Isolated Data Transmission and Power Conversion Integrated Into a Surface Mount Package

Isolated Data Transmission and Power Conversion
Integrated Into a Surface Mount Package
Keith Bennett
Galvanic isolation is used in a variety of industries, most commonly to provide safety
against potentially lethal voltages. Isolation is also used to eliminate the effects of noise
and common mode voltage differences created by ground loops, or as a level shifter
between dissimilar operating voltages. Typically, building an isolated system requires
a number of passive and active components on either side of the isolation barrier, in
addition to the barrier components themselves. These barrier components can be
optical, magnetic, capacitive, RF or even GMR (giant magnetoresistance) devices.
Barrier components are notoriously difficult to use, adding significant design
time and cost to isolated systems. With
this in mind, Linear Technology has
developed a line of µModule® isolators that reduces the design of isolated
systems to simply plugging in a module—no complex barrier components
are required. In fact, µModule isolators
require no external components at all.
Linear Technology µModule isolators
use magnetically coupled techniques to
provide data and power isolation in a
single package. The result is an easy-touse, low power, robust solution with
excellent field immunity. The LTM2881
isolated RS485/RS422 transceiver and
LTM2882 dual isolated RS232 transceivers use µModule isolator technology
to provide complete transceiver-pluspower solutions in 15mm × 11.25mm
× 2.8mm surface mount packages.
ISOLATED DATA TRANSMISSION
µModule isolators use inductively coupled coils, or coreless transformers, to
pass data across the isolation boundary.
Electrical and mechanical representations are illustrated in Figure 1. Dedicated
integrated circuits perform the data
transmission and receiving functions for
all channels and both data directions.
Three channels of data are encoded,
serialized into a packet, and transmitted
Figure 1. Data isolation equivalent electrical and mechanical configuration
Rx
Tx
ENABLE
DATAIN
DATAOUT
RCVR
ENABLE
Tx
Rx
DATAIN
RCVR
30 | January 2011 : LT Journal of Analog Innovation
DATAOUT
across the isolation boundary in each
direction. Data transmission in one direction is completely independent of data
transmission in the other direction.
The encoding process is initiated when
the data changes (edge triggered) on
any of the three inputs. The three data
inputs consist of one high priority and
two low priority channels. A state change
on the high priority channel preempts
an encoding process initiated by a low
priority channel state change. This scheme
ensures that the data on the high priority channel is transmitted with no jitter
to the output, but in turn produces some
amount of timing uncertainty on the
design features
Linear Technology has developed a line of µModule isolators
that reduces the design of isolated systems to simply plugging
in a module—no complex barrier components are required. In
fact, µModule isolators require no external components at all.
LDO
3.9
VCC2
6
-3 VERSIONS
VIN (V)
3.6
5.5
-5 VERSIONS
3.3
5
3
GND
GND2
Figure 2. Simplified isolated power conversion stage
low priority channels. The high priority
channel is assigned to DI to (Y,Z) and (A,B)
to RO for the LTM2881, and from T1IN to
T1OUT and R1IN to R1OUT for the LTM2882.
All remaining channels for these products
are low priority. Encoding is completed by
sampling all three input data states and
transmitting the data across the coreless
isolation transformer as a series of pulses.
Each transmission is received as a differential signal, checked for errors,
decoded, and clocked to the associated
data output. The receiver is connected
to a center tapped transformer secondary. This winding arrangement provides
common mode rejection since any coupled
signals are cancelled by the opposing winding geometry at the receiver
input. The error checking process determines if the transmitted data is valid;
if not, the outputs are not updated.
The encoding/decoding process supports a
minimum data throughput rate of approximately 21Mbps. Edge events occurring
during a packet transmission initiate a
new capture operation, which is completed
at the end of the current transmit cycle.
Data is refreshed at a rate of approximately 1MHz, ensuring DC correctness of
all data outputs. If four invalid packets are
received in succession then a communication fault is generated. This fault mode
forces a high impedance state on certain
outputs, for instance RO and DOUT for
the LTM2881, and R1OUT and R2OUT for
the LTM2882. This fault condition can be
easily detected in critical applications.
