1600 Wall System 1 / System 2 ® ® Imposing Statements – Used Together Or Independently Knight Oil Tools Corporate Facility, Lafayette, LA Architect: Donald J. Breaux Architect, Lafayette, LA Glazing Contractor: Advantage Glass & Mirror, New Iberia, LA, with installation assistance from DeGeorge Glass Company, Inc., Metairie, LA Building on the proven success of Kawneer's 1600 Wall System® which set the standards for curtain wall engineering, 1600 Wall System®1 and 1600 Wall System®2 provide reliability with versatile features. Both are stick-fabricated, pressure glazed curtain walls for low-to-mid-rise applications and are designed to be used independently or as an integrated system to provide visual impact for almost any type of building. • 1600 Wall System®1 is an outside glazed, captured curtain wall • 1600 Wall System®2 is a Structural Silicone Glazed (SSG) curtain wall Aesthetics Even the smallest details of 1600 System®1/1600 Wall System®2 reflect the aesthetics and reliability that derive from Kawneer's precise engineering and experience. The joinery for both systems is accomplished with concealed fasteners to create unbroken lines and a monolithic appearance. When using optional, open back horizontal mullions, the fillers snap at the edge, producing an uninterrupted sight line. Performance Key aspects of 1600 System®1 and 1600 Wall System®2 are enhanced for higher performance. Pressure equalization has been designed into the system and all components are silicone compatible to provide superior longevity. For installations where severe weather conditions are prevalent, 1600 Wall System®1 has been large missile hurricane impact and cycle tested. Proven through years of high performance, both systems are tested according to industry standards: Air Performance Static Water Penetration Dynamic Water Penetration Structural Performance “U” Value, CRF Sound Transmission Rating Seismic Performance ASTM E-283 ASTM E-331 AAMA 501.1 ASTM E-330 AAMA 1503.1 ASTM E 90-90 AAMA 501.4 For the Finishing Touch Permadonic Anodized finishes are available in Class I and Class II in seven different colors. Painted Finishes, including fluoropolymer that meet or exceed AAMA 2605, are offered in many standard choices and an unlimited number of specially-designed colors. Solvent-free powder coatings add the “green” element with high performance, durability and scratch resistance that meet the standards of AAMA 2604. 1600 Wall System®2 1600 Wall System®1 1600 Wall System®1/1600 Wall System®2: • for reliability • for performance • for versatility • for a smooth, monolithic appearance • for uninterrupted sight lines Kawneer Company, Inc. Technology Park / Atlanta 555 Guthridge Court Norcross, GA 30092 © Kawneer Company, Inc. 2007 kawneer.com 770 . 449 . 5555 LITHO IN U.S.A Form No. 07-2013 Hunter Henry Center at Mississippi State University, Mississippi State, MS Architect: Foil Wyatt Architects & Planners, P.A., Jackson, MS Glazing Contractor: American Glass Company, Inc., Columbus, MS DECEMBER, 2015 1600 Wall SystemTM1 Curtain Wall © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-086 1 FEATURES Features • 1600 Wall SystemTM1 is an outside glazed captured curtain wall • 1600 Wall SystemTM1 has a 2-1/2" (63.5) sight line • Standard 6" (152.4) or 7-1/2" (190.5) depth systems • Standard infill options 1/4" (6.4) and 1" (25.4), other infills available • Thermally Broken by means of a continuous 1/4" (6.4) low conductance spacer • Concealed fastener joinery creates smooth, monolithic appearance • Open-back horizontals and perimeters are available for cost savings • Shear block fabrication method • Corners and splayed mullions available • Offers integrated entrance framing systems • Silicone compatible glazing materials for long-lasting seals • 1600 Wall SystemTM1 has been small and large missile impact and cycle tested • Two color option • PermanodicTM anodized finishes in seven choices • Painted finishes in standard and custom choices Optional Features • Steel reinforcing available • Rain screen and backpans • Optional deep profile and bull nose covers available • Deep and heavy-weight mullions available • Fiberglass pressure plates available • Veneer system available • Integrates with standard Kawneer windows and GLASSventTM for curtain wall • Integrates with VersoleilTM Sunshade Outrigger System and Horizontal or Vertical Single Blade System • Integrates with 1600 PowerShadeTM • Profit$MakerTM plus die sets available • Hurricane impact resistant framing options: 7-1/16" (179.4), 7-13/16" (198.4), 10-1/16" (255.6) & 10-13/16" (274.6) Product Applications • Ideal for low to mid-rise