8400TL Thermal Windows JUNE, 2015 INDEX 8410TL FIXED WINDOW................................................................... 3-6 8430TL SINGLE HUNG WINDOW................................................... 7-12 8450TL DOUBLE HUNG WIDOW.................................................. 13-18 8470TL HORIZONTAL SLIDER..................................................... 19-23 MULLIONS..................................................................................... 24-27 RECEPTORS AND SUB SILLS.......................................................... 28 ANCHORING...................................................................................... 29 THERMAL CHARTS ..................................................................... 30-42 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 1 The following metric (SI ) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADME080 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 8400TL Thermal Windows BLANK PAGE ADME080 kawneer.com © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 JUNE, 2015 EC 97911-075 8400TL Thermal Windows JUNE, 2015 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 8410TL FIXED Features • Architectural Grade Window • Series 8410TL Standard Design • IsoLockTM Thermal Break • Screw and Spline Frame Corner Joinery • Factory Silicone Glazed • Interior Applied Glazing Bead with Bulb Gasket • Architectural Anodized Finishes and Applied Coatings • Two Year Manufacturer's Warranty © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Thermal Break Exterior Fixed Window For specific product applications, Consult your Kawneer representative. kawneer.com ADME080 Interior 3 8400TL Thermal Windows JUNE, 2015 EC 97911-075 Architectural Grade Window F-HC100 / F-AW100 / AW-PG100-FW TESTING STANDARD AAMA / WDMA / CSA 101 / I.S. 2 / A440 (NAFS) FRAME DEPTH 4" Overall Frame Depth TYPICAL WALL THICKNESS .070 Nominal TYPICAL MAXIMUM SIZE 60" x 99" TYPICAL MINIMUM SIZE 12" x 12" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CLASS and GRADE TYPICAL CONFIGURATIONS STANDARD INFILL OPTIONS 1/4", 3/4" with Glazed-in Muntin Grid, 1", and 1-1/2" STANDARD HARDWARE Not Applicable OPTIONAL HARDWARE Not Applicable OTHER OPTIONS Exterior Glazed-in Muntin Grids Exterior Glazing Offset Glazing Perimeters and Sills Exterior Pannings and Interior Trims True Intermediate Mullions Structural Mullions Vertically or Horizontally Stacked PERFORMANCE Air Infiltration Cfm/ft2 Water Resistance PSF Design Load PSF .30 @ 6.24 psf 15 100 Thermal Condensation Sound Transmittance Resistance Transmittance "U" Value CRF STC .60 58 n/a Note: Thermal values are based upon 1" clear insulating glass. ADME080 kawneer.com © Kawneer Company, Inc., 2011 8410TL FIXED Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 © Kawneer Company, Inc., 2011 4" 3/8" Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1-7/8" 3/8" kawneer.com D.L.O 4 JAMB D.L.O 1-15/16" TYPICAL ELEVATION Log onto www.kawneer.com for other configurations W.D. D.L.O O.D. 5 VERTICAL ADME080 1-7/8" 3 D.L.O 5 D.L.O 2 HORIZONTAL 3 SILL 1-15/16" 4 6 D.L.O 1 D.L.O W.D. O.D. 1 HEAD O.D. 1-7/8" 8410TL FIXED WINDOW Standard Design W.D. