Technical data
Reference:
Lamp:
System wattage:
Lamp wattage:
Line voltage:
Voltage range:
Line frequency:
Line current:
PT 20/220-240 S
HCI-TC 20, HCI-TF 20
22 W ± 0,5 W
20 W
220 – 240 VAC
198 – 264 VAC
50 / 60 Hz
0,17 Aeff @ 230 VAC
Power factor λ:
Inrush current
Max. no. of ECG @ circuit breakers 10 A
(B type)
Max. no. of ECG @ circuit breakers 16 A
(B type)
Operating frequency (50 / 60 Hz Line
frequency):
U-OUT between LH and LL
U-OUT between LH / LL and PE
Ambient temperature ta:
Max. temperature at point tc
ECG life time:
Min. ECG-reset time (by mains interrupt)
Wire cross section input / output line:
Wire stripping:
Max. wiring length ECG/lamp:
Max. capacity of wire ECG/lamp
Ignition voltage:
Limited ignition time:
Dimensions (l x b x h):
Distance mounting wholes (l1 x b1):
Weight:
Safty:
Radio interference suppression:
Harmonics of line current:
Immunity:
VDE-sign (safty):
VDE-EMC-sign:
< 0,61
21 A / 140 µs @ 50%
11
18
130 Hz
250 V
250 V
-25 °C to +55 °C
+75 °C
40.000 h (@ tc max.) 1)
1 sec
Max. 1,5 mm²
8,5 – 9,5 mm
0,60 m
50 pF
4 kV
23 min.
97 mm x 43 mm x 31 mm
88 mm x 34 mm
≈ 90 g
EN 61347-1 / IEC 61347-2-12
EN 55015
EN 61000-3-2
EN 61547
40023522
40023506
Prüfzeichen:
;
1) with max. 8% breakdown for operation at max. tc
2008-10-22
page 1 of 2
,
,
POWERTRONIC

PT 20/220-240 S
For metal halide lamps 20 W
Technical
Information
Edition: Oct. 2008
Subject to change
Geometry
Product number:
Reference
PT 20/220-240 S
EAN 10
4008321 916181
EAN 40
4008321 916198
Thermal characteristics:
Ballast losses and lamp heat radiation can lead to heat accumulation in a complete closed case.
Therefore it is necessary to ensure, that the temperature at the measuring point tc of POWERTRONIC
does not exceed the maximum value.
Attention:
For safety reasons disconnect the device before replacing the lamp.Terminals for protective earth not
suitable for any through connection.
Installation by qualified electricians only.