SKKD 212/16
Absolute Maximum Ratings
Symbol
Conditions
Values
Unit
A
Recitifier Diode
Tc = 85 °C
213
Tc = 100 °C
165
A
Tj = 25 °C
6600
A
Tj = 135 °C
5500
A
Tj = 25 °C
217800
A²s
Tj = 135 °C
151250
A²s
VRSM
1700
V
VRRM
1600
V
-40 ... 135
°C
-40 ... 125
°C
1 min
3000
V
1s
3600
V
IFAV
IFSM
i2t
SEMIPACK® 2
Rectifier Diode Modules
sin. 180°
10 ms
10 ms
Tj
Module
Tstg
SKKD 212/16
Visol
Features
Characteristics
• Heat transfer through aluminium oxide
ceramic isolated metal baseplate
• Hard soldered joints for high reliability
• UL recognized, file no. E63532
Symbol
Typical Applications*
• Non-controllable rectifiers for AC/AC
converters
• Line rectifiers for transistorized AC
motor controllers
• Field supply for DC motors
a.c.; 50 Hz; r.m.s.
Conditions
min.
typ.
max.
Unit
Diode
VF
Tj = 25 °C, IF = 500 A
1.40
V
V(TO)
Tj = 135 °C
0.75
V
rT
Tj = 135 °C
1.05
m
IRD
Tj = 135 °C, VRD = VRRM
Rth(j-c)
Rth(j-c)
cont.
sin. 180°
9
mA
per chip
0.18
K/W
per module
0.09
K/W
per chip
0.18
K/W
per module
0.09
K/W
Module
Rth(c-s)
chip
0.1
K/W
module
0.05
K/W
Ms
to heatsink M5
4.25
5.75
Nm
Mt
to terminals M6
4.25
5.75
Nm
5 * 9,81
m/s²
a
w
165
g
SKKD
© by SEMIKRON
Rev. 4 – 03.09.2013
1
SKKD 212/16
Fig. 11L: Power dissipation per diode vs. forward current
Fig. 11R: Power dissipation per diode vs. ambient
temperature
Fig. 12L: Power dissipation of two modules vs. direct
current
Fig. 12R: Power dissipation of two modules vs. case
temperature
Fig. 13L: Power dissipation of three modules vs. direct
current
Fig. 13R: Power dissipation of three modules vs. case
temperature
2
Rev. 4 – 03.09.2013
© by SEMIKRON
SKKD 212/16
Fig. 14: Transient thermal impedance vs. time
Fig. 15: Forward characteristics
Fig. 16: Surge overload current vs. time
© by SEMIKRON
Rev. 4 – 03.09.2013
3
SKKD 212/16
SKKD
SEMIPACK 2
This is an electrostatic discharge sensitive device (ESDS), international standard IEC 60747-1, Chapter IX
* The specifications of our components may not be considered as an assurance of component characteristics. Components have to be tested
for the respective application. Adjustments may be necessary. The use of SEMIKRON products in life support appliances and systems is
subject to prior specification and written approval by SEMIKRON. We therefore strongly recommend prior consultation of our staff.
4
Rev. 4 – 03.09.2013
© by SEMIKRON