1600 Wall System1 Curtain Wall

1600 Wall System 1 / System 2
®
®
Imposing Statements –
Used Together
Or Independently
Knight Oil Tools Corporate Facility, Lafayette, LA
Architect: Donald J. Breaux Architect, Lafayette, LA
Glazing Contractor: Advantage Glass & Mirror, New Iberia, LA, with
installation assistance from DeGeorge Glass Company, Inc., Metairie, LA
Building on the proven success of Kawneer's 1600 Wall System®
which set the standards for curtain wall engineering, 1600 Wall
System®1 and 1600 Wall System®2 provide reliability with versatile
features. Both are stick-fabricated, pressure glazed curtain walls for
low-to-mid-rise applications and are designed to be used
independently or as an integrated system to provide visual impact
for almost any type of building.
• 1600 Wall System®1 is an outside glazed, captured curtain wall
• 1600 Wall System®2 is a Structural Silicone Glazed (SSG) curtain wall
Aesthetics
Even the smallest details of 1600 System®1/1600 Wall System®2 reflect
the aesthetics and reliability that derive from Kawneer's precise
engineering and experience. The joinery for both systems is
accomplished with concealed fasteners to create unbroken lines and
a monolithic appearance. When using optional, open back horizontal
mullions, the fillers snap at the edge, producing an uninterrupted
sight line.
Performance
Key aspects of 1600 System®1 and 1600 Wall System®2 are enhanced
for higher performance. Pressure equalization has been designed
into the system and all components are silicone compatible to provide
superior longevity. For installations where severe weather conditions
are prevalent, 1600 Wall System®1 has been large missile hurricane
impact and cycle tested. Proven through years of high performance,
both systems are tested according to industry standards:
Air Performance
Static Water Penetration
Dynamic Water Penetration
Structural Performance
“U” Value, CRF
Sound Transmission Rating
Seismic Performance
ASTM E-283
ASTM E-331
AAMA 501.1
ASTM E-330
AAMA 1503.1
ASTM E 90-90
AAMA 501.4
For the Finishing Touch
Permadonic Anodized finishes are available in Class I and Class II in
seven different colors.
Painted Finishes, including fluoropolymer that meet or exceed
AAMA 2605, are offered in many standard choices and an unlimited
number of specially-designed colors.
Solvent-free powder coatings add the “green” element with high
performance, durability and scratch resistance that meet the
standards of AAMA 2604.
1600 Wall System®2
1600 Wall System®1
1600 Wall System®1/1600 Wall System®2:
• for reliability
• for performance
• for versatility
• for a smooth, monolithic appearance
• for uninterrupted sight lines
Kawneer Company, Inc.
Technology Park / Atlanta
555 Guthridge Court
Norcross, GA 30092
© Kawneer Company, Inc. 2007
kawneer.com
770 . 449 . 5555
LITHO IN U.S.A
Form No. 07-2013
Hunter Henry Center at Mississippi State University,
Mississippi State, MS
Architect: Foil Wyatt Architects & Planners, P.A., Jackson, MS
Glazing Contractor: American Glass Company, Inc., Columbus, MS
DECEMBER, 2015
1600 Wall SystemTM1 Curtain Wall
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
EC 97911-086
1
FEATURES
Features
• 1600 Wall SystemTM1 is an outside glazed captured curtain wall
• 1600 Wall SystemTM1 has a 2-1/2" (63.5) sight line
• Standard 6" (152.4) or 7-1/2" (190.5) depth systems
• Standard infill options 1/4" (6.4) and 1" (25.4), other infills available
• Thermally Broken by means of a continuous 1/4" (6.4) low conductance spacer
• Concealed fastener joinery creates smooth, monolithic appearance
• Open-back horizontals and perimeters are available for cost savings
• Shear block fabrication method
• Corners and splayed mullions available
• Offers integrated entrance framing systems
• Silicone compatible glazing materials for long-lasting seals
• 1600 Wall SystemTM1 has been small and large missile impact and cycle tested
• Two color option
• PermanodicTM anodized finishes in seven choices
• Painted finishes in standard and custom choices
Optional Features
• Steel reinforcing available
• Rain screen and backpans
• Optional deep profile and bull nose covers available
• Deep and heavy-weight mullions available
• Fiberglass pressure plates available
• Veneer system available
• Integrates with standard Kawneer windows and GLASSventTM for curtain wall
• Integrates with VersoleilTM Sunshade Outrigger System and Horizontal or Vertical Single
Blade System
• Integrates with 1600 PowerShadeTM
• Profit$MakerTM plus die sets available
• Hurricane impact resistant framing options: 7-1/16" (179.4), 7-13/16" (198.4), 10-1/16" (255.6)
& 10-13/16" (274.6)
Product Applications
• Ideal for low to mid-rise applications where high performance is desired
• It also is the right choice for high span applications
For specific product applications,
Consult your Kawneer representative.
kawneer.com
ADMD010
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1600 Wall SystemTM1 Curtain Wall
BLANK PAGE
ADMD010
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
2
DECEMBER, 2015
EC 97911-086
DECEMBER, 2015
1600 Wall SystemTM1 Curtain Wall
EC 97911-086
3
INDEX
Architects - Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded
and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be
modified to expand design flexibility. Please contact your Kawneer representative for further assistance.
LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE,
WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE
SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS,
AND ASSUMES NO RESPONSIBILITY THEREFOR.
Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses
(
) are millimeters unless otherwise noted.
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
PICTORIAL VIEW.................................................................................5
1" INFILL DETAILS...............................................................................6
1/4" INFILL DETAILS............................................................................7
ENTRANCE DETAILS.......................................................................8,9
CORNERS...........................................................................................10
SPLAYED MULLION OPTIONS.........................................................11
GLASSventTM FOR CURTAIN WALL/WINDOWS..............................12
BACKPAN AND MISCELLANEOUS DETAILS..................................13
MISCELLANEOUS FRAMING............................................................14
HURRICANE IMPACT RESISTANT DETAILS..............................15,16
ANCHORING.................................................................................17,18
WIND LOAD CHARTS.................................................................. 19-27
DEADLOAD CHARTS.................................................................. 28-30
THERMAL CHARTS .................................................................... 31-43
The following metric (SI ) units are found in these details:
m –meter
cm – centimeter
mm –millimeter
s –second
Pa –pascal
MPa –megapascal
Kawneer reserves the right to change configurations without prior notice when deemed necessary for product
improvement.
