GPFC110 Instructions

SL Power Electronics, Corp.
6050 King Dr., Unit A
Ventura, CA 93003 + 805-486-4565
GPFC110 SERIES
INSTALLATION INSTRUCTIONS
MODEL NUMBERS: GPFC110-X-C G where X represents the output voltage which may be any number from 5 thru 48.
Suffix ā€“C indicates optional cover is provided. May be followed by an optional ā€œGā€ which represents compliance with
RoHS.
RATINGS:
Input: 100-240 V ac, 2.3 A, 50/60 Hz
Output: Ratings for output voltages 5 thru 11
75 W maximum, with a minimum of 100 LFM, with or
without cover.
55 W maximum, no airflow, without cover.
45 W maximum, no airflow, with cover.
Notes:
Ratings for output voltages 12 thru 48
110 W maximum, with a minimum of 100 LFM, with or
without cover.
80 W maximum, no airflow, without cover.
75 W maximum, no airflow, with cover.
1. Maximum ambient temperature for rated output power is 50 °C.
2. Fan Output (J3): Obtained from output voltage through a series resistor. Use 5 V fan for 5 V output. Use 12 V fan for 12
and 15 V outputs. Use 24 V fan for 24 and 28 V outputs. Use 48 V fan for 48 V output.
3. Maximum Operating Relative Humidity 96 %, no condensation.
4. Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of power.
SAFETY DECLARATION: Condor DC Power Supplies, Inc. declares under our sole responsibility that all
models listed above are in conformity with the applicable requirements of EN 60950-1 following the
provisions of the Low Voltage Directive 73/23/EEC. All models are Certified to be in compliance with the
applicable requirements of EN/IEC/UL 60950-1 1st Ed. and CAN/CSA 22.2 No. 60950-1-03. They are certified for Pollution
Degree 2 environment and Class I TN-S power systems. All DC outputs are SELV under normal and single fault conditions.
TEMPERATURES: The maximum operating temperatures of components used in this supply must not be exceeded
after installation. The orientation of the supply, output power, ambient temperature and the availability, amount, direction
and/or restriction of natural airflow influences the temperatures of these components. Keeping the temperature of the core of
T2 below 110 °C will usually be sufficient to meet all other temperature requirements.
GROUNDING: The Functional Earth (Ground) terminal J1-1 and/or chassis must be bonded to Protective Earth in the end
application. Using J1-1 for the end product protective earthing terminal is not recommended. A separate dedicated protective
earthing point should be used.
SPACINGS: The required creepage and clearance distances from primary circuits to
ground and secondary circuits must be maintained after installation to preserve the
intended safety.
EXPLANATION OF SYMBOLS
Alternating Current
Direct Current
WARNING! RISK OF FIRE! A blown internal fuse is an indication of
Attention, Consult
Accompanying Documents
catastrophic failure of circuit component(s). Repair must be performed by Condor
authorized personnel.
Attention, Dangerous Voltages
WARNING! SHOCK HAZARD! Dangerous voltages are present on some
components and printed wiring traces.
CONNECTIONS
J1 Pin
AC Input
1
3
Ground
Neutral
5
Line
J2 Pin
1,2,3
4
5
6,7,8
9
DC Output
+ Output
+ Sense
-Sense
Return
Power Fail
J3 Pin
1
2
Functional Earth (Ground)
MATING CONNECTORS
Fan Output
Fan Return
+ Fan
J1
J2
J3
Amp Housing 640250-5 Contact 770476-1
Amp Housing 640250-9 Contact 770476-1
Amp MTA-100 Receptacle
CAUTION: Do not exceed 5 A per pin on J2.
SL Power Electronics, Corp. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried
out by other than authorized agents of SL Power Electronics, Corp., or b) the installation of the supply is not in accordance with these installation instructions and the
applicable UL, CSA, or EN/IEC safety standards.
41-34432-0001 Rev F 06/05/06