4 4 11 22 6 2 4 2 23 2 6 2 1 13 4 2 1 14 2 6 4 54 2 2 1 4 15 6 4 8 5 26 2 4 1 16 1 2 6 4 6 2 1 18 4 2 1 3 31 2 6 2 21 6 4 3 4 58 2 8 1 8 5 30 4 3 57 2 4 4 8 5 28 1 4 3 8 5 2 17 3 56 2 4 4 1 2 6 4 27 1 2 55 2 1 4 3 8 5 25 1 3 53 2 4 4 1 8 5 24 1 4 3 52 2 4 3 5 4 12 SCHEMATIC 1 51 2 52 CIRCUIT CODE SCHEMATIC 4 5 7 2 8 1 3 5 7 2 4 6 8 61 2 www.carlingtech.com L-Series Sealed Rocker Switches - Circuit Diagrams Circuit Diagrams: CIRCUIT CODE CIRCUIT CODE SCHEMATIC 3 SCHEMATIC 7 1 62 4 5 4 5 8 71 2 4 1 3 6 8 5 7 2 1 7 63 8 72 2 4 6 7 2 8 3 4 7 64 8 73 2 4 1 3 6 7 2 8 5 5 4 7 65 8 80 2 4 6 6 2 8 3 4 7 5 1 8 81 66 2 4 6 6 2 8 3 1 7 67 5 4 8 82 2 4 6 6 3 8 8 4 1 68 2 3 4 7 8 A2 INTERNAL CONNECTION 7 2 6 8 4 1 69 1 4 7 8 A3 INTERNAL CONNECTION 7 2 1 4 2 5 6 8 70 2 www.carlingtech.com 7 53 L-Series Sealed Rocker Switches - Lamp Circuit Diagrams Lamp Circuit Diagrams: ILLUMIN. CODE ILLUMIN. CODE SCHEMATIC -9 A SCHEMATIC -9 J 1 +1 +4 1 2 +10 -11 B 2 -12 1 INTERNAL CONNECTION +10 +12 -9 C -12 1 2 +10 -9 D 2 2 INTERNAL CONNECTION 1 +10 +12 +4 (–)9 K 1 1 (+)10 -9 E +4 2 1 LEGEND SYMBOL +10 -9 DEFINITION TERMINAL LOCATION +8 LAMP LOCATION F 1 MAINTAINED CIRCUIT 2 MOMENTARY CIRCUIT INTERNAL CONNECTION (JUMPER TERMINAL) +10 -9 +4 2 POSITION CONNECTION G 1 2 P3 P1 2 POSITION +10 -9 P3 H 1 2 P2 P1 3 POSITION +10 54 www.carlingtech.com LP-Series Illuminated Indicators - Introduction LP-Series LP-Series ILLUMINATED INDICATORS The LP-Series Illuminated Indicators are the perfect complement to the aesthetics, reliability and performance of our L-Series rocker switches. As a critical safety feature, the illumination alerts the operator of essential system functions or malfunctions, such as: Oil Pressure, High Temperature, Transmission or other fluid levels, Parking Brake or General System confirmations. The L-Series styling assures seamless integration into most any dashboard panel. Product Highlights: Vibration, Shock, and Thermoshock Resistant 12 or 24 Volts Laser Etched or Lens Illumination IP67 Sealing www.carlingtech.com 55 LP-Series Illuminated Indicators - General Specifications Electrical Terminals Brass or copper/silver plate 3/16” (4.76mm) & 1/4” (6.3mm) Quick Connect terminations standard. Lighted Incandescent - rated 10,000 hours LED - rated 100,000 hours 1/2 life (LED is internally ballasted for voltages to 24VDC) Physical Seals Base Insert Connector Markings Bracket Insert, base & bracket are sealed. Nylon 66 GF rated to 85°C with a flammability rating of 94VO. Polycarbonate rated at 100°C. Nylon 66 rated at 85°C. Polarized Over 1000 pad printed or laser etched legends available Nylon 66 GF rated to 85°C Mounting Specifications .867 [22.02] 1.734 [44.04] 1.020 [25.91] TEST CUT HOLE IN ACTUAL MATERIAL MOUNTING HOLE Panel Thickness Range Acceptable Panel Thickness .030 to .156 (.76mm to 3.96mm) Recommended: .030, .062, .093, .125 and .156 3.055 [77.60] PADDLE STYLE ACTUATOR Q.C. SELECTION GUIDE COMPANY SERIES PACKARD PART NO. PACKARD METRI-PACK 630 SERIES TIN PLATED BRASS 12084590 12052224 12015870 12015869 12020035 12052222 WIRE GAGE AWG MM 2 Environmental Environmental IP67, representing an index of protection as applied to electrical equipment in accordance with IEC 529, BS 5490, DIN 400 50 & NFC 20 010. Corrosion Resistance Mixed Flowing Gas MFG Class III per ASTM B-827 & B-845, Method H, with 3 years exposure. Operating Temperature -40°C to +85°C Vibration 1 Per Mil-Std 202F, Method 204D Test Condition A 0.06 DA or 10G’s 10- 500 Hz. Tested with VCH connector. Test criteria - No loss of circuit during test and pre and post test contact resistance. Vibration 2 Resonance search 24-50 Hz 0.40 DA 50-2000 ±10 G’s peak Results Horizontal Axis 3-5 G’s max. Random 24 Hz 0.06 PSD-Gsq/Hz 60 Hz 0.50 100 Hz 0.50 200 Hz 0.025 2000 Hz 0.025 No loss of circuit during test; <10µ chatter. Shock Per Mil-Std 202F, Method 213B, Test Condition K @ 30G’s. Tested with VCH connector. Test criteria - No loss of circuit during test, pre, and post test contact resistance. Salt Spray Per Mil-Std 202F, Method 101D, Test Condition A, 48 Hrs. Thermal Shock Per Mil-Std 202F, Method 107F, Test Condition A, -55°C to 85°C. Test criteria - pre and post test contact resistance. Moisture Resistance Per Mil-Std 202F, Method 106F, Test Criteria - pre and post test contact resistance. 3.0 12 12 3.0 2.0-1.0 16-14 1.0-.80 20-18 22-18 (2 REQ'D) .80.-.50 (2 REQ'D) .50-.35 20-22 *Manufacturer reserves the right to change product specification without prior notice. 56 www.carlingtech.com LW-Series Wiper/Washer Control - Ordering Scheme, Dimensional Specifications LP 1 H R R 5 1 Series 2 3 Termination Illumination 4 Lamp 5 Lamp 6 Bracket Color 2 TERMINATION 3 1 .250 (8.35) x .032 (0.51) Quick Connect 3 .187 (4.75) x .032 (0.51) Quick Connect LAMP WIRED TO TERMINALS 10 (+) 8 (–) 10 (+) 8 (–) 12 (+) 11 (–) 10 (+) 8 (–) 12 (+) 8 (–) 10 (+) 8 (–) 10 (+) 8 (–) LAMP 1 LOCATED ABOVE TERMINALS 9 & 10 END OF BRACKET. LAMP 2 LOCATED ABOVE TERMINALS 11 & 12 END OF BRACKET. POSITIVE (+) AND NEGATIVE (–) SYMBOLS APPLY TO LED LAMPS ONLY. 4,5 LAMP (same coding for both selections) 2 Selection 4: specifies lamp 1 located above terminals 10 (+) & 9 (-). Selection 5: specifies lamp 2 located above terminals 12 (+) & 11 (-). No lamp0 (position 5 only) Incandescent 4 3V 5 6V LED Amber Green 2VDC L F 6VDC M G 12VDC N H 24VDC P J 6 12V Red R S T V 7 Insert Color 8 Style 10 Legend 1 9 Style 1 DU 11 Legend Orientation 12 Legend 2 7 INSERT COLOR 1, 2 9 Painted Black - Laser Etch A Clear (Transparent) B White (Translucent) C Red (Translucent) D Amber (Translucent) E Green (Translucent) F Blue (Translucent) 1 SERIES LP L-Series Illumination Plug 3 ILLUMINATION LAMPS ILLUMINATION A 1 – B 1 – 2 – C 1 – 2 – E 1 & 2 Parallel H 1 & 2 Series 9 A A Y2 7 18V 8 24V 8, 9 STYLE (same coding for both selections) Z Not Painted (used with Insert Colors A-F) 5 Clear Laser Etch Background Color (used with Insert Color 9) A White Laser Etch Background Color (used with Insert Color 9) 10 LEGEND OVER LAMP 1 00 No legend __ Laser Etched or Body Legends For legend options, visit us at carlingtech.com 11 LEGEND ORIENTATION 0 No legend 1 Orientation 1 2 Orientation 2 3 Orientation 3 4 Orientation 4 4F MC MA MA MC 4F100 MA3MC MA1MC 12 LEGEND OVER LAMP 2 00 No legend __ Laser Etched or Body Legends For legend options, visit us at carlingtech.com 6 BRACKET COLOR 5 Black Notes: 1 To order separately, specify LPC and selection 7 code. Ex LPC-9 2 For LEDs, insert color must be clear, white or match color of LED. 3 For connector, specify part number LC2-01 (.187 tabs), LC3-01 (.250 tabs). 