kawneer.com
ADMD010
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1600 Wall SystemTM1 Curtain Wall
BLANK PAGE
ADMD010
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
4
DECEMBER, 2015
EC 97911-086
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2015
kawneer.com
1600 Wall SystemTM1 Curtain Wall
EC 97911-086
PICTORIAL VIEW
ADMD010
5
9A
7
1
3
4
7
5
1A
8
8A
6
6A
8
9
ADMD010
2
3
8A
4
9B
OPTIONAL STEEL
REINFORCING
AS REQUIRED
5
6A
6
kawneer.com
© Kawneer Company, Inc., 2014
1" INFILL DETAILS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1600 Wall SystemTM1 Curtain Wall
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
ELEVATION IS NUMBER KEYED TO DETAILS
2-1/2"
(63.5)
9
9A
9B
7-1/2" (190.5)
2
6" (152.4)
6
DECEMBER, 2015
EC 97911-086
SCALE 3" = 1'-0"
1
1A
6" (152.4)
7 -1/2" (190.5)
2-1/2"
(63.5)
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
ELEVATION IS NUMBER KEYED TO DETAILS
7A
kawneer.com
6
2-1/2"
(63.5)
6A
ADMD010
2-1/2"
(63.5)
6 -3/4" (171.5)
7
7A
7B
5-1/4" (133.4)
DECEMBER, 2015
1600 Wall SystemTM1 Curtain Wall
EC 97911-086
1/4" INFILL DETAILS
SCALE 3" = 1'-0"
1
1A
2
1
3
6
6A
4
1A
5
5A
2
5-1/4" (133.4)
6 -3/4" (171.5)
7
3
7B
OPTIONAL STEEL
REINFORCING
AS REQUIRED
4
5A
5
7
1600 Wall SystemTM1 Curtain Wall
8
DECEMBER, 2015
ENTRANCE DETAILS (1" INFILL)
EC 97911-086
SCALE 3" = 1'-0"
1
1A
3
5
2
4
6
TRANSOM BAR
B/H OR O/P
C/H
BUTT HUNG OR
OFFSET PIVOT WITH
SURFACE CLOSER
OR FLOOR CLOSER
B/H OR O/P
ELEVATION IS NUMBER KEYED TO DETAILS
1A
DOOR JAMB
1-15/16"
(88.9)
TYP.
BUTT HUNG OR
OFFSET PIVOT
2
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1
TRANSOM BAR
BUTT HUNG OR OFFSET PIVOT
WITH SINGLE ACTING
CONCEALED OVERHEAD CLOSER
3
CENTER HUNG
4
TRANSOM BAR
CENTER HUNG
CONCEALED OVERHEAD
OR FLOOR CLOSER
DOOR JAMB
BUTT HUNG OR
OFFSET PIVOT
5
6
TRANSOM BAR
BUTT HUNG OR OFFSET PIVOT
WITH LCN CONCEALED
OVER HEAD CLOSER
OR SURFACE CLOSER
ADMD010
kawneer.com
© Kawneer Company, Inc., 2014
DOOR JAMB
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
3/4"
(19)
TYP.
1600 Wall SystemTM1 Curtain Wall
DECEMBER, 2015
EC 97911-086
9
ENTRANCE DETAILS (1/4" INFILL)
SCALE 3" = 1'-0"
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1
1A
3
2
4
B/H OR O/P
1
TRANSOM BAR
C/H
BUTT HUNG OR
OFFSET PIVOT WITH
SURFACE CLOSER
OR FLOOR CLOSER
ELEVATION IS NUMBER KEYED TO DETAILS
DOOR JAMB
BUTT HUNG OR
OFFSET PIVOT
TRANSOM BAR
BUTT HUNG OR OFFSET PIVOT
WITH SINGLE ACTING
CONCEALED OVERHEAD CLOSER
3/4"
(19.1)
TYP.
DOOR JAMB
CENTER HUNG
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1-15/16"
(88.9)
TYP.
2
1A
3
4
TRANSOM BAR
CENTER HUNG
CONCEALED OVERHEAD
OR FLOOR CLOSER
kawneer.com
ADMD010
90° OUTSIDE CORNER
90° INSIDE CORNER
90° OUTSIDE CORNER
135° OUTSIDE CORNER
135° OUTSIDE CORNER
135° INSIDE CORNER
ADMD010
kawneer.com
© Kawneer Company, Inc., 2014
CORNERS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1600 Wall SystemTM1 Curtain Wall
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
10
DECEMBER, 2015
EC 97911-086
SCALE 3" = 1'-0"
NOTE: 1" SYSTEM SHOWN, 1/4" SYSTEM SIMILAR.
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2015
0° TO 5°
0° TO 5°
kawneer.com
1600 Wall SystemTM1 Curtain Wall
EC 97911-086
SPLAYED MULLION OPTIONS
SCALE 3" = 1'-0"
5° TO 15°
5° TO 15°
INSIDE SPLAYED MULLIONS
ADMD010
15° TO 25°
OUTSIDE SPLAYED MULLIONS
15° TO 25°
11
HEAD
SILL
JAMB
8225TL THERMAL WINDOWS
NOTE: Other vent types can be accommodated. Contact your
Kawneer representative for other options.
HEAD
SILL
JAMB
ADMD010
kawneer.com
© Kawneer Company, Inc., 2014
GLASSventTM FOR CURTAIN WALL/WINDOWS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1600 Wall SystemTM1 Curtain Wall
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
12
DECEMBER, 2015
EC 97911-086
SCALE 3" = 1'-0"
GLASSventTM FOR CURTAIN WALL
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
kawneer.com
6
7
3
ELEVATION IS NUMBER KEYED TO DETAILS
NOTE: 6" SYSTEM SHOWN, 7-1/2" SYSTEM SIMILAR
1
JAMB MULLION
AT SPANDREL
(With vapor barrier tie-in)
3
THERMALLY BROKEN
DOOR ADAPTOR
FOR INSULCLAD DOORS
1/2" (12.7)
2
D.L.O.
1
3/8" (9.5)
2-1/2" (63.5)
3/8" (9.5)
D.L.O.
MULLION LENGTH
CONSTRUCTION JOINT
1/2" (12.7) MAX (ALLOWS +/-1/4" MOVEMENT)
5
MULLION LENGTH
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2015
1600 Wall SystemTM1 Curtain Wall
EC 97911-086
BACKPAN AND MISCELLANEOUS DETAILS
SCALE 3" = 1'-0"
4
4
HEAD TRANSOM AT PARAPET FLASHING
5
EXPANSION JOINT
2
6
MULLION AT SPANDREL
TYPICAL DEADLOAD ANCHOR
3
7
AATM 250 THERMAL DOOR
TRANSOM – SPANDREL OVER VISION
ADMD010
13
1600 Wall SystemTM1 Curtain Wall
14
DECEMBER, 2015
MISCELLANEOUS FRAMING
EC 97911-086
SCALE 3" = 1'-0"
3"
(76.2)
2-1/2"
(63.5)
1-1/4"
(31.8)
CAPTURED
MULLION (1")
4-3/4"
(120.7)
2-3/4"
(69.7)
2"
(50.8)
1-3/16"
(30.1)
7-1/2"
(190.5)
6"
(152.4)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Architects – Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and
modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified
to expand design flexibility. Please contact your Kawneer representative for further assistance.