applications where high performance is desired • It also is the right choice for high span applications For specific product applications, Consult your Kawneer representative. kawneer.com ADMD010 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 Wall SystemTM1 Curtain Wall BLANK PAGE ADMD010 kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 DECEMBER, 2015 EC 97911-086 DECEMBER, 2015 1600 Wall SystemTM1 Curtain Wall EC 97911-086 3 INDEX Architects - Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance. LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. PICTORIAL VIEW.................................................................................5 1" INFILL DETAILS...............................................................................6 1/4" INFILL DETAILS............................................................................7 ENTRANCE DETAILS.......................................................................8,9 CORNERS...........................................................................................10 SPLAYED MULLION OPTIONS.........................................................11 GLASSventTM FOR CURTAIN WALL/WINDOWS..............................12 BACKPAN AND MISCELLANEOUS DETAILS..................................13 MISCELLANEOUS FRAMING............................................................14 HURRICANE IMPACT RESISTANT DETAILS..............................15,16 ANCHORING.................................................................................17,18 WIND LOAD CHARTS.................................................................. 19-27 DEADLOAD CHARTS.................................................................. 28-30 THERMAL CHARTS .................................................................... 31-43 The following metric (SI ) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADMD010 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 Wall SystemTM1 Curtain Wall BLANK PAGE ADMD010 kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 DECEMBER, 2015 EC 97911-086 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2015 kawneer.com 1600 Wall SystemTM1 Curtain Wall EC 97911-086 PICTORIAL VIEW ADMD010 5 9A 7 1 3 4 7 5 1A 8 8A 6 6A 8 9 ADMD010 2 3 8A 4 9B OPTIONAL STEEL REINFORCING AS REQUIRED 5 6A 6 kawneer.com © Kawneer Company, Inc., 2014 1" INFILL DETAILS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 Wall SystemTM1 Curtain Wall Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. ELEVATION IS NUMBER KEYED TO DETAILS 2-1/2" (63.5) 9 9A 9B 7-1/2" (190.5) 2 6" (152.4) 6 DECEMBER, 2015 EC 97911-086 SCALE 3" = 1'-0" 1 1A 6" (152.4) 7 -1/2" (190.5) 2-1/2" (63.5) © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. ELEVATION IS NUMBER KEYED TO DETAILS 7A kawneer.com 6 2-1/2" (63.5) 6A ADMD010 2-1/2" (63.5) 6 -3/4" (171.5) 7 7A 7B 5-1/4" (133.4) DECEMBER, 2015 1600 Wall SystemTM1 Curtain Wall EC 97911-086 1/4" INFILL DETAILS SCALE 3" = 1'-0" 1 1A 2 1 3 6 6A 4 1A 5 5A 2 5-1/4" (133.4) 6 -3/4" (171.5) 7 3 7B OPTIONAL STEEL REINFORCING AS REQUIRED 4 5A 5 7 1600 Wall SystemTM1 Curtain Wall 8 DECEMBER, 2015 ENTRANCE DETAILS (1" INFILL) EC 97911-086 SCALE 3" = 1'-0" 1 1A 3 5 2 4 6 TRANSOM BAR B/H OR O/P C/H BUTT HUNG OR OFFSET PIVOT WITH SURFACE CLOSER OR FLOOR CLOSER B/H OR O/P ELEVATION IS NUMBER KEYED TO DETAILS 1A DOOR JAMB 1-15/16" (88.9) TYP. BUTT HUNG OR OFFSET PIVOT 2 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH SINGLE ACTING CONCEALED OVERHEAD CLOSER 3 CENTER HUNG 4 TRANSOM BAR CENTER HUNG CONCEALED OVERHEAD OR FLOOR CLOSER DOOR JAMB BUTT HUNG OR OFFSET PIVOT 5 6 TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH LCN CONCEALED OVER HEAD CLOSER OR SURFACE CLOSER ADMD010 kawneer.com © Kawneer Company, Inc., 2014 DOOR JAMB Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3/4" (19) TYP. 1600 Wall SystemTM1 Curtain Wall DECEMBER, 2015 EC 97911-086 9 ENTRANCE DETAILS (1/4" INFILL) SCALE 3" = 1'-0" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 1A 3 2 4 B/H OR O/P 1 TRANSOM BAR C/H BUTT HUNG OR OFFSET PIVOT WITH SURFACE CLOSER OR FLOOR CLOSER ELEVATION IS NUMBER KEYED TO DETAILS DOOR JAMB BUTT HUNG OR OFFSET PIVOT TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH SINGLE ACTING CONCEALED OVERHEAD CLOSER 3/4" (19.1) TYP. DOOR JAMB CENTER HUNG © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1-15/16" (88.9) TYP. 2 1A 3 4 TRANSOM BAR CENTER HUNG CONCEALED OVERHEAD OR FLOOR CLOSER kawneer.com ADMD010 90° OUTSIDE CORNER 90° INSIDE CORNER 90° OUTSIDE CORNER 135° OUTSIDE CORNER 135° OUTSIDE CORNER 135° INSIDE CORNER ADMD010 kawneer.com © Kawneer Company, Inc., 2014 