1.970[50.04] 1.020[25.91] POS 3 POS 2 POS 1 1.450[36.83] .280[7.11] www.carlingtech.com .250 X .032 [6.35] [.81] .855[21.72] 57 S-Series Rocker Switches - Introduction S-Series S-Series ROCKER SWITCHES S-Series rocker switches are designed for use in the enclosed cabs of today’s trucks, with special focus afforded to the vehicle operator. With features including abbreviated travel ½ throw actuation, ergonomic rockers, illumination in up to three detent switch positions, and a non-teasable snap action circuit, these switches provide the driver with easily recognizable and simple to operate controls. Designers will appreciate the 10A, 24VDC rating, space saving compact envelope, clean bezel-less design, integrated low insertion force connector and polarized switch base for quick installation. Most any illumination and switch circuitry is easily accommodated with the S-Series 10 terminal base. Product Highlights: Abbreviated travel ½ throw actuation Ergonomic rockers Recognizable and simple to operate controls Compact Design 58 www.carlingtech.com S-Series Rocker Switches - General Specifications Electrical Contact Rating 10A@ 24VDC Dielectric Strength 1500 Volts RMS between pole to pole Insulation Resistance 50 Megaohms Contact Resistance 10 milliohms max. @ 4VDC Contact Bounce <20 milliseconds Life 100,000 cycles maintained circuit,50,000 cycles momentary circuit at rated voltage and current gold plated Circuitry SP, DP 2 & 3 position, 1/2 or full throw Terminals .110 Tabs, Silver Plated Brass Mechanical Endurance 250,000 cycles minimum Physical Lighted LED - rated 100,000 hours 1/2 life (LED is internally ballasted for voltages to 24VDC.) BracketAcetal Base Nylon 66 GF RockerPolycarbonate Weight 25 gms max. Environmental Operating Temperature -40°C to +85°C Vibration Per IEC 68-2.6 test Fc and 68-2.47 Test Criteria - no noise or contact chatter below 10ms. Cold Test Per IEC 68-2-1 -40°C for 72 hours Test Criteria - pre & post test contact resistance. Dry Heat Test Criteria Per IEC 68-2-2 + 85°C for 72 hours Test Criteria - no loss of circuit during test, pre & post test contact resistance. Handling Shock Drop from height of 1 meter, 3 times, 4 sides. Test criteria - No loss of circuit during test, pre & post test contact resistance. Thermal Shock Per IEC 68-2-14, -40°C to +85°C. Test criteria - pre & post test contact resistance. Mounting Specifications Snap in Mount 40mm x 20mm keyed hole (see dimensional specifications for details.) Connector Amp/Tyco MCP 2.8 receptacle housing P/N 1418994-1 mates with Amp/Tyco MCP 2.8 flat type receptacle. Based on wire size, choose P/N below: 1-968880-1 1-968849-1 1-968851-1 20-24 awg wire 17-20 awg wire 13.5-17 awg wire Actuator Travel (Angular Displacement) 2 position (1/2 throw) 3 position (full throw) 12° 12° from center *Manufacturer reserves the right to change product specification without prior notice. www.carlingtech.com 59 S-Series Rocker Switches - Ordering Scheme S 18 A A R F 0 4 1 Series 2 Circuit 3 Rating 4 5 Illumination Lamp 1 6 Lamp 2 7 Lamp 3 8 Bracket Color ( ) - momentary SP - single pole uses terminals DP - double pole uses terminals 2 Connected Terminals OFF OFF 3 3 & 5, 4 & 6 ON (ON) 4, 5, 6, 7 OFF OFF 3&5 3&5 OFF 5&7 5&7 5 & 7, 4 & 6 5 & 7, 4 & 6 OFF NONE 1 NONE 1 NONE 1 NONE 1 ON ON (ON) (3 & 5, 4 & 6) (5 & 9, 4 & 6) 3 RATING 1 0.4VA 28VDC Resistive A 3 10.5mA 1.5A 28VDC, 5A 28V 50A Inrush Lamp Load B 4 3.5A 28VDC, 18A Inrush 3 C 10mA 10A 28VDC D 3 20mA 10A 14VDC 4 ILLUMINATION Lamps S NONE A 1 C 1 2 D 1 2 E 1&3 F 1 G 1&2 H 1&2 J 1, 2 & 3 K 1&2 60 9 Actuator Color 10 Legend Color 1 11 Legend Color 2 12 Legend Color 3 13 Legend 1 1 00 00 15 14 Legend 2 Legend Orientation 16 Legend 3 5,6,7 LAMP (SAME CODING FOR ALL 3 SELECTIONS) Selection 5: specifies lamp 1 located above terminals 1 (+) & 2 (-). Selection 6: specifies lamp 2 located in center of rocker. Selection 7: specifies lamp 3 located above terminals 9 (+) & 10 (-). 1 SERIES S 2 CIRCUIT Terminal Connections as viewed from bottom of switch: 1 - - 2 3, 5 & 7. 3 - - 4 3, 5, 7 & 4, 6, 8. 5--6 7--8 9 - - 10 Position: 1 SP DP 5 & 7, 6 & 8 16 26 ON 18 28 (ON) SPECIAL CIRCUITS 31 (6 & 8) 41 51 ON 42 52 (ON) 43 53 (ON) 44 54 ON 45 55 (ON) 46 56 NONE 47 57 NONE 75 (5 & 7, 3 & 6) 2 98 (5 & 7, 2 & 6) M Z Z Z 00 No lamp LED 12VDC 24VDC 0 Red A B Green H J 8 BRACKET COLOR 1 Black 4 Dark Carbon 9 ACTUATOR Standard Rocker, Laser Etched Black Titan Gray M N Dark Carbon R 10, 11, 12 LEGEND COLOR Z No Legend 1 Clear 13 LEGEND 1 5 00 No Legend ORIENTATION 1 14 LEGEND ORIENTATION 0 No legend 1 Orientation 1 2 Orientation 2 3 Orientation 3 4 Orientation 4 M22ZA8-13H-10000 M22ZA8-23H-10000 Illumination Type Lamp wired to Terminals INDEPENDENT – INDEPENDENT 1 (+) 2 (–) INDEPENDENT 1 (+) 2 (–) INDEPENDENT 9 (+) 2 (–) INDEPENDENT 1 (+) 2 (–) INDEPENDENT 9 (+) 10 (–) INDEPENDENT 1 (+) 2 (–) PARALLEL INDEPENDENT 1 (+) 10 (–) SNAP INDEPENDENT 1 (+) 10 (–) DEPENDENT 9 (+) 2 (–) INDEPENDENT 1 (+) 2 (–) DEPENDENT 9 (+) 10 (–) INDEPENDENT 1 (+) 2 (–) DEPENDENT 5 (+) 10 (–) INDEPENDENT 1 (+) 2 (–) INDEPENDENT 1 (+) 2 (–) INDEPENDENT 9 (+) 10 (–) 3.3K RESISTOR IN PARALLEL Orange Yellow C E D F ORIENTATION 4 ORIENTATION 2 ORIENTATION 3 15,16 LEGEND 2,3 6 00 No legend Notes: 1 Indicates 1/2 travel for actuator. 2 Snap-Action Contact Mechanism 3 Not available with circuit 98. 4 Available with circuit 98 only. 5 Located over T1-2. 6 Legend 2 located in center of rocker, Legend 3 located over T9-10. Legend 2 options are limited due to a very small marking area. Consult factory for specifics. www.carlingtech.com S-Series Rocker Switches - Dimensional Specifications Dimensional Specifications: in. [mm] MATES WITH TYCO/AMP MCP CONNECTOR 1418994-1 1.529 [38.84] .787 [19.99] .83 [21.1] .100 [2.54] PANEL KEY .048 [1.22] .032 [.81] 1.575 [40.01] R.016 [.41] (8 PLACES) R.079 [2.01] (4 PLACES) PANEL THICKNESS: 2.5±0.1mm PANEL OPENING CLEARANCE: ±5° SCALE 2.000 POS 0 POS 2 POS 1 R.833±.015 [21.15±0.38] SWING RADIUS .220 [5.59] 12° 12° .82 [20.8] .790 [20.07] 1.23 [31.2] 1.60 [40.6] www.carlingtech.com .79 [20.1] 61 N-Series Addressable Rocker Switches - Introduction N-Series N-Series ADDRESSABLE ROCKER SWITCHES The N-Series Addressable Switch combines the look and feel of a traditional electro-mechanical control coupled with a built in PCB and provides a flexible, cost effective alternative to a CAN/LIN based switch. The N-Series produces up to 144 individual switch IDs by using a resistive ladder circuit. Different switch IDs are achieved by changing the resistor values tied to individual loads, which can then be assigned to the specific functions that the switch is controlling. Each switch is connected to an ECU and the application software is written to recognize the switch IDs to determine which load is being controlled as well as the selected actuator position. As a result, the wiring harnesses are more simplified and specific loads can now be rearranged without the need for a costly and time consuming harness redesign, giving designers the ultimate in design flexibility. Resources: Download 3D CAD Files IGS STP Product Highlights: Cost effective alternative to CAN/LIN based switch Up to 144 individual switch IDs Simplified wiring harnesses Readdressable loads without harness redesign Available with paddle or rocker actuator 62 www.carlingtech.com N-Series Addressable Rocker Switches - General Specifications Electrical Environmental Contact Rating .4VA @ 28VDC (MAX) Dielectric Strength 1250 Volts RMS between pole to pole 3750 Volts RMS between live parts and accessible surfaces Insulation Resistance 50 Megaohms Contact Bounce 20 milliseconds max. Contacts gold plated Terminals Brass or copper/silver plate 3/16” (4.76mm) Quick Connect terminations standard. Mechanical Endurance 250,000 cycles minimum Physical 1.970 Lighted Incandescent - rated 10,000 hours LED - rated 100,000 hours 1/2 