4"
(101.6)
OPTIONAL
FIBERGLASS
PRESSURE PLATE
2-1/2"
(63.5)
OPTIONAL COVERS
4" SIGHT LINE
2-1/2"
(63.5)
DOUBLE MULLION
VENEER SYSTEM
069263
GYPSUM BOARD TRIM
2-1/2"
(63.5)
DEEP MULLION
STOOL TRIM OPTIONS:
069264 - 2-3/4" (69.9)
069265 - 4-1/2" (114.3)
069266 - 5" (127.0)
069267 - 6-1/8" (155.6)
069268 - 6-3/4" (171.4)
NOTE:
STOOL TRIMS REQUIRE 069271 TRIM CLIP PACKAGE
INTERIOR STOOL TRIM
ADMD010
kawneer.com
© Kawneer Company, Inc., 2014
2-1/2"
(63.5)
VARIES
2-1/2"
(63.5)
2-1/2"
(63.5)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
10-1/2"
(266.7)
2-1/2"
(63.5)
1-3/4"
(44.5)
OPTIONAL COVERS
3-19/32"
(91.3)
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
EC 97911-086
SCALE 3" = 1'-0"
5
5A
kawneer.com
7
5
6
8
ELEVATION IS NUMBER KEYED TO DETAILS
EXPANSION
HORIZONTAL
OPTIONAL STEEL
REINFORCING
AS REQUIRED
ADMD010
2-3/4"
(69.9)
2-1/2"
(63.5)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2015
1600 Wall SystemTM1 Curtain Wall
3
10
6
3-19/32"
(91.3)
15
HURRICANE IMPACT RESISTANT DETAILS
NOTE: DETAILS SHOWN WITH 9/16" INFILL AND ARE GLAZED FOR FOR LARGE MISSLE IMPACT (LMI).
SEE NEXT PAGE FOR OTHER GLAZING OPTIONS.
1
2
1
7-1/16"
(179.4)
2
9
4
3
4
7
5A
1600 Wall SystemTM1 Curtain Wall
DECEMBER, 2015
EC 97911-086
HURRICANE IMPACT RESISTANT DETAILS
SCALE 3" = 1'-0"
NOTE: 350 IR DOORS ARE USED WITH IMPACT FRAMING.
DOORS ARE GLAZED WITH 9/16" INFILL.
8
9
7-1/16"
(179.4)
DOOR JAMB
AT MULLION
9/16" INFILL
LARGE MISSILE (LMI)
DOOR JAMB
AT PERIMETER
3/32"
(2.4)
7/8"
(22.2)
3-1/2"
(88.9)
OPTIONAL
10" DEEP SYSTEM
1-5/16" INFILL
LARGE MISSILE (LMI)
2-1/2"
(63.5)
2-1/2"
(63.5)
1-5/16" INFILL
SMALL MISSILE (SMI)
2-1/2"
(63.5)
9/16" INFILL (SMI)
SMALL MISSILE
IMPACT
2-1/2"
(63.5)
GLAZING OPTIONS
7-13/16"
(198.4)
7-1/16"
(179.4)
9/16" INFILL
SMALL MISSILE (SMI)
OVER
9/16" INFILL
LARGE MISSILE (LMI)
1-5/16" INFILL
LARGE MISSILE (LMI)
ADMD010
kawneer.com
© Kawneer Company, Inc., 2014
10
TRANSOM BAR
9/16" INFILL
LARGE MISSILE (LMI)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
3-1/2"
(88.9)
1/8"
(3.2)
10-1/16"
(255.6)
1-3/4"
(44.5)
1/8"
2-1/2"
(63.5)
OPTIONAL
10" DEEP SYSTEM
9/16" INFILL
LARGE MISSILE (LMI)
10-13/16"
(274.6)
2-1/2"
(63.5)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
16
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2015
kawneer.com
1600 Wall SystemTM1 Curtain Wall
EC 97911-086
ANCHORING
Actual project conditions will determine specific anchor design. Details on this page are for reference only.
1" (25.4) MINIMUM
ANCHORING TO FLOOR SLAB
1" (25.4) MINIMUM
ANCHORING TO SUPPORT STEEL
ADMD010
17
1" (25.4) MINIMUM
ANCHORING TO HORIZONTAL
STRUCTURAL STEEL
1" (25.4) MINIMUM
ANCHORING TO VERTICAL
STRUCTURAL STEEL
ADMD010
kawneer.com
© Kawneer Company, Inc., 2014
ANCHORING
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1600 Wall SystemTM1 Curtain Wall
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
18
DECEMBER, 2015
EC 97911-086
Actual project conditions will determine specific anchor design. Details on this page are for reference only.
DECEMBER, 2015
1600 Wall SystemTM1 Curtain Wall
19
WIND LOAD / DEADLOAD CHARTS
EC 97911-086
Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4"
above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress
and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted
curves, in all cases are for the limiting value. Wind load charts contained herein are based upon nominal wind load
utilized in allowable stress design. To convert ultimate wind loads to nominal loads, multiply ultimate wind loads by a
factor of 0.6 per ASCE/SEI 7. A 4/3 increase in allowable stress has not been used to develop these curves. For special
situations not covered by these curves, contact your Kawneer representative for additional information.
DEADLOAD CHARTS
Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an
intermediate horizontal member. The accompanying charts are calculated for 1" (25.4) thick insulating glass or 1/4" (6.4)
thick glass supported on two setting blocks placed at the loading points shown.
