1600 Wall System 4 ® The Advanced System that Responds to All Your Needs Caesars Palace Tower, Las Vegas, NV Architect: Bergman, Walls and Youngblood Ltd. Architects, Las Vegas, NV Glazing Contractor: Accuracy Glass & Mirror, Inc., Las Vegas, NV The versatile 1600 Wall System®4 offers inside glazing, ease of fabrication, low installation costs, design options and high thermal and structural performance. It is the curtain wall that can accommodate monumental applications, multi-lite punched openings and ribbon windows in both new and remodel construction projects. It is truly a product that has it all. Performance 1600 Wall System®4 incorporates the IsoStrut® Thermal Break at both the vertical mullion and horizontals. This patented method creates a continuous thermal barrier that substantially improves thermal transmission, condensation resistance and structural performance. IsoStrut® achieves a high-strength bond between the aluminum and the thermal isolator. This bond creates a highly composite assembly suitable for use in applications that provide the toughest of thermal and structural tests – monumental curtain walls – as well as multi-lite punched openings and ribbon window applications. For additional economies when the structural performance of IsoStrut® is not required – for example, in ribbon window applications – Kawneer’s IsoLock® Pour and Debridge Thermal Break can be incorporated. Offering superior thermal performance and a singlepiece extrusion, factory-supplied IsoLock® involves pouring liquid urethane into a cavity or thermal pocket, allowing it to harden and cutting away a small section of aluminum opposite the pour area to fully separate the exterior from the interior aluminum. This thermal barrier improves the U-factor and condensation resistance, and means there are fewer parts to cut and assemble. Therefore, less labor is needed and costs are reduced. 1600 Wall System®4 uses the same dry glazing, silicone-compatible exterior and interior gasket as Kawneer’s other 1600 Wall Systems to ensure a positive weather seal and high performance. 1600 Wall System®4 has been tested in accordance with all major standards for curtain walls: Air Infiltration Static Water Penetration Dynamic Water Penetration Thermal Transmittance Structural Performance Seismic Performance ASTM E283 ASTM E331 AAMA 501.2 AAMA 1503.1 ASTM E330 UBC Section No. 2334, (H) 2 (Phase I, Phase II) Economy The IsoStrut® Thermal Break design of 1600 Wall System®4 provides complete mullion assembly with no pressure plates, screws, thermal separators or covers to install. The patented thermal break also reduces the need for steel reinforcing and lowers initial HVAC requirements while reducing ongoing energy costs. Additional labor and cost savings are provided by the ease and speed of sheer block fabrication, coupled with the low installation costs of inside glazing and one-step engagement of snap-on exterior horizontal covers. The system simplifies inventory by utilizing many other 1600 Wall System parts such as SSG verticals, setting blocks, weathering, joint plugs, side blocks and fasteners. 