life (LED is internally ballasted for voltages to 24VDC) Seals Rocker, base & bracket are sealed. Base Nylon 66 GF rated to 85°C with a flammability rating of 94V0. Rocker and Paddle Nylon 66 Reinforced, rated to 105°C Laser Etched Rocker Polycarbonate rated at 100°C. Lens Polycarbonate rated at 100°C. Front snap-in. Connector Nylon 66 rated at 85°C. Polarized. Bracket Nylon Zytel Environmental Operating Temperature Vibration Salt Spray Humidity Mounting Specifications .867 [22.02] Actuator Travel (Angular Displacement) 2 position .260 [6.60] 3 position 26° 13° from center IP67 for above the panel components of the actual switch, representing an index of protection as applied to electrical equipment in accordance with IEC 529, BS 5490, DIN 400 50 & NFC 20 010. -40°C to +85°C Per SAE J1399 “electronic Tachometer Specification” for Class II truck and bus applications. Test Criteria: No change in resistance and no evidence of physical damage. Exposure to 95% water, 5% NCI fog solution at 95 degrees F according to ASTM B 117-90 “Standard Method of Salt Spray (fog) Testing”. Test Criteria: No visual evidence of corrosion or external physical damage. Samples were exposed to selected temperature profile, while maintaining 90% +- 5% relative humidity for 30 cycles. Test Criteria: No evidence of external physical deterioration. 1.734 [44.04] 1.020 [25.91] TEST CUT HOLE IN ACTUAL MATERIAL MOUNTING HOLE 2.265 [57.53] 3.055 [77.60] Panel Thickness Range Acceptable Panel Thickness .030 to .156 (.76mm to 3.96mm) Recommended: .030, .062, .093, .125 and .156 .250 X .031 [6.35 X .79] T3 GROUND PADDLE STYLE ACTUATOR Q.C. SELECTION GUIDE *Manufacturer reserves the right to change product specification without prior notice. [8.74] WIRE GAGE COMPANY SERIES PACKARD PART NO. AWG MM 2 PACKARD METRI-PACK 12084590 12052224 12015870 12 12 16-14 3.0 3.0 2.0-1.0 www.carlingtech.com 63 N-Series Addressable Rocker Switches - Ordering Scheme N 4 1 2 1 A N H 1 1 Series 2 Actuator 3 R1 Resistive ID 4 R2 Resistive ID 5 6 7 Resistor Illumination Lamp Constants 8 Lamp 1 1 2 46 10 Actuator 9 Bracket 11 Lens Style & Color Lamp 1 1 EK 14 15 Legend Actuator Orientation Lens Legend 1 SERIES N 7,8 LAMP (SAME CODING FOR BOTH SELECTIONS) Selection 7: above terminals 10 & 9; Selection 8: above terminals 12 & 11 No lamp 0 2 CIRCUIT 2 Terminal Orientation LED* Red AmberGreen 12VDC C NH * Consult factory for “daylight bright”, blue/green and white LED options. Typical current draw for LED is 20ma. ( ) - momentary 9 BRACKET COLOR 1 Standard Bracket Rockerguard at Lamp 1 Rockerguard at Lamp 2 2 Black 1 A E White 2 B F Gray 3 C G Red 4 D H 3 STANDARD 2 & 4 Connected Terminals 1 & 2 4 OnNONEON 5 (On)NONEON 6 OnONON 7 (On)ONOn 8 (On)ON(On) 3 R1 RESISTIVE IDENTIFICATION 1 1020 21300 31620 42000 52430 62940 73570 8 4320 A 5230 B 6340 C 7870 D 10000 4 R2 RESISTIVE IDENTIFICATION 1 1020 21300 31620 42000 52430 62940 73570 8 4320 A 5230 B 6340 C 7870 D 10000 Laser Etched 1 11 & 12 LENS STYLE AND COLOR Lens color for LEDs must be clear, white, or match color of LED. 0 - No ActuatorZ - No Lens Clear White Amber Green 1 - B G - 7 C H 3 - D J - 9 E K 5 A - - Red M N P R - Blue T Large Transparent U Large Translucent V Bar Transparent W Bar Translucent - Laser Etch background color 13 LEGEND ORIENTATION 00 No legend this location / no actuator For legend options & codes, see pages 54-65 of this catalog. Orientation 14 LEGEND ORIENTATION 1 0 No legend (used with codes 11-18 in selection 12) 1 Orientation 1 - vertical, lamp 1 on top 2 Orientation 2 - horizontal, lamp 1 on right 3 Orientation 3 - vertical, lamp 1 on bottom 4 Orientation 4 - vertical, lamp 1 on left AA 46 6 ILLUMINATION Lamp #1:above terminals 9 & 10 end of switch.; Lamp #2 above terminals 11 & 12 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only. Lamps Illumination Type Lamp wired to Terminals SNone A #1 Standard 10+ 12 #2 Standard 11+ 9B #1&2 Special Parallel 11+ 9C #1&2 Special Parallel 10+ 91 #1 Independent 10+ 92 #2 Independent 12+ 113 #1 Independent 10+ 9 #2 Independent 12+ 94 #1 Independent 10+ 9 #2 Independent 12+ 11- Red D M AA 46 3AA-146 Orientation 2 5 RESISTOR CONSTANTS (INDICATES SWITCH STATE) R3 R4R5 1 1300 10000 5320 2 825 66503830 10 ACTUATOR STYLE AND COLOR 1 Black White Gray Rocker A B C Paddle J N K Orientation 4 Position: 1 64 12 13 Lens Style Legend & Color Lamp 2 3AA-246 Orientation 3 15 ACTUATOR LENS LEGEND 00 No legend this location / no actuator For legend options & codes, see pages 54-65 of this catalog. Notes: 1 Custom colors are available. Consult factory. 2 Switch supplied with .187 tab terminals. www.carlingtech.com N-Series Addressable Rocker Switches - Dimensional Specifications Dimensional Specifications: in. [mm] N-SERIES N-SERIES SHOWN WITH LASER ETCHED ACTUATOR SHOWN WITH ROCKER GUARD 1.970 [50.04] 1.020 [25.91] .435 [10.16] .400 [10.16] 1.450 [36.83] .855 [21.72] N-SERIES N-SERIES SHOWN WITH LARGE LENS AND PADDLE ACTUATOR SHOWN WITH BARS LENS AND CONNECTOR 1.970 [50.04] 1.020 [25.91] .400 [10.16] .391 [7.62] 2.380 [60.45] N-SERIES N-SERIES LC2-01 BLACK .187 TAB CONNECTOR (PACKARD 480-SERIES) LH1 REMOVABLE HOLE PLUG WITH NON-SERRATED WINGS LH2 HOLE PLUG WITH SERRATED WINGS 1.970 [50.04] 1.020 [25.91] .500 [12.70] .920 [23.37] 1.325 [33.66] 1.710 [43.43] .300 [7.62] .790 [20.07] .855 [21.72] www.carlingtech.com 65 N-Series Addressable Rocker Switches - Circuit Diagrams & Lamp Circuit Diagrams Circuit Diagrams: Lamp Circuit Diagrams: SWITCH CIRCUIT DIAGRAMS SWITCH CIRCUIT DIAGRAMS T CIRCUIT SCHEMATIC CODE SCHEMATIC ILLUM. CODE 9 P1 R5 9 R3 P1 R4 P3 R1 R2 4 P3 2 R5 8 7 R3 INTERNAL CIRCUIT R4 R1 R2 BOARD (TYPICAL) 2 R5 P3 R3 P1 R4 5 2 R1 R2 P3 7 INTERNAL CIRCUIT BOARD (TYPICAL) R3 R4 R1 R2 1 A 2 P3 6 P2 R1 R2 R3P1 R4 P3 R5 2 9 R5 R4 2 8 7 R3 (-) 12 (-) 9 (-) 9 (+) 11 (+) 11 B B P2 R3 P1 R4 R5 P3 C 1 7 C 2 1 (+) 10 (+) 10 2 (-) 9 (-) 9 8 7 1 1 1 9 (+) 10 R1 R2 P3 2 1 R1 R2 9 P2 2 (-) 9 1 P1 2 8 7 9 P2 1 (+) 10(-) 12 (-) 9 P1 2 (+) 11 (+) 10 1 8 SCHEMATIC (-) 9(+) 11 A 9 R5 ILLUM. SCHEMATIC CODE (-) 9 8 7 9 P1 LAMP CIRCUIT DIAGRAMS LAMP CIRCUIT DIAGRAMS R5 R3 R4 (+) 10 R1 R2 (-) 11 2 7 8 2 (-) 11 8 7 2 2 2 2 (+) 12 9 P1 P2 8 P3 P2 R3P1 R4 P3 R1 R2 R5 R3 R5 R4 (-) 9 R1 R2 3 2 7 8 2 7 (-) 9 1 3 2 1 2 8 (+) 10 (+) 12 (+) 10 (+) 12 (-) 9 (-) 9(-) 11 (-) 11 1 4 (+) 10 66 (+) 12 9 4 2 1 (+) 12 (+) 10 2 (+) 12 www.carlingtech.com LD-Series Electronic Dimmer Control - Introduction LD-Series LD-Series ELECTRONIC DIMMER CONTROLS The LD-Series represents a dynamic breakthrough in dashboard technology, with its programmable circuitry, superior design, and unparalleled performance that affords seamless integration into most any dash panel. A variety of options, along with superior performance, functionality, and aesthetics assure compliance with the most stringent customer requirements. Key features include: robust design package with all components encased in switch housing, eliminating wire chafing, providing cost-savings as well; minimized electrical connections; IP67 sealing which prevents PCB degradation and eliminates short circuit potential. Superior heat dissipation is achieved with a heat sink mass which is over 50% larger than competitive products. Fully programmable circuitry lets