CORNERS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 Wall SystemTM1 Curtain Wall Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 10 DECEMBER, 2015 EC 97911-086 SCALE 3" = 1'-0" NOTE: 1" SYSTEM SHOWN, 1/4" SYSTEM SIMILAR. © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2015 0° TO 5° 0° TO 5° kawneer.com 1600 Wall SystemTM1 Curtain Wall EC 97911-086 SPLAYED MULLION OPTIONS SCALE 3" = 1'-0" 5° TO 15° 5° TO 15° INSIDE SPLAYED MULLIONS ADMD010 15° TO 25° OUTSIDE SPLAYED MULLIONS 15° TO 25° 11 HEAD SILL JAMB 8225TL THERMAL WINDOWS NOTE: Other vent types can be accommodated. Contact your Kawneer representative for other options. HEAD SILL JAMB ADMD010 kawneer.com © Kawneer Company, Inc., 2014 GLASSventTM FOR CURTAIN WALL/WINDOWS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 Wall SystemTM1 Curtain Wall Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 12 DECEMBER, 2015 EC 97911-086 SCALE 3" = 1'-0" GLASSventTM FOR CURTAIN WALL © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. kawneer.com 6 7 3 ELEVATION IS NUMBER KEYED TO DETAILS NOTE: 6" SYSTEM SHOWN, 7-1/2" SYSTEM SIMILAR 1 JAMB MULLION AT SPANDREL (With vapor barrier tie-in) 3 THERMALLY BROKEN DOOR ADAPTOR FOR INSULCLAD DOORS 1/2" (12.7) 2 D.L.O. 1 3/8" (9.5) 2-1/2" (63.5) 3/8" (9.5) D.L.O. MULLION LENGTH CONSTRUCTION JOINT 1/2" (12.7) MAX (ALLOWS +/-1/4" MOVEMENT) 5 MULLION LENGTH Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2015 1600 Wall SystemTM1 Curtain Wall EC 97911-086 BACKPAN AND MISCELLANEOUS DETAILS SCALE 3" = 1'-0" 4 4 HEAD TRANSOM AT PARAPET FLASHING 5 EXPANSION JOINT 2 6 MULLION AT SPANDREL TYPICAL DEADLOAD ANCHOR 3 7 AATM 250 THERMAL DOOR TRANSOM – SPANDREL OVER VISION ADMD010 13 1600 Wall SystemTM1 Curtain Wall 14 DECEMBER, 2015 MISCELLANEOUS FRAMING EC 97911-086 SCALE 3" = 1'-0" 3" (76.2) 2-1/2" (63.5) 1-1/4" (31.8) CAPTURED MULLION (1") 4-3/4" (120.7) 2-3/4" (69.7) 2" (50.8) 1-3/16" (30.1) 7-1/2" (190.5) 6" (152.4) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Architects – Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance. 4" (101.6) OPTIONAL FIBERGLASS PRESSURE PLATE 2-1/2" (63.5) OPTIONAL COVERS 4" SIGHT LINE 2-1/2" (63.5) DOUBLE MULLION VENEER SYSTEM 069263 GYPSUM BOARD TRIM 2-1/2" (63.5) DEEP MULLION STOOL TRIM OPTIONS: 069264 - 2-3/4" (69.9) 069265 - 4-1/2" (114.3) 069266 - 5" (127.0) 069267 - 6-1/8" (155.6) 069268 - 6-3/4" (171.4) NOTE: STOOL TRIMS REQUIRE 069271 TRIM CLIP PACKAGE INTERIOR STOOL TRIM ADMD010 kawneer.com © Kawneer Company, Inc., 2014 2-1/2" (63.5) VARIES 2-1/2" (63.5) 2-1/2" (63.5) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 10-1/2" (266.7) 2-1/2" (63.5) 1-3/4" (44.5) OPTIONAL COVERS 3-19/32" (91.3) © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. EC 97911-086 SCALE 3" = 1'-0" 5 5A kawneer.com 7 5 6 8 ELEVATION IS NUMBER KEYED TO DETAILS EXPANSION HORIZONTAL OPTIONAL STEEL REINFORCING AS REQUIRED ADMD010 2-3/4" (69.9) 2-1/2" (63.5) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2015 1600 Wall SystemTM1 Curtain Wall 3 10 6 3-19/32" (91.3) 15 HURRICANE IMPACT RESISTANT DETAILS NOTE: DETAILS SHOWN WITH 9/16" INFILL AND ARE GLAZED FOR FOR LARGE MISSLE IMPACT (LMI). SEE NEXT PAGE FOR OTHER GLAZING OPTIONS. 1 2 1 7-1/16" (179.4) 2 9 4 3 4 7 5A 1600 Wall SystemTM1 Curtain Wall DECEMBER, 2015 EC 97911-086 HURRICANE IMPACT RESISTANT DETAILS SCALE 3" = 1'-0" NOTE: 350 IR DOORS ARE USED WITH IMPACT FRAMING. DOORS ARE GLAZED WITH 9/16" INFILL. 8 9 7-1/16" (179.4) DOOR JAMB AT MULLION 9/16" INFILL LARGE MISSILE (LMI) DOOR JAMB AT PERIMETER 3/32" (2.4) 7/8" (22.2) 3-1/2" (88.9) OPTIONAL 10" DEEP SYSTEM 1-5/16" INFILL LARGE MISSILE (LMI) 2-1/2" (63.5) 2-1/2" (63.5) 1-5/16" INFILL SMALL MISSILE (SMI) 2-1/2" (63.5) 9/16" INFILL (SMI) SMALL MISSILE IMPACT 2-1/2" (63.5) GLAZING OPTIONS 7-13/16" (198.4) 7-1/16" (179.4) 9/16" INFILL SMALL MISSILE (SMI) OVER 9/16" INFILL LARGE MISSILE (LMI) 1-5/16" INFILL LARGE MISSILE (LMI) ADMD010 kawneer.com © Kawneer Company, Inc., 2014 10 TRANSOM BAR 9/16" INFILL LARGE MISSILE (LMI) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3-1/2" (88.9) 1/8" (3.2) 10-1/16" (255.6) 1-3/4" (44.5) 1/8" 2-1/2" (63.5) OPTIONAL 10" DEEP SYSTEM 9/16" INFILL LARGE MISSILE (LMI) 10-13/16" (274.6) 2-1/2" (63.5) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 16 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2015 kawneer.com 1600 Wall SystemTM1 Curtain Wall EC 97911-086 ANCHORING Actual project conditions will determine specific anchor design. Details on this page are for reference only. 1" (25.4) MINIMUM ANCHORING TO FLOOR SLAB 1" (25.4) MINIMUM ANCHORING TO SUPPORT STEEL ADMD010 17 1" (25.4) MINIMUM ANCHORING TO