Datasheet

SIDACtor ® Protection Thyristors
SLIC Protection
Battrax® Series - Dual Port Negative - MS-013
Pb e3
RoHS
Description
Dual port protection is provided by a programmable device
that is referenced to a negative voltage souce while internal
diodes provide protection from positive surge events.
Features and Benefits
• Low voltage overshoot
• Low on-state voltage
• Does not degrade surge
capability after multiple
surge events within
limit.
Agency Approvals
Agency
Agency File Number
E133083
• RoHS Compliant and
Lead-Free
• Dual-port protection
Pinout Designation
1
6
2
5
3
4
• Gate trigger tracking
device
• Pb-free E3 means 2nd
level interconnect is
Pb-free and the terminal
finish material is tin(Sn)
(IPC/JEDEC J-STD609A.01)
• TIA-968-A
• GR 1089 Intra-building
• TIA-968-B
• IEC 61000-4-5 2nd
edition
• ITU K.20/21 Enhanced
Level
6 (T2)
5 Ground
(-VREF) 2
• Integrated diode for
positive voltage surges
Applicable Global Standards
Schematic Symbol
(T1) 1
• Fails short circuit when
surged in excess of
ratings
• YD/T 1082
• ITU K.20/21 Basic Level
• YD/T 993
• GR 1089 Inter-building
• YD/T 950
Additional Information
4 (R2)
(R1) 3
Datasheet
Samples
Resources
Electrical Characteristics
Part Number
Marking
VDRM
@lDRM=5µA
VS
@100V/µs
V min
V max
IH
IS
mA min mA max
IT
VT
@IT=2.2 Amps
VF
Capacitance*
A max
V max
V max
pF min pF max
B1101UC4Lxx
B1101UC4
I-VREFI + I-1.2VI
I-VREFI + I-10VI
100
100
2.2
4
5
30
200
B1161UC4Lxx
B1161UC4
I-VREFI + I-1.2VI
I-VREFI + I-10VI
160
100
2.2
4
5
30
200
B1201UC4Lxx
B1201UC4
I-VREFI + I-1.2VI
I-VREFI + I-10VI
200
100
2.2
4
5
30
200
Notes:
- Absolute maximum ratings measured at TA= 25ºC (unless otherwise noted).
- Components are uni-directional
- All electrical characteristics shown are defined from Tip (pin 1 & 6) to Ground (pin 5) and
Ring (pin 3 & 4) to Ground (pin 5)
- Components are polarity sensitive and are not appropriate for positive ringing systems.
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/12/16
- VREF Max Value for the negative Battrax is -200 V.
- XX = Part Number Suffix: ‘TP’ (Tube Pack) or ‘RP’ (Reel Pack).
* Off-state capacitance (CO) is measured across pins 1 & 5, 3 & 5, 4 & 5, and 6 & 5
at 1 MHz with a 2V bias.
Battrax® Dual Port Neg Series
The Dual Port Negative Battrax® Protection Thyristor Series
are programmable SIDACtor® components designed to
protect SLICs (Subscriber Line Interface Circuit) from
damaging overvoltage transients.
SIDACtor ® Protection Thyristors
SLIC Protection
Surge Ratings
Series
IPP
ITSM
di/dt
0.2/310 1
0.5/700 2
2/10 1
2/10 2
8/20 1
1.2/50 2
10/160 1
10/160 2
10/560 1
10/560 2
5/320 1
9/720 2
10/360 1
10/360 2
10/1000 1
10/1000 2
5/310 1
10/700 2
50/60 Hz
A min
A min
A min
A min
A min
A min
A min
A min
A min
A min
A/µs max
50
500
400
200
150
200
175
100
200
50
500
C
Notes:
- Peak pulse current rating (IPP) is repetitive and guaranteed for the life of the product that remains in thermal equilibrium.
- IPP ratings applicable over temperature range of -40ºC to +85ºC (IPP rating assumes VREF equals - 48 V)
- The component must initially be in thermal equilibrium with -40°C < TJ < +150°C
1 Current waveform in µs
2 Voltage waveform in µs
Thermal Considerations
Package
Symbol
Modified MS-013
-40 to +125
°C
TS
Storage Temperature Range
-65 to +150
°C
R0JA
Thermal Resistance: Junction to Ambient
60
°C/W
4
3
Unit
Operating Junction Temperature Range
1
2
Value
TJ
6
5
Parameter
V-I Characteristics
tr x td Pulse Waveform
IPP – Peak Pulse Current – %IPP
+I
V
VREF
VS VDRM
IF
VT
-V
IDRM
+V
IH
IS
IT
IPP
PIN
CONNECTED TO GROUND
Pin 51-2:
PIN
TOGROUND
VREF
PIN22CONNECTED
CONNECTED TO
-I
Waveform = tr x td
50
Half Value
0
0
td
tr
t – Time (µs)
PIN 3 CONNECTED TO VREF
Normalized VS Change vs. Junction Temperature
Normalized DC Holding Current vs. Case Temperature
10
IH
8
6
25 °C
4
2
IH (TC = 25ºC)
2.0
14
12
Ratio of
Percent of VS Change – %
tr = rise time to peak value
td = decay time to half value
Peak
Value
100
0
-4
-6
1.8
1.6
1.4
1.0
0.8
0.6
0.4
-8
-40 -20
0
20 40 60 80 100 120 140 160
Junction Temperature (TJ) – °C
25°C
1.2
-40
-20
0
20
40
60
80
100 120 140
160
Case Temperature (TC) - ºC
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/12/16
SIDACtor ® Protection Thyristors
SLIC Protection
Soldering Parameters
Pb-Free assembly
(see Fig. 1)
+150°C
+200°C
60-180 secs.