the designer decide illumination levels and detent positions. EMC eliminates electrical “noise” and provides interference-free radio signals. Ease of assembly is accommodated with polarized integral connectors and an industry standard mounting hole. Product Highlights: 3 Choices for incremental dimming rates 12 or 24 Volts Laser Etched or Lens Illumination IP67 Sealing www.carlingtech.com 67 LD-Series Electronic Dimmer Control - General Specifications Electrical Contact Rating Dielectric Strength .4VA @ 24VDC (MAX) resistive 15 amps, 125VAC 10 amps, 250VAC 20 amps, 4-14VDC 15 amps, 15-28VDC 1250 Volts RMS between pole to pole 3750 Volts RMS between live parts and accessible surfaces Insulation Resistance 50 Megaohms Initial Contact Resistance 10 milliohms max. @ 4VDC Life 100,000 cycles maintained, 50,000 cycles momentary at rated voltage and current Contacts 90/10 silver-nickel, silver tin-oxide, gold Terminals Brass or copper/silver plate .230 (5.84 mm) Quick Connect terminations standard. Mechanical Endurance .250,000 cycles minimum Physical Lighted Incandescent - rated 10,000 hours LED - rated 100,000 hours 1/2 life (LED is internally ballasted for voltages to 24 VDC) Seals Rocker, base & bracket are sealed Base Nylon 66 GF rated to 85°C with a flammability rating of 94V0 Rocker Nylon 66 Reinforced, rated to 105°C (modular lens). Locking rocker, standard rocker & paddle. Laser etching with a polycarbonate actuator LockAcetal Lens Polycarbonate rated at 100°C Bracket Nylon Zytel 1.970 Connector Nylon 66 rated at 85°C. Polarized .260 [6.60] Actuator Travel (Angular Displacement) .390 [9.91] 1.020 [25.91] 2 position 3 positions Environmental IP67 for above panel components of the actual switch, representing an index of protection as applied to electrical equipment in accordance with IEC 529, BS 5490, DIN 400 50 & NFC 20 010. Corrosion Mixed Flowing Gas MFG Class III per ASTM B-827 & B-845, Method H, with 3 years exposure Operating Temperature -40°C to + 85°C Vibration 1 Per Mil-Std 202F, Method 204D Test Condition A 0.06 DA or 10G’s 10- 500 Hz. Tested with VCH connector. Test criteria - No loss of circuit during test and pre and post test contact resistance Vibration 2 24-50 Hz 0.40 DA 50-2000 ±10 G’s peak Results Horizontal Axis 3-5 G’s max. Random 24 Hz 0.06 PSD-Gsq/Hz 60 Hz 0.50 100 Hz 0.50 200 Hz 0.025 2000 Hz 0.025 No loss of circuit during test; <10µ chatter. Shock Per Mil-Std 202F, Method 213B, Test Condition K @ 30G’s. Tested with VCH connector. Test criteria - No loss of circuit during test, pre, and post test contact resistance Salt Spray Per Mil-Std 202F, Method 101D, Test Condition A, 48 Hrs. Thermal Shock Per Mil-Std 202F, Method 107F, Test Condition A, -55°C to 85°C. Test criteria - pre and post test contact resistance Moisture Resistance Per Mil-Std 202F, Method 106F, Test Criteria - pre and post test contact resistance Mounting Specifications .867 [22.02] 1.734 [44.04] 26° 13° from center TEST CUT HOLE IN ACTUAL MATERIAL MOUNTING HOLE .100 [2.54] 2.265 [57.53] 3.055 [77.60] Panel Thickness Range Acceptable Panel Thickness .030 to .156 (.76mm to 3.96mm) Recommended: .030, .062, .093, .125 and .156 .230 X .031 [5.84 X .79] T1 BAT T2 OUTPUT (LOAD) T3 GROUND PADDLE STYLE ACTUATOR *Manufacturer reserves the right to change product specification without prior notice. Q.C. SELECTION GUIDE 1.300 [33.02] .344 [8.74] 68 Environmental 1.570 [39.88] 1.340 [34.04] 1.060 [26.92] COMPANY SERIES PACKARD PART NO. PACKARD METRI-PACK 630 SERIES TIN PLATED BRASS 12084590 12052224 12015870 12015869 12020035 12052222 WIRE GAGE AWG MM 2 3.0 12 12 3.0 2.0-1.0 16-14 1.0-.80 20-18 22-18 (2 REQ'D) .80.-.50 (2 REQ'D) .50-.35 20-22 www.carlingtech.com LD-Series Electronic Dimmer Control - Ordering Scheme, Dimensional Specifications 4 5 6 7 Termination Illumination Illumination Bracket Color 3 Dimming Rate 3 A A FE 8 Actuator Style/ Color 9 Lens Color 9 & 10 LENS COLOR Z No Lens Clear White Amber 1 - B - 7 C 3 - D - 9 E 5A - 1 SERIES LD Electronic Dimmer Control 2 RATING 1 4A, 12 volts 2 10A, 12 volts A C 2A, 24 volts 5A, 24 volts 3 DIMMING RATE 1 30 - 100% 8 positions 5 10 - 100% 10 positions A 0 - 100% 11 positions 4 TERMINATION 1 .230 TABS (5.84 mm) 12 Legend Orientation 13 Legend 2 Green Red Blue Lens Style G MT Large Transparent H NU Large Translucent J PV Bar Transparent K RW Bar Translucent - - - Laser Etch 11 LEGEND #1 00 No legend FC Dim FE For legend options, visit us at carlingtech.com Bright ORIENTATION 1 12 LEGEND ORIENTATION 0 No legend 1 vertical (lamp 1 on top) 2 horizontal (lamp 1 on right) 3 vertical (lamp 1 on bottom) 5 & 6 ILLUMINATION No lamp S Red AmberGreen 12V LEDC N H 24V LEDD P J 1 FC 11 Legend 1 10 Lens Color LAMP 1 LAMP 2 LAMP 2 ORIENTATION 4 2 Rating LAMP 1 LAMP 2 LAMP 1 ORIENTATION 2 LD 3 5 1 C C 1 1 Series LAMP 2 7 BRACKET COLOR 1 1 Black LAMP 1 2 White 3 Gray 8 ACTUATOR STYLE / COLOR 1 Laser Etched Black White Gray Red Rocker 3 ABCD Paddle4 J K M N 45-4ZQ 45-3ZQ ORIENTATION 3 13 LEGEND #2 00 No legend FC Dim FE For legend options, visit us at carlingtech.com Bright Notes: 1 Custom colors are available. Consult factory. .867 [22.02] 1.970 1.734 [44.04] .260 [6.60] .390 [9.91] 1.020 [25.91] TEST CUT HOLE IN ACTUAL MATERIAL MOUNTING HOLE .100 [2.54] 2.265 [57.53] 3.055 [77.60] .230 X .031 [5.84 X .79] T1 BAT T2 OUTPUT (LOAD) T3 GROUND PADDLE STYLE ACTUATOR Q.C. SELECTION GUIDE 1.300 [33.02] .344 [8.74] 1.570 [39.88] 1.340 [34.04] www.carlingtech.com Panel Thickness Range Acceptable Panel Thickness .030 to .156 (.76mm to 3.96mm) Recommended: .030, .062, .093, .125 and .156 1.060 [26.92] COMPANY SERIES PACKARD PART NO. PACKARD METRI-PACK 630 SERIES TIN PLATED BRASS 12084590 12052224 12015870 12015869 12020035 12052222 WIRE GAGE AWG MM 2 3.0 12 12 3.0 2.0-1.0 16-14 1.0-.80 20-18 22-18 (2 REQ'D) .80.-.50 (2 REQ'D) .50-.35 20-22 69 LMR-Series Mirror Rotate Control - Introduction LMR-Series LMR-Series MIRROR ROTATE CONTROLS As an extension of the L-Series family of control products, the LMR-Series provides the means to control one or two mirrors and up to four separate motors from one easy to operate joy stick control. When used in conjunction with our dimmer control and wiper/washer control, Carling Technologies provides a solution to most any dashboard control need within the Transportation market. Product Highlights: Two or four axis Controls up to four separate motors Industry standard 44 x 22mm mounting hole Includes Delphi-Packard 8 pin connector 70 www.carlingtech.com LMR-Series Mirror Rotate Control - General Specifications, Ordering Scheme, Dimensional Specifications Actuator Termination Electrical Mechanism 4 axis joy stick style 1 9” wire leads with Delphi-Packard connector #12047886 1A 14V; .5A 28V 3 Sliding contacts in conjunction with a circuit board Sealing internal boot and potted wire leads protect critical components from dust and moisture LMR 1 Base Part Number 01 1 2 Color 3 Legend 1 BASE PART NUMBER: SERIES / RATING / FUNCTION / TERMINATION LMR 2 position (left, right), 4 axis (N,S,E,W) with wire leads 2 ACTUATOR /BRACKET COLOR 01Black 3 LEGEND 2 Z no legend 1 2 arrows symbol (left, right) 2 4 arrows symbol (front, back and left, right) Notes: 1 Compatible with Delphi-Packard #12045688. 