8225TL Thermal Windows JUNE, 2015 INDEX FIXED WINDOW................................................................................. 3-6 PROJECT-IN WINDOW.................................................................... 7-10 PROJECT-OUT WINDOW.............................................................. 11-16 INSWING CASEMENT WINDOW.................................................. 17-22 OUTSWING CASEMENT WINDOW.............................................. 23-28 MULLIONS..................................................................................... 29-31 RECEPTORS AND SUB SILLS.......................................................... 32 ANCHORING...................................................................................... 33 THERMAL CHARTS ..................................................................... 34-49 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 1 The following metric (SI ) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADME010 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 8225TL Thermal Windows BLANK PAGE ADME010 kawneer.com © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 JUNE, 2015 EC 97911-075 8225TL Thermal Windows JUNE, 2015 FIXED WINDOW Features • Architectural Grade Window • IsoLock™ Thermal Break • Screw and Spline Frame Corner Joinery • Factory Silicone Glazed • Interior Applied Glazing Bead with Bulb Gasket • Architectural Anodized Finishes and Applied Coatings • Two Year Manufacturer's Warranty Thermal Break Exterior © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 Fixed Window For specific product applications, Consult your Kawneer representative. kawneer.com ADME010 Interior 3 8225TL Thermal Windows JUNE, 2015 EC 97911-075 FIXED WINDOW Architectual Grade AW-PG100-FW TESTING STANDARD AAMA / WDMA / CSA 101 / I.S. 2 / A440 (NAFS) 2-1/4" Overall Frame Depth TYPICAL WALL THICKNESS .090 and .125 Nominal TYPICAL MAXIMUM SIZE 60" x 99" TYPICAL MINIMUM SIZE 12" x 12" TYPICAL CONFIGURATIONS STANDARD INFILL OPTIONS 1/4" and 1" STANDARD HARDWARE Not Applicable OPTIONAL HARDWARE Not Applicable OTHER OPTIONS Unequal Leg Frames Exterior and/or Interior Applied Muntins Perimeters and Sills Exterior Pannings and Interior Trims Structural Mullions Vertically or Horizontally Stacked Access Panels and Blinds Silicone Field Glazing upon Request PERFORMANCE Air Infiltration Cfm/ft2 Water Resistance PSF Design Load PSF Thermal Transmittance "U" Value Condensation Resistance CRF Sound Transmittance STC .10 @ 6.24 psf 15 100 .58 59 34 Note: Thermal values are based upon 1" clear insulating glass. ADME010 kawneer.com © Kawneer Company, Inc., 2011 FRAME DEPTH Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CLASS and GRADE Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 © Kawneer Company, Inc., 2011 2-1/4" Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3/8" 3/8" kawneer.com 4 2 2-1/16" 3 JAMB D.L.O 2-1/2" O.D. W.D. 4 VERTICAL MULLION ADME010 D.L.O O.D. W.D. 5 2 SILL O.D. TYPICAL ELEVATION Log onto www.kawneer.com for other configurations 2-1/16" 3 D.L.O 1 1 HEAD W.D. 2-1/16" 3/8" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JUNE, 2015 8225TL Thermal Windows EC 97911-075 FIXED WINDOW SCALE : 3" = 1'-0" 2-1/4" D.L.O 2-1/16" W.D. O.D. 5 JAMB 3/8" 5 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 8225TL Thermal Windows BLANK PAGE ADME010 kawneer.com © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 6 JUNE, 2015 EC 97911-075 8225TL Thermal Windows JUNE, 2015 PROJECT-IN WINDOW Features • Architectural Grade Window • IsoLock™ Thermal Break • Mitered, Clipped and Staked Vent Corner Joinery • Screw and Spline Frame Corner Joinery • Factory Silicone Glazed • Interior Applied Glazing Bead with Bulb Gasket • Architectural Anodized Finishes and Applied Coatings • Two Year Manufacturer's Warranty • Compatible with Storefront and Curtain Wall Systems Thermal Break Exterior © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 Project-in Window For specific product applications, Consult your Kawneer representative. kawneer.com ADME010 Interior 7 8225TL Thermal Windows JUNE, 2015 EC 97911-075 PROJECT-IN WINDOW Architectual Grade AP-HC90 / AP-AW90 / AP-PG90-AP TESTING STANDARD AAMA / WDMA / CSA 101 / I.S. 2 / A440 (NAFS) FRAME DEPTH 2-1/4" Overall Frame Depth TYPICAL WALL THICKNESS .090 and .125 Nominal TYPICAL MAXIMUM SIZE 60" x 48" TYPICAL