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 3/8" JUNE, 2015 8400TL Thermal Windows EC 97911-075 8410TL FIXED SCALE : 3" = 1'-0" 4" 2 D.L.O 1-7/8" W.D. O.D. 6 JAMB 3/8" 5 3/8" 1-7/8" 3/8" 1-7/8" D.L.O 5 JAMB 6 3 HORIZONTAL 4 SILL 3/4" 6 APPLIED MUNTIN D.L.O 1-15/16" O.D. W.D. 7 TRUE VERTICAL ADME080 D.L.O 8 D.L.O 2 APPLIED MUNTIN 3/4" 1 3 TYPICAL ELEVATION Log onto www.kawneer.com for other configurations D.L.O W.D. D.L.O O.D. 1-7/8" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1-15/16" 7 W.D. 3/8" 8410TL FIXED WITH GLAZED-IN MUNTIN GRID 1-7/8" O.D. 3/8" 8 JAMB kawneer.com © Kawneer Company, Inc., 2011 4 D.L.O 2 D.L.O 5 1 HEAD O.D. 8410TL FIXED WINDOW with Glazed-in Muntin Grid W.D. 8400TL Thermal Windows Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4" 6 JUNE, 2015 EC 97911-075 SCALE : 3" = 1'-0" 4" 8400TL Thermal Windows JUNE, 2015 8430TL SINGLE HUNG Features • Architectural Grade Window • Series 8430TL Standard Design • IsoLockTM Thermal Break • Screw and Spline Frame and Sash Corner Joinery • Factory Silicone Glazed • Interior Applied Glazing Bead with Bulb Gasket • Architectural Anodized Finishes and Applied Coatings • Two Year Manufacturer's Warranty Thermal Break © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 Exterior Single Hung Window For specific product applications, Consult your Kawneer representative. kawneer.com ADME080 Interior 7 8400TL Thermal Windows JUNE, 2015 8430TL SINGLE HUNG EC 97911-075 Architectural Grade Window H-HC70 / H-AW70 / AW-PG70-H TESTING STANDARD AAMA / WDMA / CSA 101 / I.S. 2 / A440 (NAFS) FRAME DEPTH 4" Overall Frame Depth TYPICAL WALL THICKNESS .070 Nominal TYPICAL MAXIMUM SIZE 60" x 99" TYPICAL MINIMUM SIZE 20" x 33" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CLASS and GRADE TYPICAL CONFIGURATIONS STANDARD INFILL OPTIONS 1/4", 3/4" with Glazed-in Muntin Grid, and 1" STANDARD HARDWARE Heavy Duty Balances Cast White Bronze Sweep Locks OTHER OPTIONS PERFORMANCE Exterior Glazed-in Muntin Grids Perimeters and Sills Exterior Pannings and Interior Trims True Intermediate Mullions Structural Mullions Vertically or Horizontally Stacked Sill for 10 PSF or 15 PSF Water Performance Insect Screens Air Infiltration Cfm/ft2 Water Resistance PSF Design Load PSF .30 @ 6.24 psf 10 / 15 70 Thermal Condensation Sound Transmittance Resistance Transmittance "U" Value CRF STC .70 49 34 Note: Thermal and STC values are based upon 1" clear insulating glass. ADME080 kawneer.com © Kawneer Company, Inc., 2011 OPTIONAL HARDWARE Aluminum Auto Lock Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 8 3/8" © Kawneer Company, Inc., 2011 3/8" 4" kawneer.com W.D. D.L.O D.L.O TYPICAL ELEVATION Log onto www.kawneer.com for other configurations D.L.O O.D. W.D. O.D. 4 JAMB 5 JAMB ADME080 3 SILL 10 PSF 4" 3/8" O.D. D.L.O 5 D.L.O 2-7/8" 2 HORIZONTAL 3-3/4" D.L.O D.L.O 1-11/16" W.D. O.D. 1 HEAD W.D. 3/8" 8430TL SINGLE HUNG WINDOW Standard Design 4-7/8" 3/8" 1 O.D. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 W.D. 4" Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. JUNE, 2015 8400TL Thermal Windows 8430TL SINGLE HUNG SCALE : 3" = 1'-0" 4" 4 2 3 3A SILL 15 PSF 9 O.D. TYPICAL ELEVATION Log onto www.kawneer.com for other configurations 4" 3/8" D.L.O 5 JAMB 3/4" O.D. W.D. 6 APPLIED MUNTIN D.L.O W.D. O.D. 7 JAMB ADME080 7 3 HORIZONTAL 2-7/8" D.L.O 3/4" 2 APPLIED MUNTIN 3 D.L.O 1-11/16" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. D.L.O 2 3-3/4" D.L.O O.D. 3/8" 8430TL SINGLE HUNG WITH GLAZED-IN MUNTIN GRID 4A SILL 15 PSF 4" 3/8" kawneer.com © Kawneer Company, Inc., 2011 4 SILL 10 PSF W.D. 8400TL Thermal Windows Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 O.D. 6 W.D. 5 1 HEAD 4-7/8" D.L.O 3/8" 1 W.D. 8430TL SINGLE HUNG WINDOW with Glazed-in Muntin Grid 3/8" 4" 10 