2 All legends are imprinted in white. All product supplied with Mirror L & R legend on top of bracket and detent and directional legend on actuator. 3 Delphi-Packard is a registered trademark of Delphi-Packard Electrical Systems, Warren, Ohio. 1.965 [49.91] .867 [22.02] MIRROR R TEST CUT HOLE IN ACTUAL MATERIAL 1.734 [44.04] L 1.021 [25.94] WIRE 40 81A 82A 88A 88B 82B 81B 150 1.480 [37.59] PLUG MOUNTING HOLE .090 [2.29] L.H. MIRROR 88B M UP DOWN 89 COLOR ORANGE WHITE LT. BLUE YELLOW YEL-BLK ST. LT. BL-BLK ST. WHT-NLK ST. BLACK CAV I.D. A B C D E F G H R.H. MIRROR 89 88B M M M 89 RIGHT 81A 89 RIGHT 81B UP LEFT DOWN LEFT 1.280 [35.51] CONN P/N 12045688 9.060 [230.12] CONN P/N 12047886 88A 82A 81A LH 88B 82B 81B 40 150 RH 89 89 V/D L/R BATTERY SCHEMATIC GROUND *Manufacturer reserves the right to change product specification without prior notice. www.carlingtech.com 71 LW-Series Wiper/Washer Control - Introduction LW-Series LW-Series WIPER/WASHER CONTROLS The LW-Series Electronic Wiper Washer Control combines two switches into one self-contained unit allowing effortless control of both wash and wipe functions from a singular location. A variety of features and options including, Continuous low and high speed wiper positions, Six intermittent delay intervals ranging from 3-18 seconds, Push-to-wash button and an LED Night-light indicator combine to provide the flexibility to meet most any Cab design. The LW series is available for 14 or 28 volt operation and can be adapted to single or dual relay systems. Product Highlights: Controls both wash and wipe functions of vehicles 14 or 28 Volts Illuminated or Non-illuminated options Laser etched legends available 72 www.carlingtech.com LW-Series Wiper/Washer Control - General Specifications Electrical Contact Rating Terminals Protection Mechanical Mechanical Vibration Endurance 1 relay 8 amps, 14VDC 4 amps, 28VDC 2 relays 1 amps, 14VDC 1 amps, 28VDC .187 (7.4mm) Quick Connect terminations standard. Reverse polarity protection Over voltage protection Cold cranking protection according to SAE J1455, Sections. 4.11.1.1.1 and 4.11.1.2.1 Transient voltage protection which includes load dump and inductive switching according to SAE J1455, sec. 4.11.2.2 Electrostatic discharge protection according to SAE J1455 Sec. 4.11.2.2.5.1 (Discharge a 150 pf capacitor that has been charged to a potential of 15kV through 150 Ohm resistor.) Meets all other EMI/EMC requirements for class C trucks. Physical Characteristics Illumination LED, rated 100,000 hours 1/2 life CoverAcetate Washer Actuator Silicone Toggle Actuator Nylon 6/6 glass filled Bracket Nylon 6/6 Connector Nylon 6/6 rated 85°C polarized Washer Function Momentary Toggle Function Maintained Intermittent OperationMomentary Weight 44 grams Environmental Operating Temperature -25°C to +85°C Temperature Cycle According to SAE J1455, Sec. 4.1.3.1 (See Figure below) T 85C amb -40C 4 16 24 hour Sinusoidal Vibration: 10-55-10 Hz, 0.06” DA, one minute-cycle, three hours/axis Random Vibration: Three hours/axis, three mutually perpendicular axes with a test level 4G’s. Frequency Amplitude 5Hz 0.16 G2/Hz 100Hz 0.16 G2/Hz 500Hz -3dB/octave roll-off Tests were conducted according to SAE J1455, Sec 5.7 and Sec. 4.9.4. Shock: MIL-STD-202G Method 213B, Test Condition K, 30G’s, 11 ms. According to SAE J2349, March 97 for windshield washer switch for Trucks, Buses and Multipurpose Vehicles (20,000 cycle minimum). Thermal Shock According to SAE J1455, Sec. 4.1.3.2 (See Figure below) T 8 5 °C - 4 0 °C 0 2 4 6 8 10 12 14 16 18 hour Humidity According to SAE J1455, Sec. 4.2.3 (30 cycles for 8 hrs. with maximum temperature of 85°C and 95% relative humidity. Dust Bombardment According to SAE J1455, Sec. 4.7.3 (with dust concentration of 0.88gm/m for 24 hours.) Salt Spray MIL-STD-202G, Method 101D for 96 hours. *Manufacturer reserves the right to change product specification without prior notice. www.carlingtech.com 73 LW-Series Wiper/Washer Control - Ordering Scheme, Dimensional Specifications LW 1 A 1 1 Z 1 Series 4 3 Intermittent Wiper/ Washer Timing Timing 2 Rating 5 Lamp 1 4 5 6 7 Bracket Color 8 Rocker/ Paddle Color 10 11 Legend Legend 2 Orientation 9 Legend 1 8 ROCKER / PADDLE COLOR 1 Black 1 SERIES LW Wiper/Washer Control with six intermittent positions: low. high, wash/wipe 2 RATING 1 1 8A, 14VDC (1 relay) 2 4A, 28VDC (1 relay) 3 1A, 14VDC (1 relay) 1 1 AG 1 00 6 Lamp 2 9 LEGEND #1 00 No legend For legend options, visit us at carlingtech.com 1A, 14VDC (1 relay) 1A, 14VDC (2 relay) 1A, 28VDC (2 relay) 10 LEGEND ORIENTATION 0 No legend 1 Vertical (lamp 1 on top) 2 Horizontal (lamp 1 on right) 3 INTERMITTENT TIMING A 2-15 seconds 4 WIPER/WASHER TIMING 1 3 seconds 5 LAMP #1 (ABOVE WASH) Z No Lamp 1 Green LED 2 3 Red LED Amber LED 6 LAMP #2 (ABOVE WIPE) Z No Lamp 1 Green LED 2 3 Red LED Amber LED 11 LEGEND #2 00 No legend For legend options, visit us at carlingtech.com Notes: 1 Relay coil current is 1A max. Relay must have an arc suppression in parallel with the coil. Ref P/N LC2-01 for black wiper/washer connector housing. 7 BRACKET COLOR 1 Black 1.975 ±.010 [50.18 ±0.25] 0.060R MAX. 4 PLACES [1.52] 1.013 ±.010 [25.74' 0.25] 0.278 [7.06] LOW INTERMITTENT OFF 1.739 ±.008 HIGH [44.17 ±0.20] TEST CUT OPENING IN ACTUAL MATERIAL 1.082 [27.49] PRESS TO WASH .866 - .881 [22.00-22.38] SWITCH MOUNTING HOLE 3.492 [88.70] 2.522 [64.06] 1.724 [43.79] 1.700 [43.18] 0.855 [21.72] Principles of operation: From the OFF position, moving the toggle one step up puts the function into the intermittent slower mode (18 sec.). Moving the toggle another step up reduces the delay time by 3 sec for each of the next six steps. The seventh step up puts the motor into a continuous low-speed mode and the last step up puts the motor into the high-speed mode. Reversing the previous steps puts the motor finally into the stop/parking mode. During the OFF position, intermittent and low-speed modes, pressing the wash button activates the wash function. Wipe function starts after a two second delay from the onset of the washing and continues for three continuous wipes after the wash button is released. For convenience, the wash function is not active during the high-speed mode. The Wiper Control is designed to interface with single or dual relay systems for intermittent delay and the park function. The high speed is driven directly via a power transistor internal to the module. The coil of the relay is pulled down to ground during the intermittent, low-speed and high-speed modes respectively. (Contact Carling Technologies for wiring diagrams) 74 www.carlingtech.com CMB CMB-Series - Introduction CMB-Series THERMAL CIRCUIT PROTECTORS The CMB-Series is a compact, single pole, push-to-reset family of thermal circuit breakers designed to protect equipment. Utilizing simple, precision design with few moving parts, these breakers offer cost effective, extremely reliable circuit protection with high resistance against shock and vibration. Product Highlights: Ratings from 3-20A, 125, 250VAC, 32VDC 2500 VAC/1 minute 60°C Max Operating Temperature 2500A @ 32VDC Interrupting Capacity 100M ohms Insulation Resistance Voltage drop <0.25 V UL, CUL, CSA, TUV, CE UL1500/ISO8846 for ignition protection/marine