- Temperature Min (Ts(min))
- Temperature Max (Ts(max))
Pre Heat
- Time (Min to Max) (ts)
Average ramp up rate (Liquidus Temp (TL)
to peak)
3°C/sec. Max.
TS(max) to TL - Ramp-up Rate
3°C/sec. Max.
Reflow
- Temperature (TL) (Liquidus)
+217°C
- Temperature (tL)
60-150 secs.
Peak Temp (TP)
+260(+0/-5)°C
Time within 5°C of actual Peak Temp (tp)
30 secs. Max.
Ramp-down Rate
6°C/sec. Max.
Time 25°C to Peak Temp (TP)
8 min. Max.
Do not exceed
+260°C
TP
tP
Critical Zone
TL to TP
Ramp-up
TL
TS(max)
tL
Ramp-down
Preheat
TS(min)
tS
25
time to peak temperature
(t 25ºC to peak)
Time
Environmental Specifications
Physical Specifications
Lead Material
Copper Alloy
Terminal Finish
100% Matte-Tin Plated
Body Material
Figure 1
Temperature
Reflow Condition
UL Recognized epoxy meeting
flammability classification V-0
Battrax Series Dual Port Negative MS-013 Part Numbering.eps
For pg. 142
High Temp Voltage
Blocking
80% Rated VDRM (VDC Peak ) +125°C or +150°C,
504 or 1008 hrs. MIL-STD-750 (Method 1040)
JEDEC, JESD22-A-101
Temp Cycling
-65°C to +150°C, 15 min. dwell, 10 up to 100
cycles. MIL-STD-750 (Method 1051) EIA/JEDEC,
JESD22-A104
Biased Temp &
Humidity
52 VDC (+85°C) 85%RH, 504 up to 1008 hrs. EIA/
JEDEC, JESD22-A-101
High Temp Storage
+150°C 1008 hrs. MIL-STD-750 (Method 1031)
JEDEC, JESD22-A-101
Low Temp Storage
-65°C, 1008 hrs.
Thermal Shock
0°C to +100°C, 5 min. dwell, 10 sec. transfer,
10 cycles. MIL-STD-750 (Method 1056) JEDEC,
JESD22-A-106
Autoclave (Pressure
Cooker Test)
+121°C, 100%RH, 2atm, 24 up to 168 hrs. EIA/
JEDEC, JESD22-A-102
Resistance to Solder
Heat
+260°C, 30 secs. MIL-STD-750 (Method 2031)
Moisture Sensitivity
85%RH, +85°C, 168 hrs., 3 reflow cycles
(+260°C Peak). JEDEC-J-STD-020, Level 1
Level Part Marking Drawing_2009-03-05.eps
MS-013
Part Marking
Part Numbering
B1 xx 1 U C 4 L xx
TYPE
B1: Negative Battrax SIDACtor
HOLDING CURRENT
10: 100 mA
20: 200 mA
16: 160 mA
CONSTRUCTION VARIABLE
PACKING OPTIONS
RP: Reel Pack
TP: Tube Pack
RoHS COMPLIANT
DUAL PORT
IPP RATING
XXXXXXXX
Part Marking Code
(Refer to Electrical Characteristics Table)
Date Code
XXXXX
PACKAGE TYPE
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/12/16
SIDACtor ® Protection Thyristors
SLIC Protection
Dimensions — MS-013
Dimensions
0.065
(1.65)
Pad Outline
C
D
J
7º TYP
A
Dimension are in inches
(and millimeters).
0.059
(1.50)
E
7º TYP
A
B
C
D
E
F
G
H
J
K
BSC*
0.460
(11.68)
0.138
(3.50)
G
Burr Side
H
96º
A
Mold Split
Line
4º
A
7º TYP
BSC*
F
7º TYP
MIN Length
of Flat
K
Detail A
B
Inches
Millimeters
Min
Max
Min
Max
0.360
0.352
0.400
0.043
0.047
0.293
0.289
0.089
0.041
0.020
0.133
0.364
0.356
0.412
0.045
0.055
0.297
0.293
0.093
0.049
--0.143
9.14
8.94
10.16
1.09
1.19
7.44
7.34
2.26
1.04
0.51
3.38
9.25
9.04
10.46
1.13
1.40
7.54
7.44
2.36
1.24
--3.63
* BSC = Basic Spacing between Centers
Packing Options
Package Type
U
Description
Quantity
Added Suffix
Industry Standard
Modified MS-013 6-pin
Tape and Reel Pack
1500
RP
EIA-481-D
Modified MS-013 6-pin
Tube Pack
500
(50 per tube)
TP
N/A
Tape and Reel Specification — MS-013
.157
(4.0)
.630
(16.0)
.472
(12.0)
12.99
(330)
.512 (13.0) Arbor
Hole Dia.
Dimensions are in inches
(and millimeters)
0.700
(17.8)
Direction of Feed
Tube Pack Specification — MS-013
Message Location
.045
(1.14)
.310
(7.87)
90˚
.165
(4.19)
6
Interior of the Tube
.150
(3.81)
.225
(5.72)
.525
(13.34)
.020 ± .005 WALL TYP.
(0.51 ± 0.13)
.108
(2.74)
.005 A
20.000 ± .030
(508.00 ± 0.76)
.110
(2.79)
A
Dimensions are in inches
(and millimeters)
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 05/12/16