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
WIND LOAD CHARTS
kawneer.com
ADMD010
1600 Wall SystemTM1 Curtain Wall
20
DECEMBER, 2015
WIND LOAD CHARTS (1" INFILL)
SINGLE SPAN
1
1.5
2
7
23
TWIN SPAN
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
METERS
.5
EC 97911-086
22
METERS
.5
2
9
28
8.5
27
A
26
5.5
4.5
14
4
13
A
B
3.5
C
10
22
6.5
21
20
D
6
19
E
18
5.5
5
16
E
8
7
C
17
3
D
9
B
23
2.5
7
15
162001
2
4.5
14
4
13
6
0
1
2
3
4
5
6
7
MULLION CENTERS IN FEET
I = 5.035(209.57 x 104)
S = 1.993(32.66 x 103)
8
12
0
1
2
SINGLE SPAN
1
4
5
6
7
8
TWIN SPAN
METERS
METERS
.5
3
MULLION CENTERS IN FEET
1.5
.5
2
7
23
1
1.5
2
30
9
22
29
6.5
20
6
8
26
5.5
A
4
13
B
12
3.5
11
C
10
7.5
24
C
23
7
22
6.5
21
D
20
6
19
E
18
5.5
17
3
D
9
MULLION HEIGHT IN FEET
4.5
14
MULLION HEIGHT
EQUAL
EQUAL
15
METERS
5
6" (152.4)
17
16
B
25
MULLION HEIGHT
18
MULLION HEIGHT IN FEET
8.5
27
19
5
16
E
8
2.5
7
2
15
162002
4.5
14
4
13
6
5
A
28
0
1
2
3
4
5
6
7
MULLION CENTERS IN FEET
8
METERS
21
I = 6.779(282.16 x 104)
S = 2.652(43.46 x 103)
ADMD010
12
0
1
2
3
4
5
6
7
MULLION CENTERS IN FEET
8
kawneer.com
© Kawneer Company, Inc., 2014
11
7.5
24
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
12
MULLION HEIGHT IN FEET
15
METERS
5
16
6" (152.4)
17
MULLION HEIGHT
EQUAL
EQUAL
25
MULLION HEIGHT
18
8
METERS
6
19
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
6.5
20
MULLION HEIGHT IN FEET
1.5
29
21
5
1
30
1600 Wall SystemTM1 Curtain Wall
DECEMBER, 2015
EC 97911-086
WIND LOAD CHARTS (1" INFILL)
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
SINGLE SPAN
METERS
.5
21
1
1.5
2
7
23
TWIN SPAN
METERS
.5
1
1.5
2
30
9
6.5
A
28
8.5
27
6
B
26
19
5.5
4.5
A
14
B
13
4
C
12
3.5
D
11
E
10
MULLION HEIGHT IN FEET
15
METERS
5
16
7-1/2" (190.5)
17
MULLION HEIGHT
EQUAL
EQUAL
25
MULLION HEIGHT
18
8
7.5
C
24
7
23
D
22
6.5
21
E
20
6
19
5.5
18
17
3
5
16
9
2.5
8
15
162003
7
2
1
2
3
4
5
6
7
4.5
14
4
13
6
0
I = 10.135(421.85 x 104)
S = 3.027(49.60 x 103)
8
12
0
1
2
3
4
5
6
7
MULLION CENTERS IN FEET
MULLION CENTERS IN FEET
SINGLE SPAN
TWIN SPAN
METERS
.5
1
METERS
20
5
8
METERS
1.5
.5
2
7
23
1
1.5
2
30
9
29
6.5
21
20
28
6
8
26
5.5
4.5
B
13
4
C
12
D
3.5
11
E
10
MULLION HEIGHT IN FEET
A
14
MULLION HEIGHT
EQUAL
EQUAL
15
METERS
5
7-1/2" (190.5)
17
16
D
25
MULLION HEIGHT
18
MULLION HEIGHT IN FEET
8.5
C
27
19
7.5
E
24
7
23
22
6.5
21
20
6
19
5.5
18
17
3
9
5
16
2.5
8
162004
7
2
15
4.5
14
4
13
6
5
B
0
1
2
3
4
5
6
7
8
I = 12.736(530.11 x 104)
S = 3.791(62.12 x 103)
MULLION CENTERS IN FEET
kawneer.com
12
0
1
2
3
4
5
6
7
MULLION CENTERS IN FEET
ADMD010
8
METERS
22
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
29
21
MULLION HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
22
1600 Wall SystemTM1 Curtain Wall
22
DECEMBER, 2015
WIND LOAD CHARTS (1" INFILL)
SINGLE SPAN
METERS
1
1.5
SINGLE SPAN
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
162004 W/162300
.5
EC 97911-086
2
30
162004 W/162301
METERS
.5
1
1.5
2
30
9
9
28
8.5
25
MULLION HEIGHT
7
23
22
6.5
21
A
20
6
B
19
18
MULLION HEIGHT IN FEET
7.5
24
METERS
5.5
C
17
7.5
24
7
23
22
A
21
6.5
B
20
6
19
C
5.5
18
17
5
16
D
15
4.5
E
14
4
13
0
1
2
3
4
5
6
7
D
16
8
162004
W/162300
162004
W/162301
Ia = 12.736(530.11 x 104)
Sa = 3.791(62.12 x 103)
Is = 3.805(158.37 x 104)
Ss = 1.669(27.35 x 103)
Ia = 12.736(530.11 x 104)
Sa = 3.791(62.12 x 103)
Is = 5.684(236.59 x 104)
Ss = 2.493(40.85 x 103)
5
E
15
4.5
14
4
13
12
0
1
2
3
4
5
6
7
MULLION CENTERS IN FEET
MULLION CENTERS IN FEET
SINGLE SPAN
SINGLE SPAN
162004 W/162301/302
162004 W/162301/302/303
METERS
.5
1
8
METERS
1.5
.5
2
30
1
1.5
2
30
9
9
29
29
28
28
8.5
27
8
26
25
6.5
21
B
6
19
C
18
7-1/2" (190.5)
7
A
22
20
MULLION HEIGHT
24
MULLION HEIGHT IN FEET
7.5
23
8
26
METERS
MULLION HEIGHT IN FEET
25
5.5
17
7.5
24
A
7
23
22
B
21
D
5
E
15
4.5
14
4
13
0
1
2
3
4
5
6
7
8
162004
W/162301/302/303
Ia = 12.736(530.11 x 104)
Sa = 3.791(62.12 x 103)
Is = 7.893(328.53 x 104)
Ss = 3.462(56.73 x 103)
Ia = 12.736(530.11 x 104)
Sa = 3.791(62.12 x 103)
Is = 9.347(389.05 x 104)
Ss = 4.100(67.19 x 103)
MULLION CENTERS IN FEET
6
C
19
5.5
18
D
5
16
162004
W/162301/302
6.5
20
17
16
12
8.5
27
METERS
MULLION HEIGHT IN FEET
25
8
26
METERS
8
26
12
8.5
27
E
15
4.5
14
4
13
12
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
ADMD010
kawneer.com
© Kawneer Company, Inc., 2014
28
27
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
29
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
29
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
MULLION HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
SINGLE SPAN
METERS
12
0
kawneer.com