HORIZONTAL STRUCTURAL STEEL 1" (25.4) MINIMUM ANCHORING TO VERTICAL STRUCTURAL STEEL ADMD010 kawneer.com © Kawneer Company, Inc., 2014 ANCHORING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 Wall SystemTM1 Curtain Wall Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 18 DECEMBER, 2015 EC 97911-086 Actual project conditions will determine specific anchor design. Details on this page are for reference only. DECEMBER, 2015 1600 Wall SystemTM1 Curtain Wall 19 WIND LOAD / DEADLOAD CHARTS EC 97911-086 Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted curves, in all cases are for the limiting value. Wind load charts contained herein are based upon nominal wind load utilized in allowable stress design. To convert ultimate wind loads to nominal loads, multiply ultimate wind loads by a factor of 0.6 per ASCE/SEI 7. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. DEADLOAD CHARTS Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1" (25.4) thick insulating glass or 1/4" (6.4) thick glass supported on two setting blocks placed at the loading points shown. © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WIND LOAD CHARTS kawneer.com ADMD010 1600 Wall SystemTM1 Curtain Wall 20 DECEMBER, 2015 WIND LOAD CHARTS (1" INFILL) SINGLE SPAN 1 1.5 2 7 23 TWIN SPAN A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) METERS .5 EC 97911-086 22 METERS .5 2 9 28 8.5 27 A 26 5.5 4.5 14 4 13 A B 3.5 C 10 22 6.5 21 20 D 6 19 E 18 5.5 5 16 E 8 7 C 17 3 D 9 B 23 2.5 7 15 162001 2 4.5 14 4 13 6 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET I = 5.035(209.57 x 104) S = 1.993(32.66 x 103) 8 12 0 1 2 SINGLE SPAN 1 4 5 6 7 8 TWIN SPAN METERS METERS .5 3 MULLION CENTERS IN FEET 1.5 .5 2 7 23 1 1.5 2 30 9 22 29 6.5 20 6 8 26 5.5 A 4 13 B 12 3.5 11 C 10 7.5 24 C 23 7 22 6.5 21 D 20 6 19 E 18 5.5 17 3 D 9 MULLION HEIGHT IN FEET 4.5 14 MULLION HEIGHT EQUAL EQUAL 15 METERS 5 6" (152.4) 17 16 B 25 MULLION HEIGHT 18 MULLION HEIGHT IN FEET 8.5 27 19 5 16 E 8 2.5 7 2 15 162002 4.5 14 4 13 6 5 A 28 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET 8 METERS 21 I = 6.779(282.16 x 104) S = 2.652(43.46 x 103) ADMD010 12 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET 8 kawneer.com © Kawneer Company, Inc., 2014 11 7.5 24 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 12 MULLION HEIGHT IN FEET 15 METERS 5 16 6" (152.4) 17 MULLION HEIGHT EQUAL EQUAL 25 MULLION HEIGHT 18 8 METERS 6 19 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 6.5 20 MULLION HEIGHT IN FEET 1.5 29 21 5 1 30 1600 Wall SystemTM1 Curtain Wall DECEMBER, 2015 EC 97911-086 WIND LOAD CHARTS (1" INFILL) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN METERS .5 21 1 1.5 2 7 23 TWIN SPAN METERS .5 1 1.5 2 30 9 6.5 A 28 8.5 27 6 B 26 19 5.5 4.5 A 14 B 13 4 C 12 3.5 D 11 E 10 MULLION HEIGHT IN FEET 15 METERS 5 16 7-1/2" (190.5) 17 MULLION HEIGHT EQUAL EQUAL 25 MULLION HEIGHT 18 8 7.5 C 24 7 23 D 22 6.5 21 E 20 6 19 5.5 18 17 3 5 16 9 2.5 8 15 162003 7 2 1 2 3 4 5 6 7 4.5 14 4 13 6 0 I = 10.135(421.85 x 104) S = 3.027(49.60 x 103) 8 12 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET MULLION CENTERS IN FEET SINGLE SPAN TWIN SPAN METERS .5 1 METERS 20 5 8 METERS 1.5 .5 2 7 23 1 1.5 2 30 9 29 6.5 21 20 28 6 8 26 5.5 4.5 B 13 4 C 12 D 3.5 11 E 10 MULLION HEIGHT IN FEET A 14 MULLION HEIGHT EQUAL EQUAL 15 METERS 5 7-1/2" (190.5) 17 16 D 25 MULLION HEIGHT 18 MULLION HEIGHT IN FEET 8.5 C 27 19 7.5 E 24 7 23 22 6.5 21 20 6 19 5.5 18 17 3 9 5 16 2.5 8 162004 7 2 15 4.5 14 4 13 6 5 B 0 1 2 3 4 5 6 7 8 I = 12.736(530.11 x 104) S = 3.791(62.12 x 103) MULLION CENTERS IN FEET kawneer.com 12 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET ADMD010 8 METERS 22 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 29 21 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 22 1600 Wall SystemTM1 Curtain Wall 22 DECEMBER, 2015 WIND LOAD CHARTS (1" INFILL) SINGLE SPAN METERS 1 1.5 SINGLE SPAN A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) 162004 W/162300 .5 EC 97911-086 2 30 162004 W/162301 METERS .5 1 1.5 2 30 9 9 28 8.5 25 MULLION HEIGHT 7 23 22 6.5 21 A 20 6 B 19 18 MULLION HEIGHT IN FEET 7.5 24 METERS 5.5 C 17 7.5 24 7 23 22 A 21 6.5 B 20 6 19 C 5.5 18 17 5 16 D 15 4.5 E 14 4 13 0 1 2 3 4 5 6 7 D 16 8 162004 W/162300 162004 W/162301 Ia = 12.736(530.11 x 104) Sa = 3.791(62.12 x 103) Is = 3.805(158.37 x 104) Ss = 1.669(27.35 x 103) Ia = 12.736(530.11 x 104) Sa = 3.791(62.12 x 103) Is = 5.684(236.59 x 104) Ss = 2.493(40.85 x 103) 5 E 15 4.5 14 4 13 12 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET MULLION CENTERS IN FEET SINGLE SPAN SINGLE SPAN 162004 W/162301/302 162004 W/162301/302/303 