MITEL SP8861NAHP

SP8861
1·3GHz Low Power Single-Chip Frequency Synthesiser
LOCK DETECT
1
28
27 26
25
PD2 OUTPUT
POWER DOWN
6
24
RPD
VEE4
7
23
VCC3
VCC4
8
22
GROUND
VCC1
9
21
XTAL 1
RF INPUT
10
20
XTAL2
RF INPUT
11
19
VEE2
16
17 18
20·3V to 17V
255°C to 1150°C
240°C to 185°C
2·5V p-p
NC
VCC2
15
ENABLE
14
DATA
VEE1
13
CLOCK
SP8861
HP28
*FPD and FREF outputs are reversed by the phase
detector sense bit in the F1/F2 programming word. The
above diagram is correct when the sense bit is low. See
Table 2 and Fig. 7.
VCC1, VEE1 – preamplifier and prescaler supplies
VCC2, VEE2 – oscillator supplies
VCC3, VEE3 – charge pump 2 supplies
VCC4, VEE4 – ECL supplies
Fig. 1 Pin identification diagram (top view)
ABSOLUTE MAXIMUM RATINGS
Supply voltage
Storage temperature
Operating temperature
Prescaler input voltage
NC
Cd
2
5
12
FEATURES
■ Improved Digital Phase Detector Eliminates
‘Dead Band’ Effects
■ Low Operating Power, Typically 175mW
■ 1·3GHz Operating Frequency
■ Complete Phase Locked Loop
■ High Input Sensitivity
■ Programmed throughThree-Wire Bus
■ Wide Range of Reference Division Ratios
■ Local Storage for Two Frequency Words, giving
Rapid Frequency Toggling
■ Programmable Phase Detector Gain
■ Power Down Mode
VEE3
3
IC
PD1 OUTPUT
4
FREF*
F1/F2
The SP8861 is a low power single chip synthesiser
intended for professional radio applications, containing all the
elements (apart from the loop amplifier) required to build a PLL
frequency synthesis loop
The device is serially programmable by a three-wire data
highway and contains three independent buffers to store one
reference divider word and two local oscillator divider words.
A digital phase detector with two charge pumps,
programmable in phase and gain, are provided to improve
lock-up performance. The preset operation of the charge
pumps can be overwritten or the comparison frequencies
switched to output ports under control of the divider word. The
dual modulus ratio and so operating range is also
programmable through the same word.
A power down mode is incorporated as a battery economy
feature.
DS3640 - 4.0 April 1998
FPD*
Supersedes version in the1996 Professional Products IC Handbook, HB2480 - 3.0
ORDERING INFORMATION
SP8861/NA/HP
SP8861
RF INPUT
RF INPUT
10
16/17 OR 8/9
CONTROL
11
LOGIC
F1/F2
DATA
CLOCK
ENABLE
A COUNT
1LOGIC
M COUNT
1LOGIC
4 BIT
15 BIT
fPD
PHASE
DETECTOR
2 BIT
13
DUAL
F1/F2
DATA
BUFFER
1 BIT
CHARGE
PUMP 1
3
14
N0
15
DATA
INPUT
N3
N4
2-BIT
SR
N18
N19
N20
N21
22 BIT SHIFT REGISTER
24
16
28
N0
POWER 6
DOWN
N12
N13
13 BIT
N14
1 BIT
N15
CHARGE
PUMP 2
SINGLE
REFERENCE
BUFFER
2 BIT
R
COUNT
4
*FREF and FPD outputs are reversed by the phase detector
sense bit in the F1/F2 programming word. The pin allocations
shown are correct when the sense bit is low (see Table 2 and Fig. 7).