Dimensional Specifications: in. [mm] www.carlingtech.com 75 CMB-Series - Ordering Scheme, Time Delay CMB 10 3 1 Series 2 Rating 1 SERIES CMB 2 RATING 03 3 amps 04 4 amps 05 5 amps 06 6 amps 07 7 amps 08 8 amps 11 C 3 N 3 Voltage 4 Mounting Hole 5 Bushing Type 6 Mounting Nut B 7 Indicator Plate 8 Button A /10 9 Terminal 10 Button Marking 3 VOLTAGE 3 125-250VAC/ 32 VDC 10 12 13 14 15 16 20 4 MOUNTING HOLE 11 1 M11 12 2 M12 00 3 Snap In Style 27 9 3/8” 27 UNS 28 12 3/8” 27 UNS (double flatted) 10 amps 12 amps 13 amps 14 amps 15 amps 16 amps 20 amps 5 BUSHING PLASTIC C 4 Type C D 4 Type D E 5 Type E G 8 Type G H 6 Type H K 13 Type K METAL Type J J 8 6 MOUNTING NUT 7 N None 1 Type 1 2 Type 2 11 3 Type 3 4 Type 4 5 Type 5 6 14 Type 6 7 9 Type 7 8 9 Type 8 NOTE: Type 5 is clear hex boot. Type 8 is black hex boot (available for bushings G, J & K only); Type 3 nut includes molded in “PRESS TO RESET” marking. Embossed (ALUMINUM) 7 INDICATOR PLATE 7 N None A Embossed Legend B Silver Printing on Black Silver Printing On Black .887 [22.5] .887 [22.5] .016 [.4] .016 [.4] All indicator plates are marked “Suppl. Prot. press to reset”. 8 BUTTON B Black 9 TERMINAL A Type A B Type B C Type C D Type D E Type E R F G H J Red W Notes: All dimensions are in.[mm]. Tolerance ±.005 [.127] unless otherwise specified. 1 Used with bushing C or D only. 9 Available with G, J or K bushing only. 2 Used with H bushing only. 10 Amp rating must match button marking 3 Used with bushing E only. (ex: 20 will be marked on the button of 4 Used with M11 mounting hole only. CMB-203-27G3N-W-A/20) 5 Used with mounting hole 00 only. 11 Includes molded in “PRESS TO RESET” 6 Used with M12 mounting hole only. marking. 7 All hardware available separately. 12 Available with K bushing only. Consult factory. 13 Available with mounting hole 28 only. 8 Available with mounting hole 27 only. 14 Thickness is 3.0 mm, .118 in. White Type F Type G Type H Type J F,G,H,J TERMINALS ARE 8-32 UNC 10 BUTTON MARKING (IF BLANK, NO MARKING.)10 03 04 3 amp 4 amp 05 06 5 amp 6 amp 07 08 Button Marking Orientation: 7 amp 8 amp 10 12 line 10 amp 12 amp 20 13 14 load 13 amp 14 amp 15 16 15 amp 16 amp 20 20 amp Time Delay Derating Factor -10 °C x 1.70 -5 °C x 1.60 0 °C x 1.50 5 °C x 1.40 10 °C x 1.30 15 °C x 1.20 20 °C x 1.10 25 °C x 1.00 Derating Factor 30 °C x 0.90 35 °C x 0.85 40 °C x 0.80 45 °C x 0.75 50 °C x 0.70 55 °C x 0.65 60 °C x 0.60 Overload 100% 150% 200% 300% 400% 500% 600% Trip Time No Trip Trip in 1 hr 4.0 ~ 40 sec. 0.9 ~ 8.0 sec. .42 ~ 5.0 sec. .25 ~ 3.0 sec. .01 ~ 1.8 sec. Notes: Breaker must hold 100% of rated current and must trip at 150% and above, within the time limits shown in curve. Trip times specified at 25° ambient with no preloading. 1 To adjust the breaker rating for ambient temperature multiply the breaker rating by the factor. (ex: 5 amp rating at 0°C: 5 x .67 = 3.3 amp. Select 3 amp rating.) *Manufacturer reserves the right to change product specification without prior notice. 76 www.carlingtech.com CLB CLB-Series - Introduction CLB-Series THERMAL CIRCUIT PROTECTORS The CLB-Series is a compact, single pole, push-to-reset family of thermal circuit breakers designed to protect equipment. Utilizing simple, precision design with few moving parts, these breakers offer cost effective, extremely reliable circuit protection with high resistance against shock and vibration. Product Highlights: Ratings from 3-60A, 125, 250VAC, 32VDC 2500 VAC/1 minute 60°C Max Operating Temperature 2500A @ 32VDC Interrupting Capacity 100M ohms Insulation Resistance Voltage drop <0.25 V UL, CUL, CSA, TUV, CE UL1500/ISO8846 for ignition protection/marine Dimensional Specifications: in. [mm] 3-40A Construction www.carlingtech.com 50 & 60A Construction 77 CLB-Series - Ordering Scheme, Time Delay CLB 10 3 1 Series 2 Rating 1 SERIES CLB 2 RATING 03 3 amps 04 4 amps 05 5 amps 06 6 amps 07 7 amps 08 8 amps 10 10 amps 12 12 amps 13 13 amps 12 C 3 N 3 Voltage 4 Mounting Hole 5 Bushing Type 6 Mounting Nut B 7 Indicator Plate A / 10 8 Button 9 Terminal 10 Button Marking 3 VOLTAGE 3 125-250VAC/ 32 VDC 15 15 amps 18 18 amps 20 20 amps 25 25 amps 30 30 amps 35 35 amps 40 40 amps 50 12 50 amps 60 12 60 amps 4 MOUNTING HOLE 11 1 M11 12 2 M12 00 3 Snap In Style 27 4 3/8” 27 UNS 5 BUSHING METAL Type A A 6 Type B B 6 8 Type J J PLASTIC Type C C 5 Type D D 7 8 Type E E 6 MOUNTING NUT 9 N None 1 Type 1 2 Type 2 3 Type 3 4 Type 4 5 Type 5 6 4, 14 Type 6 4 7 Type 7 8 4 Type 8 NOTE: Type 5 is clear hex boot. Type 8 is black hex boot (available for bushings E & J only); Type 3 nut includes molded in “PRESS TO RESET” marking. Embossed (ALUMINUM) 7 INDICATOR PLATE 9 N None A Embossed B Silver Printing on Black .887 [22.5] Silver Printing On Black .016 [.4] .887 [22.5] .016 [.4] All indicator plates are marked “Suppl. Prot. press to reset”. 8 BUTTON B Black 9 TERMINAL 10,11,15 A Type A F B Type B G C Type C H D Type D J E Type E R Red W Notes: All dimensions are in.[mm]. Tolerance ±.005 [.127] unless otherwise specified. 1 Used with bushing A or B only. 10 > 35 amp ratings must use solder joint to con 2 Used with bushing C only. nect wire to non-screw type terminals. 3 Used with bushing D only. 11 Terminals are .040 [1.0] thickness for rating> 35, 4 Used with bushing E & J only. & .315 [.8] thickness is for ratings < 35 amps. 5 Used with M12 mounting hole only. 12 Available only with 10-24 unc. screw terms. 6 Used with M11 mounting hole only. (select type F, G, H, J only.) UL, CUL only. 7 Used with mounting hole 00 only. 13 Amp rating must match button marking (ex: “20” 8 Used with 27 mounting hole only. will be marked on the button of the breaker) 9 All hardware available separately. 14 Thickness is 3.0 mm, .118 in. Consult factory. 15 Screw terminals are 8-32 UNC White Type F Type G Type H Type J 10 BUTTON MARKING (IF BLANK, NO MARKING.)13 Button Marking Orientation: 03 04 05 3 amp 4 amp 5 amp 06 07 08 6 amp 7 amp 8 amp 10 12 13 10 amp 12 amp 13 amp 15 18 20 line 20 load 15 amp 18 amp 20 amp 25 30 35 25 amp 30 amp 35 amp 40 50 60 40 amp 50 amp 60 amp Time Delay Derating Factor -10 °C x 1.70 -5 °C x 1.60 0 °C x 1.50 5 °C x 1.40 10 °C x 1.30 15 °C x 1.20 20 °C x 1.10 25 °C x 1.00 Derating Factor 30 °C x 0.90 35 °C x 0.85 40 °C x 0.80 45 °C x 0.75 50 °C x 0.70 55 °C x 0.65 60 °C x 0.60 Overload 100% 150% 200% 300% 400% 500% 600% Trip Time No Trip Trip in 1 hr 4.0 ~ 40 sec. 0.9 ~ 8.0 sec. .42 ~ 5.0 sec. .25 ~ 3.0 sec. .01 ~ 1.8 sec. Notes: Breaker must hold 100% of rated current and must trip at 150% and above, within the time limits shown in curve. Trip times specified at 25° ambient with no preloading. 1 To adjust the breaker rating for ambient temperature multiply the breaker rating by the factor. (ex: 5 amp rating at 0°C: 5 x .67 = 3.3 amp. Select 3 amp rating.) *Manufacturer reserves the right to change product specification without prior notice. 