JUNE, 2015 EC 97911-075 SCALE : 3" = 1'-0" 4" 8400TL Thermal Windows JUNE, 2015 8430TL SINGLE HUNG HEAVY DUTY BLOCK AND TACKLE BALANCES Heavy duty balances are concealed in the left and right jambs. Balances are sized according to sash dimensions and sash weight. STANDARD SWEEP LOCK Cast white bronze sweep locks and keepers secure the operating sash at the center meeting rails. ALUMINUM AUTO LOCK Aluminum auto locks are integral to the sash lift rail and used in lieu of cast white bronze auto locks. These locks are used in conjunction with sweep locks for additional security. © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 11 kawneer.com ADME080 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 8400TL Thermal Windows BLANK PAGE ADME080 kawneer.com © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 12 JUNE, 2015 EC 97911-075 8400TL Thermal Windows JUNE, 2015 8450TL DOUBLE HUNG Features • Architectural Grade Window • Series 8450TL Standard Design • IsoLockTM Thermal Break • Screw and Spline Frame and Sash Corner Joinery • Factory Silicone Glazed • Interior Applied Glazing Bead with Bulb Gasket • Architectural Anodized Finishes and Applied Coatings • Two Year Manufacturer's Warranty Thermal Break © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 Exterior Double Hung Window For specific product applications, Consult your Kawneer representative. kawneer.com ADME080 Interior 13 8400TL Thermal Windows JUNE, 2015 8450TL DOUBLE HUNG EC 97911-075 Architectural Grade Window H-HC70 / H-AW70 / AW-PG70-H TESTING STANDARD AAMA / WDMA / CSA 101 / I.S. 2 / A440 (NAFS) FRAME DEPTH 4" Overall Frame Depth TYPICAL WALL THICKNESS .070 Nominal TYPICAL MAXIMUM SIZE 60" x 99" TYPICAL MINIMUM SIZE 20" x 33" TYPICAL CONFIGURATIONS STANDARD INFILL OPTIONS 1/4", 3/4" with Glazed-in Muntin Grid, and 1" STANDARD HARDWARE Heavy Duty Balances Cast White Bronze Sweep Locks Aluminum Auto Lock (Upper Sash Only) OPTIONAL HARDWARE Aluminum Auto Lock at Sill OTHER OPTIONS Exterior Glazed-in Muntin Grids Perimeters and Sills Exterior Pannings and Interior Trims True Intermediate Mullions Structural Mullions Vertically or Horizontally Stacked Sill for 10 PSF or 15 PSF Water Performance Insect Screens PERFORMANCE Air Infiltration Cfm/ft2 Water Resistance PSF Design Load PSF .30 @ 6.24 psf 10 / 15 70 Thermal Condensation Sound Transmittance Resistance Transmittance "U" Value CRF STC .74 50 33 Note: Thermal and STC values are based upon 1" clear insulating glass. ADME080 kawneer.com © Kawneer Company, Inc., 2011 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CLASS and GRADE Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 14 3/8" © Kawneer Company, Inc., 2011 TYPICAL ELEVATION Log onto www.kawneer.com for other configurations 3/8" 4" kawneer.com W.D. D.L.O D.L.O O.D. W.D. O.D. 4 JAMB 5 JAMB ADME080 4" 3/8" O.D. 3 SILL 10 PSF 3 D.L.O 5 D.L.O 2 HORIZONTAL 2-7/8" 2 D.L.O D.L.O O.D. 3-3/8" W.D. 1 3-3/4" W.D. 3/8" 8450TL DOUBLE HUNG WINDOW Standard Design 4-7/8" D.L.O 3/8" 1 HEAD O.D. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 W.D. 4" Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. JUNE, 2015 8400TL Thermal Windows 4 3A SILL 15 PSF 15 8450TL DOUBLE HUNG SCALE : 3" = 1'-0" 4" O.D. 3/8" 4" 5 JAMB 4 TYPICAL ELEVATION Log onto www.kawneer.com for other configurations W.D. D.L.O 3/4" O.D. 6 APPLIED MUNTIN D.L.O W.D. O.D. 7 JAMB ADME080 O.D. 4 SILL 10 PSF 3 HORIZONTAL 3/4" D.L.O 1 6 3-3/8" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2-7/8" 3 D.L.O 3/8" 8450TL DOUBLE HUNG WITH GLAZED-IN MUNTIN GRID 4A SILL 15 PSF 4" 3/8" kawneer.com © Kawneer Company, Inc., 2011 7 D.L.O O.D. W.D. 8400TL Thermal Windows Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. D.L.O 2 APPLIED MUNTIN 3-3/4" W.D. 2 4-7/8" D.L.O 3/8" 5 1 HEAD W.D. 8450TL DOUBLE HUNG WINDOW with Glazed-in Muntin Grid 3/8" 4" 16 JUNE, 2015 EC 97911-075 SCALE : 3" = 1'-0" 4" 8400TL Thermal Windows JUNE, 2015 8450TL DOUBLE HUNG HEAVY DUTY BLOCK AND TACKLE BALANCES Heavy duty balances are concealed in the left and right jambs. Balances are sized according to sash dimensions and sash weight. STANDARD SWEEP LOCK Cast white bronze sweep locks and keepers secure the operating sash at the center meeting rails. ALUMINUM AUTO LOCK Aluminum auto locks are integral to the sash lift rail and used in lieu of cast white bronze auto locks. These locks are used in conjunction with sweep locks for additional security. © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 17 kawneer.com ADME080 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 8400TL Thermal Windows BLANK PAGE ADME080 kawneer.com © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 18 JUNE, 2015 EC 97911-075 8400TL Thermal Windows JUNE, 2015 8470TL HORIZONTAL SLIDER Features • Architectural Grade Window • Series 8470TL Standard Design • IsoLockTM Thermal Break • Screw and Spline Frame and Sash Corner Joinery • Factory Silicone Glazed • Interior Applied Glazing Bead with Bulb Gasket • Architectural Anodized Finishes and Applied Coatings • Two Year Manufacturer's Warranty Thermal Break Exterior © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 Horizontal Sliding Window For specific product applications, Consult your Kawneer representative. kawneer.com ADME080 Interior 19 8400TL Thermal Windows JUNE, 2015 EC 97911-075 Architectural Grade Window HS-HC70 / HS-AW70 / AW-PG70-HS TESTING STANDARD AAMA / WDMA / CSA 101 / I.S. 2 / A440 (NAFS) FRAME DEPTH 4" Overall Frame Depth TYPICAL WALL THICKNESS .070 to .125 Nominal TYPICAL MAXIMUM SIZE 99" x 79" (OX,XO,XX) 148" x 79" (OXO,XOX) 198" x 79" (OXXO) TYPICAL MINIMUM SIZE 32" x 20" (OX,XO,XX) 48" x 20" (OXO,XOX) 64" x 20" (OXXO) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CLASS and GRADE TYPICAL CONFIGURATIONS STANDARD INFILL OPTIONS 1/4", 3/4" with Glazed-in Muntin Grid, and 1" STANDARD HARDWARE Steel Roller Assembly Cast White Bronze Sweep Locks OPTIONAL HARDWARE Aluminum Auto Lock OTHER OPTIONS PERFORMANCE Exterior Glazed-in Muntin Grids Perimeters and Sills Exterior Pannings and Interior Trims True Intermediate Mullions Structural Mullions Vertically or Horizontally Stacked Sill for 10 PSF or 15 PSF Water Performance Insect Screens Standard and Heavy Duty Interlock Air Infiltration Cfm/ft2 Water Resistance PSF Design Load PSF .30 @ 6.24 psf 10 / 15 70 Thermal Condensation Transmittance Resistance "U" Value CRF Sound Transmittance STC .74 51 34 Note: Thermal and STC values are based upon 1" clear insulating glass. ADME080 kawneer.com © Kawneer Company, Inc., 2011 8470TL HORIZONTAL SLIDER Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 20 4" © Kawneer Company, Inc., 2011 3/8" Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. D.L.O 5 6 2 3/8" kawneer.com 4 TYPICAL ELEVATION Log onto www.kawneer.com for other configurations 3-1/8" D.L.O 5 FIXED SASH JAMB D.L.O 2-7/8" W.D. O.D. 6 INTERLOCK ADME080 5-5/8" W.D. O.D. 2 SILL WITH FIXED SASH (10 PSF) 6-9/16" 3/8" D.L.O 1 O.D. 8470TL HORIZONTAL SLIDER Standard Design O.D. D.L.O 3-13/16" W.D. 1 HEAD WITH FIXED SASH W.D. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 3/8" JUNE, 2015 8400TL Thermal Windows EC 97911-075 8470TL HORIZONTAL SLIDER SCALE : 3" = 1'-0" 4" D.L.O 3 HEAD WITH OPERABLE SASH 3 4 SILL WITH OPERABLE SASH (10 PSF) 7 2A SILL WITH FIXED SASH (15 PSF) 4A SILL WITH OPERABLE SASH (15 PSF) D.L.O W.D. 3-1/8" O.D. 7 OPERABLE SASH JAMB 3/8" 21 8400TL Thermal Windows JUNE, 2015 8470TL HORIZONTAL SLIDER WITH GLAZED-IN MUNTIN GRID 9 3-13/16" O.D. W.D. 3/4" D.L.O 3 SILL WITH FIXED SASH (10 PSF) 8 5 APPLIED MUNTIN 3/4" 5 2 APPLIED MUNTIN D.L.O 2 4 HEAD WITH OPERABLE SASH 6 11 SILL WITH OPERABLE SASH (10 PSF) 5-5/8" 4 O.D. 1 1 HEAD WITH FIXED SASH W.D. 8470TL HORIZONTAL SLIDER with Glazed-in Muntin Grid 7 4" 3/8" SCALE : 3" = 1'-0" EC 97911-075 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 22 3-1/8" 3/8" D.L.O D.L.O W.D. 2-7/8" D.L.O O.D. 7 FIXED SASH JAMB 3-1/8" D.L.O 3/4" 3/4" W.D. 3/8" O.D. 8 APPLIED MUNTIN 9 INTERLOCK ADME080 10 APPLIED MUNTIN 11 OPERABLE SASH JAMB kawneer.com © Kawneer Company, Inc., 2011 4" 3/8" O.D. TYPICAL ELEVATION Log onto www.kawneer.com for other configurations 6A SILL WITH OPERABLE SASH (15 PSF) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3A SILL WITH FIXED SASH (15 PSF) 6-9/16" 6 W.D. 3 D.L.O 3/8" 10 8400TL Thermal Windows JUNE, 2015 8470TL HORIZONTAL SLIDER STEEL ROLLER ASSEMBLY Steel ball bearing roller and glass filled nylon housing provide smooth and lasting operation. STANDARD SWEEP LOCK Cast white bronze sweep locks and keepers secure the operating sash at the center meeting rails. ALUMINUM AUTO LOCK Aluminum auto locks are integral to the handle rail. These locks are used in conjunction with sweep locks for additional security. © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 23 kawneer.com ADME080 24 8400TL Thermal Windows JUNE, 2015 MULLIONS EC 97911-075 WIND LOAD CHARTS: THESE CHARTS ARE BASED ON A MAXIMUM DEFLECTION OF L\175 AND\OR A MAXIMUM STRESS OF 15,152 PSI (104 MPa). Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = 30 PSF (1436) B = 40 PSF (1915) C = 50 PSF (2394) D = 60 PSF (2874) E = 70 PSF (3352) MULLION CENTERS IN METERS 1.0 2.0 MULLION HEIGHT IN FEET 9 8 7 2.0 6 5 4 A 1.0 B C D E 3 2 1 MULLION HEIGHT IN METERS 3.0 10 VERTICAL MULLION 245319 0 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET MULLION CENTERS IN METERS 1.0 2.0 MULLION HEIGHT IN FEET 9 8 7 A B 2.0 C D E 6 5 4 1.0 3 2 1 MULLION HEIGHT IN METERS 3.0 10 8410 FIXED WINDOW 245343 245310 0 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET WITH HORIZONTALS ADME080 kawneer.com © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. WITH HORIZONTALS 8400TL Thermal Windows JUNE, 2015 EC 97911-075 MULLIONS WIND LOAD CHARTS: THESE CHARTS ARE BASED ON A MAXIMUM DEFLECTION OF L\175 AND\OR A MAXIMUM STRESS OF 15,152 PSI (104 MPa). Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = 30 PSF (1436) B = 40 PSF (1915) C = 50 PSF (2394) D = 60 PSF (2874) E = 70 PSF (3352) MULLION CENTERS IN METERS 1.0 2.0 MULLION HEIGHT IN FEET 9 8 A B C 2.0 D E 7 6 5 4 1.0 3 2 1 MULLION HEIGHT IN METERS 3.0 10 8430 SINGLE HUNG 8450 DOUBLE HUNG 245238 245239 0 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET MULLION CENTERS IN METERS 1.0 2.0 MULLION HEIGHT IN FEET 9 8 7 A B 2.0 C D E 6 5 4 1.0 3 2 1 MULLION HEIGHT IN METERS 3.0 10 © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. WITH HORIZONTALS 245268 0 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET WITH HORIZONTALS kawneer.com 8470 HORIZONTAL SLIDER ADME080 245269 25 26 8400TL Thermal Windows JUNE, 2015 EC 97911-075 MULLIONS WIND LOAD CHARTS: THESE CHARTS ARE BASED ON A MAXIMUM DEFLECTION OF L\175 AND\OR A MAXIMUM STRESS OF 15,152 PSI (104 MPa). Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A = 30 PSF (1436) B = 40 PSF (1915) C = 50 PSF (2394) D = 60 PSF (2874) E = 70 PSF (3352) MULLION CENTERS IN METERS 1.0 2.0 10 MULLION HEIGHT IN FEET 8 A B C 2.0 D E 7 6 5 4 1.0 3 2 1 MULLION HEIGHT IN METERS 3.0 9 8410 FIXED WINDOW 245287 245310 245310 0 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET MULLION CENTERS IN METERS 1.0 A B C D E 2.0 8 7 6 5 4 1.0 3 2 1 MULLION HEIGHT IN METERS 3.0 9 MULLION HEIGHT IN FEET 8430 SINGLE HUNG 8450 DOUBLE HUNG 2.0 10 0 0 1 2 3 4 5 6 7 245239 8 245287 MULLION CENTERS IN FEET WITH HORIZONTALS ADME080 kawneer.com © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. WITH HORIZONTALS © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 10 1.0 9 kawneer.com 8 A 7 B C 2.0 D E 6 5 3 4 1.0 2 1 0 1 2 3 4 5 6 7 MULLION HEIGHT IN METERS JUNE, 2015 8400TL Thermal Windows EC 97911-075 MULLIONS WIND LOAD CHARTS: THESE CHARTS ARE BASED ON A MAXIMUM DEFLECTION OF L\175 AND\OR A MAXIMUM STRESS OF 15,152 PSI (104 MPa). A = 30 PSF (1436) B = 40 PSF (1915) C = 50 PSF (2394) D = 60 PSF (2874) E = 70 PSF (3352) MULLION CENTERS IN METERS 2.0 3.0 8470 HORIZONTAL SLIDER 0 245269 8 MULLION CENTERS IN FEET WITH HORIZONTALS ADME080 245287 245269 27 4-1/2" 5-1/2" 4-1/2" 345169 HEAD RECEPTOR 4-1/2" FULL DEPTH SILL 260100 260475 4" 260102 260475 5" ADME080 JAMB RECEPTOR 1-9/16" 345368 245201 SUB SILLS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. RECEPTORS AND SUB SILLS 260103 260476 260104 260476 kawneer.com © Kawneer Company, Inc., 2011 3-1/2" 345368 1-9/16" 8400TL Thermal Windows Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1-3/16" 28 JUNE, 2015 EC 97911-075 SCALE : 3" = 1'-0" 4-1/2" 345169 260101 260475 © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JUNE, 2015 kawneer.com 8400TL Thermal Windows EC 97911-075 ANCHORING SCALE : 3" = 1'-0" 245435 PVC PERIMETER (Head and Jamb Similar) 245458 STRAP ANCHOR WITH FIXED WINDOW ADME080 245459 STRAP ANCHOR WITH HUNG WINDOW 29 8400TL Thermal Windows 30 JUNE, 2015 EC 97911-075 BLANK PAGE THERMAL CHARTS Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines) 5'-0" (1524) 51-3/4" (1315) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 3'-0" (915) 27-3/4" (705) Example Glass U-Factor = 0.42 Btu/hr • ft2 • °F Total Daylight Opening = 27-3/4" • 51-3/4" = 9.97ft2 Total Projected Area = 3'-0" • 5'-0" = 15 ft2 Percent of Glass = (Total Daylight Opening ÷ Total Projected Area)100 = (9.97 ÷ 15)100 = 66% System U-factor vs Percent of Glass Area 0.90 (4.50) 0.75 N E IGN PL S M E A D EX OR F T O 0.60 0.55 0.53 0.50 0.45 (3.50) (3.00) W m2 • °C System U-factor (2.73) (2.61) (2.50) (2.39) (2.27) (2.16) (2.05) (1.93) (1.82) (1.71) (1.59) (1.48) (1.37) (1.25) (1.14) (4.00) 0.65 Btu hr • ft2 • °F System U-factor COG U-factor (2.50) 0.40 0.35 (2.00) 0.30 0.25 (1.50) 0.20 75 70 65 66% 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.70 60 55 50 Percent of Glass Area Based on 66% glass and center of glass (COG) U-factor of 0.42 System U-factor is equal to 0.53 Btu/hr • ft2 • °F ADME080 kawneer.com © Kawneer Company, Inc., 2011 0.80 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. (5.00) 0.85 8400TL Thermal