LU500 Data Sheet

LU500
500W Single Output
LED Series
Features
4” X 7.25” X 2.2” Package
Up to 500W w/air
Universal Input 90 to 305Vac
Active current share
Class I Input
Approved to EN60950 2nd Edition
93% Efficiency @ 230V Input, 92% @ 115V Input
3 Year Warranty
Description
A superior performance 500 Watt AC to DC power supply designed for LED applications. Highly efficient, LU500 product
family has active current share for redundant applications. All models are CE marked to low voltage directive and
nd
approved to EN60950 2 edition.
Model Selection
Model
Number
Ripple &
1
Total
Total
Regulation
OVP
Threshold
1.5%
±2%
13.8.± 1.0V
20.8A
1%
±2%
27.6 ± 1.0V
10.4A
1%
±2%
55.5 ± 2.0V
Volts
w/200LFM air
LU500S12T
12V
34A
LU500S24T
24V
LU500S48T 3
48V
Noise
2
Notes:
1)Input Connector: “T” = Terminal Block and replace with “E” = 3pin Molex
2) Measured with noise probe directly across output terminals with 0.1µF ceramic and 10µF low ESR capacitors.
For main output load of less than 5%, total noise & ripple will increase to 2%.
3) Consult the factory for availability
General Specifications
AC Input
Input Current
Inrush Current
Input Fuses
www.slpower.com
90-305Vac, 47-63Hz
DC input127–380Vdc (External fuse required.
Not Safety Approved)
Power supply is protected against brown out
condition
Turn On Time
<500mS @115Vac
115Vac: 5A, 230Vac: 2.5A, 277Vac: 2.1A
Hold-up Time
16 mS minimum at full load & 100 Vac input.
Measured from 100% to 90% of output voltage.
277Vac, cold start: will not exceed 70A
Power Factor
Correction
Meets EN61000-3-2, Class A, C, and D
F1, T10A, 500Vac, provided on all models
Overload
Protection
Main Output
LU500 REV 10.0, 10-07-15
120% to 140% of current rating, Hiccup Mode
1
LU500
500W Single Output
LED Series
Leakage
Current
Efficiency
Output Power
Transient
Response
Earth: <350µA @ 277Vac, 60Hz, NC;
12V: Typ 90% at Full Load, 115Vac & 92% at
Full Load, 230Vac
Other Outputs: 92% typical at 115Vac, 93%
typical at 230Vac
Up To 500W continuous with 200 LFM airflow,
50°C ambient
500 uS typical for return to within 0.5% of
nominal, 50% load step from 5% to 100%.
∆i/∆t: <0.2A/µS.
Maximum Voltage Deviation = 3%
Short Circuit
Protection
Self-recovering
Overvoltage
Protection
Hiccup Mode, Self-recovering see models chart
for trip ranges.
Overtemperature
Protection
Provided, self-recovering
Automatic power shutdown at TC 135°C/115°C
Switching
Frequency
PFC: Variable, 50-500kHz
Main Converter: Variable 40-180 kHz, 65Khz
typical
Input-Output: 3000Vac
Input-Ground: 1500Vac
Output-Ground: 500Vac
Ripple and Noise
Main Output
See models chart
Isolation
Output Voltage
See models chart
Operating
Temperature
-10°C to +70°C (Derate output power linearly by
2.5% /˚C above 50°C to 50% at 70°C)
+/-5% from nominal
Units must be set within 0.1% of each other for
Current share configuration
Storage
Temperature
-40°C to +85°C
Voltage
Adjustability
Minimum Load
Total Regulation
Vibration
Dimensions
Weight
Ordering Option
Altitude
Not required
Relative
Humidity
Main Output: ±2%.
Operating: 0.003g²/Hz, 1.5grms overall, 3 axes,
1 hr/axis
Operating: 0.026g²/Hz, 5.0grms overall, 3 axes,
10 min/axis
4”X7.25”X2.2”
101.60X184.15X55.88mm
Shock
Safety Standards
MTBF
1.5 lbs (0.68kg)
Audible Noise
Please see model Selection
Operating: 3000m
Non-operating: -150 to 12,000m
5% to 95%, non-condensing
Operating: Half-sine, 40gpk, 8ms, 3 axes, 6
shocks total
EN/CSA/UL/EN60950 2nd Edition
Over 500,000 hours, 115Vac input
N/A
Unless is stated otherwise, all specification are based on 25°C ambient
Auxiliary Signals
Current Sharing
Active single wire current share for up to 2 units.
Please consult Application notes for proper
wiring for up to 2 units in parallel
EMI/EMC Compliance
Conducted Emissions
EN55015 Class B, FCC Part 15, Subpart B, Class B
Radiated Emissions
EN55011/15 Class A; FCC Part 15, Subpart A, Class A
Static Discharge Immunity
EN61000-4-2, Criteria A, 8kV Contact Discharge, 15kV air discharge
Radiated RF Immunity
EN61000-4-3, 10V/M Criteria A
EFT/Burst Immunity
EN61000-4-4, 2kV/5kHz
www.slpower.com
LU500 REV 10.0, 10-07-15
2
LU500
500W Single Output
LED Series
EN61000-4-5, 1kV differential, 2kV common-mode
Line Surge Immunity
Conducted RF Immunity
EN61000-4-6, 3Vrms
Power Frequency Magnetic Field Immunity
EN61000-4-8, 3A/m
Line Harmonic Emissions
EN61000-3-2, Class A,C, and D
Flicker Test
EN61000-3-3, Complies
Isolation Specifications
Parameter
Conditions/Description
Min
Nom
Max
Units
Electric Strength Test Voltage
Input/Ground
Input/Output
Output/Ground
1500
3000
500
-
-
Vac
Vac
Vac
Mechanical Drawings
www.slpower.com
LU500 REV 10.0, 10-07-15
3