20
21
CRYSTAL
Fig. 2 SP8861 block diagram
VCC
PD1
3
CHARGE PUMP 1 DISABLE
(SEE TABLE 4)
CHARGE
PUMP 1
45k
31
+
CHARGE
PUMP 2
Output current at pin 27 is proportional to
voltage difference between pins 25 and 28,
IMAX = 625µA
−
−
10k
+
31
TRANSCONDUCTANCE
AMPLIFIER
fPD
fREF
31 BUFFER
−
27
LOCK DETECT
+
PHASE
DETECTOR
45k
24
RPD
25
PD2
DUAL VOLTAGE
COMPARATOR
28
Cd
Fig. 3 Detailed block diagram of lock detect circuit
Cd
PD2
27 LOCK
DETECT
fREF
REFERENCE
DIVIDER
RPD
25
5
OUTPUT
INTERFACE
LOGIC
2
PD1
FREF*
FPD*
SP8861
400
TYPICAL OVERLOAD
INPUT VOLTAGE (mV RMS)
350
300
250
200
GUARANTEED
OPERATING
WINDOW
48/9 MODE
150
GUARANTEED
OPERATING
WINDOW
416/17 MODE
TYPICAL
SENSITIVITY
100
50
25
0
0
80 150
650
500
750
1000
1300
1500
FREQUENCY (MHz)
Fig. 4 Typical input characteristics and input drive requirements for SP8861
tS1tCH
DATA
2V
tS
FIRST DATA BIT
tCH
LAST DATA BIT
tCL
tREP
CLOCK
ENABLE
2V
2V
tE
tREP = 1µs min., tS = 50ns min., tCH = 50ns min., tCL = 100ns min., tE = 50ns min.
Fig. 5 Data and clock timing requirements
3
SP8861
ELECTRICAL CHARACTERISTICS
These characteristics are guaranteed over the following range of operating conditions unless otherwise stated:
Supply voltage VCC = 14·75V to 15·25V. TAMB = 255°C to 1125°C (A Grade), 240°C to 185°C (B Grade)
Value
Characteristic
Supply current
Supply current in power down mode
Units
Typ.
Max.
8,9,18,23
33
40
mA
8
4·5
6
mA
Min.
Conditions
Input sensitivity
10,11
See Fig. 4
Input overload
10,11
See Fig. 4
RF input division ratio
Comparison frequency
Reference oscillator input frequency
External reference input voltage
Reference division ratio
Data clock repetition rate, tREP
10,11,4
256
524287
With 416/17 selected
56
262143
With 48/9 selected
4,5
5
MHz
20,21
4
20
MHz
20
10
500
mVrms
20,5
1
8191
1
15
µs
See Fig. 5
ns
See Fig. 5
14,15
50
DATA input high
14
0·6VCC
VCC
V
DATA input low
14
VEE
0·3VCC
V
CLOCK input high
15
0·6VCC
VCC
V
CLOCK input low
15
VEE
0·3VCC
V
Data ENABLE high
16
0·6VCC
VCC
V
Data ENABLE low
16
VEE
0·3VCC
V
F1/F2 input high
13
0·6VCC
VCC
V
F1 buffer selected
F1/F2 input low
13
VEE
0·3VCC
V
F2 buffer selected
POWER DOWN input high
6
0·6VCC
0·9VCC
V
POWER DOWN input low
6
VEE
0·3VCC
V
F1/F2 input current
13
5
µA
V pin 13 = 5·0V
POWER DOWN input current
6
5
µA
V pin 6 = 4·5V
RDP external resistance
24
330
kΩ
LOCK DETECT output voltage when in lock
27
1
V
I pin 27 = 1mA
LOCKDETECT switching voltage high
25
V
VCC = 5V
LOCK DETECT switching voltage low
25
V
VCC = 5V
V
VCC = 5V, external pulldown
may be required
Minimum setup time, tS
FPD and FREF output voltage swing
4
Pin
68
2·7
2·3
0·9
SP8861
DESCRIPTION
Prescaler and AM Counter
The programmable divider chain is of AM counter design
and therefore contains a dual modulus front end prescaler, an
A counter which controls the dual modulus ratio and an M
counter which controls the bulk multi-modulus division.
A programmable divider of this type has a division ratio of
MN1A and a minimum integer steppable division ratio
of N(N21).
In the SP8861, the dual modulus front end prescaler is a
dual N ratio device, capable of being statically switched
between 416/17 and 48/9 ratios. The controlling A counter is
of four-bit design, allowing a maximum count sequence of 15
(2421), which begins with the start of the M counter sequence
and stops when it has counted by the pre-loaded number of
cycles. While the A counter is counting, the dual modulus
prescaler is held in the N11 mode then reverts to the N mode
at the completion of the sequence.