METERS .5 1 8 METERS 1.5 .5 2 30 1 1.5 2 30 9 9 29 29 28 28 8.5 27 8 26 25 6.5 21 B 6 19 C 18 7-1/2" (190.5) 7 A 22 20 MULLION HEIGHT 24 MULLION HEIGHT IN FEET 7.5 23 8 26 METERS MULLION HEIGHT IN FEET 25 5.5 17 7.5 24 A 7 23 22 B 21 D 5 E 15 4.5 14 4 13 0 1 2 3 4 5 6 7 8 162004 W/162301/302/303 Ia = 12.736(530.11 x 104) Sa = 3.791(62.12 x 103) Is = 7.893(328.53 x 104) Ss = 3.462(56.73 x 103) Ia = 12.736(530.11 x 104) Sa = 3.791(62.12 x 103) Is = 9.347(389.05 x 104) Ss = 4.100(67.19 x 103) MULLION CENTERS IN FEET 6 C 19 5.5 18 D 5 16 162004 W/162301/302 6.5 20 17 16 12 8.5 27 METERS MULLION HEIGHT IN FEET 25 8 26 METERS 8 26 12 8.5 27 E 15 4.5 14 4 13 12 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET ADMD010 kawneer.com © Kawneer Company, Inc., 2014 28 27 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 29 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 29 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE SPAN METERS 12 0 kawneer.com 1 1 2 3 1.5 26 25 23 22 A 21 6.5 20 19 B 18 17 D 16 E 4 5 6 6 C 5.5 15 13 4 7 MULLION CENTERS IN FEET 8 10-1/2" (266.7) 28 MULLION HEIGHT .5 METERS DECEMBER, 2015 1600 Wall SystemTM1 Curtain Wall EC 97911-086 WIND LOAD CHARTS (1" INFILL) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) 2 8.5 27 8 24 7.5 7 5 14 4.5 162064 I = 42.441(1766.52 x 104) S = 8.816(144.74 x 103) ADMD010 23 1600 Wall SystemTM1 Curtain Wall 24 DECEMBER, 2015 WIND LOAD CHARTS (1/4" INFILL) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN METERS .5 1 1.5 2 7 23 EC 97911-086 TWIN SPAN METERS .5 1 1.5 2 30 9 22 28 5.5 4 13 12 5-1/4" (133.4) 3.5 11 A 10 3 B 9 C D 8 E 7 2 3 4 5 6 7 7 23 22 B 21 6.5 20 6 19 C 18 5.5 D 16 5 E 15 4.5 14 2 1 7.5 24 17 2.5 162013 6 0 MULLION HEIGHT IN FEET 4.5 14 MULLION HEIGHT EQUAL EQUAL 15 METERS 5 16 8 25 17 MULLION HEIGHT 18 MULLION HEIGHT IN FEET A 26 8 4 13 I = 3.662(152.42 x 104) S = 1.662(27.24 x 103) 12 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET MULLION CENTERS IN FEET SINGLE SPAN TWIN SPAN METERS .5 1 METERS 1.5 .5 2 7 23 1 1.5 2 30 9 22 29 6.5 20 28 6 5.5 4 13 12 A 11 3.5 B 10 3 C 9 D 8 2 0 1 2 3 4 5 6 7 8 7 23 C 22 6.5 21 20 6 D 19 E 18 5.5 5 16 2.5 6 7.5 24 17 15 E 7 MULLION HEIGHT IN FEET 4.5 14 MULLION HEIGHT EQUAL EQUAL 15 METERS 5 16 5-1/4" (133.4) 17 8 B 25 MULLION HEIGHT 18 MULLION HEIGHT IN FEET A 26 19 5 8.5 27 METERS 21 4.5 14 162014 I = 4.5071(87.60 x 104) S = 1.968(32.25 x 103) MULLION CENTERS IN FEET 4 13 12 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET ADMD010 kawneer.com © Kawneer Company, Inc., 2014 6 19 5 8.5 27 METERS 20 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 6.5 21 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 29 1600 Wall SystemTM1 Curtain Wall DECEMBER, 2015 EC 97911-086 WIND LOAD CHARTS (1/4" INFILL) SINGLE SPAN .5 1 1.5 2 7 23 TWIN SPAN A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) METERS METERS .5 1.5 2 9 29 6.5 20 A 28 8.5 27 6 8 26 19 5.5 13 4 B 12 C 11 3.5 D 10 3 MULLION HEIGHT IN FEET 4.5 A 14 6-3/4" (171.5) 15 METERS 5 16 MULLION HEIGHT EQUAL EQUAL 25 17 MULLION HEIGHT 18 2.5 7 162015 3 6.5 20 6 19 D 18 5.5 E 5 4 5 6 7 4.5 14 2 2 C 21 15 6 1 7 22 16 8 0 7.5 23 17 E 9 B 24 8 4 13 I = 7.915(329.45 x 104) S = 2.635(43.18 x 103) 12 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET MULLION CENTERS IN FEET SINGLE SPAN TWIN SPAN METERS .5 1 METERS 21 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. METERS 1.5 .5 2 7 23 1 1.5 2 30 9 29 6.5 21 20 8.5 B 27 6 8 26 19 5.5 B 13 4 C 12 3.5 11 D 10 3 E MULLION HEIGHT IN FEET 4.5 A 14 MULLION HEIGHT EQUAL EQUAL 15 METERS 5 6-3/4" (171.5) 17 16 C 25 MULLION HEIGHT 18 MULLION HEIGHT IN FEET A 28 7.5 24 23 7 D 22 6.5 21 E 20 6 19 5.5 18 17 9 5 16 2.5 8 7 2 15 6 162016 13 5 I = 9.594(399.33 x 104) S = 3.163(51.83 x 103) 12 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET kawneer.com 4.5 14 4 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET ADMD010 8 METERS 22 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 30 22 5 25 1600 Wall SystemTM1 Curtain Wall 26 DECEMBER, 2015 WIND LOAD CHARTS (1/4" INFILL) SINGLE SPAN METERS 1 1.5 SINGLE SPAN A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) 162016 W/162300 .5 EC 97911-086 2 30 162016 W/162301 METERS .5 1 1.5 2 30 9 9 28 8.5 25 MULLION HEIGHT 7 23 22 A 21 6.5 20 6 19 B 18 17 5.5 5 4.5 D E 0 1 2 3 7 23 22 6.5 21 A 20 B 6 19 18 5.5 C 4 4 5 6 7 5 16 14 13 7.5 24 17 C 16 15 MULLION HEIGHT IN FEET 7.5 24 METERS 8 162016 W/162300 162016 W/162301 Ia = 9.594(399.33 x 104) Sa = 3.163(51.83 x 103) Is = 3.805(158.37 x 104) Ss = 1.669(27.35 x 103) Ia = 9.594(399.33 x 104) Sa = 3.163(51.83 x 103) Is = 5.684(236.59 