Windows JUNE, 2015 EC 97911-075 THERMAL CHARTS FIXED WINDOW WITH 1" GLAZING System U-factor vs Percent of Glass Area Btu hr • ft2 • °F System U-factor COG U-factor 0.48 (2.74) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) 0.18 (1.03) 0.16 (0.91) 0.14 (0.80) 0.12 (0.69) 0.10 (0.57) © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 Percent of Glass Area = Vision Area/Total Area Daylight Opening / Projected Area Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. kawneer.com ADME080 31 COG VT Vision Area / Total Area (%) ADME080 kawneer.com © Kawneer Company, Inc., 2011 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System SHGC 8400TL Thermal Windows Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System VT 32 JUNE, 2015 EC 97911-075 FIXED WINDOW WITH 1" GLAZING System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area 8400TL Thermal Windows JUNE, 2015 EC 97911-075 THERMAL PERFORMANCE MATRIX (NFRC SIZE) FIXED WINDOW WITH 1" GLAZING Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.56 0.46 0.55 0.44 0.54 0.42 0.52 0.40 0.50 0.38 0.49 0.36 0.47 0.34 0.46 0.32 0.44 0.30 0.43 0.28 0.41 0.26 0.39 0.24 0.38 0.22 0.36 0.20 0.35 0.18 0.33 0.16 0.31 0.14 0.29 0.12 0.28 0.10 0.26 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1200mm wide by 1500mm high (47-1/4" by 59-1/16"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.66 0.75 0.65 0.70 0.61 0.70 0.60 0.65 0.57 0.65 0.56 0.60 0.53 0.60 0.52 0.55 0.48 0.55 0.47 0.50 0.44 0.50 0.43 0.45 0.40 0.45 0.39 0.40 0.36 0.40 0.34 0.35 0.31 0.35 0.30 0.30 0.27 0.30 0.26 0.25 0.23 0.25 0.22 0.20 0.18 0.20 0.17 0.15 0.14 0.15 0.13 0.10 0.10 0.10 0.09 0.05 0.05 0.05 0.04 © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 33 ADME080 8400TL Thermal Windows JUNE, 2015 EC 97911-075 THERMAL CHARTS SINGLE HUNG VERTICAL SLIDER WITH 1" GLAZING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 System U-factor vs Percent of Glass Area 0.48 (2.74) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) Percent of Glass Area = Vision Area/Total Area Daylight Opening / Projected Area Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. ADME080 kawneer.com © Kawneer Company, Inc., 2011 COG U-factor Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Btu hr • ft2 • °F System U-factor 34 System VT © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JUNE, 2015 kawneer.com 8400TL Thermal Windows EC 97911-075 Vision Area / Total Area (%) ADME080 35 THERMAL CHARTS SINGLE HUNG VERTICAL SLIDER WITH 1" GLAZING System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area COG VT 8400TL Thermal Windows JUNE, 2015 EC 97911-075 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Overall U-Factor 4 0.48 0.65 0.46 0.64 0.44 0.63 0.42 0.61 0.40 0.60 0.38 0.59 0.36 0.58 0.34 0.56 0.32 0.55 0.30 0.54 0.28 0.53 0.26 0.51 0.24 0.50 0.22 0.49 0.20 0.47 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1200mm wide by 1500mm high (47-1/4" by 59-1/16"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.55 0.75 0.54 0.70 0.51 0.70 0.50 0.65 0.48 0.65 0.46 0.60 0.44 0.60 0.43 0.55 0.41 0.55 0.39 0.50 0.37 0.50 0.36 0.45 0.33 0.45 0.32 0.40 0.30 0.40 0.29 0.35 0.26 0.35 0.25 0.30 0.23 0.30 0.21 0.25 0.19 0.25 0.18 0.20 0.16 0.20 0.14 0.15 0.12 0.15 0.11 0.10 0.08 0.10 0.07 0.05 0.05 0.05 0.04 ADME080 kawneer.com © Kawneer Company, Inc., 2011 Glass U-Factor 3 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE HUNG VERTICAL SLIDER WITH 1" GLAZING Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 