1
1
2
3
1.5
26
25
23
22
A
21
6.5
20
19
B
18
17
D
16
E
4
5
6
6
C
5.5
15
13
4
7
MULLION CENTERS IN FEET
8
10-1/2" (266.7)
28
MULLION HEIGHT
.5
METERS
DECEMBER, 2015
1600 Wall SystemTM1 Curtain Wall
EC 97911-086
WIND LOAD CHARTS (1" INFILL)
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
2
8.5
27
8
24
7.5
7
5
14
4.5
162064
I = 42.441(1766.52 x 104)
S = 8.816(144.74 x 103)
ADMD010
23
1600 Wall SystemTM1 Curtain Wall
24
DECEMBER, 2015
WIND LOAD CHARTS (1/4" INFILL)
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
SINGLE SPAN
METERS
.5
1
1.5
2
7
23
EC 97911-086
TWIN SPAN
METERS
.5
1
1.5
2
30
9
22
28
5.5
4
13
12
5-1/4" (133.4)
3.5
11
A
10
3
B
9
C
D
8
E
7
2
3
4
5
6
7
7
23
22
B
21
6.5
20
6
19
C
18
5.5
D
16
5
E
15
4.5
14
2
1
7.5
24
17
2.5
162013
6
0
MULLION HEIGHT IN FEET
4.5
14
MULLION HEIGHT
EQUAL
EQUAL
15
METERS
5
16
8
25
17
MULLION HEIGHT
18
MULLION HEIGHT IN FEET
A
26
8
4
13
I = 3.662(152.42 x 104)
S = 1.662(27.24 x 103)
12
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
MULLION CENTERS IN FEET
SINGLE SPAN
TWIN SPAN
METERS
.5
1
METERS
1.5
.5
2
7
23
1
1.5
2
30
9
22
29
6.5
20
28
6
5.5
4
13
12
A
11
3.5
B
10
3
C
9
D
8
2
0
1
2
3
4
5
6
7
8
7
23
C
22
6.5
21
20
6
D
19
E
18
5.5
5
16
2.5
6
7.5
24
17
15
E
7
MULLION HEIGHT IN FEET
4.5
14
MULLION HEIGHT
EQUAL
EQUAL
15
METERS
5
16
5-1/4" (133.4)
17
8
B
25
MULLION HEIGHT
18
MULLION HEIGHT IN FEET
A
26
19
5
8.5
27
METERS
21
4.5
14
162014
I = 4.5071(87.60 x 104)
S = 1.968(32.25 x 103)
MULLION CENTERS IN FEET
4
13
12
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
ADMD010
kawneer.com
© Kawneer Company, Inc., 2014
6
19
5
8.5
27
METERS
20
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
6.5
21
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
29
1600 Wall SystemTM1 Curtain Wall
DECEMBER, 2015
EC 97911-086
WIND LOAD CHARTS (1/4" INFILL)
SINGLE SPAN
.5
1
1.5
2
7
23
TWIN SPAN
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
METERS
METERS
.5
1.5
2
9
29
6.5
20
A
28
8.5
27
6
8
26
19
5.5
13
4
B
12
C
11
3.5
D
10
3
MULLION HEIGHT IN FEET
4.5
A
14
6-3/4" (171.5)
15
METERS
5
16
MULLION HEIGHT
EQUAL
EQUAL
25
17
MULLION HEIGHT
18
2.5
7
162015
3
6.5
20
6
19
D
18
5.5
E
5
4
5
6
7
4.5
14
2
2
C
21
15
6
1
7
22
16
8
0
7.5
23
17
E
9
B
24
8
4
13
I = 7.915(329.45 x 104)
S = 2.635(43.18 x 103)
12
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
MULLION CENTERS IN FEET
SINGLE SPAN
TWIN SPAN
METERS
.5
1
METERS
21
MULLION HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
METERS
1.5
.5
2
7
23
1
1.5
2
30
9
29
6.5
21
20
8.5
B
27
6
8
26
19
5.5
B
13
4
C
12
3.5
11
D
10
3
E
MULLION HEIGHT IN FEET
4.5
A
14
MULLION HEIGHT
EQUAL
EQUAL
15
METERS
5
6-3/4" (171.5)
17
16
C
25
MULLION HEIGHT
18
MULLION HEIGHT IN FEET
A
28
7.5
24
23
7
D
22
6.5
21
E
20
6
19
5.5
18
17
9
5
16
2.5
8
7
2
15
6
162016
13
5
I = 9.594(399.33 x 104)
S = 3.163(51.83 x 103)
12
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
kawneer.com
4.5
14
4
0
1
2
3
4
5
6
7
MULLION CENTERS IN FEET
ADMD010
8
METERS
22
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1
30
22
5
25
1600 Wall SystemTM1 Curtain Wall
26
DECEMBER, 2015
WIND LOAD CHARTS (1/4" INFILL)
SINGLE SPAN
METERS
1
1.5
SINGLE SPAN
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
162016 W/162300
.5
EC 97911-086
2
30
162016 W/162301
METERS
.5
1
1.5
2
30
9
9
28
8.5
25
MULLION HEIGHT
7
23
22
A
21
6.5
20
6
19
B
18
17
5.5
5
4.5
D
E
0
1
2
3
7
23
22
6.5
21
A
20
B
6
19
18
5.5
C
4
4
5
6
7
5
16
14
13
7.5
24
17
C
16
15
MULLION HEIGHT IN FEET
7.5
24
METERS
8
162016
W/162300
162016
W/162301
Ia = 9.594(399.33 x 104)
Sa = 3.163(51.83 x 103)
Is = 3.805(158.37 x 104)
Ss = 1.669(27.35 x 103)
Ia = 9.594(399.33 x 104)
Sa = 3.163(51.83 x 103)
Is = 5.684(236.59 x 104)
Ss = 2.493(40.85 x 103)
D
15
4.5
E
14
4
13
12
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
MULLION CENTERS IN FEET
SINGLE SPAN
SINGLE SPAN
162016 W/162301/302
162016 W/162301/302/303
METERS
.5
1
METERS
1.5
.5
2
30
1
1.5
2
30
9
9
29
29
28
28
8.5
27
8
26
6.5
21
20
B
6
19
18
MULLION HEIGHT IN FEET
7
A
6-3/4" (171.5)
MULLION HEIGHT
24
22
5.5
C
A
25
7.5
23
8
26
METERS
MULLION HEIGHT IN FEET
25
17
7.5
24
7
23
B
22
6.5
21
C
20
6
19
D
15
D
5
E
4.5
14
4
13
0
1
2
3
4
5
6
7
8
5.5
18
17
16
12
8.5
27
E
5
16
162016
W/162301/302
162016
W/162301/302/303
Ia = 9.594(399.33 x 104)
Sa = 3.163(51.83 x 103)
Is = 7.893(328.53 x 104)
Ss = 3.462(56.73 x 103)
Ia = 9.594(399.33 x 104)
Sa = 3.163(51.83 x 103)
Is = 9.347(389.05 x 104)
Ss = 4.100(67.19 x 103)
MULLION CENTERS IN FEET
METERS
MULLION HEIGHT IN FEET
25
8
26
METERS
8
26
12
8.5
27
15
4.5
14
4
13
12
0
1
2
3