x 104) Ss = 2.493(40.85 x 103) D 15 4.5 E 14 4 13 12 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET MULLION CENTERS IN FEET SINGLE SPAN SINGLE SPAN 162016 W/162301/302 162016 W/162301/302/303 METERS .5 1 METERS 1.5 .5 2 30 1 1.5 2 30 9 9 29 29 28 28 8.5 27 8 26 6.5 21 20 B 6 19 18 MULLION HEIGHT IN FEET 7 A 6-3/4" (171.5) MULLION HEIGHT 24 22 5.5 C A 25 7.5 23 8 26 METERS MULLION HEIGHT IN FEET 25 17 7.5 24 7 23 B 22 6.5 21 C 20 6 19 D 15 D 5 E 4.5 14 4 13 0 1 2 3 4 5 6 7 8 5.5 18 17 16 12 8.5 27 E 5 16 162016 W/162301/302 162016 W/162301/302/303 Ia = 9.594(399.33 x 104) Sa = 3.163(51.83 x 103) Is = 7.893(328.53 x 104) Ss = 3.462(56.73 x 103) Ia = 9.594(399.33 x 104) Sa = 3.163(51.83 x 103) Is = 9.347(389.05 x 104) Ss = 4.100(67.19 x 103) MULLION CENTERS IN FEET METERS MULLION HEIGHT IN FEET 25 8 26 METERS 8 26 12 8.5 27 15 4.5 14 4 13 12 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET ADMD010 kawneer.com © Kawneer Company, Inc., 2014 28 27 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 29 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 29 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE SPAN METERS 12 0 kawneer.com 1 1 2 3 1.5 22 21 20 19 18 17 16 4 5 2 8.5 26 25 23 7 A 6.5 B 6 C D 5.5 E 15 13 MULLION CENTERS IN FEET 6 7 9-3/4" (247.7) 28 MULLION HEIGHT .5 METERS DECEMBER, 2015 1600 Wall SystemTM1 Curtain Wall EC 97911-086 WIND LOAD CHARTS (1/4" INFILL) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) 27 8 24 7.5 5 14 4.5 4 8 I = 36.451(1517.20 x 104) S = 8.279(135.67 x 103) 162213 ADMD010 27 GLASS HEIGHT IN FEET 0 0 162001 6 5 13 1 2 .5 2 3 4 1 3 4 5 8 7 5 6 1.5 6 METERS 2 13 12 11 10 3 9 8 2.5 7 A 7 9 7 2 B 1.5 4 3 1 2 0.5 1 8 10 A 5 3 2 0 2 12 3.5 11 3 2.5 B 2 6 1.5 4 1 0.5 1 8 0 SPAN IN FEET ADMD010 .5 METERS 0 0 1 13 1 1 2 METERS .5 2 3 3 1.5 SPAN IN FEET SPAN IN FEET 4 162003 1 4 5 7-1/2" (190.5) 7-1/2" (190.5) 5 2 3.5 12 11 3.5 10 9 3 8 2.5 7 6 A 5 6 1.5 7 6 7 9 7 2 B 4 1.5 3 1 2 0.5 10 A 8 B 6 2 5 3 2 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 162002 162004 METERS 2 12 11 3.5 3 2.5 4 1.5 1 1 0.5 SPAN IN FEET 8 kawneer.com © Kawneer Company, Inc., 2014 1 A - 1/4" GLASS (1/4 POINT LOADING) B - 1" GLASS (1/4 POINT LOADING) METERS DEADLOAD CHARTS (TUBULAR) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0 1.5 GLASS HEIGHT IN FEET 1600 Wall SystemTM1 Curtain Wall METERS 0 1 GLASS HEIGHT IN FEET 13 .5 METERS 6" (152.4) METERS GLASS HEIGHT IN FEET 28 DECEMBER, 2015 EC 97911-086 6" (152.4) 1 8 GLASS HEIGHT IN FEET © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0 kawneer.com 5-1/4" (133.4) 162013 METERS 0 1 13 1 2 .5 2 3 3 4 1 4 5 5 2 6 1.5 9 8 6 13 12 11 A 3 9 8 2.5 7 2 6 5 1.5 4 3 1 2 0.5 1 7 7 8 10 A 7 5 3 2 0 2 12 11 3 2.5 6 2 1.5 4 1 0.5 1 8 0 SPAN IN FEET ADMD010 .5 0 0 1 13 1 1 2 METERS .5 2 3 162015 3 1.5 3.5 10 A 8 7 6 2 5 3 2 SPAN IN FEET SPAN IN FEET 4 1 4 5 6-3/4" (171.5) 6-3/4" (171.5) SPAN IN FEET 5 6 1.5 9 6 7 3.5 10 A 8 7 6 2 5 1.5 4 3 1 2 1 0.5 7 8 METERS 10 GLASS HEIGHT IN FEET EC 97911-086 METERS 0 1.5 GLASS HEIGHT IN FEET 0 1 METERS 13 .5 METERS GLASS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2015 1600 Wall SystemTM1 Curtain Wall 29 DEADLOAD CHARTS (TUBULAR) A - 1/4" GLASS (1/4 POINT LOADING) 5-1/4" (133.4) 162014 METERS 2 12 11 3.5 9 3 2.5 4 1.5 1 1 0.5 8 162016 METERS 2 12 11 3.5 3 2.5 1600 Wall SystemTM1 Curtain Wall DECEMBER, 2015 DEADLOAD CHARTS (OPEN BACK) A - 1" GLASS (1/8 POINT LOADING) B - 1" GLASS (1/4 POINT LOADING) 162095 162091 (DOTTED) 1 METERS 1.5 2 10 3 A 8 2.5 7 2 6 B 5 METERS 9 1.5 4 1 3 2 2.5 8 7 B 6 2 5 1.5 4 1 3 2 0.5 1 0 1 2 3 4 5 6 7 1 2 3 4 5 6 7 8 0.5 0 1 2 1 .5 8 METERS 1.5 2 5 1.5 4 1 3 2 0.5 1 9 2.5 B 7 2 6 5 1.5 4 1 3 2 0.5 1 0 7 8 3 9 2.5 8 7 B 6 2 5 1.5 4 1 3 2 0.5 1 0 6 A 10 3 GLASS HEIGHT IN FEET 2 A 8 3.5 11 METERS B METERS 2.5 8 GLASS HEIGHT IN FEET 9 2 12 3.5 10 3 1.5 13 11 A 10 1 .5 12 3.5 11 SPAN IN FEET 7 162097 METERS 2 12 5 6 162093 (DOTTED) 13 4 5 6-3/4" (171.5) 162095 162091 (DOTTED) 13 6 4 162078 REINF. 1.5 7 3 A - 1/4" GLASS (1/8 POINT LOADING) B - 1/4" GLASS (1/4 POINT LOADING) A - 1" GLASS (1/8 POINT LOADING) B - 1" GLASS (1/4 POINT LOADING) METERS 3 1 SPAN IN FEET 162094 162090 (DOTTED) 2 1.5 4 SPAN IN FEET 162077 REINF. 