1600 Wall System®4 is offered both as a factory-fabricated and stock-length product to suit project conditions. Caesars Palace Tower, Las Vegas, NV Architect: Bergman, Walls and Youngblood Ltd. Architects, Las Vegas, NV Glazing Contractor: Accuracy Glass & Mirror, Inc., Las Vegas, NV Aesthetics Since the IsoStrut® Thermal Break design in 1600 Wall System®4 comprises two separate aluminum extrusions, designers can select different exterior and interior finishes without exceeding budgets. The 2-1/4" (57.2) face dimension incorporates both a shallow and deep vertical mullion. 1600 Wall System®4 is offered in both a 6" (152.4) and 7-1/2" (190.5) overall frame depth. The system is also offered in an economical ribbon application with a 6" (152.4) frame depth. The horizontal does not use a pressure plate attachment but a conventional retaining leg. The system is designed for a 1" (25.4) infill, with 1/4" (6.4) spandrel glazing accommodated by adapters. Joint connections feature concealed fasteners to give the system smooth, uninterrupted sightlines. 1600 Wall System®4 includes inside and outside 90 and 135 degree corners. For the Finishing Touch Permanodic® Anodized finishes are available in Class I and Class II in seven different color choices. Painted finishes, including fluoropolymer, that meet or exceed AAMA 2605 are offered in many standard choices and an unlimited number of specially-designed colors. Solvent-free powder coatings add the “green” element with high performance, durability and scratch resistance that meet the standards of AAMA 2604. Note: Numbers in parentheses ( ) are millimeters unless otherwise noted. Kawneer Company, Inc. Technology Park / Atlanta 555 Guthridge Court Norcross, GA 30092 © Kawneer Company, Inc. 2007 kawneer.com 770 . 449 . 5555 LITHO IN U.S.A. Form No. 07-2039 1600 WALL SYSTEMTM4 DECEMBER, 2013 EC 97911-053 FEATURES Features • • • • • • • • • • • • • • 1600 Wall SystemTM4 has a narrow 2-1/4" (57.2) sight line Standard 6" (152.4) or 7-1/2" (190.5) depth systems for curtain wall and 6" depth (152.4) depth for ribbon wall IsoStrutTM thermal barrier provides superior structural and thermal performance Integral vertical exterior cover and thermal barrier reduce installed cost Horizontals have removable snap on stops to allow for easy re-glazing from the exterior Standard infill options are 1/8" (3.2), 1/4" (6.4), and 1" (25.4) Concealed fastener joinery creates smooth, monolithic appearance Shear block fabrication method or screw spline option for ribbon windows Standard 90 and 135 degree inside and outside corners available Offers integrated entrance framing systems Peroxide-cure high performance EPDM silicone compatible glazing materials for long lasting seals Two color option PermanodicTM anodized finishes in seven choices Painted finishes in standard and custom choices Optional Features • • • • • Optional pressure plate system Optional IsoLockTM pour and debridge thermal break horizontals Integrates with Kawneer windows and concealed GLASSventTM for curtain wall Steel reinforcing available Profit$MakerTM plus die sets available Product Applications © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. • 1600 Wall SystemTM4 is an inside glazed captured curtain wall and ribbon wall • Ideal for low-rise to high-rise curtain wall applications where inside glazing and high performance is desired or multi-lite punched openings and ribbon windows in both new and remodel construction projects For specific product applications, Consult your Kawneer representative. kawneer.com ADMD040 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 WALL SYSTEMTM4 BLANK PAGE ADMD040 kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 DECEMBER, 2013 EC 97911-053 1600 WALL SYSTEMTM4 DECEMBER, 2013 EC 97911-053 3 INDEX PICTORIAL VIEW.....................................................................................5 1/4 SIZE DETAILS (Typical IsoStrutTM)............................................... 