MINIMUM SIZE 17" x 17" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CLASS and GRADE TYPICAL CONFIGURATIONS STANDARD INFILL OPTIONS 1/4" and 1" STANDARD HARDWARE Stainless Steel 4-Bar Hinges Cast White Bronze Cam Locks OTHER OPTIONS Unequal Leg Frames Exterior and/or Interior Applied Muntins Insect Screens Perimeters and Sills Exterior Pannings and Interior Trims Structural Mullions Vertically or Horizontally Stacked Access Panels and Blinds Silicone Field Glazing upon Request PERFORMANCE Air Infiltration Cfm/ft2 Water Resistance PSF Design Load PSF Thermal Transmittance "U" Value Condensation Resistance CRF Sound Transmittance STC .10 @ 6.24 psf 15 90 .62 56 n/a Note: Thermal values are based upon 1" clear insulating glass. ADME010 kawneer.com © Kawneer Company, Inc., 2011 OPTIONAL HARDWARE Access Control Locks Limit Stop Pole and Pole Ring Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 8 © Kawneer Company, Inc., 2011 2-1/4" Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3/8" 3 3/8" 3-1/2" kawneer.com D.L.O 4 2 TYPICAL ELEVATION Log onto www.kawneer.com for other configurations D.L.O O.D. W.D. W.D. O.D. 3 JAMB 4 JAMB ADME010 2 SILL 3-1/2" 3/8" 3-1/2" 3-1/2" W.D. 3/8" EC 97911-075 W.D. O.D. D.L.O 1 1 HEAD O.D. D.L.O Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JUNE, 2015 8225TL Thermal Windows PROJECT-IN WINDOW SCALE : 3" = 1'-0" 2-1/4" 9 8225TL Thermal Windows JUNE, 2015 A standard hinge for ventilators providing approximately 45° to 60° openings depending on size. An optional limit stop is available to restrict hinge travel and limit vent opening. STANDARD CAM HANDLE Cast white bronze cam handles are standard for the manual operation and locking of ventilators. CAM HANDLE WITH POLE RING Cast white bronze cam handles with pole ring provide manual operation of ventilators located above reach. These handles are operated with a sash pole. POLE RING Cast white bronze pole ring is used in conjunction with locking hardware for sash pole operation of ventilators. SASH POLE HANGER FOR SASH POLE ACCESS CONTROL LOCK A 3/4" diameter aluminum sash pole with a cast white bronze pull down hook and black rubber tip. Available in 6 ft. and 12 ft. lengths with optional cast white bronze Pole Hanger. In lieu of the standard cam handles cast white bronze access control locks are offered for managed control of vent operations. Lock is operated with a manganese bronze removable handle. ADME010 kawneer.com © Kawneer Company, Inc., 2011 STAINLESS STEEL 4 BAR HINGES Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 PROJECT-IN WINDOW Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 10 8225TL Thermal Windows JUNE, 2015 PROJECT-OUT WINDOW Features • Architectural Grade Window • IsoLock™ Thermal Break • Mitered, Clipped and Staked Vent Corner Joinery • Screw and Spline Frame Corner Joinery • Factory Silicone Glazed • Interior Applied Glazing Bead with Bulb Gasket • Architectural Anodized Finishes and Applied Coatings • Two Year Manufacturer's Warranty • Compatible with Storefront and Curtain Wall Systems Thermal Break Exterior © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 Project-out Window For specific product applications, Consult your Kawneer representative. kawneer.com ADME010 Interior 11 8225TL Thermal Windows JUNE, 2015 EC 97911-075 PROJECT-OUT WINDOW Architectual Grade AP-HC90 / AP-AW90 / AW-PG90-AP TESTING STANDARD AAMA / WDMA / CSA 101 / I.S. 2 / A440 (NAFS) 2-1/4" Overall Frame Depth TYPICAL WALL THICKNESS .090 and .125 Nominal TYPICAL MAXIMUM SIZE 60" x 89" TYPICAL MINIMUM SIZE 17" x 17" TYPICAL CONFIGURATIONS STANDARD INFILL OPTIONS 1/4" and 1" STANDARD HARDWARE Stainless Steel 4-Bar Hinges Cast White Bronze Cam Locks 88SS Support Arm (Units over 50" in height) OPTIONAL HARDWARE Access Control Locks Hook Bolt Lock Handle Pivot Shoe Roto-Operator Scissors Arm Roto-Operator Limit Stop Pole and Pole Ring OTHER OPTIONS Unequal Leg Frames Exterior and/or Interior Applied Muntins Insect Screens Perimeters and Sills Exterior Pannings and Interior Trims Structural Mullions Vertically or Horizontally Stacked Access Panels and Blinds Silicone Field Glazing upon Request PERFORMANCE Air Infiltration Cfm/ft2 Water Resistance PSF Design Load PSF Thermal Transmittance "U" Value Condensation Resistance CRF Sound Transmittance STC .10 @ 6.24 psf 15 90 .60 56 33 Note: Thermal values are based upon 1" clear insulating glass. ADME010 kawneer.com © Kawneer Company, Inc., 2011 FRAME DEPTH Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CLASS and GRADE Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 12 © Kawneer Company, Inc., 2011 2-1/4" Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3/8" D.L.O 3/8" 3-1/2" kawneer.com D.L.O D.L.O 1 2 TYPICAL ELEVATION Log onto www.kawneer.com for other configurations W.D. D.L.O ADME010 3-1/2" O.D. W.D. O.D. 3 JAMB 4 JAMB 3/8" 3-1/2" 3 O.D. O.D. 3-1/2" W.D. 3/8" EC 97911-075 W.D. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JUNE, 2015 8225TL Thermal Windows PROJECT-OUT WINDOW SCALE : 3" = 1'-0" 2-1/4" 1 HEAD 4 2 SILL 13 8225TL Thermal Windows JUNE, 2015 A standard hinge for ventilators providing approximately 45° to 60° openings depending on size. An optional limit stop is available to restrict hinge travel and limit vent opening. STANDARD CAM HANDLE Cast white bronze cam handles are standard for the manual operation and locking of ventilators. CAM HANDLE WITH POLE RING Cast white bronze cam handles with pole ring provide manual operation of ventilators located above reach. These handles are operated with a sash pole. POLE RING Cast white bronze pole ring is used in conjunction with locking hardware for sash pole operation of ventilators. SASH POLE HANGER FOR SASH POLE ACCESS CONTROL LOCK A 3/4" diameter aluminum sash pole with a cast white bronze pull down hook and black rubber tip. Available in 6 ft. and 12 ft. lengths with optional cast white bronze pole hanger. In lieu of the standard cam handles cast white bronze access control locks are offered for managed control of vent operations. Lock is operated with a manganese bronze removable handle. ADME010 kawneer.com © Kawneer Company, Inc., 2011 STAINLESS STEEL 4 BAR HINGES Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 PROJECT-OUT WINDOW Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 14 8225TL Thermal Windows JUNE, 2015 PROJECT-OUT WINDOW PIVOT-SHOE ROTO-OPERATOR Optional pivot shoe roto operator is located on the center line of the bottom horizontal frame. Standard finish shall be brushed copper nickel to match US-25-D. HOOK BOLT LOCK For use with pivot-shoe roto operator in lieu of cam handles. Standard finish shall be US-25-D clear white bronze. 88SS SUPPORT ARM Support arms are used when window height exceeds 50-1/2". When fully extended, the hardware automatically retains the ventilator in an open position. SCISSORS ARM ROTO OPERATOR Optional scissor arm roto operator is located on the center line of the bottom horizontal frame. Standard finish shall be brushed copper nickel to match US-25-D. © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 15 kawneer.com ADME010 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 8225TL Thermal Windows BLANK PAGE ADME010 kawneer.com © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 16 JUNE, 2015 EC 97911-075 8225TL Thermal Windows JUNE, 2015 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 INSWING CASEMENT WINDOW Features • Architectural Grade Window • IsoLock™ Thermal Break • Mitered, Clipped and Staked Vent Corner Joinery • Screw and Spline Frame Corner Joinery • Factory Silicone Glazed • Interior Applied Glazing Bead with Bulb Gasket • Architectural Anodized Finishes and Applied Coatings • Two Year Manufacturer's Warranty • Compatible with Storefront and Curtain Wall Systems Interior Thermal Break © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. HINGED LEFT Exterior Inswing Casement Window For specific product applications, Consult your Kawneer representative. kawneer.com ADME010 17 8225TL Thermal Windows JUNE, 2015 EC 97911-075 INSWING CASEMENT WINDOW Architectual Grade C-HC90 / C-AW90 / AW-PG90-C TESTING STANDARD AAMA / WDMA / CSA 101 / I.S. 2 / A440 (NAFS) FRAME DEPTH 2-1/4" Overall Frame Depth TYPICAL WALL THICKNESS .090 and .125 Nominal TYPICAL MAXIMUM SIZE 36" x 60" TYPICAL MINIMUM SIZE 17" x 17" TYPICAL CONFIGURATIONS STANDARD INFILL OPTIONS 1/4" and 1" STANDARD HARDWARE Stainless Steel 4-Bar Hinges Cast White Bronze Cam Locks OPTIONAL HARDWARE Access Control Locks Limit Stop Pole and Pole Ring Butt Hinges Friction Adjustor Keyed Limit Arm OTHER OPTIONS Unequal Leg Frames Exterior and/or Interior Applied Muntins Insect Screens Perimeters and Sills Exterior Pannings and Interior Trims Structural Mullions Vertically or Horizontally