1 5 7-1/2" (190.5) 1 2 B 6 0 6" (152.4) 0 7 1 0 A - 1" GLASS (1/8 POINT LOADING) B - 1" GLASS (1/4 POINT LOADING) .5 2.5 8 2 0.5 0 8 3 A 9 3 1 SPAN IN FEET GLASS HEIGHT IN FEET 10 3 A 9 3.5 11 GLASS HEIGHT IN FEET 10 2 12 3.5 11 GLASS HEIGHT IN FEET 11 1.5 13 METERS 3.5 1 .5 12 12 GLASS HEIGHT IN FEET METERS 1.5 13 13 0 1 .5 2 0 0 1 2 3 4 5 SPAN IN FEET ADMD010 6 7 8 0 1 2 3 4 5 6 7 8 SPAN IN FEET kawneer.com © Kawneer Company, Inc., 2014 METERS 162096 162092 (DOTTED) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 162094 162090 (DOTTED) .5 5-1/4" (133.4) 7-1/2" (190.5) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 6" (152.4) A - 1/4" GLASS (1/8 POINT LOADING) B - 1/4" GLASS (1/4 POINT LOADING) METERS A - 1" GLASS (1/8 POINT LOADING) B - 1" GLASS (1/4 POINT LOADING) EC 97911-086 METERS 30 1600 Wall SystemTM1 Curtain Wall DECEMBER, 2015 EC 97911-086 THERMAL CHARTS Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines) (Based on single bay of Curtain Wall/Window Wall) 2-1/2" Typ. 4'-0" 3'-0" D.L.O. D.L.O. VISION VISION 6'-0" D.L.O. SPANDREL 9'-0" D.L.O. 31'-3" 8'-0" D.L.O. SPANDREL VISION 5'-0" D.L.O. Vision Area Example Glass U-factor = 0.48 Btu/(ft2 · h · °F) Vision Area = 5(9 + 8 + 4) = 105.0 ft2 Total Area (Vision) = 5' 2-1/2" (9' 3-3/4" + 8' 2-1/2" + 4' 2-1/2") = 113.2 ft2 Percentage of Vision Glass = (Vision Area ÷ Total Area)100 = (105.0 ÷ 113.2)100 = 93% © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2-1/2" Typ. Spandrel Area Example Spandrel R-value = 15 (ft2 · h · °F)/Btu Spandrel Area = 5(6 + 3) = 45.0 ft2 Total Area (Spandrel) = 5' 2-1/2" (6' 2-1/2" + 3' 3-3/4") = 49.6 ft2 Percent of Spandrel kawneer.com = (Spandrel Area ÷ Total Area)100 = (45.0 ÷ 49.6)100 = 91% ADMD010 31 32 1600 Wall SystemTM1 Curtain Wall DECEMBER, 2015 THERMAL CHARTS EC 97911-086 Vision Area Chart System U-factor vs Percent of Vision Area E IGN PL S M E A D EX FOR T COG U-factor 0.53 0.50 0.40 0.30 ) 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.60 Btu h·ft 2·°F System U-factor O (N 0.70 93% 0.20 95 85 90 75 80 70 Vision Area / Total Area (%) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.80 System U-factor vs Percent of Spandrel Area Spandrel R-value E IGN PL S M E A D EX FOR O 0.50 T 3.00 4.00 5.00 0.21 0.20 0.10 91% 95 0.30 ) 11.00 15.00 19.00 30.00 0.40 Btu h·ft 2·°F System U-factor (N 2.00 0.60 90 85 80 75 70 Spandrel Area / Total Area (%) Based on a single curtain wall bay of 91% spandrel and center of spandrel R-value of 15, system U-factor is equal to 0.21 Btu/(h·ft 2·°F) ADMD010 kawneer.com © Kawneer Company, Inc., 2014 Spandrel Area Chart Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Based on a single curtain wall bay of 93% vision glass and center of glass U-factor of 0.48, System U-factor is equal to 0.53 Btu/(h·ft 2·°F) DECEMBER, 2015 1600 Wall SystemTM1 Curtain Wall EC 97911-086 33 THERMAL CHARTS Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-Factor for Vision Glass 1.30 1.20 (7.00) 1.15 1.10 (6.50) 1.05 (6.00) 1.00 0.95 0.75 0.70 0.65 0.60 COG U-factor © Kawneer Company, Inc., 2014 (4.50) (4.00) (3.50) 0.55 0.48 (2.73) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.50 (3.00) 0.45 (2.50) 0.40 0.35 (2.00) 0.30 0.25 0.20 Vision Area / Total Area (%) kawneer.com (5.00) ADMD010 (1.50) System U-Factor (W/m2·°C) 0.85 (5.50) System U-Factor (Btu/h·ft2·°F) 0.90 0.80 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. (7.50) 1.25 0.70 0.65 0.60 0.55 0.50 Spandrel R-Value 0.45 2.00 0.40 0.35 3.00 0.30 4.00 5.00 0.25 0.20 15.00 19.00 30.00 11.00 95 90 85 80 ADMD010 75 Spandrel Area / Total Area (%) kawneer.com © Kawneer Company, Inc., 2014 System U-Factors for Spandrel Glass Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. THERMAL CHARTS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1600 Wall SystemTM1 Curtain Wall System U-Factor (Btu/h·ft2·°F) 34 DECEMBER, 2015 EC 97911-086 Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. 0.15 0.10 70 0.05 System VT © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2015 kawneer.com 1600 Wall SystemTM1 Curtain Wall EC 97911-086 Vision Ares / Total Area (%) Charts are generated per AAMA 507. ADMD010 35 THERMAL CHARTS System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) Charts are generated per AAMA 507. System Visible Transmittance (VT) vs Percent of Vision Area COG VT 1600 Wall SystemTM1 Curtain Wall DECEMBER, 2015 THERMAL PERFORMANCE MATRIX (NFRC SIZE) 0.48 0.61 0.46 0.60 0.44 0.58 0.42 0.56 0.40 0.55 0.38 0.53 0.36 0.51 0.34 0.50 0.32 0.48 0.30 0.47 0.28 0.45 0.26 0.43 0.24 0.42 0.22 0.40 0.20 0.38 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.69 0.75 0.67 0.70 0.64 0.70 0.63 0.65 0.60 0.65 0.58 0.60 0.55 0.60 0.54 0.55 0.51 0.55 0.49 0.50 0.46 0.50 0.45 0.45 0.42 0.45 0.40 0.40 0.37 0.40 0.36 0.35 0.33 0.35 0.31 0.30 0.28 0.30 0.27 0.25 0.24 0.25 0.22 0.20 0.20 0.20 0.18 0.15 0.15 0.15 0.13 0.10 0.11 0.10 0.09 0.05 0.06 0.05 0.04 ADMD010 kawneer.com © Kawneer Company, Inc., 2014 Overall U-Factor 4 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1" GLAZING WITH