The M counter is a 15-bit asynchronous divider which
counts with a ratio set by a control word. In both A and M
counters the controlling data from the F1/F2 buffer is loaded
in sequence with every M count cycle. The N ratio of the dual
modulus prescaler is selected by a one-bit word in the
reference divider buffer and, when when a ratio of 48/9 is
selected, the A counter requires only three programming bits,
having an impact on the frequency bit allocation as described
in the data entry section.
Reference Source and Divider
The reference source in the SP8861 is obtained from an
on-chip oscillator which is frequency controlled by an external
crystal. The oscillator can also function as a buffer amplifier to
allow the use of an external reference source. In this mode, the
source is simply AC-coupled into the oscillator transistor base
on pin 20.
The oscillator output is coupled to a programmable reference
counter (R) whose output is the reference for the phase
detector. The reference divider is a fully programmable 13-bit
asynchronous design and can be set to any division ratio
between 1 and 8191. The actual division ratio is controlled by
a data word stored in the internal reference buffer.
Phase Detector
The SP8861 contains a digital phase detector which feeds
two charge pump circuits. Charge pump 1 has preset currents
which are programmble as shown in Table 1. Charge pump 2
has a current level set by an external resistor RPD; the current
is multiplied by a factor which is determined by bits G1 and G2
of the F1 or F2 word (see Table 1). Note that charge pump 2
current is pin 24 current 3 muliplication factor, where
I pin 24 =
VCC21·5V
RPD
A lock detect circuit is connected to the output of charge
pump 2. when the voltage level at pin 25 is between
approximately 2·25V and 2·75V, LOCK DETECT (pin 27) will
be low and charge pump 1 disabled, depending on the PD1
and PD2 programming bits as shown in Table 4.
The output signals from the R and M counters are available
on pins 4 and 5 (FPD and FREF) when programmed by the
reference programming word; the various options are shown
in Table 4. An external phase detector may be connected to
pins 4 and 5 and may be used independently or in conjunction
with the on-chip phase detector.
To allow for control direction changes introduced by the
design of the control loop, a control bit in the F1/F2 programming
word interchanges the inputs to the on-chip phase detector
and reverses the functions on pins 4 and 5 (see Table 2).
F1 or F2 word
G2
G1
Charge pump 1
current (µA)
Charge pump 2
multiplier
0
1
0
1
0
0
1
1
50
75
125
200
1
1·5
2·5
4
Table 1 Charge pump currents
Output for RF phase lag
F1/F2 sense bit
Pins 3 and 25
Pin 4
Pin 5
0
1
Current source
Current sink
FPD
FREF
FREF
FPD
Table 2
Data Entry and Storage
The data section of the SP8861 consists of a data input
interface, a data shift register and three data buffers.
Data is entered to the data input interface via a three-wire
highway, with DATA (pin 24), CLOCK (pin 15) and ENABLE
(pin16) inputs. The input interface routes the data into a 24bit shift register with bus connections to three data buffers.
Data entered via the serial bus is transferred to the appropriate
data buffer on the negative transition of the data enable input
according to the two final data bits C1 and C2 as shown in
Table 3. The MSB of the data is entered first.
2-bit SR contents
Buffer loaded
C2
C1
0
1
0
0
0
1
F1
F2
Transfer A counter bits (N0:N3)
into 4-bit buffer (see Figs. 2 and 7)
1
1
Reference
Table 3
The dual F1/F2 buffer can receive two 22-bit words and
controls the programmable divider A and M counters using 19
bits, the phase detector gain with two bits and the phase
detector sense with one bit. A fourth input from the synthesiser
control system selects the active buffer.
The third buffer contains only 16 bits, 13 being used to set
the reference divider division ratio and 2 to control the phase
detector enable logic. The remaining bit sets the dual modulus
prescaler N ratio.