6, 7 1/4 SIZE DETAILS (Pressure Plate Option)....................................... 8, 9 1/4 SIZE DETAILS (Pour and Debridge Horizontal Option).......... 10, 11 ENTRANCE ADAPTERS........................................................................12 CORNERS...............................................................................................12 ANCHORING..........................................................................................13 WIND LOAD CHARTS.......................................................................14,15 DEADLOAD CHARTS.......................................................................16-21 THERMAL CHARTS..........................................................................22-27 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. The following metric (SI) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Architects – Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance. Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADMD040 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 WALL SYSTEMTM4 BLANK PAGE ADMD040 kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 DECEMBER, 2013 EC 97911-053 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2013 kawneer.com 1600 WALL SYSTEMTM4 EC 97911-053 PICTORIAL VIEW ADMD040 5 1/4 SIZE DETAILS (IsoStrut ) 2 3 7 12 8 4 13 9 10 5 NOTE: 6" SYSTEM SHOWN, 7-1/2" SIMILAR. 12 ADMD040 7 1 8 2 OPTIONAL HORIZONTAL 13 11 6 3 ELEVATION IS NUMBER KEYED TO DETAILS 10 4 ALTERNATE JAMB 5 11 6 kawneer.com © Kawneer Company, Inc., 2013 TM Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 WALL SYSTEMTM4 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 6 DECEMBER, 2013 EC 97911-053 SCALE 3" = 1'-0" 1 9 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2013 kawneer.com 1600 WALL SYSTEMTM4 EC 97911-053 SCALE 3" = 1'-0" 1 6 7 6 7 2 3 ELEVATION IS NUMBER KEYED TO DETAILS RIBBON ELEVATION 1 4 2 5 3 7 8 ADMD040 9 7 1/4 SIZE DETAILS (IsoStrutTM) 4 8 5 9 2 3 7 12 8 4 9 10 5 NOTES: 6" SYSTEM SHOWN, 7-1/2" SIMILAR. APPLIED PRESSURE PLATE OPTION SHOWN. 12 13 ADMD040 7 1 8 2 OPTIONAL HORIZONTAL 13 11 6 3 ELEVATION IS NUMBER KEYED TO DETAILS 10 4 5 11 6 kawneer.com © Kawneer Company, Inc., 2013 1/4 SIZE DETAILS (Pressure Plate Option) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 WALL SYSTEMTM4 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 8 DECEMBER, 2013 EC 97911-053 SCALE 3" = 1'-0" 1 9 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2013 kawneer.com 1600 WALL SYSTEMTM4 EC 97911-053 SCALE 3" = 1'-0" 1 6 7 6 7 2 3 ELEVATION IS NUMBER KEYED TO DETAILS RIBBON ELEVATION 1 4 2 5 3 7 8 ADMD040 9 9 1/4 SIZE DETAILS (Pressure Plate Option) 4 8 5 9 2 3 7 12 8 4 13 9 10 5 NOTE: 6" SYSTEM SHOWN, 7-1/2" SIMILAR. 