Stacked Access Panels and Blinds Silicone Field Glazing upon Request PERFORMANCE Air Infiltration Cfm/ft2 Water Resistance PSF Design Load PSF Thermal Transmittance "U" Value Condensation Resistance CRF Sound Transmittance STC .10 @ 6.24 psf 15 90 .58 52 n/a Note: Thermal values are based upon 1" clear insulating glass. ADME010 kawneer.com © Kawneer Company, Inc., 2011 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CLASS and GRADE Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 18 © Kawneer Company, Inc., 2011 2-1/4" Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3/8" 2 3/8" kawneer.com 3-1/2" 3 HINGED LEFT 2 SILL 3-1/2" D.L.O W.D. ADME010 O.D. D.L.O O.D. 1 HEAD D.L.O W.D. 3-1/2" 3/8" EC 97911-075 W.D. D.L.O Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JUNE, 2015 8225TL Thermal Windows INSWING CASEMENT WINDOW SCALE : 3" = 1'-0" O.D. W.D. O.D. 3 JAMB 4 JAMB 2-1/4" 1 4 TYPICAL ELEVATION Log onto www.kawneer.com for other configurations 3-1/2" 3/8" 19 8225TL Thermal Windows JUNE, 2015 A standard hinge for ventilators providing approximately 45° to 60° openings depending on size. An optional limit stop is available to restrict hinge travel and limit vent opening. STANDARD CAM HANDLE Cast white bronze cam handles are standard for the manual operation and locking of ventilators. CAM HANDLE WITH POLE RING Cast white bronze cam handles with pole ring provide manual operation of ventilators located above reach. These handles are operated with a sash pole. POLE RING Cast white bronze pole ring is used in conjunction with locking hardware for sash pole operation of ventilators. SASH POLE HANGER FOR SASH POLE ACCESS CONTROL LOCK A 3/4" diameter aluminum sash pole with a cast white bronze pull down hook and black rubber tip. Available in 6 ft. and 12 ft. lengths with optional cast white bronze pole hanger. In lieu of the standard cam handles cast white bronze access control locks are offered for managed control of vent operations. Lock is operated with a manganese bronze removable handle. ADME010 kawneer.com © Kawneer Company, Inc., 2011 STAINLESS STEEL 4 BAR HINGES Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 INSWING CASEMENT WINDOW Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 20 8225TL Thermal Windows JUNE, 2015 INSWING CASEMENT WINDOW BUTT HINGES An optional hinge for ventilators providing a full 90° opening. Butt Hinges shall be finished to match the window. FRICTION ADJUSTOR Friction adjustors shall be used with butt hinges for additional friction for control of the ventilator. KEYED LIMIT ARM Key released limit arms may be used to restrict ventilator opening when used with butt hinges. © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 kawneer.com ADME010 21 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 8225TL Thermal Windows BLANK PAGE ADME010 kawneer.com © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 22 JUNE, 2015 EC 97911-075 8225TL Thermal Windows JUNE, 2015 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 OUTSWING CASEMENT WINDOW Features • Architectural Grade Window • IsoLock™ Thermal Break • Mitered, Clipped and Staked Vent Corner Joinery • Screw and Spline Frame Corner Joinery • Factory Silicone Glazed • Interior Applied Glazing Bead with Bulb Gasket • Architectural Anodized Finishes and Applied Coatings • Two Year Manufacturer's Warranty • Compatible with Storefront and Curtain Wall Systems Thermal Break Interior © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. HINGED LEFT Exterior Outswing Casement Window For specific product applications, Consult your Kawneer representative. kawneer.com ADME010 23 8225TL Thermal Windows JUNE, 2015 EC 97911-075 OUTSWING CASEMENT WINDOW Architectual Grade C-HC90 / C-AW90 / AW-PG90-C TESTING STANDARD AAMA / WDMA / CSA 101 / I.S. 2 / A440 (NAFS) 2-1/4" Overall Frame Depth TYPICAL WALL THICKNESS .090 and .125 Nominal TYPICAL MAXIMUM SIZE 36" x 60" TYPICAL MINIMUM SIZE 17" x 17" TYPICAL CONFIGURATIONS STANDARD INFILL OPTIONS 1/4" and 1" STANDARD HARDWARE Stainless Steel 4-Bar Hinges Cast White Bronze Cam Locks OPTIONAL HARDWARE Butt Hinges Access Control Locks Hook Bolt Lock or Multi-Point Lock Limit Stop Pole and Pole Ring Friction Adjustor Keyed Limit Arm Roto Operator OTHER OPTIONS Unequal Leg Frames Exterior and/or Interior Applied Muntins Insect Screens Perimeters and Sills Exterior Pannings and