4
5
6
7
8
MULLION CENTERS IN FEET
ADMD010
kawneer.com
© Kawneer Company, Inc., 2014
28
27
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
29
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
29
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
MULLION HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
SINGLE SPAN
METERS
12
0
kawneer.com
1
1
2
3
1.5
22
21
20
19
18
17
16
4
5
2
8.5
26
25
23
7
A
6.5
B
6
C
D
5.5
E
15
13
MULLION CENTERS IN FEET
6
7
9-3/4" (247.7)
28
MULLION HEIGHT
.5
METERS
DECEMBER, 2015
1600 Wall SystemTM1 Curtain Wall
EC 97911-086
WIND LOAD CHARTS (1/4" INFILL)
A = 20 PSF (960)
B = 30 PSF (1440)
C = 40 PSF (1920)
D = 50 PSF (2400)
E = 60 PSF (2880)
27
8
24
7.5
5
14
4.5
4
8
I = 36.451(1517.20 x 104)
S = 8.279(135.67 x 103)
162213
ADMD010
27
GLASS HEIGHT IN FEET
0
0
162001
6
5
13
1
2
.5
2
3
4
1
3
4
5
8
7
5
6
1.5
6
METERS
2
13
12
11
10
3
9
8
2.5
7
A
7
9
7
2
B
1.5
4
3
1
2
0.5
1
8
10
A
5
3
2
0
2
12
3.5
11
3
2.5
B
2
6
1.5
4
1
0.5
1
8
0
SPAN IN FEET
ADMD010
.5
METERS
0
0
1
13
1
1
2
METERS
.5
2
3
3
1.5
SPAN IN FEET
SPAN IN FEET
4
162003
1
4
5
7-1/2" (190.5)
7-1/2" (190.5)
5
2
3.5
12
11
3.5
10
9
3
8
2.5
7
6
A
5
6
1.5
7
6
7
9
7
2
B
4
1.5
3
1
2
0.5
10
A
8
B
6
2
5
3
2
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
162002
162004
METERS
2
12
11
3.5
3
2.5
4
1.5
1
1
0.5
SPAN IN FEET
8
kawneer.com
© Kawneer Company, Inc., 2014
1
A - 1/4" GLASS (1/4 POINT LOADING)
B - 1" GLASS (1/4 POINT LOADING)
METERS
DEADLOAD CHARTS (TUBULAR)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0
1.5
GLASS HEIGHT IN FEET
1600 Wall SystemTM1 Curtain Wall
METERS
0
1
GLASS HEIGHT IN FEET
13
.5
METERS
6" (152.4)
METERS
GLASS HEIGHT IN FEET
28
DECEMBER, 2015
EC 97911-086
6" (152.4)
1
8
GLASS HEIGHT IN FEET
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0
kawneer.com
5-1/4" (133.4)
162013
METERS
0
1
13
1
2
.5
2
3
3
4
1
4
5
5
2
6
1.5
9
8
6
13
12
11
A
3
9
8
2.5
7
2
6
5
1.5
4
3
1
2
0.5
1
7
7
8
10
A
7
5
3
2
0
2
12
11
3
2.5
6
2
1.5
4
1
0.5
1
8
0
SPAN IN FEET
ADMD010
.5
0
0
1
13
1
1
2
METERS
.5
2
3
162015
3
1.5
3.5
10
A
8
7
6
2
5
3
2
SPAN IN FEET
SPAN IN FEET
4
1
4
5
6-3/4" (171.5)
6-3/4" (171.5)
SPAN IN FEET
5
6
1.5
9
6
7
3.5
10
A
8
7
6
2
5
1.5
4
3
1
2
1
0.5
7
8
METERS
10
GLASS HEIGHT IN FEET
EC 97911-086
METERS
0
1.5
GLASS HEIGHT IN FEET
0
1
METERS
13
.5
METERS
GLASS HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2015
1600 Wall SystemTM1 Curtain Wall
29
DEADLOAD CHARTS (TUBULAR)
A - 1/4" GLASS (1/4 POINT LOADING)
5-1/4" (133.4)
162014
METERS
2
12
11
3.5
9
3
2.5
4
1.5
1
1
0.5
8
162016
METERS
2
12
11
3.5
3
2.5
1600 Wall SystemTM1 Curtain Wall
DECEMBER, 2015
DEADLOAD CHARTS (OPEN BACK)
A - 1" GLASS (1/8 POINT LOADING)
B - 1" GLASS (1/4 POINT LOADING)
162095
162091
(DOTTED)
1
METERS
1.5
2
10
3
A
8
2.5
7
2
6
B
5
METERS
9
1.5
4
1
3
2
2.5
8
7
B
6
2
5
1.5
4
1
3
2
0.5
1
0
1
2
3
4
5
6
7
1
2
3
4
5
6
7
8
0.5
0
1
2
1
.5
8
METERS
1.5
2
5
1.5
4
1
3
2
0.5
1
9
2.5
B
7
2
6
5
1.5
4
1
3
2
0.5
1
0
7
8
3
9
2.5
8
7
B
6
2
5
1.5
4
1
3
2
0.5
1
0
6
A
10
3
GLASS HEIGHT IN FEET
2
A
8
3.5
11
METERS
B
METERS
2.5
8
GLASS HEIGHT IN FEET
9
2
12
3.5
10
3
1.5
13
11
A
10
1
.5
12
3.5
11
SPAN IN FEET
7
162097
METERS
2
12
5
6
162093
(DOTTED)
13
4
5
6-3/4" (171.5)
162095
162091
(DOTTED)
13
6
4
162078 REINF.
1.5
7
3
A - 1/4" GLASS (1/8 POINT LOADING)
B - 1/4" GLASS (1/4 POINT LOADING)
A - 1" GLASS (1/8 POINT LOADING)
B - 1" GLASS (1/4 POINT LOADING)
METERS
3
1
SPAN IN FEET
162094
162090
(DOTTED)
2
1.5
4
SPAN IN FEET
162077 REINF.
1
5
7-1/2" (190.5)
1
2
B
6
0
6" (152.4)
0
7
1
0
A - 1" GLASS (1/8 POINT LOADING)
B - 1" GLASS (1/4 POINT LOADING)
.5
2.5
8
2
0.5
0
8
3
A
9
3
1
SPAN IN FEET
GLASS HEIGHT IN FEET
10
3
A
9
3.5
11
GLASS HEIGHT IN FEET
10
2
12
3.5
11
GLASS HEIGHT IN FEET
11
1.5
13
METERS
3.5
1
.5
12
12
GLASS HEIGHT IN FEET
METERS
1.5
13
13
0
1
.5
2
0
0
1
2
3
4
5
SPAN IN FEET
ADMD010
6
7
8
0
1
2
3
4
5
6
7
8
SPAN IN FEET
kawneer.com
© Kawneer Company, Inc., 2014
METERS
162096
162092
(DOTTED)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
162094
162090
(DOTTED)
.5
5-1/4" (133.4)
7-1/2" (190.5)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
6" (152.4)
A - 1/4" GLASS (1/8 POINT LOADING)
B - 1/4" GLASS (1/4 POINT LOADING)
METERS
A - 1" GLASS (1/8 POINT LOADING)
B - 1" GLASS (1/4 POINT LOADING)
EC 97911-086
METERS
30
1600 Wall SystemTM1 Curtain Wall
DECEMBER, 2015
EC 97911-086
THERMAL CHARTS
Generic Project Specific U-factor Example Calculation
(Percent of Glass will vary on specific products depending on sitelines)
(Based on single bay of Curtain Wall/Window Wall)
2-1/2" Typ.