The coreless transformer is fabricated
within the µModule substrate’s inner
layers. Minimum coil layer separation of 60µm is provided by a 2-ply
Bismaleimide-Triazine (BT) high performance resin-based laminate.
ISOLATED POWER TRANSMISSION
Isolated power is generated by more
conventional means. The overall power
converter consists of a full-bridge square
wave oscillator AC-coupled to an isolation transformer primary, rectified with
a full wave voltage doubler connected
2.7
VIN (V)
VCC
4.5
VCC2 ≥ 4.75V
0.4
0.6
0.8
1
1.2 1.4
OUTPUT POWER (W)
1.6
1.8
4
Figure 3. µModule isolator power capability
to the transformer secondary, and
post regulated by a low-dropout linear
regulator (LDO). Figure 2 schematically
shows the power conversion stage.
The overall power topology provides
a simple, flexible, fault tolerant and
relatively efficient design (~65%). Bridge
current is monitored and limited to
protect the power switches and transformer. The primary and secondary are
both AC-coupled, preventing transformer
saturation under any condition. All
components are integrated within the
µModule package; no external decoupling is required for proper operation.
Two input operating voltage ranges,
determined by transformer turns ratio,
are available: 3V to 3.6V (-3 versions) and
4.5V to 5.5V (-5 versions). Input voltage level is internally sensed, setting the
primary current limit to approximately
550m A for -3 part versions and 400m A for
-5 part versions. The converter output
power capability versus input voltage
is shown in Figure 3 for VCC2 ≥ 4.75V.
January 2011 : LT Journal of Analog Innovation | 31
PARAMETER
CONDITIONS
MIN
Rated Dielectric Insulation Voltage
1 Minute
2500
V RMS
Continuous
400
V RMS
560
V PEAK
Partial Discharge
V PR = 1050V PEAK
Common Mode Transient Immunity
MAX
5
30
kV/µs
Ω
f = 1MHz
6
pF
External Tracking (Creepage) Distance
L/BGA
9.53
mm
External Air Gap (Clearance) Distance
BGA
9.38
mm
V IO = 500V
Input to Output (Barrier) Capacitance
Comparitive Tracking Index (CTI)
Highest Allowable Overvoltage
175
Isolation Barrier ESD, HBM
V
t = 10s
4000
Minimum Distance Through Insulation
0.06
V PEAK
mm
(V CC2 , GND2) to GND
±10
kV
Isolated I/O to GND
±8
kV
Primary current limit is not active
under normal operating conditions.
and components, and related topics of interest are listed in Table 2.
The transformer comprises a toroidal ferrite core with one high voltage insulated
winding and a second low voltage insulated winding. The high voltage winding
uses supplementary-rated Teflon-insulated
wire, consisting of two independent
layers with a total insulation thickness
of 76µm. The transformer is completely
encapsulated during the µModule molding
process, providing additional protection.
UL1577 is a component level standard
designed to verify that the dielectric withstands voltages of up to 2500VRMS under
a variety of environmental conditions.
The LTM2881 and LTM2882 devices have
achieved UL approval up to an operating temperature of 100ºC. The dielectric withstand is 100% production
tested by applying a DC test voltage of
±4400V (≈2500 • 1.2 • √2) for one second
at each polarity, with all pins shorted
on each side of the isolation barrier.
ISOLATION BARRIER PERFORMANCE
As detailed above, the isolation barrier
consists of two components: data coils
insulated by BT substrate, and Teflon
insulated windings within the power
transformer. The isolation barrier is
designed to have a minimum dielectric withstand rating of 2500VRMS for
sixty seconds, and continuous working voltage of 400VRMS or 560VPEAK .
Key isolation parameters are listed
in Table 1, adopted from a wide
variety of international standards.