Interior Trims Structural Mullions Vertically or Horizontally Stacked Access Panel and Blinds Silicone Field Glazing upon Request PERFORMANCE Air Infiltration Cfm/ft2 Water Resistance PSF Design Load PSF Thermal Transmittance "U" Value Condensation Resistance CRF Sound Transmittance STC .10 @ 6.24 psf 15 90 .60 50 37 Note: Thermal values are based upon 1" clear insulating glass. ADME010 kawneer.com © Kawneer Company, Inc., 2011 FRAME DEPTH Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. CLASS and GRADE Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 24 © Kawneer Company, Inc., 2011 2-1/4" Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3/8" 3/8" kawneer.com D.L.O 3-1/2" D.L.O HINGED LEFT 2 SILL W.D. D.L.O ADME010 O.D. O.D. 1 HEAD D.L.O 2 O.D. W.D. O.D. 3 JAMB 4 JAMB 3-1/2" W.D. 3/8" EC 97911-075 W.D. 3 3-1/2" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JUNE, 2015 8225TL Thermal Windows OUTSWING CASEMENT WINDOW SCALE : 3" = 1'-0" 2-1/4" 1 4 TYPICAL ELEVATION Log onto www.kawneer.com for other configurations 3-1/2" 3/8" 25 8225TL Thermal Windows JUNE, 2015 A standard hinge for ventilators providing approximately 45° to 60° openings depending on size. An optional limit stop is available to restrict hinge travel and limit vent opening. BUTT HINGES An optional hinge for ventilators providing a full 90° opening. Butt hinges shall be finished to match the window. FRICTION ADJUSTOR Friction adjustors shall be used with butt hinges for additional friction for control of the ventilator. ROTO OPERATOR Roto operators are used with butt hinges only and located at the bottom horizontal frame. Standard finish shall be brushed copper nickel to match US-25-D. STANDARD CAM HANDLE Cast white bronze cam handles are standard for the manual operation and locking of ventilators. CAM HANDLE WITH POLE RING Cast white bronze cam handles with pole ring provide manual operation of ventilators located above reach. These handles are operated with a sash pole. KEYED LIMIT ARM Key released limit arms may be used to restrict ventilator opening when used with butt hinges. ADME010 kawneer.com © Kawneer Company, Inc., 2011 STAINLESS STEEL 4 BAR HINGES Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 OUTSWING CASEMENT WINDOW Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 26 8225TL Thermal Windows JUNE, 2015 EC 97911-075 OUTSWING CASEMENT WINDOW Cast white bronze pole ring is used in conjunction with locking hardware for sash pole operation of ventilators. © Kawneer Company, Inc., 2011 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. POLE RING Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 27 SASH POLE A 3/4" diameter aluminum sash pole with a cast white bronze pull down hook and black rubber tip. Available in 6 ft. and 12 ft. lengths with optional cast white bronze pole hanger. HANGER FOR SASH POLE ACCESS CONTROL LOCK In lieu of the standard cam handles cast white bronze access control locks are offered for managed control of vent operations. Lock is operated with a manganese bronze removable handle. HOOK BOLT LOCK Optional hook bolt lock in lieu of cam handle. Standard finish shall be US-25-D clear white bronze. MULTI-POINT LOCK Optional single locking handle for concealed multi-point locks located on the vertical frame. Standard finish shall be US-25-D clear white bronze. ESCAPE WINDOW SIGN Vinyl escape window sign. Colors are white letters on red background. ESCAPE WINDOW Vinyl rescue window sign with lettering on both sides. Colors are black letters on a yellow background. RESCUE WINDOW SIGN RESCUE WINDOW EMED CO. BUFFALO, N.Y. 1-800-442-3633 QS1848DF kawneer.com ADME010 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 8225TL Thermal Windows BLANK PAGE ADME010 kawneer.com © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 28 JUNE, 2015 EC 97911-075 8225TL Thermal Windows JUNE, 2015 EC 97911-075 MULLIONS WIND LOAD CHARTS: THESE CHARTS ARE BASED ON A MAXIMUM DEFLECTION OF L\175 AND\OR A MAXIMUM STRESS OF 15,152 PSI (104 MPa). MULLION CENTERS IN METERS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.5 1.0 1.5 10 3.0 2.5 8 MULLION HEIGHT IN METERS MULLION HEIGHT IN FEET 9 7 2.0 6 A 5 1.5 B 4 C 1.0 3 D E 2 A = 20 PSF (958) B = 35 PSF (1436) C = 50 PSF (2394) D = 70 PSF (3352) E = 90 PSF (4309) 224131 224133 0.5 1 0 1 2 3 4 5 6 MULLION CENTERS IN FEET MULLION CENTERS IN METERS 0.5 1.0 1.5 10 A = 20 PSF (958) B = 35 PSF (1436) C = 50 PSF (2394) D = 70 PSF (3352) E = 90 PSF (4309) 3.0 2.5 8 7 2.0 6 5 1.5 A 4 1.0 3 B MULLION HEIGHT IN METERS MULLION HEIGHT IN FEET 9 © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. UNITS WITH HORIZONTALS C D 0.5 E 2 1 0 1 2 3 4 5 6 MULLION CENTERS IN FEET UNITS WITH HORIZONTALS kawneer.com ADME010 224138 29 8225TL Thermal Windows 30 JUNE, 2015 EC 97911-075 MULLIONS WIND LOAD CHARTS: THESE CHARTS ARE BASED ON A MAXIMUM DEFLECTION OF L\175 AND\OR A MAXIMUM STRESS OF 15,152 PSI (104 MPa). MULLION CENTERS IN METERS 1.0 1.5 2.0 A = 20 PSF (958) B = 25 PSF (1197) C = 30 PSF (1436) D = 40 PSF (1915) 3.0 2.5 MULLION HEIGHT IN FEET 8 7 2.0 6 A 5 1.5 B C D 4 3 1.0 MULLION HEIGHT IN METERS 9 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.5 10 224070 2 0.5 1 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET UNITS WITH HORIZONTALS 1.5 1.0 2.0 A = 30 PSF (1436) B = 45 PSF (2155) C = 60 PSF (2873) D = 75 PSF (3591) E = 90 PSF (4309) 12 3.5 3.0 9 2.5 8 7 A 2.0 6 B C 1.5 5 D 4 MULLION HEIGHT IN METERS MULLION HEIGHT IN FEET 11 10 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.5 13 224071 E 1.0 3 2 0.5 1 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET UNITS WITH HORIZONTALS ADME010 kawneer.com © Kawneer Company, Inc., 2011 MULLION CENTERS IN METERS 8225TL Thermal Windows JUNE, 2015 EC 97911-075 MULLIONS WIND LOAD CHARTS: THESE CHARTS ARE BASED ON A MAXIMUM DEFLECTION OF L\175 AND\OR A MAXIMUM STRESS OF 15,152 PSI (104 MPa). MULLION CENTERS IN METERS 1.0 1.5 2.0 A = 20 PSF (958) B = 40 PSF (1915) C = 60 PSF (2873) D = 80 PSF (3830) E = 100 PSF (4788) 13 12 3.5 11 3.0 9 B 2.5 8 7 C 6 2.0 D E 5 1.5 4 MULLION HEIGHT IN METERS A 10 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.5 224072 1.0 3 2 0.5 1 0 1 2 3 4 5 6 7 8 UNITS WITH HORIZONTALS © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. MULLION CENTERS IN FEET NOTE: MULLION PROJECTION TO THE INTERIOR AVAILABLE kawneer.com ADME010 31 3-1/2" (88.9) 325059 224154 1-15/16" (49.2) 260100 5" (127) HEAD RECEPTOR 3" (76.2) 260475 260103 HEAD RECEPTOR 3" (76.2) SCALE : 3" = 1'-0" 3" (76.2) 225150 225425 3-1/8" (79.4) 260101 4" (101.6) 260476 5-1/2" (139.7) ADME010 JAMB RECEPTOR 224154 FULL DEPTH SILLS 225151 225425 4-7/8" (123.8) 3" (76.2) 260475 4-1/2" (114.3) 225152 6-7/16" (163.5) 325059 JAMB RECEPTOR 224154 UNEQUAL LEG SILLS 260102 260475 260104 260476 kawneer.com Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. RECEPTORS AND SUB SILLS © Kawneer Company, Inc., 2011 325059 224154 1-15/16" (49.2) 8225TL Thermal Windows Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1-3/4" (44.5) 1-1/8" (28.6) 9/16" (14.3) 32 JUNE, 2015 EC 97911-075 EQUAL LEG SILLS 1-15/16" (49.2) 325059 UNEQUAL LEG SILLS 1-15/16" (49.2) © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JUNE, 2015 kawneer.com 8225TL Thermal Windows 229175 PVC PERIMETER (Continuous) Head and Jamb Similar 225081 225459 STRAP ANCHOR with SEALANT BACK-UP 225552 2-3/4" (69.9) F-ANCHOR STRAP Equal Leg Frame Only ADME010 STRAP ANCHOR with SUB SILL 33 EC 97911-075 SCALE : 3" = 1'-0" 225459 8225TL Thermal Windows 34 JUNE, 2015 EC 97911-075 THERMAL CHARTS Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines) 5'-0" (1524) 51-3/4" (1315) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 3'-0" (915) 27-3/4" (705) Example Glass U-Factor = 0.42 Btu/hr • ft2 • °F Total Daylight Opening = 27-3/4" • 51-3/4" = 9.97ft2 Total Projected Area = 3'-0" • 5'-0" = 15 ft2 Percent of Glass = (Total Daylight Opening ÷ Total Projected Area)100 = (9.97 ÷ 15)100 = 66% System U-factor vs Percent of Glass Area 0.90 (4.50) 0.75 N E IGN PL S M E A D EX OR F T O 0.60 0.55 0.53 0.50 0.45 (3.50) (3.00) W m2 • °C System U-factor (2.73) (2.61) (2.50) (2.39) (2.27) (2.16) (2.05) (1.93) (1.82) (1.71) (1.59) (1.48) (1.37) (1.25) (1.14) (4.00) 0.65 Btu hr • ft2 • °F System U-factor COG U-factor (2.50) 0.40 0.35 (2.00) 0.30 0.25 (1.50) 0.20 75 70 65 66% 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.70 60 55 50 Percent of Glass Area Based on 66% glass and center of glass (COG) U-factor of 0.42 System U-factor is equal to 0.53 Btu/hr • ft2 • °F ADME010 kawneer.com © Kawneer Company, Inc., 2011 0.80 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. (5.00) 0.85 8225TL Thermal Windows JUNE, 2015 EC 97911-075 THERMAL CHARTS FIXED WINDOW WITH 