SL Power Electronics, Corp. 6050 King Dr., Unit A Ventura, CA 93003 + 805-486-4565 GPFC110 SERIES INSTALLATION INSTRUCTIONS MODEL NUMBERS: GPFC110-X-C G where X represents the output voltage which may be any number from 5 thru 48. Suffix āC indicates optional cover is provided. May be followed by an optional āGā which represents compliance with RoHS. RATINGS: Input: 100-240 V ac, 2.3 A, 50/60 Hz Output: Ratings for output voltages 5 thru 11 75 W maximum, with a minimum of 100 LFM, with or without cover. 55 W maximum, no airflow, without cover. 45 W maximum, no airflow, with cover. Notes: Ratings for output voltages 12 thru 48 110 W maximum, with a minimum of 100 LFM, with or without cover. 80 W maximum, no airflow, without cover. 75 W maximum, no airflow, with cover. 1. Maximum ambient temperature for rated output power is 50 °C. 2. Fan Output (J3): Obtained from output voltage through a series resistor. Use 5 V fan for 5 V output. Use 12 V fan for 12 and 15 V outputs. Use 24 V fan for 24 and 28 V outputs. Use 48 V fan for 48 V output. 3. Maximum Operating Relative Humidity 96 %, no condensation. 4. Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of power. SAFETY DECLARATION: Condor DC Power Supplies, Inc. declares under our sole responsibility that all models listed above are in conformity with the applicable requirements of EN 60950-1 following the provisions of the Low Voltage Directive 73/23/EEC. All models are Certified to be in compliance with the applicable requirements of EN/IEC/UL 60950-1 1st Ed. and CAN/CSA 22.2 No. 60950-1-03. They are certified for Pollution Degree 2 environment and Class I TN-S power systems. All DC outputs are SELV under normal and single fault conditions. TEMPERATURES: The maximum operating temperatures of components used in this supply must not be exceeded after installation. The orientation of the supply, output power, ambient temperature and the availability, amount, direction and/or restriction of natural airflow influences the temperatures of these components. Keeping the temperature of the core of T2 below 110 °C will usually be sufficient to meet all other temperature requirements. GROUNDING: The Functional Earth (Ground) terminal J1-1 and/or chassis must be bonded to Protective Earth in the end application. Using J1-1 for the end product protective earthing terminal is not recommended. A separate dedicated protective earthing point should be used. SPACINGS: The required creepage and clearance distances from primary circuits to ground and secondary circuits must be maintained after installation to preserve the intended safety. EXPLANATION OF SYMBOLS Alternating Current Direct Current WARNING! RISK OF FIRE! A blown internal fuse is an indication of Attention, Consult Accompanying Documents catastrophic failure of circuit component(s). Repair must be performed by Condor authorized personnel. Attention, Dangerous Voltages WARNING! SHOCK HAZARD! Dangerous voltages are present on some components and printed wiring traces. CONNECTIONS J1 Pin AC Input 1 3 Ground Neutral 5 Line J2 Pin 1,2,3 4 5 6,7,8 9 DC Output + Output + Sense -Sense Return Power Fail J3 Pin 1 2 Functional Earth (Ground) MATING CONNECTORS Fan Output Fan Return + Fan J1 J2 J3 Amp Housing 640250-5 Contact 770476-1 Amp Housing 640250-9 Contact 770476-1 Amp MTA-100 Receptacle CAUTION: Do not exceed 5 A per pin on J2. SL Power Electronics, Corp. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other than authorized agents of SL Power Electronics, Corp., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA, or EN/IEC safety standards. 41-34432-0001 Rev F 06/05/06