The data words may be entered in any individual multiple
sequence and the shift register can be updated whils the data
buffers retain control of the synthesiser with the previously
loaded data. This enables four unique data words to be stored
in the device, with three in the data buffers and a fourth in the
shift register, while the chip is enabled. The F1 word may also
be updated while F2 is controlling the programmable divider
and vice-versa.
The dual F1/F2 buffer enables allows the device to be
toggled between two frequencies using the F1/F2 select input
at a rate determined by the comparison frequency and also
permits random frequency hopping at a rate determined by a
btye load period; this is possible because the loop can be
locked to F1 while F2 is updated by entering new data via the
shift register. The F1/F2 input is high to select F1.
5
SP8861
unused bit in the 22-bit F1/F2 buffer. This bit must always be
set to zero when the 48/9 mode is required. Various
programming sequences are shown in Fig. 7.
The data entry and storage registers are always powered
up, making it possible to enter data when the device is in the
powered down state.
An F1 or F2 update cycle will consist of a byte containing
24 bits whereas the reference byte will contain 18 bits. The
device requires 3 bytes, each with a chip select sequence,
totalling 66 bits to fully program.
When the dual modulus A counter is set to 48/9, the data
required to set the counter is reduced by one bit, leaving an
PD2
PD2
Result
0
0
FREF and FPD outputs off, charge pumps 1 and 2 on
1
0
FREF and FPD outputs on, charge pump 1 off, charge pump 2 on
0
1
FREF and FPD outputs off, charge pump 1 disabled by lock detect, charge pump 2 on
1
1
FREF and FPD outputs on, charge pump 1 disabled by lock detect, charge pump 2 on
Table 4
LOOP FILTER
FREF
15V
15V
FPD
15V
C2
C1
Rx
2·2k
R2
SL562
15V
−
+
4
Rx
VCC
2
3
2
1
28
27
Rb
26
5
25
6
24
SP8861
8
Rb >
0·25
PD2 current
15V
23
7
RPD
22
9
21
10
20
11
19
33p
1n
VOLTAGE
CONTROLLED
OSCILLATOR
12
0·1µ
13
14
15
16
CONTROL
MICRO
VCC
20
19
3
2
1
28
27
FROM
CHARGE
PUMP
SP8861
10k
Ra
26
25
24
VARICAP
SUPPLY
15V
Cd
EXTERNAL
REFERENCE
SOURCE
1n
VCC
TO LOOP
AMPLIFIER
NC
18
1n
Fig. 6a Typical application
21
17
39p
TO VCO
LOOP
FILTER
470
Ra
22k
Fig. 6b Connection
of external reference
0·25
Ra > 23
PD2 current
Fig. 6c Use of lock detect circuit with PD1
Fig. 6 Application diagrams
6
Fig. 6d Simple discrete amplifier
SP8861
PHASE
DETECTOR GAIN
CONTROL
(SEE TABLE 1)



MSB
217
216
215
214
213
212
211
210
29
28
27
26
25
24
23
22
21
20
C2 C1






























G2 G1
LSB
218
15-BIT PROGRAMMABLE COUNTER (M COUNTER)
PHASE
DETECTOR
SENSE BIT
(SEE TABLE 2)
4-BIT
PROGRAMMABLE
COUNTER
(A COUNTER)
Fig. 7a F1 or F2 word, bit allocation with 416/17 selected
PHASE
DETECTOR GAIN
CONTROL
(SEE TABLE 1)
MUST BE ZERO



215
214
213
212
211
210
29
28
27
26
25
24
23
0
15-BIT PROGRAMMABLE COUNTER (M COUNTER)
PHASE
DETECTOR
SENSE BIT
(SEE TABLE 2)
22
21
20
C2 C1



216






















G2 G1
LSB
217





MSB
CONTROL
LOGIC
(SEE
TABLE 3)
3-BIT
CONTROL
PROGRAMMABLE LOGIC
COUNTER
(SEE
(A COUNTER) TABLE 3)
Fig. 7b F1 or F2 word, bit allocation with 48/9 selected
DUAL MODULUS
N RATIO SELECT
0 = 416/17
1 = 48/9
MSB
LSB
212 211 210 29
28
27
26
25
24
23
22
21
20
C2
C1


