1" GLAZING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 Btu hr • ft2 • °F System U-factor System U-factor vs Percent of Glass Area 0.48 (2.74) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. COG U-factor 0.22 (1.25) 0.20 (1.14) Percent of Glass Area = Vision Area/Total Area Daylight Opening / Projected Area Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. kawneer.com ADME010 35 COG VT Vision Area / Total Area (%) ADME010 kawneer.com © Kawneer Company, Inc., 2011 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System SHGC 8225TL Thermal Windows Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System VT 36 JUNE, 2015 EC 97911-075 FIXED WINDOW WITH 1" GLAZING System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area 8225TL Thermal Windows JUNE, 2015 EC 97911-075 THERMAL PERFORMANCE MATRIX (NFRC SIZE) FIXED WINDOW WITH 1" GLAZING Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.53 0.46 0.51 0.44 0.50 0.42 0.48 0.40 0.46 0.38 0.45 0.36 0.43 0.34 0.42 0.32 0.40 0.30 0.39 0.28 0.37 0.26 0.36 0.24 0.34 0.22 0.32 0.20 0.31 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1200mm wide by 1500mm high (47-1/4" by 59-1/16"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.90 0.77 0.90 0.76 0.85 0.73 0.85 0.72 0.80 0.69 0.80 0.68 0.75 0.65 0.75 0.64 0.70 0.60 0.70 0.59 0.65 0.56 0.65 0.55 0.60 0.52 0.60 0.51 0.55 0.48 0.55 0.47 0.50 0.43 0.50 0.42 0.45 0.39 0.45 0.38 0.40 0.35 0.40 0.34 0.35 0.31 0.35 0.30 0.30 0.26 0.30 0.25 0.25 0.22 0.25 0.21 0.20 0.18 0.20 0.17 © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 37 ADME010 8225TL Thermal Windows JUNE, 2015 EC 97911-075 THERMAL CHARTS PROJECT-IN WINDOW WITH 1" GLAZING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 System U-factor vs Percent of Glass Area COG U-factor Percent of Glass Area = Vision Area/Total Area Daylight Opening / Projected Area Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. ADME010 kawneer.com © Kawneer Company, Inc., 2011 0.48 (2.74) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Btu hr • ft2 • °F System U-factor 38 System VT © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JUNE, 2015 kawneer.com 8225TL Thermal Windows EC 97911-075 Vision Area / Total Area (%) ADME010 39 THERMAL CHARTS PROJECT-IN WINDOW WITH 1" GLAZING System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area COG VT 8225TL Thermal Windows JUNE, 2015 EC 97911-075 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Overall U-Factor 4 0.48 0.59 0.46 0.58 0.44 0.57 0.42 0.56 0.40 0.55 0.38 0.54 0.36 0.53 0.34 0.51 0.32 0.50 0.30 0.49 0.28 0.48 0.26 0.47 0.24 0.46 0.22 0.45 0.20 0.44 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1500mm wide by 600mm high (59-1/16" by 23-5/8"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.90 0.58 0.90 0.56 0.85 0.55 0.85 0.53 0.80 0.52 0.80 0.50 0.75 0.49 0.75 0.47 0.70 0.45 0.70 0.43 0.65 0.42 0.65 0.40 0.60 0.39 0.60 0.37 0.55 0.36 0.55 0.34 0.50 0.33 0.50 0.31 0.45 0.30 0.45 0.28 0.40 0.27 0.40 0.25 0.35 0.24 0.35 0.22 0.30 0.21 0.30 0.19 0.25 0.18 0.25 0.16 0.20 0.14 0.20 0.12 ADME010 kawneer.com © Kawneer Company, Inc., 2011 Glass U-Factor 3 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. PROJECT-IN WINDOW WITH 1" GLAZING Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 40 8225TL Thermal Windows JUNE, 2015 EC 97911-075 THERMAL CHARTS PROJECT-OUT WINDOW WITH 1" GLAZING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 System U-factor vs Percent of Glass Area Btu hr • ft2 • °F System U-factor 0.48 (2.74) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. COG U-factor Percent of Glass Area = Vision Area/Total Area Daylight Opening / Projected Area Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. kawneer.com ADME010 41 COG VT Vision Area / Total Area (%) ADME010 kawneer.com © Kawneer Company, Inc., 2011 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System SHGC 8225TL Thermal Windows Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System VT 42 JUNE, 2015 EC 97911-075 PROJECT-OUT WINDOW WITH 1" GLAZING System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area 8225TL Thermal Windows JUNE, 2015 EC 97911-075 THERMAL PERFORMANCE MATRIX (NFRC SIZE) PROJECT-OUT WINDOW WITH 1" GLAZING Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.61 0.46 0.60 0.44 0.59 0.42 0.57 0.40 0.56 0.38 0.55 0.36 0.54 0.34 0.53 0.32 0.52 0.30 0.51 0.28 0.50 0.26 0.49 0.24 0.48 0.22 0.46 