CUI VSCP-1K5-36

1/4
VSCP-1K5 Series Switching Power Supply
Rev. 7-2007
Features
·Current Sharing capability
·0.98 Typical Power Factor
·Programmable Output Voltage
·Universal AC Input
·Short Circuit, overload, over voltage,
over temperature protected
·Forced air cooling by built-in DC fan
·Power Failure Signal
·Built-in Remote Sense
·Built-in Remote Inhibit
·2 year warranty
Model
VSCP-1K5-09
VSCP-1K5-12
VSCP-1K5-15
VSCP-1K5-18
VSCP-1K5-24
VSCP-1K5-36
VSCP-1K5-48
VSCP-1K5-60
Output 1
9 V
12 V
15 V
18 V
24 V
36 V
48 V
60 V
Output Current
Minimum Maximum 2
0A
88/166 A
0A
66/125 A
0A
53/100 A
0A
44/83.3 A
0A
33/62 A
0A
22/41.6 A
0A
16/31 A
0A
13/25 A
Max. Power
1500 W
1500 W
1500 W
1500 W
1500 W
1500 W
1500 W
1500 W
Ripple & Noise 3
Regulation
(Vpp)
Efficiency
<1%
1%
83%
<1%
1%
84%
<1%
1%
85%
<1%
1%
85%
<1%
1%
88%
<1%
1%
88%
<1%
1%
89%
<1%
1%
90%
Notes:
1 Output voltage is measured at output power connector.
2 Maximum current is measured at 100-120V input / 200-240V input
3 Ripple and noise is measured from 10 KHz to 20 MHz at output terminals with 0.1 µF ceramic capacitor and
a 22 µF electrolytic capacitor in parallel.
V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062
www.v-infinity.com
1-866-372-1258
2/4
VSCP-1K5 Series Switching Power Supply
Rev. 7-2007
Input
Parameter
Input frequency
Input voltage
Input Current
Inrush Current
Conditions/Description
100~120 / 200-240 VAC (see derating curve)
(130~185 / 260~370 VDC) (see derating curve)
Min
47
100
130
9.0
Nom
Max
63
240
370
230
120
Units
Hz
VAC
VDC
A
A
Min
Nom
25
Max
12
100
Units
mS
%
-7.5
+7.5
%
Peak measured at 230 VAC at full load, cold start
Output
Parameter
Hold-up time
Programming
Conditions/Description
Full load at 230 VAC
Output voltage programmable through external
0~5V control voltage on VCI. Control voltage can
also be obtained from VCO via a 470 KOhm pot.
See application diagrams.
Voltage adjustability Typical adjustment by potentiometer
25%-100% Adjustment by 1-5Vdc external control
Temp. coefficient
±0.04
%/ºC
Protection Circuit
Parameter
Overload
Over-voltage
Conditions/Description
Min
Nom
Max
Units
Current limiting 3 times (1.5”, 3.0”, 5.0”), then intelligent auto recovery before shutdown
110
135
%
General and Safety
Parameter
Operating temp.
Operating humid.
Storage temp.
Storage humid
Vibration
EMC
Safety regulation
Leakage current
Cooling
Conditions/Description
Min
Nom
0
20%
-20
10
Period of 60 min. for each axis
10
EN55022, EN610000-4-2,3,4,5,6,8,11, EN61000-3-2-3 ENV50204
UL/cUL 1950, TUV EN60950
at 240 VAC
Power rating and temperature controlled fan
Max
50
90%
85
95
200
Units
ºC
RH
ºC
%
Hz
<7.0
mA
Max
Units
kg
mm
Mechanical
Parameter
Weight
Enclosure
Conditions/Description
Min
Nom
4.5
290(L) x 120(W) x 132.5(H)
Logic Connector
Parameter
Pin Assignments:
Conditions/Description
1. INH - Remote On-Off / Remote Inhibit
2. GND - Return / Output Ground
3. PAR - Current Sharing / Parallel function
4. FAL - Failure
5. VCO - Reference output voltage (5-10 VDC) to be used for output programming
6. VCI - Command input voltage for output programming
7. VS(-) - Remote Sense (-)
8. VS(+) - Remote Sense (+)
V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062
www.v-infinity.com
1-866-372-1258
3/4
VSCP-1K5 Series Switching Power Supply
Rev. 7-2007
Logic Connections
V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062
www.v-infinity.com
1-866-372-1258
4/4
VSCP-1K5 Series Switching Power Supply
Rev. 7-2007
Mechanical Drawing
CONTROL PIN ASSIGMENT
VS+
Output Voltage Remote Sense+
VS -
Output Voltage Remote Sense -
VCI
Command input voltage for output programming
VCO 5-10 VDC reference for output programming
FAL
Power Failure detect
PG
Power Good Signal
PAR
Current Sharing / Parallel function
GND Return / Output Ground
INH
Inhibit / Remote On-Off
V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062
www.v-infinity.com
1-866-372-1258