PD1 PD2
13-BIT PROGRAMMABLE COUNTER (R COUNTER)
PHASE
DETECTOR
BISTABLE
CONTROL
(SEE TABLE 4)
CONTROL
LOGIC
(SEE
TABLE 3)
Fig. 7c Reference word bit allocation
F1 WORD
22 BITS
F2 WORD
0 0
22 BITS
REF WORD
1 0
22 BITS
1 1
DATA
22 CLOCKS
22 CLOCKS
22 CLOCKS
DATA CLOCK
CHIP SELECT
DATA LOADS ON FALLING EDGES
Fig. 7d Data load sequence
Fig. 7 Data format diagrams
7
SP8861
VCC1
13·25k
500
1250
VCC4
6k
1250
6k
VCC4
62·5k
12k
12k
500
10
3, 14, 6
77·5k
RF INPUT
15, 16
11
24k
RF INPUT
10k
50µA
0·8mA
176k
37·5k
50µA
VEE1
27·5µA
VEE4
Fig. 8a RF preamplifer inputs
Fig. 8b F1/F2 data and
power down inputs
VEE4
Fig. 8c Hysteresis inputs, data clock
and enable
VCC4 (CP1) / VCC3 (CP2)
VCC2
VCC3
24k
20
f UP
21
80k
f UP
3, 25
VEE
VCC
27
100µA
f DOWN
f DOWN
35k
VEE3
50µA
VEE2
VEE4 (CP1) / VEE3 (CP2)
Fig. 8d Oscillator pins
Fig. 8e Lock detect output
Fig. 8f Phase detector charge pumps
VCC4
10k
VCC3
EXTERNAL
RESISTOR
RPD
(See Table 1)
FROM M OR R
COUNTERS
24
4, 5
OUTPUT
ENABLE
VEE3
100µA
50µA
VEE4
Fig. 8g Charge pump 2 current
programming
Fig. 8h FPD and FREF outputs
Fig. 8 Input and output interface diagrams
8
SP8861
DESCRIPTION
A basic application using a single phase detector is shown
in Fig. 6a. The SP8861 is a 1·3GHz part so good RF design
techniques should be employed, including the use of a ground
plane and suitable high frequency capacitors at the RF input
and for power supply decoupling.
The RF input should be coupled to either pin 10 or pin 11,
with the other pin decoupled to ground. The reference oscillator
is of conventional Colpitts type, with two capacitors required to
provide a low impedance tap for the feedback signal to the
transistor emitter. Typical values are shown in Fig. 6a, although
these may be varied to suit the loading requirements of
particular crystals. Where a suitable reference signal already
exists or where a very stable source is required, it is possible
to apply an external reference as shown in Fig. 6b. The
amplitude should be kept below 0·5Vrms to avoid forward
biasing the transistor’s collector-base junction.
Lock Detect and Charge Pump Operation
In some systems, it is useful to have an indication of phase
lock. This function is provided on pin 27 (LOCK DETECT),
which goes low when the output of charge pump 2 (PD2) is
between 2·25V and 2·75V and can be used to drive an LED to
give visual indication of phase lock. Alternatively, a pullup
resistor may be connected from pin 27 to VCC and the output
used to signal to the control microprocessor that the loop is
locked, thus speeding up system operation. The output current
available from pin 27 is limited to 1·5mA; if this is exceeded,
the logic low level will be uncertain.
The circuit diagram of Fig. 6a is a basic application with
minimum component count but which is neverthless perfectly
adequate for many applications. Charge pump 1 output (pin3)
is used to drive the loop amplifier which provides the control
voltage for the VCO. When charge pump 1 is used in this
mode, the PD1 and PD2 bits in the reference programming
word must be set to enable charge pump 1 continuously (see
Table 4). This application could also use charge pump 2 output
(pin 25) or, if a higher phase detectot gain is required, pins 3
and 25 could be connected in parallel to use the combined
output current from both charge pumps.