4'-0"
3'-0"
D.L.O. D.L.O.
VISION
VISION
6'-0"
D.L.O.
SPANDREL
9'-0"
D.L.O.
31'-3"
8'-0"
D.L.O.
SPANDREL
VISION
5'-0"
D.L.O.
Vision Area
Example Glass U-factor
= 0.48 Btu/(ft2 · h · °F)
Vision Area
= 5(9 + 8 + 4) = 105.0 ft2
Total Area (Vision)
= 5' 2-1/2" (9' 3-3/4" + 8' 2-1/2" + 4' 2-1/2") = 113.2 ft2
Percentage of Vision Glass
= (Vision Area ÷ Total Area)100
= (105.0 ÷ 113.2)100 = 93%
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
2-1/2" Typ.
Spandrel Area
Example Spandrel R-value
= 15 (ft2 · h · °F)/Btu
Spandrel Area
= 5(6 + 3) = 45.0 ft2
Total Area (Spandrel)
= 5' 2-1/2" (6' 2-1/2" + 3' 3-3/4") = 49.6 ft2
Percent of Spandrel
kawneer.com
= (Spandrel Area ÷ Total Area)100
= (45.0 ÷ 49.6)100 = 91%
ADMD010
31
32
1600 Wall SystemTM1 Curtain Wall
DECEMBER, 2015
THERMAL CHARTS
EC 97911-086
Vision Area Chart
System U-factor vs Percent of Vision Area
E IGN
PL S
M E
A D
EX FOR
T
COG
U-factor
0.53
0.50
0.40
0.30
)
0.48
0.46
0.44
0.42
0.40
0.38
0.36
0.34
0.32
0.30
0.28
0.26
0.24
0.22
0.20
0.60
Btu
h·ft 2·°F
System U-factor
O
(N
0.70
93%
0.20
95
85
90
75
80
70
Vision Area / Total Area (%)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
0.80
System U-factor vs Percent of Spandrel Area
Spandrel
R-value
E IGN
PL S
M E
A D
EX FOR
O
0.50
T
3.00
4.00
5.00
0.21
0.20
0.10
91%
95
0.30
)
11.00
15.00
19.00
30.00
0.40
Btu
h·ft 2·°F
System U-factor
(N
2.00
0.60
90
85
80
75
70
Spandrel Area / Total Area (%)
Based on a single curtain wall bay of 91% spandrel and center of
spandrel R-value of 15, system U-factor is equal to 0.21 Btu/(h·ft 2·°F)
ADMD010
kawneer.com
© Kawneer Company, Inc., 2014
Spandrel Area Chart
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Based on a single curtain wall bay of 93% vision glass and center
of glass U-factor of 0.48, System U-factor is equal to 0.53 Btu/(h·ft 2·°F)
DECEMBER, 2015
1600 Wall SystemTM1 Curtain Wall
EC 97911-086
33
THERMAL CHARTS
Note:
Values in parentheses are metric.
COG=Center of Glass.
Charts are generated per AAMA 507.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System U-Factor for Vision Glass
1.30
1.20
(7.00)
1.15
1.10
(6.50)
1.05
(6.00)
1.00
0.95
0.75
0.70
0.65
0.60
COG
U-factor
© Kawneer Company, Inc., 2014
(4.50)
(4.00)
(3.50)
0.55
0.48 (2.73)
0.46 (2.61)
0.44 (2.50)
0.42 (2.39)
0.40 (2.27)
0.38 (2.16)
0.36 (2.05)
0.34 (1.93)
0.32 (1.82)
0.30 (1.71)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
0.50
(3.00)
0.45
(2.50)
0.40
0.35
(2.00)
0.30
0.25
0.20
Vision Area / Total Area (%)
kawneer.com
(5.00)
ADMD010
(1.50)
System U-Factor (W/m2·°C)
0.85
(5.50)
System U-Factor (Btu/h·ft2·°F)
0.90
0.80
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
(7.50)
1.25
0.70
0.65
0.60
0.55
0.50
Spandrel
R-Value
0.45
2.00
0.40
0.35
3.00
0.30
4.00
5.00
0.25
0.20
15.00
19.00
30.00
11.00
95
90
85
80
ADMD010
75
Spandrel Area / Total Area (%)
kawneer.com
© Kawneer Company, Inc., 2014
System U-Factors for Spandrel Glass
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
THERMAL CHARTS
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
1600 Wall SystemTM1 Curtain Wall
System U-Factor (Btu/h·ft2·°F)
34
DECEMBER, 2015
EC 97911-086
Note:
Values in parentheses are metric.
COG=Center of Glass.
Charts are generated per AAMA 507.
0.15
0.10
70
0.05
System VT
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System SHGC
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2015
kawneer.com
1600 Wall SystemTM1 Curtain Wall
EC 97911-086
Vision Ares / Total Area (%)
Charts are generated per AAMA 507.
ADMD010
35
THERMAL CHARTS
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
COG
SHGC
Vision Area / Total Area (%)
Charts are generated per AAMA 507.
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
1600 Wall SystemTM1 Curtain Wall
DECEMBER, 2015
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
0.48
0.61
0.46
0.60
0.44
0.58
0.42
0.56
0.40
0.55
0.38
0.53
0.36
0.51
0.34
0.50
0.32
0.48
0.30
0.47
0.28
0.45
0.26
0.43
0.24
0.42
0.22
0.40
0.20
0.38
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
SHGC Matrix 2
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 2000mm wide by
2000mm high (78-3/4" by 78-3/4").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.69
0.75
0.67
0.70
0.64
0.70
0.63
0.65
0.60
0.65
0.58
0.60
0.55
0.60
0.54
0.55
0.51
0.55
0.49
0.50
0.46
0.50
0.45
0.45
0.42
0.45
0.40
0.40
0.37
0.40
0.36
0.35
0.33
0.35
0.31
0.30
0.28
0.30
0.27
0.25
0.24
0.25
0.22
0.20
0.20
0.20
0.18
0.15
0.15
0.15
0.13
0.10
0.11
0.10
0.09
0.05
0.06
0.05
0.04
ADMD010
kawneer.com
© Kawneer Company, Inc., 2014
Overall U-Factor 4
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1" GLAZING WITH
ALUMINUM PRESSURE PLATE
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Glass U-Factor 3
EC 97911-086
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
36
1600 Wall SystemTM1 Curtain Wall
DECEMBER, 2015
EC 97911-086
37
THERMAL CHARTS
1600 SystemTM1 with GLASSventTM - Projecting (Awning - Single)
Note:
Values in parentheses are metric.
