FG 623TM SEPTEMBER, 2010 FEATURES EC-97911-21 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Features • • • • • • • • • • • • FG 623TM is an inside glazed system 2-1/4" sight line with standard 6" system depth Optional ISOLOCK® lanced pour and debridged thermal break Screw spline and shear block fabrication and joinery Infill options of 1/4" and 1" Silicone compatible glazing materials for long lasting seals Corner members are available for 90° and 135° applications Incorporates expansion verticals as required FG 623TM has been large missile impact and cycle tested FG 623TM is for stock length sales Permanodic® anodized finishes in 7 choices Painted finishes in standard and custom choices Optional Features Product Applications • Ribbon windows • Ideal for single and multi-lite punched openings © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. • Integrates with standard Kawneer windows For specific product applications, Consult your Kawneer representative. kawneer.com 1 kawneer.com © Kawneer Company, Inc., 2010 BLANK PAGE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. FG 623TM Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 SEPTEMBER, 2010 EC-97911-21 FG 623TM SEPTEMBER, 2010 INDEX EC-97911-21 PICTORIAL VIEW ..................................................................................4 NON-THERMAL FRAMING DETAILS ...................................................5 THERMAL FRAMING DETAILS .............................................................6 CORNER DETAILS . ...............................................................................7 WIND LOAD/DEADLOAD CHARTS . ............................................... 8-12 THERMAL CHARTS........................................................................ 13-16 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. The following metric (SI) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3 Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com kawneer.com © Kawneer Company, Inc., 2010 PICTORIAL VIEW Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. FG 623TM Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 SEPTEMBER, 2010 EC-97911-21 FG 623TM SEPTEMBER, 2010 NON-THERMAL FRAMING DETAILS EC-97911-21 SCALE 3" = 1'-0" 1 5 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 4 2 3 ELEVATION IS NUMBER KEYED TO DETAILS 1/4" SYSTEM 1" SYSTEM 623-306 1 HEAD 623-055 2-1/4" (57.2) 1 HEAD 2-1/4" (57.2) 623-356 623-005 623-054 623-004 6" (1524) 6" (1524) 623-003 623-053 2 INTERMEDIATE HORIZONTAL 2 INTERMEDIATE HORIZONTAL 623-054 623-004 623-013 623-063 3 SILL 3 SILL 071-327 623-010 623-063 623-057 623-065 623-064 kawneer.com 623-010 623-007 623-025 623-024 6" (1524) 2-1/4" (57.2) 4 JAMB 123-302 623-013 6" (1524) © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 5 5 MULLION 2-9/16" (65.1) 5A EXPANSION MULLION 2-1/4" (57.2) 4 JAMB 5 MULLION 2-9/16" (65.1) 5A EXPANSION MULLION THERMAL FRAMING DETAILS 4 2 3 ELEVATION IS NUMBER KEYED TO DETAILS 1" SYSTEM (THERMAL) 623-306 4 JAMB 623-205 623-004 6" (1524) 623-004 623-213 3 SILL 123-302 623-010 623-213 623-207 623-224 623-225 2-1/4" (57.2) 2-9/16" (65.1) 5 MULLION 5A EXPANSION MULLION kawneer.com © Kawneer Company, Inc., 2010 SCALE 3" = 1'-0" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. FG 623TM Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 6" (1524) 1 HEAD 2-1/4" (57.2) 6 SEPTEMBER, 2010 EC-97911-21 1 5 2 INTERMEDIATE HORIZONTAL 623-203 135° INSIDE CORNER 90° INSIDE CORNER 623-123 (623-223) 623-121 (623-221) 1/4" SYSTEM 623-171 623-183 623-173 623-135 623-135 623-187 623-137 623 (62 -123 3-2 23) 623 (62 -121 3-2 21) 623-173 90° OUTSIDE CORNER 3 -12 623 -223) 3 (62 3 -17 623 1 -17 623 623-171 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC-97911-21 1 -12 623 -221) 3 (62 1 -17 kawneer.com 623 3 -17 623 © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SEPTEMBER, 2010 FG 623TM CORNER DETAILS 1" SYSTEM (THERMAL SIMILAR) 623-121 (623-221) 623-131 623-131 623-133 623-123 (623-223) 135° OUTSIDE CORNER 7 FG 623TM WIND LOAD / DEADLOAD CHARTS SEPTEMBER, 2010 EC-97911-21 DEAD LOAD CHARTS Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1" (25) thick insulating glass or 1/4" (6) thick glass supported on two setting blocks placed at the loading points shown. kawneer.com © Kawneer Company, Inc., 2010 Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH and WITHOUT HORIZONTALS and are based on precise engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 p.s.i. (104MPa). Charted curves, in all cases are for the limiting value. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WIND LOAD CHARTS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 8 FG 623TM SEPTEMBER, 2010 WIND LOAD CHARTS EC-97911-21 WITH HORIZONTALS 1.0 1.5 2.0 16 MULLION CENTERS IN METERS 0.5 B 10 3.0 C 9 D 8 2.5 E 7 2.0 6 5 1.5 4 3 2 1 2 3 4 5 6 7 B 11 3.5 C 10 D 3.0 E 9 2.5 8 7 2.0 6 5 1.5 4 1.0 623-057 0.5 I = 9.058 (000000 x 104) S = 2.849 (000000 x 103) 1 A 12 MULLION HEIGHT IN FEET 3.5 MULLION HEIGHT IN METERS 1.0 3 2 0.5 1 0 8 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET MULLION CENTERS IN FEET WITH HORIZONTALS WITHOUT HORIZONTALS MULLION CENTERS IN METERS MULLION CENTERS IN METERS 1.0 1.5 2.0 0.5 16 15 1.5 2.0 15 4.5 14 4.5 14 4.0 A 3.5 11 B 10 3.0 C 9 D 8 2.5 E 7 2.0 6 5 1.5 4 1.0 3 0.5 1 3.5 11 B C 10 D 9 3.0 E 2.5 8 7 2.0 6 5 1.5 4 623-007 1.0 3 I = 8.541 (000000 x 10 ) S = 2.776 (000000 x 103) 4 2 A 12 MULLION HEIGHT IN FEET 12 4.0 13 MULLION HEIGHT IN METERS 13 0 1.0 16 2 0.5 1 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET MULLION HEIGHT IN METERS MULLION HEIGHT IN FEET A 11 4.0 13 MULLION HEIGHT IN METERS 4.0 12 MULLION HEIGHT IN FEET 4.5 14 13 kawneer.com 2.0 15 14 0 1.5 1.0 16 4.5 0.5 © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 15 WITHOUT HORIZONTALS A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) MULLION CENTERS IN METERS 0.5 9 FG 623TM 10 SEPTEMBER, 2010 WIND LOAD CHARTS EC-97911-21 WITH HORIZONTALS A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) MULLION CENTERS IN METERS 0.5 1.0 1.5 2.0 15 4.5 WITHOUT HORIZONTALS MULLION CENTERS IN METERS 0.5 14 4.5 9 C 8 D 7 E 3.0 2.5 2.0 6 5 1.5 4 1.0 3 2 I = 9.058 (000000 x 104) S = 2.849 (000000 x 103) 1 2 3 4 5 6 7 B 10 C D E 9 7 2.0 6 5 1.5 4 1.0 3 0.5 1 0 8 3.0 2.5 8 2 0.5 1 623-207 11 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET MULLION CENTERS IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. B 3.5 MULLION HEIGHT IN FEET 3.5 11 10 A 12 MULLION HEIGHT IN METERS A 4.0 13 MULLION HEIGHT IN METERS 4.0 12 MULLION HEIGHT IN FEET 2.0 14 13 0 1.5 1.0 15 WITH HORIZONTALS 1.0 1.5 2.0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.5 20 6.0 19 5.5 18 5.0 16 15 4.5 14 A 4.0 13 B 12 C 11 3.5 D 10 E 3.0 9 2.5 8 MULLION HEIGHT IN METERS MULLION HEIGHT IN FEET 17 623-024 / 623-025 7 2.0 6 I = 8.541 (000000 x 104) S = 2.776 (000000 x 103) 5 4 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET kawneer.com © Kawneer Company, Inc., 2010 MULLION CENTERS IN METERS FG 623TM SEPTEMBER, 2010 WIND LOAD CHARTS EC-97911-21 WITH HORIZONTALS A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) MULLION CENTERS IN METERS 0.5 1.0 1.5 2.0 20 6.0 5.5 18 5.0 16 15 4.5 14 A 4.0 13 B 12 C 3.5 D 11 10 E 3.0 9 2.5 8 MULLION HEIGHT IN METERS 17 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 19 623-064 / 623-065 7 2.0 I = 9.058 (000000 x 104) S = 2.849 (000000 x 103) 6 5 4 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET WITH HORIZONTALS 0.5 1.5 1.0 2.0 20 6.0 19 5.5 18 5.0 16 15 4.5 14 A 13 4.0 B 12 C D 11 10 E 3.5 3.0 9 2.5 8 623-224 / 623-225 7 2.0 6 5 4 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET kawneer.com MULLION HEIGHT IN METERS MULLION HEIGHT IN FEET 17 © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. MULLION CENTERS IN METERS I = 8.541 (000000 x 104) S = 2.776 (000000 x 103) 11 1.0 0 2 3 1.5 3 2 4 5 2.0 4.5 13 4.0 12 11 3.5 10 9 3.0 8 2.5 7 6 2.0 5 1.5 623-203 B 1.0 A 0.5 6 623-003 4 1 7 WIDTH IN FEET kawneer.com © Kawneer Company, Inc., 2010 DEAD LOAD CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 15 HEIGHT IN METERS FG 623TM Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. HEIGHT IN FEET 12 SEPTEMBER, 2010 EC-97911-21 (1" INFILL) WIDTH IN METERS A = 1/4 POINT LOADING B = 1/8 POINT LOADING 14 FG 623TM SEPTEMBER, 2010 THERMAL CHARTS EC-97911-21 Project Specific U-Factor Example Calculation 15'-8" Frame Width 9'-6" 2'-0" D.L.O. Frame Height 7'-0" D.L.O. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 5'-0" D.L.O. Example Glass U-Factor = 0.42 Btu/hr x ft2 x °F Total Daylight Opening = 3(5' x 7') + 3(5' x 2') = 135 ft2 Total Projected Area = (Total Daylight Opening + Total Area of Framing System) = 15'-8" x 9'-6" = 148.83 ft2 Percent of Glass = (Total Daylight Opening ÷ Total Projected Area) = (135 ÷ 148.83)100 = 91% System U-Factor vs Percent of Glass Area 0.80 0.70 E n PL ig M es A rD EX Fo COG U-Factor 0.60 0.55 0.50 0.45 0.40 0.35 0.30 ) 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 © Kawneer Company, Inc., 2010 0.65 ot (N 0.25 Vision Area / Total Area % Based on 91% glass and center of glass U-Factor of 0.42 System U-Factor is equal to 0.49 Btu/hr x ft2 x °F kawneer.com 70 75 80 85 90 91% 0.20 95 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.75 0.49 13 COG U-Factor 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.50 0.40 0.30 Vision Area / Total Area % Notes for System Y-Factor, Shgc and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are base on center of glass values and are obtained from your glass supplier. kawneer.com Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.70 © Kawneer Company, Inc., 2010 0.60 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. THERMAL CHARTS System U-Factor (Btu/hr x ft2 x °F) FG 623TM 70 75 80 85 90 95 14 SEPTEMBER, 2010 EC-97911-21 System U-Factor vs Percent of Glass Area 0.80 0.20 FG 623TM SEPTEMBER, 2010 15 THERMAL CHARTS EC-97911-21 System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC 0.90 0.90 0.85 0.85 0.80 0.75 0.75 0.70 0.70 0.65 0.65 0.60 0.60 0.55 0.55 0.50 0.50 0.45 0.45 0.40 0.40 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.80 0.15 70 75 80 85 90 95 0.10 Vision Area / Total Area % (Total Daylight Opening / Projected Area) Charts are generated per AAMA 507 COG VT 0.90 0.90 0.85 0.80 0.80 0.75 0.85 0.75 0.70 0.70 0.65 0.65 0.55 0.55 0.50 0.50 0.45 0.45 0.40 0.40 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 0.15 Vision Area / Total Area % (Total Daylight Opening / Projected Area) kawneer.com 70 75 80 85 90 95 0.10 System VT 0.60 0.60 © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Visible Transmittance (VT) vs Percent of Vision Area FG 623TM SEPTEMBER, 2010 THERMAL PERFORMANCE MATRIX (NFRC SIZE) EC-97911-21 Overall U-Factor 4 0.48 0.56 0.46 0.54 0.44 0.52 0.42 0.50 0.40 0.49 0.38 0.47 0.36 0.45 0.34 0.44 0.32 0.42 0.30 0.40 0.28 0.39 0.26 0.37 0.24 0.35 0.22 0.34 0.20 0.32 SHGC Matrix 2 Visible Transmittance 2 Glass SHGC 3 Overall Glass U-Factor 4 Glass VT 3 Overall VT 4 0.90 0.82 0.90 0.80 0.85 0.77 0.85 0.75 0.80 0.73 0.80 0.71 0.75 0.69 0.75 0.66 0.70 0.64 0.70 0.62 0.65 0.60 0.65 0.58 0.60 0.55 0.60 0.53 0.55 0.51 0.55 0.49 0.50 0.46 0.50 0.44 0.45 0.42 0.45 0.40 0.40 0.37 0.40 0.35 0.35 0.33 0.35 0.31 0.30 0.29 0.30 0.27 0.25 0.24 0.25 0.22 0.20 0.20 0.20 0.18 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200. 3. Glass properties are based on center of glass values and are obtained from your glass supplier. 4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). kawneer.com © Kawneer Company, Inc., 2010 Glass U-Factor 3 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Thermal Transmittance1 (BTU/hr • ft 2 • °F) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 16