POWERTRONIC Technical Information

POWERTRONIC

for 2 metal halide lamps 35W
PTi 2x35/220-240 I
Technical
Information
Edition: Feb 2006
Subject to change
Technical data:
Reference:
For 2 lamps (wattage):
PTi 2x35/220-240 I
HCI-T 35 W, HCI-TC 35 W, HCI-E/P 35 W, HCI-PAR 35 W
and other similar commercially available lamps
Line voltage(AC):
220 - 240 V
Perm. voltage fluctuations(AC):
198 - 264 V
Line frequency:
50 / 60 Hz
Line current (230V):
0,37 A
Power factor:
>0,95c
Inrush current:
40 A/250 µs
System wattage:
86 W ± 4 W
Losses:
8W
Lamp wattage:
2 x 39 W ± 2 W
Operating frequency:
165 Hz
2 separate independent lamp circuits for discrete lamp operation
Microprocessor:
Reliable cut off of defective lamps
Overheating protection thanks to power reduction and cut off above T at tc > 80 °C
Min. ECG-reset time (by mains interrupt)
0,5 s
Ignition voltage:
max. 4,5 kVp
Max. wiring length ECG per lamp:
1,5 m
Max. capacity of wire ECG per lamp:
120 pF
Limited ignition time:
18 min
Max. temperature at point tc
75 °C
Max. ambient temperature ta
55 °C
Min. ambient temperature ta
-25 °C
Life time:
50000 h (ta = 50°C; T = 70 °C at t c)
40000 h (ta = 55°C; T = t c)
Dimensions *:
180mm x 83mm x 32mm
Weight:
≈ 290 g
Terminal: permitted wiring cross section
0,5-2,5 mm2
Cable diameter:
min. 7mm – max. 11mm
Cable mains:
e.g.: H03VV-F, H05 VV-F, NYM: 2x0,75; 2x1,5; 3x0,75; 3x1,5; 3x2,5
Cable output:
e. g.: SIHY- Cu vz: 3x0,75, 3x1,5
Radio interference suppression:
EN 55015
Harmonics of line current:
EN 61000-3-2
Immunity:
EN 61547
Safety:
acc. EN 61347-1
acc. EN 61347-2-12
VDE-Safety approval:
40016889
VDE-EMC-sign:
40004500
*See drawing
POWERTRONIC

for 2 metal halide lamps 35W
PTi 2x35/220-240 I
Technical
Information
Edition: Feb 2006
Subject to change
Thermal characteristics:
Ballast losses and lamp heat radiation can lead to heat accumulation in a complete closed case.
Therefore it is necessary to ensure, that the temperature at the measuring point tc does not exceed
the maximum value.
Attention:
For safety reasons disconnect the device before replacing the lamp.
Installation by qualified electricians only.