12 ADMD040 7 1 8 2 OPTIONAL HORIZONTAL 13 11 6 3 ELEVATION IS NUMBER KEYED TO DETAILS 10 4 ALTERNATE JAMB 5 11 6 kawneer.com © Kawneer Company, Inc., 2013 1/4 SIZE DETAILS (Pour and Debridge Horizontal Option) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 WALL SYSTEMTM4 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 10 DECEMBER, 2013 EC 97911-053 SCALE 3" = 1'-0" 1 9 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2013 kawneer.com 1600 WALL SYSTEMTM4 EC 97911-053 SCALE 3" = 1'-0" 1 6 7 6 7 2 3 ELEVATION IS NUMBER KEYED TO DETAILS RIBBON ELEVATION 1 4 2 5 3 7 8 ADMD040 9 11 1/4 SIZE DETAILS (Pour and Debridge Horizontal Option) 4 8 5 9 2 3 1 2 1 1 ADMD040 3 ELEVATION IS NUMBER KEYED TO DETAILS NOTE: OFFSET PIVOT/BUTT HUNG ENTRANCE SHOWN. ALSO AVAILABLE FOR CENTER HUNG OUTSIDE 90° CORNER INSIDE 90° CORNER OUTSIDE 135° CORNER INSIDE 135° CORNER kawneer.com © Kawneer Company, Inc., 2013 ENTRANCE ADAPTERS / CORNERS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 WALL SYSTEMTM4 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 12 DECEMBER, 2013 EC 97911-053 SCALE 3" = 1'-0" ENTRANCE ADAPTERS 2 CORNERS © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2013 kawneer.com 1600 WALL SYSTEMTM4 EC 97911-053 ANCHORING ADMD040 13 1600 WALL SYSTEMTM4 14 DECEMBER, 2013 WIND LOAD CHARTS EC 97911-053 Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted curves, in all cases are for the limiting value. If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. (960 Pa) (1440 Pa) (1920 Pa) (2400 Pa) (2880 Pa) SINGLE SPAN SINGLE SPAN METERS METERS 1 1.5 2 .5 15 C 2.5 8 7 D 6 E 2 164200 2 3 4 5 6 7 10 3 9 B C 2.5 8 6 4 8 164204 1.5 1 2 SINGLE SPAN 3 1 4 5 6 7 8 SINGLE SPAN METERS METERS .5 2 MULLION CENTERS IN FEET MULLION HEIGHT MULLION CENTERS IN FEET D E 7 5 1.5 1 A Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. B3 3.5 11 METERS 10 12 MULLION HEIGHT A 9 MULLION HEIGHT IN FEET 3.5 11 4 13 METERS 1.5 2 .5 15 1 1.5 2 15 14 14 A MULLION HEIGHT IN FEET 4 13 B 12 C 10 9 D 8 E 7 3 2.5 METERS 3.5 11 2 6 5 1.5 1 2 3 4 5 6 7 A 13 12 B 3.5 11 C3 D E 2.5 10 9 8 7 2 6 5 164201 4 8 4 METERS MULLION HEIGHT IN FEET 12 5 MULLION HEIGHT IN FEET 2 14 4 13 4 1.5 15 14 4 1 1.5 1 2 3 4 5 6 7 164205 8 MULLION CENTERS IN FEET MULLION CENTERS IN FEET ADMD040 kawneer.com © Kawneer Company, Inc., 2013 .5 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = 20 PSF B = 30 PSF C = 40 PSF D = 50 PSF E = 60 PSF 1600 WALL SYSTEMTM4 DECEMBER, 2013 EC 97911-053 15 WIND LOAD CHARTS A = 20 PSF B = 30 PSF C = 40 PSF D = 50 PSF E = 60 PSF SINGLE SPAN METERS METERS .5 1 1.5 2 .5 15 14 10 METERS A 3 9 B 2.5 8 C 7 D 6 E 2 164250 1.5 1 2 3 4 5 6 7 1.5 MULLION HEIGHT 2 15 4 12 3.5 11 A 10 9 3 B 2.5 8 7 C D 6 E 5 METERS MULLION HEIGHT IN FEET © Kawneer Company, Inc., 2013 14 13 2 164260 1.5 1 2 3 4 5 6 7 A 10 9 8 MULLION CENTERS IN FEET ADMD040 3 B 2.5 8 C 7 D2 E 6 164251 1.5 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET METERS 1 3.5 11 4 SINGLE SPAN .5 12 5 8 MULLION CENTERS IN FEET 4 13 METERS 3.5 11 kawneer.com 2 MULLION HEIGHT MULLION HEIGHT IN FEET 12 4 1.5 14 4 13 4 1 15 5 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. (960 Pa) (1440 Pa) (1920 Pa) (2400 Pa) (2880 Pa) SINGLE SPAN MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted curves, in all cases are for the limiting value. If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. 1600 WALL SYSTEMTM4 16 DECEMBER, 2013 DEADLOAD CHARTS EC 97911-053 Horizontal or deadload limitations are based upon 1/8" maximum deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1/4" and 1" thick glass supported on two setting blocks placed at the loading points shown. 