78 www.carlingtech.com CMBA/CLBA-Series - Auto Reset - Introduction CMBA/CLBA CMBA/CLBA-Series THERMAL CIRCUIT PROTECTORS The CMBA/CLBA-Series features automatic cycling and resetting thermal protection capabilities with the same performance as its traditional push-to-reset counterparts. Product Highlights: CMBA: 3-20A, 125, 250VAC, 32VDC CLBA: 3-40A, 125, 250VAC, 32VDC 2500 VAC/1 minute 60°C Max Operating Temperature 2500A @ 32VDC Interrupting Capacity 100M ohms Insulation Resistance Voltage drop <0.25 V UL, cUL, TUV Dimensional Specifications: in. [mm] CMBA Construction www.carlingtech.com CLBA Construction 79 CMBA/CLBA-Series - Auto-Reset - Ordering Scheme CMBA 1 Series 10 3 2 Rating 3 Voltage NN F N N 4 Mounting 5 Bushing 1 SERIES CMBA 6 Mounting Nut B 7 Indicator Plate A 8 Button Color 9 Terminal 10 Plug Marking 7 INDICATOR PLATE N N/A 2 RATING 2 03 3 amps 04 4 amps 05 5 amps 06 6 amps 07 7 amps 08 8 amps 10 12 13 15 18 20 8 BUTTON COLOR B Flush Black 10 amps 12 amps 13 amps 15 amps 18 amps 20 amps 9 TERMINAL A Type A 3 VOLTAGE 3 125-250VAC/ 32 VDC 4 MOUNTING NN Plug In 10 BUTTON MARKING 1 (IF BLANK, NO MARKING) Plug Marking Orientation: 5 BUSHING F None 03 04 05 06 6 MOUNTING NUT N N/A CLBA 1 Series 10 3 2 Rating 3 Voltage 07 08 10 12 7 amp 8 amp 10 amp 12 amp NN F N N 4 Mounting 5 Bushing 1 SERIES CLBA 2 RATING 2 03 3 amps 04 4 amps 05 5 amps 06 6 amps 07 7 amps 08 8 amps 10 10 amps 12 12 amps 3 amp 4 amp 5 amp 6 amp 6 Mounting Nut line 20 load 13 15 18 20 13 amp 15 amp 18 amp 20 amp B 7 Indicator Plate A 8 Button Color 9 Terminal 10 Plug Marking 7 INDICATOR PLATE N N/A 13 15 18 20 25 30 35 40 13 amps 15 amps 18 amps 20 amps 25 amps 30 amps 35 amps 40 amps 8 BUTTON COLOR B Flush Black 9 TERMINAL A Type A 3 VOLTAGE 3 125-250VAC/ 32 VDC 4 MOUNTING NN Plug In 5 BUSHING F None 10 BUTTON MARKING 1 (IF BLANK, NO MARKING) Plug Marking Orientation: 03 04 05 06 3 amp 4 amp 5 amp 6 amp 07 08 10 12 line 7 amp 8 amp 10 amp 12 amp 20 load 13 15 18 20 13 amp 15 amp 18 amp 20 amp 25 30 35 40 25 amp 30 amp 35 amp 40 amp 6 MOUNTING NUT N N/A Notes: 1 Amp rating must match plug marking. (ex: “20” will be marked on the plug of the breaker) No marking is standard. 2 See CMB/CLB graph for time delay information. *Manufacturer reserves the right to change product specification without prior notice. 80 www.carlingtech.com Custom Electronic Controls Cruise Control The cruise control assembly digitally communicates with the VECU to provide the proper signal when the operator presses a button on one of the controls. The left control includes acceleration and deceleration, while the right control panel includes the OFF/ON and Resume buttons. This product withstands temperatures from -40°C to +85°C, relative humidity up to 95%, condensation, direct sunlight and mechanical vibrations. The two controls are housed in an integrated assembly to minimize wiring. The expert design integrates seamlessly with the vehicle steering and wheel styling and is designed to meet customer-specific requirements for safety and ease of accurate assembly. Carling engineers will work with you and your vehicle design team to develop a customized cruise control solution for your specific needs. Horn Control The horn control is housed in an integrated assembly to minimize wiring and provides a flexible, yet durable actuator cover to endure exponential presses. It withstands temperatures from -40°C to +85°C, relative humidity up to 95%, condensation, direct sunlight and mechanical vibrations and was designed as a cost-effective alternative to traditional horn controls. This rugged control has an operating voltage of 12 to 24VDC. Carling engineers will work with you and your vehicle design team to develop a customized cruise control solution for your specific needs. Light Control Module The light control module is a multifunctional package that encompasses four critical controls within one easy-to-install, space saving unit. Controls include a high-current rotary switch, which controls parking lights and headlights; a push-pull feature on the switch to operate fog lights; an adjacent high-current thumb wheel dimmer switch to select the desired brightness for dash lighting; and an additional miniature rocker switch for auxiliary high-current lighting functions. The light control module is a compact, sleek, operator friendly, cost effective module. The rugged high-current switch design allows high-current loads to be handled without the need to include costly relays in the switch circuit. The snap-in design and integrated keyed connector make installation easy, and the compact design uses little valuable dashboard space. HVAC Motor Controller The HVAC motor controller efficiently controls heating and ventilation and interfaces with the vehicle’s VECU to adjust the speed of the HVAC blower motor. There are two connections in the controller, one to the load through the harness and another to the VECU. The signal from the VECU controls the motor speed and creates a soft start that will suppress any inrush during the motor’s start up. The HVAC motor controller operates at 12 or 24VDC and drives DC motors up to 30A. It provides overvoltage protection, up to 100V for two minutes, meeting automotive requirements for EMC, vibration and shock. These features help extend the life of the HVAC unit and prevent the nuisance blowing of fuses or circuit breakers. The HVAC controller is sealed to IP68, providing protection from the extreme environmental conditions experienced by the blower housing. The HVAC Motor Controller is compact and uses fewer components and connections than traditional motor control devices. www.carlingtech.com 81 Custom Operator Control Modules Keypads Operator control modules utilize industry standard SAE J1939 CAN and NMEA communication protocols. By incorporating a single connector to the CAN bus via a communications cable, wire harnesses are greatly simplified, saving space, weight and cost. Through the use of embedded software, these modules are configurable to your specific load requirements and diagnostic needs. The compact keypad, available in standard or custom silicone designs, is the perfect interface for the many HMI functions that it controls. These sleek control pads provide a distinctive tactile feel for the operator, while incorporating wear-resistant lasered graphics for long life. Operator Control Modules are available with many features including multiple function lighting, CAN data-controlled variable dimming, and backlighting Solid State Power Control Module Features: • 12 Channel/24 VDC electronic circuit breakers • J1939 Communication • Software Selectable Trip Characteristics • Dimming and Soft Start PWM • Reverse Polarity Protection • Up to 15 Amps per channel • Rated for 80 Amps Continuous Operation • Load Shedding Capability VOCM Multiplexed V-Series rocker modules use industry standard SAE J1939, LIN, and NMEA communications protocols. The rocker module provides the look and feel of a traditional electromechanical switch with the connection benefits of a multiplexed module. Using one cut-out for six switch functions, the multiplexed V-Series rocker modules save assembly time, and greatly simplify wiring and harness requirements, providing a high-tech yet costeffective solution. 82 www.carlingtech.com Standard Legend Imprinting Notes: 1 Negative legends not available on L, LD, LW, and N-Series. 2 Many symbols are SAE (J1362), ANSI and ISO approved symbols. Consult factory for custom symbols/icons. 3 Use “body” legend codes for laser etched image identification. www.carlingtech.com 83 Standard Legend Imprinting Notes: 1 Negative legends not available on L, LD, LW, and N-Series. 