The lock detect circuit can be programmed to automatically
disable charge pump 1 as shown in Table 4. This feature can
be used to reduce the system lock up time by connecting the
charge pump outputs in parallel to the loop amplifier with
resistor Rb connected in series with charge pump 2 output.
This connection allows a relatively high current to be used
from charge pump 1 to give a short lock up time, and a low
charge pump 2 current to be set to give low reference frequency
sidebands. The degree of lock up time improvement depends
on the ratio of charge pump 1 and charge pump 2 currents.
When the loop is out of lock, both charge pumps will be
enabled and will feed current to the loop amplifier to bring the
VCO to phase lock. The current from charge 2 will produce a
voltage drop across Rb, allowing operation of the lock detect
circuit and enabling charge pump 1. The value of Rb must be
chosen to give a voltage drop greater than 0·25V at the current
level programmed for charge pump 2. When phase lock is
achieved, there will be no charge pump current and therefore
the voltage at pin 25 will be equal to that on the virtual earth
point of the loop amplifier (2·5V), disabling charge pump 1.
Charge pump 1 should not be left open circuit when
enabled as this would prevent correct operation of the phase
detector. The output on pin 3 should be biased to half supply
with a pair of 4·7kΩ resistors connected across supplies.
When charge pump 2 is used to drive the loop amplifier, the
lock detect circuit will only give an out of lock indication when
large frequency changes are made or when a frequency
outside the range of the VCO is programmed. at other times
the loop amplifier is maintained at 2·5V by the action of the
loop filter components. Again, a resistor connected between
pin 25 and the loop amplifier, producing a voltage drop greater
than 0·25V at the charge current programmed will allow
sensitive out of lock detection.
When phase lock detection is required using charge
pump 1 only, charge pump 2 output should be biased to 2·5V,
using two equal value resistors, Ra, across the supply as
shown in Fig. 6c. A small capacitor, Cd, connected frompin 28
to ground may be used to reduce chatter at the lock detect
output. A detailed block diagram of the lock detect circuit is
shown in Fig. 3.
Choice of Loop Amplifier
The loop amplifier converts the charge pump current pulses
into a voltage of a magnitude suitable for driving the chosen
VCO. The choice of amplifier is determined by the voltage
swing required at the VCO to achieve the necessary range. In
most cases, an operational amplifier will be used to provide the
essential characteristcs of high input impedance, high gain
and low output impedance required in this application. A
simple discrete design could also be used as shown in Fig. 6d.
This arrangement can be particularly useful where the minimum
VCO control voltage must be close to ground and where
negative supplies are inconvenient. This form of amplifier is
not suitable for use with charge pump 2 when the lock detect
circuit is required.
When an operational amplifier is used in the inverting
configuration shown in Fig. 6a, the charge pump output is
connected directly to the virtual earth point and will therefore
operate a a voltage close to that set on the non-inverting input.
Normally, this operating point should be set at half supply
using a potential divider of two equal value resistors, Rx, but
if necessary the voltage can be set up to 1V higher or lower
without detrimental effect. When the lock detect function is
required on charge pump 2 however, the non-inverting input
must be at half supply.
The digital phase detector and charge pump in the
SP8861 produces bi-directional current pulses in order to
correct errors between the reference and the VCO divider
outputs. Once synchronisation is achieved, in theory no
further output from the charge pump should be required. In
practice, due to leakage currents and particularly the input
current of the amplifier, the capacitors in the loop filter will
gradually discharge, modifying the VCO control voltage and
requiring further outputs from the charge pump to restore
the charge. The effect of this continuous correction is to
frequency modulate the VCO frequency and thus produce
sidebands at the reference frequency. In order to reduce
this effect to a minimum, an amplifier with low input bias is
essential.
9
SP8861
C1
FROM PHASE
DETECTOR
R1
C1
R2
−
+
TO VCO
+
C2
Fig. 9 Standard form of second order loop filter
Fig. 10 Modified form of second order loop filter
LOOP CALCULATIONS
Many frequency synthesiser designs use a second order
loop with a loop filter of the form shown in Fig. 9.