COG = Center of Glass.
Charts are generated per AMMA 507
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System U-Factor for Vision Glass
1.00
(6.00)
0.95
0.90
(5.00)
System U-Factor (Btu/h·ft2·°F)
0.80
(4.50)
0.75
COG
U-factor
0.70
0.48 (2.73)
0.44 (2.50)
0.42 (2.39)
(4.00)
0.65
0.40 (2.27)
0.38 (2.16)
0.36 (2.05)
0.60
0.34 (1.93)
0.32 (1.82)
(3.50)
0.30 (1.71)
0.28 (1.59)
0.55
0.26 (1.48)
0.24 (1.37)
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.46 (2.61)
0.22 (1.25)
0.50
0.20 (1.14)
0.45
Percent of Glass Area = Vision Area/Total Area
Daylight Opening / Projected Area
Notes for System U-factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values and are obtained from your glass supplier.
kawneer.com
ADMD010
(3.00)
System U-Factor (W/m2·°C)
0.85
COG
SHGC
Vision Area / Total Area (%)
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
Vision Area / Total Area (%)
ADMD010
kawneer.com
© Kawneer Company, Inc., 2014
THERMAL CHARTS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System SHGC
1600 Wall SystemTM1 Curtain Wall
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
System VT
38
DECEMBER, 2015
EC 97911-086
1600 SystemTM1 with GLASSventTM - Projecting (Awning - Single)
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
1600 Wall SystemTM1 Curtain Wall
DECEMBER, 2015
EC 97911-086
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
1" GLAZING WITH
ALUMINUM PRESSURE PLATE
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Overall U-Factor 4
0.48
0.87
0.46
0.86
0.44
0.85
0.42
0.84
0.40
0.83
0.38
0.82
0.36
0.81
0.34
0.80
0.32
0.79
0.30
0.78
0.28
0.77
0.26
0.76
0.24
0.76
0.22
0.75
0.20
0.74
1600 SystemTM1 with GLASSventTM Projecting (Awning - Single)
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
SHGC Matrix 2
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Glass U-Factor 3
kawneer.com
39
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1500mm wide by 600mm high (59-1/16" by 23-5/8").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.46
0.75
0.42
0.70
0.43
0.70
0.39
0.65
0.41
0.65
0.36
0.60
0.38
0.60
0.33
0.55
0.35
0.55
0.30
0.50
0.32
0.50
0.28
0.45
0.30
0.45
0.25
0.40
0.27
0.40
0.22
0.35
0.24
0.35
0.19
0.30
0.21
0.30
0.17
0.25
0.18
0.25
0.14
0.20
0.16
0.20
0.11
0.15
0.13
0.15
0.08
0.10
0.10
0.10
0.06
0.05
0.07
0.05
0.03
ADMD010
1600 Wall SystemTM1 Curtain Wall
40
DECEMBER, 2015
EC 97911-086
THERMAL CHARTS
Note:
Values in parentheses are metric.
COG=Center of Glass.
Charts are generated per AAMA 507.
1" GLAZING WITH FIBERGLASS PRESSURE PLATE
COG
U-factor
0.48 (2.72)
0.46 (2.61)
0.44 (2.50)
0.42 (2.39)
0.40 (2.27)
0.38 (2.16)
0.36 (2.05)
0.34 (1.93)
0.32 (1.82)
0.30 (1.71)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)
Notes for System U-Factor, SHGC and VT charts:
For glass values that are not listed, linear interpolation is permitted.
Glass properties are based on center of glass values (winter conditions) and are obtained
from your glass supplier.
ADMD010
kawneer.com
© Kawneer Company, Inc., 2014
System U-Factor (Btu/h·ft2·°F)
Vision Area / Total Area (%)
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
System U-Factor for Vision Glass
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.45
0.40
0.35
kawneer.com
System SHGC
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
DECEMBER, 2015
1600 Wall SystemTM1 Curtain Wall
EC 97911-086
0.30
0.25
0.20
0.15
0.10
0.05
Charts are generated per AAMA 507.
ADMD010
41
THERMAL CHARTS
1" GLAZING WITH FIBERGLASS PRESSURE PLATE
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
Vision Area / Total Area (%)
COG
SHGC
0.75
0.70
0.65
0.60
0.55
0.50
0.30
0.25
0.20
0.15
0.10
0.05
Charts are generated per AAMA 507.
THERMAL CHARTS
System Visible Transmittance (VT) vs Percent of Vision Area
Vision Ares / Total Area (%)
COG
VT
0.75
0.70
0.65
0.60
0.55
0.50
0.40
0.35
ADMD010
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1600 Wall SystemTM1 Curtain Wall
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
0.45
System VT
42
DECEMBER, 2015
EC 97911-086
1" GLAZING WITH FIBERGLASS PRESSURE PLATE
1600 Wall SystemTM1 Curtain Wall
DECEMBER, 2015
EC 97911-086
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
1" GLAZING WITH
FIBERGLASS PRESSURE PLATE
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Overall U-Factor 4
0.48
0.56
0.46
0.54
0.44
0.52
0.42
0.51
0.40
0.49
0.38
0.48
0.36
0.46
0.34
0.44
0.32
0.43
0.30
0.41
0.28
0.39
0.26
0.38
0.24
0.36
0.22
0.34
0.20
0.33
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
SHGC Matrix 2
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
Glass U-Factor 3
kawneer.com
43
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 2000mm wide by
2000mm high (78-3/4" by 78-3/4").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.68
0.75
0.67
0.70
0.64
0.70
0.63
0.65
0.59
0.65
0.58
0.60
0.55
0.60
0.54
0.55
0.50
0.55
0.49
0.50
0.46
0.50
0.45
0.45
0.41
0.45
0.40
0.40
0.37
0.40
0.36
0.35
0.32
0.35
0.31
0.30
0.28
0.30
0.27
0.25
0.23
0.25
0.22
0.20
0.19
0.20
0.18
0.15
0.15
0.15
0.13
0.10
0.10
0.10
0.09
0.05
0.06
0.05
0.04
ADMD010
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely. Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor.
1600 Wall SystemTM1 Curtain Wall
BLANK PAGE
ADMD010
kawneer.com
© Kawneer Company, Inc., 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement.
44
DECEMBER, 2015
EC 97911-086