Standards relevant to isolation systems
32 | January 2011 : LT Journal of Analog Innovation
Table 1. Key isolation
specifications of the
LTM2881 and LTM2882
pC
10 11
Input to Output (Insulation) Resistance
10 9
UNITS
IEC 60747-5-2 is the European equivalent
component level standard, requiring a
measurement of partial discharge (PD)
across the isolation barrier at a voltage related to the rated system working
voltage. Tests under a variety of environmental conditions are required for
certification, as well as 100% production
screening. The LTM2881 and LTM2882
have been characterized for PD and easily
meet the requirements of the standard,
with less than 5pC at 1050VPEAK for a
working voltage of 560VPEAK . Certification
to IEC 60747-5-2 is in process.
The rated continuous working voltage is
not explicitly defined in any standard; its
value is dependent on a variety of environmental operating conditions, including creepage/clearance, test requirements
defined within the standards, as well as the
operational lifetime. The operating lifetime
at the rated working voltage is extrapolated from accelerated lifetime test data.
Tests results for the LTM2881 and LTM2882
are shown in Figure 4. Data conforms to
the generally accepted Weibull distribution
for accelerated dielectric breakdown testing.1 The plot shows the minimum lifetime
at 500VRMS is greater than 100 years.
Parameters related to the isolation barrier voltage rating include electrostatic
discharge (ESD), surge immunity, and
electrical fast transients. One of the major
benefits of galvanic isolation is the ability of the isolation barrier to hold off
large voltage potentials, eliminating the
need for other protection devices such as
1G
1M
LIFETIME (HOURS)
Maximum Working Insulation Voltage
TYP
MEAN
1k
MINIMUM
1
0.001
0.1
1
VAC(RMS) (kV)
10
Figure 4. µModule isolator insulation lifetime
design features
Table 2. Standards
relevant to isolation
systems and components
transient voltage suppressors. The key is
configuring the system in a way that the
barrier sees the transient event, which
is typically achieved by proper shielding of system interconnects. The isolation barrier easily withstands transient
events equal to the dielectric withstand
voltage of 2500VRMS or 3500VPEAK, and
can withstand much higher voltages for
short periods of time as evidenced by
the 8kV–10kV barrier ESD ratings, and
operating lifetimes at elevated voltages.
The input to output capacitance, or barrier capacitance, is an important parameter impacting many aspects of overall
performance. In general, the lower the
capacitance the better. The capacitance
is a parasitic element and is the parallel
combination of data coil and transformer
winding capacitance. Typical capacitance is 6pF at 1MHz with the data coils
accounting for 1.2pF each and the power
transformer 3.6pF. In the case of transients, one or more ESD or body diodes
conducts the transient energy to the
barrier capacitance and back to ground.
A smaller barrier capacitor absorbs more
transient voltage, reducing the energy
dissipated in the functional IC, thus
minimizing the potential for damage.
The magnitude of capacitance also
impacts the common mode transient
immunity. This parameter is a measure of
the component’s ability to maintain proper
function in the presence of high slew
rate signals across the isolation barrier.
µModule isolators support a minimum
common mode transient rate of 30kV/µs
(50kV/µs typical), operating through these
STANDARD
DESCRIPTION
UL1577
Standard for Safety, Optical Isolators
IEC 60747-5-2 (VDE 0884-10)
Optoelectronic Devices, Essential Ratings and Characteristics
IEC 60664-1
Insulation Coordination for Equipment within Low-Voltage Systems
IEC 60950-1
Information Technology Equipment—Safety
IEC 61010-1
Measurement, Control, Laboratory Equipment—Safety
IEC 60601-1
Medical Electrical Equipment
IEC 61000-4-2
Electrostatic Discharge Immunity
IEC 61000-4-3
Radio Frequency Field Immunity
IEC 61000-4-4
Electrical Fast Transients
IEC 61000-4-5
Surge Immunity
IEC 61000-4-8
Power Frequency Magnetic Field Immunity
IEC 61000-4-9
Pulse Magnetic Field Immunity
CISPR 22
Radiated Emissions - Information Technology Equipment
IEC 60079-11
Intrinsic Safety
transient events error-free while transmitting data. The barrier capacitance displaces a current equal to the capacitance
times the slew rate into the application
die, potentially disrupting its function
by inducing noise or triggering parasitic
device structures. Under the extreme conditions needed to produce common mode
errors, µModule isolator products do not
exhibit any latch-up, instead showing
only momentary state changes corrected
during the next communication cycle.