0.20 0.45 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1500mm wide by 600mm high (59-1/16" by 23-5/8"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.90 0.58 0.90 0.56 0.85 0.55 0.85 0.53 0.80 0.52 0.80 0.50 0.75 0.49 0.75 0.47 0.70 0.46 0.70 0.43 0.65 0.42 0.65 0.40 0.60 0.39 0.60 0.37 0.55 0.36 0.55 0.34 0.50 0.33 0.50 0.31 0.45 0.30 0.45 0.28 0.40 0.27 0.40 0.25 0.35 0.24 0.35 0.22 0.30 0.21 0.30 0.19 0.25 0.18 0.25 0.16 0.20 0.15 0.20 0.12 © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 43 ADME010 8225TL Thermal Windows JUNE, 2015 EC 97911-075 THERMAL CHARTS INSWING CASEMENT WINDOW WITH 1" GLAZING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 System U-factor vs Percent of Glass Area COG U-factor Percent of Glass Area = Vision Area/Total Area Daylight Opening / Projected Area Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. ADME010 kawneer.com © Kawneer Company, Inc., 2011 0.48 (2.74) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Btu hr • ft2 • °F System U-factor 44 System VT © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JUNE, 2015 kawneer.com 8225TL Thermal Windows EC 97911-075 Vision Area / Total Area (%) ADME010 45 THERMAL CHARTS INSWING CASEMENT WINDOW WITH 1" GLAZING System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area COG VT 8225TL Thermal Windows JUNE, 2015 EC 97911-075 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Overall U-Factor 4 0.48 0.59 0.46 0.58 0.44 0.57 0.42 0.56 0.40 0.55 0.38 0.54 0.36 0.52 0.34 0.51 0.32 0.50 0.30 0.49 0.28 0.48 0.26 0.47 0.24 0.46 0.22 0.45 0.20 0.44 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 600mm wide by 1500mm high (23-5/8" by 59-1/16"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.90 0.58 0.90 0.56 0.85 0.55 0.85 0.53 0.80 0.52 0.80 0.50 0.75 0.49 0.75 0.47 0.70 0.45 0.70 0.43 0.65 0.42 0.65 0.40 0.60 0.39 0.60 0.37 0.55 0.36 0.55 0.34 0.50 0.33 0.50 0.31 0.45 0.30 0.45 0.28 0.40 0.27 0.40 0.25 0.35 0.24 0.35 0.22 0.30 0.21 0.30 0.19 0.25 0.18 0.25 0.16 0.20 0.14 0.20 0.12 ADME010 kawneer.com © Kawneer Company, Inc., 2011 Glass U-Factor 3 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. INSWING CASEMENT WINDOW WITH 1" GLAZING Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 46 8225TL Thermal Windows JUNE, 2015 EC 97911-075 THERMAL CHARTS OUTSWING CASEMENT WINDOW WITH 1" GLAZING Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 System U-factor vs Percent of Glass Area Btu hr • ft2 • °F System U-factor 0.48 (2.74) 0.46 (2.61) 0.44 (2.50) 0.42 (2.39) 0.40 (2.27) 0.38 (2.16) 0.36 (2.05) 0.34 (1.93) 0.32 (1.82) 0.30 (1.71) 0.28 (1.59) 0.26 (1.48) 0.24 (1.37) 0.22 (1.25) 0.20 (1.14) © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. COG U-factor Percent of Glass Area = Vision Area/Total Area Daylight Opening / Projected Area Notes for System U-factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. kawneer.com ADME010 47 COG VT Vision Area / Total Area (%) ADME010 kawneer.com © Kawneer Company, Inc., 2011 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System SHGC 8225TL Thermal Windows Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System VT 48 JUNE, 2015 EC 97911-075 OUTSWING CASEMENT WINDOW WITH 1" GLAZING System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Vision Area / Total Area (%) System Visible Transmittance (VT) vs Percent of Vision Area 8225TL Thermal Windows JUNE, 2015 EC 97911-075 THERMAL PERFORMANCE MATRIX (NFRC SIZE) OUTSWING CASEMENT WINDOW WITH 1" GLAZING Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.60 0.46 0.59 0.44 0.58 0.42 0.57 0.40 0.56 0.38 0.55 0.36 0.54 0.34 0.53 0.32 0.51 0.30 0.50 0.28 0.49 0.26 0.48 0.24 0.47 0.22 0.46 0.20 0.45 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 600mm wide by 1500mm high (23-5/8" by 59-1/16"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.90 0.58 0.90 0.56 0.85 0.55 0.85 0.53 0.80 0.52 0.80 0.50 0.75 0.49 0.75 0.47 0.70 0.45 0.70 0.43 0.65 0.42 0.65 0.40 0.60 0.39 0.60 0.37 0.55 0.36 0.55 0.34 0.50 0.33 0.50 0.31 0.45 0.30 0.45 0.38 0.40 0.27 0.40 0.25 0.35 0.24 0.35 0.22 0.30 0.21 0.30 0.19 0.25 0.18 0.25 0.16 0.20 0.14 0.20 0.12 © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 49 ADME010 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 8225TL Thermal Windows BLANK PAGE ADME010 kawneer.com © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 50 JUNE, 2015 EC 97911-075