ALUMINUM PRESSURE PLATE Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Glass U-Factor 3 EC 97911-086 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 36 1600 Wall SystemTM1 Curtain Wall DECEMBER, 2015 EC 97911-086 37 THERMAL CHARTS 1600 SystemTM1 with GLASSventTM - Projecting (Awning - Single) Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-Factor for Vision Glass 1.00 (6.00) 0.95 0.90 (5.00) System U-Factor (Btu/h·ft2·°F) 0.80 (4.50) 0.75 COG U-factor 0.70 0.48 (2.73) 0.44 (2.50) 0.42 (2.39) (4.00) 0.65 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.60 0.34 (1.93) 0.32 (1.82) (3.50) 0.30 (1.71) 0.28 (1.59) 0.55 0.26 (1.48) 0.24 (1.37) © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.46 (2.61) 0.22 (1.25) 0.50 0.20 (1.14) 0.45 Percent of Glass Area = Vision Area/Total Area Daylight Opening / Projected Area Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. kawneer.com ADMD010 (3.00) System U-Factor (W/m2·°C) 0.85 COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area COG VT Vision Area / Total Area (%) ADMD010 kawneer.com © Kawneer Company, Inc., 2014 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System SHGC 1600 Wall SystemTM1 Curtain Wall Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System VT 38 DECEMBER, 2015 EC 97911-086 1600 SystemTM1 with GLASSventTM - Projecting (Awning - Single) System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area 1600 Wall SystemTM1 Curtain Wall DECEMBER, 2015 EC 97911-086 THERMAL PERFORMANCE MATRIX (NFRC SIZE) 1" GLAZING WITH ALUMINUM PRESSURE PLATE Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.87 0.46 0.86 0.44 0.85 0.42 0.84 0.40 0.83 0.38 0.82 0.36 0.81 0.34 0.80 0.32 0.79 0.30 0.78 0.28 0.77 0.26 0.76 0.24 0.76 0.22 0.75 0.20 0.74 1600 SystemTM1 with GLASSventTM Projecting (Awning - Single) NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 39 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1500mm wide by 600mm high (59-1/16" by 23-5/8"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.46 0.75 0.42 0.70 0.43 0.70 0.39 0.65 0.41 0.65 0.36 0.60 0.38 0.60 0.33 0.55 0.35 0.55 0.30 0.50 0.32 0.50 0.28 0.45 0.30 0.45 0.25 0.40 0.27 0.40 0.22 0.35 0.24 0.35 0.19 0.30 0.21 0.30 0.17 0.25 0.18 0.25 0.14 0.20 0.16 0.20 0.11 0.15 0.13 0.15 0.08 0.10 0.10 0.10 0.06 0.05 0.07 0.05 0.03 ADMD010 1600 Wall SystemTM1 Curtain Wall 40 DECEMBER, 2015 EC 97911-086 THERMAL CHARTS Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. 1" GLAZING WITH FIBERGLASS PRESSURE PLATE COG U-factor 0.48 (2.72) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier. ADMD010 kawneer.com © Kawneer Company, Inc., 2014 System U-Factor (Btu/h·ft2·°F) Vision Area / Total Area (%) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System U-Factor for Vision Glass © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.45 0.40 0.35 kawneer.com System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2015 1600 Wall SystemTM1 Curtain Wall EC 97911-086 0.30 0.25 0.20 0.15 0.10 0.05 Charts are generated per AAMA 507. ADMD010 41 THERMAL CHARTS 1" GLAZING WITH FIBERGLASS PRESSURE PLATE System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area Vision Area / Total Area (%) COG SHGC 0.75 0.70 0.65 0.60 0.55 0.50 0.30 0.25 0.20 0.15 0.10 0.05 Charts are generated per AAMA 507. THERMAL CHARTS System Visible Transmittance (VT) vs Percent of Vision Area Vision Ares / Total Area (%) COG VT 0.75 0.70 0.65 0.60 0.55 0.50 0.40 0.35 ADMD010 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 Wall SystemTM1 Curtain Wall kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.45 System VT 42 DECEMBER, 2015 EC 97911-086 1" GLAZING WITH FIBERGLASS PRESSURE PLATE 1600 Wall SystemTM1 Curtain Wall DECEMBER, 2015 EC 97911-086 THERMAL PERFORMANCE MATRIX (NFRC SIZE) 1" GLAZING WITH FIBERGLASS PRESSURE PLATE Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.56 0.46 0.54 0.44 0.52 0.42 0.51 0.40 0.49 0.38 0.48 0.36 0.46 0.34 0.44 0.32 0.43 0.30 0.41 0.28 0.39 0.26 0.38 0.24 0.36 0.22 0.34 0.20 0.33 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 43 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.68 0.75 0.67 0.70 0.64 0.70 0.63 0.65 0.59 0.65 0.58 0.60 0.55 0.60 0.54 0.55 0.50 0.55 0.49 0.50 0.46 0.50 0.45 0.45 0.41 0.45 0.40 0.40 0.37 0.40 0.36 0.35 0.32 0.35 0.31 0.30 0.28 0.30 0.27 0.25 0.23 0.25 0.22 0.20 0.19 0.20 0.18 0.15 0.15 0.15 0.13 0.10 0.10 0.10 0.09 0.05 0.06 0.05 0.04 ADMD010 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 Wall SystemTM1 Curtain Wall BLANK PAGE ADMD010 kawneer.com © Kawneer Company, Inc., 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 44 DECEMBER, 2015 EC 97911-086