ELECTROMAGNETIC COMPATIBILITY
The barrier capacitance also plays a role
in the system’s electromagnetic compatibility, specifically radiated emissions.
Just as transient common mode events
inject current through the parasitic barrier
capacitance, so do the data and power
drive circuits. These drive circuits have fast
edge rates which ultimately create a voltage transient on the isolated ground plane
(GND2). Most isolated printed circuit board
layouts use separate ground planes for
the input (GND) and output (GND2) sides.
This dual ground plane structure forms
a dipole antenna, providing an effective
radiator of the common mode voltage created by the parasitic barrier capacitance.
Another way to look at this problem is
to consider the currents generated in the
parasitic capacitance by the drive circuits.
These currents require a return path.
If the current is not returned through
one of the parallel parasitic capacitors,
it will be returned through the capacitance created by a pair of ground planes,
or potentially through the capacitance
formed between interconnect wires and
ground. The radiated emissions can be
quite high if not properly mitigated.
The most effective technique is to provide a low impedance return path at
the frequencies of interest—namely an
additional capacitor between the isolated
ground planes, or bridge capacitor.
The structures and isolation techniques
used in isolator µModule technology
are insufficient in themselves to radiate enough power to exceed the Class
B limit of CISPR 22. The data coils are
essentially small loop antennas, whose
January 2011 : LT Journal of Analog Innovation | 33
The center tapped receiver coils provide a high level of
rejection to external RF and magnetic fields or common
mode signals, due to the opposing winding turns.
60
CISPR 22 CLASS A LIMIT
50
•Insure that all signal and power traces
have closely coupled return paths to
minimize radiation created by these
localized loops. Avoid transitioning signals from layer to layer as the image current often cannot follow the same path.
FCC CLASS A LIMIT
AMPLITUDE (dBµV/m)
40
CISPR 22 CLASS B LIMIT
30
20
10
PREDICTED
DATA COIL
EMISSIONS
0
−10
Figure 5. Predicted
versus actual total
radiated emissions
LTM2881 LOW-EMI DEMO BOARD EMISSIONS
RBW = 120kHz
VBW = 300kHz
DETECTOR = PEAK
SWEEP TIME = 17s
10
100
FREQUENCY (MHz)
N
∑ (rn λ )
4
WATTS
(1)
n=1
If = current at frequency
rn = radius of nth coil turn in meters
N = Total number of turns
λ = wavelength at frequency
As shown, the emission levels fall far
below the required CISPR 22 and related
FCC limits.
Additional EMI mitigation techniques
include:
•Minimize the size of the isolated ground
plane.
100
1k
C
AN
ST
DI
=
1m
=
10
1
100
E
CE
AN
ST
DI
10
0m
10
m
E
=
0.1
m
5m
1
0.01
0.001
0.1
CURRENT
FLUX DENSITY
1
10
100
1k
10k
MAGNETIC FIELD FREQUENCY (kHz)
0.01
100k
•Use filtering for all off-board interconnection. This can often be done with
ferrite based chip beads and common
mode filters. Care must be exercised
to ensure the filter components do not
compromise the integrity of signals on
the associated data lines. The filtering
provides a high impedance block to
radio frequency signals. Shunt capacitance can also be used to provide a
local low impedance return path.
•Reduce the operating supply voltage, or
use the lower input voltage version (-3)
of the part.
•Low-EMI versions of the LTM2881 and
LTM2882 demo boards, DC1746A and
DC1747A respectively, are available,
leveraging many of these techniques.