1/4" GLASS 1" GLASS METERS METERS 1.5 .5 2 10 9 2.5 7 2 6 5 1.5 B 4 163208 1 3 GLASS HEIGHT IN FEET 3 8 1 2 .5 3 4 5 6 7 2.5 8 7 2 6 5 1.5 4 B 0 8 .5 A 1 1 2 3 4 5 6 SPAN IN FEET SPAN IN FEET 1/4" GLASS 1" GLASS METERS METERS 1 1.5 1 2 .5 1 3 9 3 A 2 3.5 11 METERS 2 .5 13 1 1.5 7 8 2 13 12 12 3.5 11 10 10 9 7 2 6 5 1.5 B 4 A 3 METERS 2.5 164209 1 2 1 2 3 4 5 6 SPAN IN FEET 7 3 9 2.5 8 7 2 6 5 1.5 B 4 1 3 2 .5 1 GLASS HEIGHT IN FEET 3 8 3.5 11 A .5 1 0 8 ADMD040 METERS GLASS HEIGHT IN FEET 10 GLASS HEIGHT IN FEET 2 12 3.5 11 0 1.5 METERS 12 0 1 13 1 2 3 4 5 6 SPAN IN FEET 7 8 kawneer.com © Kawneer Company, Inc., 2013 1 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. .5 13 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = 1/4 POINT LOADING B = 1/8 POINT LOADING 1600 WALL SYSTEMTM4 DECEMBER, 2013 EC 97911-053 17 DEADLOAD CHARTS Horizontal or deadload limitations are based upon 1/8" maximum deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1/4" and 1" thick glass supported on two setting blocks placed at the loading points shown. 1/4" GLASS 1" GLASS METERS METERS .5 1 1.5 2 .5 12 10 B 6 2 A 5 1.5 4 1 2 1 2 3 4 5 6 7 3 9 2.5 8 7 2 6 5 1.5 4 B 3 .5 1 0 8 1 2 3 6 7 1/4" GLASS 1" GLASS 1 8 METERS 1.5 2 .5 1 1.5 2 13 12 3.5 11 10 10 GLASS HEIGHT IN FEET 3 9 B 7 2 6 5 METERS 2.5 8 1.5 4 A 3 1 2 164209 164009 .5 1 1 2 3 4 5 6 SPAN IN FEET 7 3.5 11 3 9 2.5 8 7 2 6 5 1.5 B 4 A 3 1 2 .5 1 0 8 ADMD040 1 2 3 4 5 6 7 SPAN IN FEET 8 METERS 12 GLASS HEIGHT IN FEET 5 SPAN IN FEET 13 © Kawneer Company, Inc., 2013 4 SPAN IN FEET METERS .5 1 A 2 .5 1 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 164208 164009 GLASS HEIGHT IN FEET 7 METERS 2.5 8 3.5 10 3 3 kawneer.com 2 11 9 0 1.5 12 3.5 11 0 1 13 METERS 13 GLASS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = 1/4 POINT LOADING B = 1/8 POINT LOADING 1600 WALL SYSTEMTM4 18 DECEMBER, 2013 DEADLOAD CHARTS EC 97911-053 Horizontal or deadload limitations are based upon 1/8" maximum deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1/4" and 1" thick glass supported on two setting blocks placed at the loading points shown. 1/4" GLASS 1" GLASS METERS METERS 1.5 2 .5 10 2.5 7 B 6 2 5 1.5 164218 4 A 3 1 2 GLASS HEIGHT IN FEET 3 9 8 1 2 .5 3 4 5 6 7 3 9 2.5 8 7 2 6 5 1.5 4 B 3 .5 1 0 8 1 2 3 4 5 6 SPAN IN FEET SPAN IN FEET 1/4" GLASS 1" GLASS METERS METERS 1 1.5 1 A 2 .5 1 3.5 11 METERS .5 2 1 1.5 7 8 2 13 13 12 12 3.5 11 10 10 9 7 2 6 5 1.5 4 A 3 METERS 2.5 B 164219 1 2 1 2 3 4 5 6 7 SPAN IN FEET 3 9 2.5 8 7 2 6 5 1.5 B 4 A 3 1 2 .5 1 GLASS HEIGHT IN FEET 3 8 3.5 11 .5 1 0 8 ADMD040 METERS GLASS HEIGHT IN FEET 10 GLASS HEIGHT IN FEET 2 12 3.5 11 0 1.5 METERS 12 0 1 13 1 2 3 4 5 6 SPAN IN FEET 7 8 kawneer.com © Kawneer Company, Inc., 2013 1 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. .5 13 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = 1/4 POINT LOADING B = 1/8 POINT LOADING 1600 WALL SYSTEMTM4 DECEMBER, 2013 EC 97911-053 19 DEADLOAD CHARTS Horizontal or deadload limitations are based upon 1/8" maximum deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1/4" and 1" thick glass supported on two setting blocks placed at the loading points shown. 