In practice, an additional RC time constant (shown dashed
in Fig. 9) is often added to reduce noise from the amplifier. In
addition, any feedthrough capacitor or local decoupling at the
VCO will be added to the value of C2. These additional
components in fact form a third order loop and, if the values
are chosen correctly, the additional filtering provided can
considerably reduce the level of reference frequency sidebands
and noise without adversely affecting the loop settling time.
The calculations of values for both types of loop are shown
below.
Example
Calculate values for a second order loop with the following
parameters:
Frequency to be synthesised
= 800MHz
Reference frequency
=100kHz
800MHz
Division ration N
=
100kHz
= 8000
6
t1 = 0·079632p310
2
From equation (1),
(2p3500) 383103
∴t1 = 6·334µs
t2 = 230·7071
From equation (2),
2p3500
Second Order Loop
∴t2 = 450µs
For this filter, two equations are required to determine the
time constants t1 (= C1R1) and t2 (= C1R2); the equations are:
KK
t1 = u2 0
vn N
t2 =
2z
vn
…(1)
…(2)
where
Ku is the phase detector gain factor in V/radian
K0 is the VCO gain factor = 2p310MHz/V
N is the division ratio from VCO to reference frequency
vn is the natural loop frequency = 500Hz
z is the damping factor = 0·7071
The SP8861 phase detector is a current source rather than
a conventional voltage source and has a gain factor specified
in µA/radian. Since the equations deal with a filter where R1
is feeding the virtual earth point of an operational amplifier
from a voltage source, R1 sets the input current to the filter –
similar to the circuit shown in Fig. 10 – where a current source
phase detector is connected directly to the virtual earth point
of the operational amplifier.
The equivalent voltage gain of the phase detector can be
calculated by assuming a value for R1 and calculating a gain
in V/radian which would produce the set current.
The digital phase detector used in the SP8861 is linear
over a range of 2p radians and therefore the phase detector
gain is given by:
Phase detector current setting
µA/radian
2p
For R1 = 1kΩ and assuming a value of phase detector current
of 50µA, the phase detector gain is therefore:
50µA
Ku =
3103
2p
Ku =
Now, since t1 = C1R1 ,
and, since
t2 = C1R2 ,
This value can now be inserted in equation 1 to obtain a value
for C1 and equation 2 used to determine a value for R2.
C1 = 6·334310
103
∴C1 = 6·33nF
26
24
R2 = 4·5310 29
6·33310
∴R2 = 71kΩ
Third Order Loop
The third order loop is normally as shown in Fig. 11. Fig. 12
shows the circuit redrawn to use an RC time constant after the
amplifier, allowing any feedthrough capacitance on the VCO
line to be included in the loop calculations. Where the modified
form in Fig. 12 is used, it is advantageous to connect a small
capacitor CX of typically 100pF (shown dashed) across R2 to
reduce sidebands caused by the amplifier being forced into
non-linear operation by the phase comparator pulses
Three equations are required to determine the time
constants t1, t2, and t3, where
for Fig. 11
t1 = C1R1
t2 = R2 (C11C2)
t3 = C2R2
and for Fig. 12
t1 = C1R1
t2 = C1R2
t3 = C2R3
The equations are:
1
t1 =
t2 =
= 0·00796V/radian
10
−
PHASE
DETECTOR
R3
R2
t3 =
KuK0 11vn2 t22  2
vn2N 11vn2 t32 
1
…(3)
…(4)
vn2t32
1
2tan F0 1
cos F0
vn
…(5)
SP8861
Cx
C2
C1
C1
R2
R1
FROM
CHARGE
PUMP
FROM
CHARGE
PUMP
−
TO VCO
+
Fig. 11 Standard form of third order loop filter
−
R3
TO VCO
+
C3
Fig. 12 Modified form of third order loop filter
where Ku, K0, N and vn are as defined for the second order
loop and F0 is the phase margin, normally set to 45°. These
values can now be substituted in equation (3) to obtain a value
for C1 and in equations (4) and (5) to determine values for C2
and R2.