Figure 6. Magnetic field immunity
C
AN
ST
34 | January 2011 : LT Journal of Analog Innovation
with discrete capacitors to further reduce
emissions below 300MHz, above which
frequency the parasitic inductance limits
their usefulness. Recommended discrete
capacitors are AC safety rated, Y2 type,
applied two in series to meet safety standard requirements. Murata’s Type GF series
of Y2 capacitors meet this requirement.
DI
Several techniques can be used to ensure
a design with minimal radiated emissions. The first, as mentioned, is the use
of a bridge capacitor, implemented by
overlapping a floating plane of printed
circuit board copper, typically using an
inner layer, over the input and isolated
ground planes. This provides a nearly ideal
capacitor, and two insulation barriers are
created to support the isolation voltage.
This technique can be used in combination
1k
MAXIMUM ALLOWABLE CURRENT (kA)
−30
MAXIMUM ALLOWABLE FLUX DENSITY (kGauss)
2
•Add a combination of low ESL and high
impedance decoupling capacitors to
high current power rails, preventing
conducted noise and parasitic ringing from becoming radiated noise.
−20
emissions level can be predicted by solving
the radiated power loop antenna equation (1). Figure 5 shows the results of this
equation using simulated coil current
spectrum data as well as actual measured
data, which also includes contributions
from the isolated power component.
PRAD = 160π 6 (If )
FCC CLASS B LIMIT
ELECTROMAGNETIC IMMUNITY
By superposition, an inefficient radiator is also an inefficient receiver. The
LTM2881 and LTM2882 have been independently evaluated for radio frequency
and magnetic field immunity. Table 3
summarizes the applicable test standards
with passing field strength levels.
design features
The LTM2881 RS485 transceiver and the LTM2882 dual RS232 transceiver
combine desirable data-plus-power isolation features in a robust small-package
system. Both devices feature superior transient common mode rejection, magnetic
field immunity, ESD and transient barrier withstand, and insulation lifetime.
Passing the test requirements, however,
does not give much insight to the system’s
true immunity level. The external magnetic
field required to corrupt data communication can be calculated by equation (2),
where V represents the differential receiver
threshold voltage. The center tapped
receiver coils provide a high level of rejection to external RF and magnetic fields or
common mode signals, due to the opposing winding turns. Since the data coils are
not completely symmetric, some differential voltage is generated, represented
by the net difference in area between
the center tap coil turns. The maximum
external magnetic field relative to receiver
threshold is plotted in Figure 6, taking into
account the common mode cancelation.
TEST
FREQUENCY
FIELD STRENGTH
80MHz–1GHz
10V/m
1.4MHz–2GHz
3V/m
2GHz–2.7GHz
1V/m
IEC 61000-4-8 Level 4
50Hz and 60Hz
30A/m
IEC 61000-4-8 Level 5
60Hz
100A/m (non IEC method)
IEC 61000-4-9 Level 5
Pulse
1000A/m
IEC 61000-4-3 Annex D
Table 3. Electromagnetic field immunity
IEC 60664-1 deals specifically with insulation systems and is a reference standard to IEC 60950-1, IEC 61010-1, and
IEC 60601-1. These standards define the
required creepage, clearance, etc., based
on the type of equipment installation
and operating environment. The following terms and definitions are used
throughout the various standards:
•Material Group: Classification based
on an insulating components relative
comparative tracking index, a measure
of the surface electrical breakdown
properties of an insulating material.
N = number of turns in receiving coil
rn = radius of nth coil turn in centimeters
•Basic Insulation: Insulation to provide
basic protection against electric shock.
•Pollution Degree: Numeral characterizing the expected pollution of the
microenvironment, degrees include 1, 2
and 3. The level of pollution can result
in a reduction of electric strength or
surface resistivity of the insulation.
Alternatively, the magnetic field due to
an alternating current flowing in a wire
some distance away can be calculated.
Figure 6 also plots this result for distances
of 5mm, 100mm, and 1m away from the
device in question. For example, a current of 1000A running at 1MHz in a wire
5mm away would be required to corrupt data transmission at the receiver.