1/4" GLASS 1" GLASS METERS METERS .5 1 1.5 2 .5 13 10 7 2 6 5 METERS 2.5 B 1.5 A 164214 4 1 2 GLASS HEIGHT IN FEET 9 8 1 2 3 4 5 6 7 3 9 2.5 8 7 2 6 B 5 4 1 2 .5 1 0 8 1 2 4 5 6 7 1/4" GLASS 1" GLASS METERS WIDTH IN METERS 1 1.5 2 8 .5 1 1.5 2 13 12 3.5 11 10 10 9 7 2 6 A 5 1.5 4 METERS 2.5 B 164215 1 3 2 1 2 3 4 5 6 SPAN IN FEET 7 3 9 2.5 8 7 2 B 6 A 5 1.5 4 1 3 2 .5 1 HEIGHT IN FEET 3 8 3.5 11 .5 1 0 8 1 2 3 4 5 6 WIDTH IN FEET ADMD040 7 8 HEIGHT IN METERS 12 GLASS HEIGHT IN FEET 3 SPAN IN FEET 13 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SPAN IN FEET .5 1.5 A 3 .5 1 3.5 11 3 3 kawneer.com 2 METERS 10 0 1.5 12 3.5 11 0 1 13 12 GLASS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = 1/4 POINT LOADING B = 1/8 POINT LOADING 1600 WALL SYSTEMTM4 20 DECEMBER, 2013 DEADLOAD CHARTS EC 97911-053 Horizontal or deadload limitations are based upon 1/8" maximum deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1/4" and 1" thick glass supported on two setting blocks placed at the loading points shown. 1" GLASS 1/4" GLASS METERS 1.5 METERS 2 .5 13 10 2.5 7 2 6 5 1.5 B 4 A 3 164253 1 2 1 2 3 4 5 6 SPAN IN FEET 7 2.5 8 7 2 6 5 A .5 1 0 8 1 2 3 4 5 6 SPAN IN FEET 1.5 7 8 1" GLASS METERS 1 1 2 1/4" GLASS .5 1.5 B 4 3 .5 1 3 9 METERS 9 GLASS HEIGHT IN FEET 3 8 3.5 11 METERS METERS 2 .5 13 1 1.5 2 13 12 12 3.5 11 10 10 9 7 2 A 6 5 1.5 METERS 2.5 B 164256 4 1 3 2 1 2 3 4 5 6 SPAN IN FEET 7 3 9 2.5 8 7 2 6 5 1.5 B 4 A 3 1 2 .5 1 GLASS HEIGHT IN FEET 3 8 3.5 11 .5 1 0 8 ADMD040 METERS GLASS HEIGHT IN FEET 10 GLASS HEIGHT IN FEET 2 12 3.5 11 0 1.5 13 12 0 1 1 2 3 4 5 6 SPAN IN FEET 7 8 kawneer.com © Kawneer Company, Inc., 2013 1 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. .5 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = 1/4 POINT LOADING B = 1/8 POINT LOADING 1600 WALL SYSTEMTM4 DECEMBER, 2013 EC 97911-053 21 DEADLOAD CHARTS Horizontal or deadload limitations are based upon 1/8" maximum deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1/4" and 1" thick glass supported on two setting blocks placed at the loading points shown. 1" GLASS 1/4" GLASS METERS .5 1 1.5 METERS 2 .5 10 10 A 2.5 7 2 6 5 METERS 8 1.5 4 164257 1 3 2 3 4 5 6 SPAN IN FEET 7 2.5 8 7 B 6 5 2 1.5 A 4 1 2 .5 1 0 8 © Kawneer Company, Inc., 2013 2 3 9 3 .5 1 GLASS HEIGHT IN FEET 3 9 3.5 11 B 1 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 12 3.5 11 kawneer.com 1.5 13 12 0 1 ADMD040 1 2 3 4 5 6 SPAN IN FEET 7 8 METERS 13 GLASS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = 1/4 POINT LOADING B = 1/8 POINT LOADING 1600 WALL SYSTEMTM4 22 DECEMBER, 2013 THERMAL CHARTS EC 97911-053 Project Specific U-factor Example Calculation (Based on single bay of Curtain Wall/Window Wall) 6'-0" D.L.O. SPANDREL 9'-0" D.L.O. VISION Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 5'-0" D.L.O. Vision Area Example Glass U-factor = 0.48 Btu/(ft2 · h · °F) Vision Area = 5(9 + 8 + 4) = 105.0 ft2 Total Area (Vision) = 5' 2-1/2" (9' 3-3/4" + 8' 2-1/2" + 4' 2-1/2") = 113.2 ft2 Percentage of Vision Glass = (Vision Area ÷ Total Area)100 = (105.0 ÷ 113.2)100 = 93% Spandrel Area Example Spandrel R-value = 15 (ft2 · h · °F)/Btu Spandrel Area = 5(6 + 3) = 45.0 ft2 Total Area (Spandrel) = 5' 2-1/2" (6' 2-1/2" + 3' 3-3/4") = 49.6 ft2 Percent of Spandrel = (Spandrel Area ÷ Total Area)100 = (49.0 ÷ 49.6)100 = 91% ADMD040 kawneer.com © Kawneer Company, Inc., 2013 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. VISION 2-1/2" Typ. 3'-0" D.L.O. 4'-0" D.L.O. VISION 31'-3" SPANDREL 8'-0" D.L.O. 2-1/2" Typ. 1600 WALL SYSTEMTM4 DECEMBER, 2013 EC 97911-053 23 THERMAL CHARTS Vision