36 8400TL Thermal Windows JUNE, 2015 EC 97911-075 THERMAL CHARTS DOUBLE HUNG VERTICAL SLIDER WITH 1" GLAZING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 System U-factor vs Percent of Glass Area Btu hr • ft2 • °F System U-factor COG U-factor 0.48 (2.74) 0.46 (2.61) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.44 (2.50) Percent of Glass Area = Vision Area/Total Area Daylight Opening / Projected Area Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. kawneer.com ADME080 37 COG VT Vision Area / Total Area (%) ADME080 kawneer.com © Kawneer Company, Inc., 2011 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System SHGC 8400TL Thermal Windows Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System VT 38 JUNE, 2015 EC 97911-075 DOUBLE HUNG VERTICAL SLIDER WITH 1" GLAZING System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area 8400TL Thermal Windows JUNE, 2015 EC 97911-075 THERMAL PERFORMANCE MATRIX (NFRC SIZE) DOUBLE HUNG VERTICAL SLIDER WITH 1" GLAZING Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.67 0.46 0.65 0.44 0.64 0.42 0.63 0.40 0.62 0.38 0.60 0.36 0.59 0.34 0.58 0.32 0.57 0.30 0.56 0.28 0.54 0.26 0.53 0.24 0.52 0.22 0.51 0.20 0.49 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1200mm wide by 1500mm high (47-1/4" by 59-1/16"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.53 0.75 0.52 0.70 0.50 0.70 0.48 0.65 0.47 0.65 0.45 0.60 0.43 0.60 0.41 0.55 0.40 0.55 0.38 0.50 0.36 0.50 0.35 0.45 0.33 0.45 0.31 0.40 0.29 0.40 0.28 0.35 0.26 0.35 0.24 0.30 0.22 0.30 0.21 0.25 0.19 0.25 0.17 0.20 0.15 0.20 0.14 0.15 0.12 0.15 0.10 0.10 0.09 0.10 0.07 0.05 0.05 0.05 0.03 © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 39 ADME080 8400TL Thermal Windows JUNE, 2015 EC 97911-075 THERMAL CHARTS HORIZONTAL SLIDER WITH 1" GLAZING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 System U-factor vs Percent of Glass Area COG U-factor 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) Percent of Glass Area = Vision Area/Total Area Daylight Opening / Projected Area Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. ADME080 kawneer.com © Kawneer Company, Inc., 2011 0.48 (2.74) 0.46 (2.61) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Btu hr • ft2 • °F System U-factor 40 System VT © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JUNE, 2015 kawneer.com 8400TL Thermal Windows EC 97911-075 Vision Area / Total Area (%) ADME080 41 THERMAL CHARTS HORIZONTAL SLIDER WITH 1" GLAZING System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area COG VT 8400TL Thermal Windows JUNE, 2015 EC 97911-075 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Overall U-Factor 4 0.48 0.69 0.46 0.68 0.44 0.67 0.42 0.65 0.40 0.64 0.38 0.63 0.36 0.62 0.34 0.61 0.32 0.59 0.30 0.58 0.28 0.57 0.26 0.56 0.24 0.54 0.22 0.53 0.20 0.52 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1500mm wide by 1200mm high (59-1/16" by 47-1/4"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.52 0.75 0.51 0.70 0.49 0.70 0.47 0.65 0.46 0.65 0.44 0.60 0.42 0.60 0.41 0.55 0.39 0.55 0.37 0.50 0.35 0.50 0.34 0.45 0.32 0.45 0.30 0.40 0.29 0.40 0.27 0.35 0.25 0.35 0.24 0.30 0.22 0.30 0.20 0.25 0.18 0.25 0.17 0.20 0.15 0.20 0.14 0.15 0.12 0.15 0.10 0.10 0.08 0.10 0.07 0.05 0.05 0.05 0.03 ADME080 kawneer.com © Kawneer Company, Inc., 2011 Glass U-Factor 3 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. HORIZONTAL SLIDER WITH 1" GLAZING Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 42