•Supplementary Insulation: Independent
insulation applied in addition to
basic insulation in order to reduce
the risk of electric shock in the event
of a failure of the basic insulation.
•Overvoltage Category: Numeral defining
a transient overvoltage condition; categories include I, II, III and IV. Operating
category is a function of the highest
RMS operating voltage within the system.
•Double Insulation: Insulation comprising both basic insulation and
supplementary insulation.
•Creepage: Shortest distance along the
surface of a solid insulating material between two conductive parts.
•Reinforced Insulation: Single insulation
system that provides a degree of protection against electric shock equivalent to
double insulation. It may comprise several layers that cannot be tested as basic
insulation and supplementary insulation.
•Clearance: Shortest distance in air
between two conductive parts.
N
 dβ 
2
V = −  ∑ π (rn ) VOLTS
 dt  n=1
(2)
β = magnetic flux density in gauss
SAFETY STANDARDS
Creepage, clearance, tracking index, and
minimum distance through insulation
are safety related parameters used in the
various equipment level standards and
insulation coordination standards to
determine proper component application.
A complete interpretation of IEC 60664-1
and related standards as they apply to
µModule isolators is beyond the scope of
this article. Neverthless, Table 4 summarizes some of the key parameters for
January 2011 : LT Journal of Analog Innovation | 35
Table 4. Isolation categories
PARAMETER
CONDITION
SPECIFICATION
Basic Isolation Group
Material Group, 175 ≤ CTI < 400
IIIa
Rated Mains Voltage ≤ 150V RMS
I–IV
Rated Mains Voltage ≤ 300V RMS
I–III
Rated Mains Voltage ≤ 400V RMS*
I–II
Installation Class
*Range is normally 600V RMS, limited by devices rated working voltage
µModule isolators often listed on component data sheets. It is worth noting that
the creepage and clearance distances of
the LTM2881 and LTM2882 modules greatly
exceed the requirements for the rated
working voltage for all insulation categories, pollution degrees, overvoltage categories, and material groups. For components
classified with a Basic Insulation level
there is no minimum for distance through
insulation. Supplementary and Reinforced
Insulation systems require a distance of
400µm, or they must meet the type (conditioned sample) and routine (production)
test requirements for partial discharge
and/or dielectric withstand. µModule
isolators are considered Basic Insulation
systems at the rated working voltage.
and reactive component energy storage
to prevent the generation of sparks. The
LTM2881 and LTM2882 are suitable for
level of protection “ic” for peak voltages up to 60V. These products meet
all of the requirements for protection
levels “ia”, “ib”, and “ic” except for
distance through solid insulation.
ESD, EFT AND SURGE
Electrical transients are covered in
IEC 61000-4-2 (Electrostatic Discharge
Immunity), IEC 61000-4-4 (Electrical Fast
Transients), and IEC 61000-4-5 (Surge
Immunity). Each of these standards covers
transient events that are similar in nature
and approximate different real world
events such as lighting strikes, conductive
circuit interruption, and device handling.
The differences between the transients
lie in the peak voltages, impulse duration, and repetition rates. In non-isolated
systems the addition of protective components is often required to protect against
transient events. Proper application of
Intrinsic Safety is a standard covering equipment protection in explosive
atmospheres. Component requirements
are more stringent, and include limits
for temperature rise, maximum current,
µModule isolators allows the isolation
barrier to absorb the transient, eliminating the need for additional protection.
Figure 7 shows a properly configured
test set-up to meet the requirements of
EFT testing. Surge testing is performed with
the signal applied directly to the shield.
The transient (burst) generator is capacitively coupled to the shielded I/O lines
of the LTM2881. The coupling device is
depicted as a second shield with length of
0.5 meters per standard. The return side of
the burst generator is tied to the logic side
ground. The shield conducts the transient
to the isolated ground then across the isolation barrier to the generator return. The
parasitic inductance (LPAR) must be minimized or some of the transient is coupled
into the signal lines, decreasing the transient immunity effectiveness. The isolation
barrier has been tested and is compliant
to level 4 (4kV) for both surge and EFT.