2 Many symbols are SAE (J1362), ANSI and ISO approved symbols. Consult factory for custom symbols/icons. 3 Use “body” legend codes for laser etched image identification. 84 www.carlingtech.com Standard Legend Imprinting Notes: 1 Negative legends not available on L, LD, LW, and N-Series. 2 Many symbols are SAE (J1362), ANSI and ISO approved symbols. Consult factory for custom symbols/icons. 3 Use “body” legend codes for laser etched image identification. www.carlingtech.com 85 Standard Legend Imprinting Notes: 1 Negative legends not available on L, LD, LW, and N-Series. 2 Many symbols are SAE (J1362), ANSI and ISO approved symbols. Consult factory for custom symbols/icons. 3 Use “body” legend codes for laser etched image identification. 86 www.carlingtech.com Standard Legend Imprinting Notes: 1 Negative legends not available on L, LD, LW, and N-Series. 2 Many symbols are SAE (J1362), ANSI and ISO approved symbols. Consult factory for custom symbols/icons. 3 Use “body” legend codes for laser etched image identification. www.carlingtech.com 87 Standard Legend Imprinting Notes: 1 Negative legends not available on L, LD, LW, and N-Series. 2 Many symbols are SAE (J1362), ANSI and ISO approved symbols. Consult factory for custom symbols/icons. 3 Use “body” legend codes for laser etched image identification. 88 www.carlingtech.com Standard Legend Imprinting Notes: 1 Negative legends not available on L, LD, LW, and N-Series. 2 Many symbols are SAE (J1362), ANSI and ISO approved symbols. Consult factory for custom symbols/icons. 3 Use “body” legend codes for laser etched image identification. www.carlingtech.com 89 Standard Legend Imprinting Notes: 1 Negative legends not available on L, LD, LW, and N-Series. 2 Many symbols are SAE (J1362), ANSI and ISO approved symbols. Consult factory for custom symbols/icons. 3 Use “body” legend codes for laser etched image identification. 90 www.carlingtech.com Standard Legend Imprinting Notes: 1 Negative legends not available on L, LD, LW, and N-Series. 2 Many symbols are SAE (J1362), ANSI and ISO approved symbols. Consult factory for custom symbols/icons. 3 Use “body” legend codes for laser etched image identification. www.carlingtech.com 91 Standard Legend Imprinting Notes: 1 Negative legends not available on L, LD, LW, and N-Series. 2 Many symbols are SAE (J1362), ANSI and ISO approved symbols. Consult factory for custom symbols/icons. 3 Use “body” legend codes for laser etched image identification. 92 www.carlingtech.com Standard Legend Imprinting Notes: 1 Negative legends not available on L, LD, LW, and N-Series. 2 Many symbols are SAE (J1362), ANSI and ISO approved symbols. Consult factory for custom symbols/icons. 3 Use “body” legend codes for laser etched image identification. www.carlingtech.com 93 Standard Legend Imprinting Notes: 1 Negative legends not available on L, LD, LW, and N-Series. 2 Many symbols are SAE (J1362), ANSI and ISO approved symbols. Consult factory for custom symbols/icons. 3 Use “body” legend codes for laser etched image identification. 94 www.carlingtech.com Carling Technologies Catalogs There are several catalogs available featuring complete details on all Carling Technologies products. Below is a list of useful information such as catalogs, brochures and videos. Please visit our website at carlingtech.com or scan the QR codes below for complete details. www.carlingtech.com Watch Company Profile Video Switches & Controls Hydraulic-Magnetic SWITCHES & CONTROLS Rocker, Toggle, Pushbutton & Rotary CATALOG Circuit Protection CATALOG catalog catalog Complete line and ordering details for Switches & Control products including Rocker, Toggle, Pushbutton, and Rotary style switches. Complete line and ordering details for all hydraulic-magnetic circuit breakers. Thermal GFCI / ELCI GFCI / ELCI THERMAL Circuit Protection Circuit Protection CATALOG catalog Complete line and ordering details for all thermal circuit breakers. www.carlingtech.com CATALOG catalog Complete line and ordering details for all GFCIs/ELCIs. 95 Carling Technologies Catalogs Marine On-Off Highway MARINE ON/OFF HIGHWAY Switches, Circuit Protection & ELCI/GFCIs Switches & Controls catalog brochure catalog brochure Complete line of ELCIs, thermal and hydraulic-magnetic circuit breakers specific for marine applications. Complete line of switches, controls and custom solutions specific for on-off highway applications. Renewable Energy Military MILITARY RENEWABLE ENERGY Circuit Breakers & Disconnects COTS Switches & Circuit Breakers catalog brochure catalog brochure Complete line of circuit breakers and disconnect products specific for renewable energy applications. Complete line of COTS (Commercial-Off-The-Shelf) switches and circuit breakers specific for military applications. Telecom/Datacom Industrial Automation TELECOM/DATACOM INDUSTRIAL AUTOMATION AND CONTROLS Circuit Protection Circuit Protection & Switches catalog brochure Complete line of hydraulic-magnetic circuit breakers specific for telecom/datacom applications. 96 brochure Complete line of switches and circuit breakers specific for industrial automation & controls applications. www.carlingtech.com Reps & Contact Authorized Sales Representatives Click on the group name on the map below to find your local representative or visit www.carlingtech.com/findarep. « « Matera W. Canada Matera E. Canada MIDWEST DM Michigan TEMCO Northwest Alaska, Hawaii « NORTHERN Hanna Lind Ltd. Melody Emery Sierra Bridge Marketing Omega Limited Dy-tronix Inc. LD. Allen Norris DM Assoc East Pacent DM Assoc TSI North TSI WEST Signal Enterprises Luscombe Engineering Pinnacle Marketing Matrix DM Mexico South America Mexico « « Sunbelt Components SOUTHEAST ProRep Solutions LATIN AMERICA Americas Europe Middle East Africa Asia-Pacific Oceania About Carling Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide, Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! To learn more about Carling please visit www.carlingtech.com/company-profile. To view all of Carling’s environmental, quality, health & safety certifications please visit www.carlingtech.com/environmental-certifications www.carlingtech.com 97 Worlwide Headquarters Asia-Pacific Headquarters 60 Johnson Avenue, Plainville, CT 06062 Tel: (860) 793-9281 Fax: (860) 793-9231 Email: [email protected] Web: www.carlingtech.com Kowloon, Hong Kong Tel: Int + 852-2737-2277 Fax: Int + 852-2736-9332 Email: [email protected] Carling Technologies, Inc. Northern Region Sales Office Carling Technologies, Asia-Pacific Ltd. Shenzhen, China [email protected] Europe/Middle East/ Africa Headquarters Carling Technologies Ltd. 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Tel: Int + 44 1392-364422 Fax: Int + 44 1392-364477 Email: [email protected] [email protected] Shanghai, China [email protected] Pune, India Germany [email protected] Kaohsiung, Taiwan France [email protected] Yokohama, Japan Southeast Region Sales Office Midwest Region Sales Office West Region Sales Office Latin America Sales Office [email protected] O N/OFF-HIGHWAY- C_05_2016 [email protected] [email protected] [email protected] [email protected] [email protected] [email protected]