1/4 VSCP-1K2 Series Switching Power Supply Rev. 7-2007 Features ·Current Sharing capability ·0.98 Typical Power Factor ·Programmable Output Voltage ·Universal AC Input ·Short Circuit, overload, over voltage, over temperature protected ·Forced air cooling by built-in DC fan ·Power Failure Signal ·Built-in Remote Sense ·Built-in Remote Inhibit ·2 year warranty Ripple & Noise 3 Output Current Model VSCP-1K2-05 VSCP-1K2-09 VSCP-1K2-12 VSCP-1K2-15 VSCP-1K2-18 VSCP-1K2-24 VSCP-1K2-36 VSCP-1K2-48 VSCP-1K2-60 Output 1 5 V 9 V 12 V 15 V 18 V 24 V 36 V 48 V 60 V Minimum 0A 0A 0A 0A 0A 0A 0A 0A 0A Maximum 2 160/200 A 88/133 A 66/100 A 53/80 A 44/66.6 A 33/50 A 22/33.3 A 16/24 A 13/20 A Max. Power 1000 W 1200 W 1200 W 1200 W 1200 W 1200 W 1200 W 1200 W 1200 W Regulation <1% <1% <1% <1% <1% <1% <1% <1% <1% (Vpp) 1% 1% 1% 1% 1% 1% 1% 1% 1% Efficiency 78% 83% 84% 85% 85% 88% 88% 89% 90% Notes: 1 Output voltage is measured at output power connector. 2 Maximum current is measured at 100-120V input / 200-240V input 3 Ripple and noise is measured from 10 KHz to 20 MHz at output terminals with 0.1 µF ceramic capacitor and a 22 µF electrolytic capacitor in parallel. V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062 www.v-infinity.com 1-866-372-1258 2/4 VSCP-1K2 Series Switching Power Supply Rev. 7-2007 Input Parameter Input frequency Conditions/Description Min 47 Input voltage 100~120 / 200~240 VAC (see derating curve) (130~185 / 260~370 VDC) (see derating curve) 100 130 Inrush Current Peak measured at 230 VAC at full load, cold start Nom Max 63 Units Hz 240 370 VAC VDC 120 A Max Units 25 12 100 mS % -7.5 +7.5 % Output Parameter Conditions/Description Hold-up time Programming Full load at 230 VAC Output voltage programmable through external Min Nom 0~5V control voltage on VCI. Control voltage can also be obtained from VCO via a 470 KOhm pot. See application diagrams. Voltage adjustability Typical adjustment by potentiometer 25%-100% Adjustment by 1-5Vdc external control Temp. coefficient ±0.04 %/ºC Protection Circuit Parameter Overload Overvoltage Conditions/Description Min Nom Max Units Current limiting 3 times (1.5”, 3.0”, 5.0”), then intelligent auto recovery before shutdown 110 135 % General and Safety Parameter Operating temp. Operating humid. Storage temp. Storage humid Vibration EMC Safety regulation Leakage current Cooling Conditions/Description Min Nom 0 20% -20 10 Period of 60 min. for each axis 10 EN55022, EN610000-4-2,3,4,5,6,8,11, EN61000-3-2-3 ENV50204 UL/cUL 1950, TUV EN60950 at 240 VAC Power rating and temperature controlled fan Max 50 90% 85 95 200 Units ºC RH ºC % Hz <7.0 mA Max Units kg mm Mechanical Parameter Weight Enclosure Conditions/Description Min Nom 4.5 290(L) x 120(W) x 132.5(H) Logic Connector Parameter Pin Assignments: Conditions/Description 1. INH - Remote On-Off / Remote Inhibit 2. GND - Return / Output Ground 3. PAR - Current Sharing / Parallel function 4. FAL - Failure 5. VCO - Reference output voltage (5-10 VDC) to be used for output programming 6. VCI - Command input voltage for output programming 7. VS(-) - Remote Sense (-) 8. VS(+) - Remote Sense (+) V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062 www.v-infinity.com 1-866-372-1258 3/4 VSCP-1K2 Series Switching Power Supply Rev. 7-2007 Logic Connections V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062 www.v-infinity.com 1-866-372-1258 4/4 VSCP-1K2 Series Switching Power Supply Rev. 7-2007 Mechanical Drawing CONTROL PIN ASSIGMENT VS+ Output Voltage Remote Sense+ VS - Output Voltage Remote Sense - VCI Command input voltage for output programming VCO 5-10 VDC reference for output programming FAL Power Failure detect PG Power Good Signal PAR Current Sharing / Parallel function GND Return / Output Ground INH Inhibit / Remote On-Off V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062 www.v-infinity.com 1-866-372-1258