Figure 7. EFT test configuration
0.5m
5V
LTM2881-5
VCC
VCC2
VL
PWR
RO
RE
TE
DE
DI
ISOLATION BARRIER
ON
DOUT
GND
36 | January 2011 : LT Journal of Analog Innovation
SLO
CPAR
A
B
CPAR
LPAR
CC 100pF–1000pF
Y
Z
DIN
GND2
BURST
GENERATOR
design features
Electrostatic discharge testing is performed
directly from pin to pin of the device.
Barrier ESD is performed from any logic
side pin to isolated side pin. The LTM2881
and LTM2882 have an ±8kV HBM (human
body model) ESD rating from any logic
side I/O pin to isolated side I/O pin, and
a ±10kV HBM, ±8kV IEC, ESD rating from
any isolated side power pin, VCC2 or GND2,
to logic side power pin, VCC , VL , or GND.
THE LTM2881 AND LTM2882
Linear Technology’s first released µModule
isolators are the LTM2881 RS485/RS422
transceiver plus power, and the LTM2882
dual RS232 transceiver plus power. Both
offer distinct advantages over alternative
solutions including excellent common
mode rejection, integrated high efficiency
isolated power and low EMI. Furthermore,
no external components, including power
decoupling capacitors, are required.
Each has separate logic power supply
inputs for easy interface to low voltage
systems ranging from 1.62V to 5.5V.
Two main power supply options are
offered, 3.0V to 3.6V and 4.5V to 5.5V,
which are completely independent of
the logic supply. Devices are available
in LGA and BGA packages with ambient temperature ranges of 0ºC to 70ºC,
–40ºC to 85ºC, and –55ºC to 105ºC.
The LTM2881, shown in Figure 8, is a
20Mbps transceiver with integrated selectable termination and 250kbps reduced
Figure 8. LTM2881 isolated RS485 µModule transceiver
3.3V OR 5V
Isolated
Power
REG
5V
RO
RS485/RS422
BUS
DI
ON
LTM2881
Figure 9. LTM2882 dual RS232 µModule transceiver
3.3V OR 5V
Power
T1IN
REG
5V
T1OUT
R1OUT
R1IN
T2IN
T2OUT
R2OUT
R2IN
The LTM2882, shown in Figure 9, is a
dual channel 1Mbps transceiver featuring one uncommitted isolated digital channel from logic to isolated
side and ±10kV HBM ESD protection
on the RS232 interface pins.
CONCLUSION
The LTM2881 RS485 transceiver and the
LTM2882 dual RS232 transceiver use Linear
Technology µModule isolator technology
to combine desirable data-plus-power
isolation features in a robust smallpackage system. Both devices feature
superior transient common mode rejection, magnetic field immunity, ESD and
transient barrier withstand, and insulation
lifetime. The core isolation techniques may
be applied to a breadth of applications.
Certification to UL1577 has been completed. The certification process has
been initiated for IEC 60747-5-2, including routine (production) test support for
partial discharge, and certification to
CSA (Canadian) Component Acceptance
Notice #5A in relation to IEC 60950-1.
Isolation terminology and relevant safety
standards have been introduced to aid
in the application of Linear Technology
µModule isolator products across all
industries. Isolation barrier performance is
under constant evaluation (i.e., insulation
lifetime, partial discharge, etc.) to ensure
the highest reliability and performance.
GALVANIC ISOLATION
Isolated
slew rate operating mode. The device
includes one uncommitted isolated digital
channel from isolated side to the logic
side and features ±15kV HBM ESD protection on the RS485 interface pins.
RS232
BUS
Additional product certifications may be
added to further distinguish the products’
exceptional isolation characteristics. n
Notes
1V.Y.
Ushakov, Insulation of High-Voltage Equipment,
Springer-Verlag, Berlin (2004)
LTM2882
GALVANIC ISOLATION
January 2011 : LT Journal of Analog Innovation | 37