Area Chart System U-factor vs Percent of Vision Area (N 0.70 E IGN PL S M E A D EX OR F T O COG U-factor 0.53 0.50 0.40 0.30 ) 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.60 Btu h·ft 2·°F System U-factor Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.80 93% 0.20 95 85 90 75 80 70 Vision Area / Total Area (%) Based on a single curtain wall bay of 93% vision glass and center of glass U-factor of 0.48, System U-factor is equal to 0.53 Btu/(h·ft 2·°F) System U-factor vs Percent of Spandrel Area Spandrel R-value E IGN PL S M E A D EX OR F T O 3.00 4.00 © Kawneer Company, Inc., 2013 5.00 0.30 0.21 0.20 0.10 91% 95 0.40 ) 11.00 15.00 19.00 30.00 0.50 Btu h·ft 2·°F System U-factor 2.00 0.60 (N Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Spandrel Area Chart 90 85 80 75 70 Spandrel Area / Total Area (%) Based on a single curtain wall bay of 91% spandrel and center of spandrel R-value of 15, system U-factor is equal to 0.21 Btu/(h·ft 2·°F) kawneer.com ADMD040 System U-Factor for Vision Glass COG U-factor Vision Area / Total Area (%) ADMD040 kawneer.com © Kawneer Company, Inc., 2013 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 WALL SYSTEMTM4 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System U-Factor (Btu/h·ft2·°F) 24 DECEMBER, 2013 EC 97911-053 Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-053 0.55 0.50 Spandrel R-Value kawneer.com 0.45 2.00 95 0.40 0.35 3.00 0.30 4.00 5.00 0.25 0.20 11.00 0.15 15.00 19.00 30.00 0.10 90 85 ADMD040 80 Spandrel Area / Total Area (%) 75 70 0.05 System U-Factor (Btu/h·ft2·°F) DECEMBER, 2013 1600 WALL SYSTEMTM4 THERMAL CHARTS Note: Values in parentheses are metric. COG=Center of Glass. Charts are generated per AAMA 507. System U-Factors for Spandrel Glass 0.70 0.65 0.60 25 COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area COG VT Vision Ares / Total Area (%) Charts are generated per AAMA 507. ADMD040 kawneer.com © Kawneer Company, Inc., 2013 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System SHGC 1600 WALL SYSTEMTM4 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System VT 26 DECEMBER, 2013 EC 97911-053 System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area Charts are generated per AAMA 507. 1600 WALL SYSTEMTM4 DECEMBER, 2013 EC 97911-053 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Glass U-Factor 3 Overall U-Factor 4 0.48 0.57 0.46 0.55 0.44 0.53 0.42 0.52 0.40 0.50 0.38 0.48 0.36 0.47 0.34 0.45 0.32 0.43 0.30 0.42 0.28 0.40 0.26 0.38 0.24 0.37 0.22 0.35 0.20 0.33 SHGC Matrix 2 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.69 0.75 0.68 0.70 0.64 0.70 0.63 0.65 0.60 0.65 0.59 0.60 0.55 0.60 0.54 0.55 0.51 0.55 0.50 0.50 0.46 0.50 0.45 0.45 0.42 0.45 0.41 0.40 0.37 0.40 0.36 0.35 0.33 0.35 0.32 0.30 0.28 0.30 0.27 0.25 0.24 0.25 0.23 0.20 0.19 0.20 0.18 0.15 0.15 0.15 0.14 0.10 0.10 0.10 0.09 0.05 0.06 0.05 0.05 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Thermal Transmittance1 (BTU/h • ft 2 • °F) NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200. 3. Glass properties are based on center of glass values and are obtained from your glass supplier. 4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). kawneer.com ADMD040 27 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1600 WALL SYSTEMTM4 BLANK PAGE ADMD040 kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 28 DECEMBER, 2013 EC 97911-053