For Fig. 11,
t2 = R2 (C11C2)
For Fig. 12,
t3 = C2R2
Substituting for C2:
t2 = R2 C11t3  = R2 C11t3

Example
Calculate values for a third order loop with parameters as
for the second order loop and F0 = 45°.
From equation (5):
1
2tan 45°1
cos 45°
t3 =
500Hz32 p
=
R2
R1
or, R2=
R2 
t22t3
C1
7·6873102421·31831024
0·015331026
∴R2 = 41·627kΩ
=
0·4142
3161·6
t3 = C2R2 = t3
∴t3 = 131·8µs
R2
From equation (4):
1·31831024
41627
∴C2 = 3·17nF
=
t2 =
1
(500323p)231·31831024
∴t2 = 768·7µs
For Fig. 12,
Using these values in equation (3):
t1 =
where A =
23
7·96310 32p310MHz/V
80003(50032p)2
1
2
3[A]
11vn2 t22 
11vn2 t32 
t1 = C1R1
1·5331025
103
∴C1 = 0·0153nF
or, C1 =
t2 = C1R2
11(50032p)23(7·68731024)2
=
11(50032p)23(1·31831024)2
1
2
t1 = 500141·6 10  6·832 
7·896110 1·1714 
= 6·3343102632·415
∴t1 = 15·3µs
1·5331025
Now, since t1 = C1R1 and R1 =1kΩ, C1 =
103
∴C1 = 0·0153µF
7·68731024
1·5331028
∴R2 = 50·242kΩ
or, R2 =
t3 = C2R3
Since the values of C2 and R3 are independent of the other
components, either can be chosen and the other determined.
Assuming that R3 = 1kΩ, then
1·31831024
103
∴C2 = 0·01318µF
C2 =
11
http://www.mitelsemi.com
World Headquarters - Canada
Tel: +1 (613) 592 2122
Fax: +1 (613) 592 6909
North America
Tel: +1 (770) 486 0194
Fax: +1 (770) 631 8213
Asia/Pacific
Tel: +65 333 6193
Fax: +65 333 6192
Europe, Middle East,
and Africa (EMEA)
Tel: +44 (0) 1793 518528
Fax: +44 (0) 1793 518581
Information relating to products and services furnished herein by Mitel Corporation or its subsidiaries (collectively “Mitel”) is believed to be reliable. However, Mitel assumes no
liability for errors that may appear in this publication, or for liability otherwise arising from the application or use of any such information, product or service or for any infringement of
patents or other intellectual property rights owned by third parties which may result from such application or use. Neither the supply of such information or purchase of product or
service conveys any license, either express or implied, under patents or other intellectual property rights owned by Mitel or licensed from third parties by Mitel, whatsoever.
Purchasers of products are also hereby notified that the use of product in certain ways or in combination with Mitel, or non-Mitel furnished goods or services may infringe patents or
other intellectual property rights owned by Mitel.
This publication is issued to provide information only and (unless agreed by Mitel in writing) may not be used, applied or reproduced for any purpose nor form part of any order or
contract nor to be regarded as a representation relating to the products or services concerned. The products, their specifications, services and other information appearing in this
publication are subject to change by Mitel without notice. No warranty or guarantee express or implied is made regarding the capability, performance or suitability of any product or
service. Information concerning possible methods of use is provided as a guide only and does not constitute any guarantee that such methods of use will be satisfactory in a specific
piece of equipment. It is the user’s responsibility to fully determine the performance and suitability of any equipment using such information and to ensure that any publication or
data used is up to date and has not been superseded. Manufacturing does not necessarily include testing of all functions or parameters. These products are not suitable for use in
any medical products whose failure to perform may result in significant injury or death to the user. All products and materials are sold and services provided subject to Mitel’s
conditions of sale which are available on request.
M Mitel (design) and ST-BUS are registered trademarks of MITEL Corporation
Mitel Semiconductor is an ISO 9001 Registered Company
Copyright 1999 MITEL Corporation
All Rights Reserved
Printed in CANADA
TECHNICAL DOCUMENTATION - NOT FOR RESALE