POWERTRONIC PT-FIT 50/220-240 S Technical Information Edition: June 2011 For metal halide lamps 50 W Subject to change Technical data Reference: Lamp: System wattage: Lamp wattage: Ballast efficiency: Line voltage: Voltage range: Line frequency: Line current: Power factor : Inrush current: Max. no. of ECG @ circuit brakers 10 A (B Type): Max. no. of ECG @ circuit brakers 16 A (B Type): Max. no. of ECG @ circuit brakers 16 A (B Type) in combination with EBN-OS: Protective conductor current: Operating frequency (50/60 Hz line frequency): U-OUT: Max. working voltage between LH and LL: Max. working voltage between LL/LH and PE: Ambient temperature ta: Max. temperature at tc test point: ECG life time: Overheating protection: Min. ECG reset time (by mains interrupt): Wire cross section input / output line: Wire stripping: Max. wire length ECG/lamp: Max. capacitance of wire ECG/lamp: Max. ignition voltage: Limited ignition time: Dimensions (l x w x h): Distance mounting holes (l1 x w1): Weight: Safety: Radio interference suppression: Harmonics of line current: Immunity: VDE-sign (safety): VDE-EMC-sign: PT-FIT 50/220-240 S HCI 50 W and other similar commercially available lamps 54.5 W 1.5 W 50 W 1.5 W ~ 92 % 220 – 240 VAC 198 – 264 VAC 50/60 Hz 0.24 Aeff @ 230 VAC > 0.95 max. 45 A / 250 µs @ 50% 7 13 32 0.3 mArms 200/240 Hz 250 V 250 V 250 V -15 °C to +60 °C +85 °C 30000 h (@ tc max.) 1) Power reduction and shutdown at T at the tc point > 85 °C 0.5 sec 0.5 – 1.5 mm² without ferrule 0.5 – 1.0 mm2 with ferrule 8.5 – 9.5 mm 1.50 m 120 pF 4.5 kV 20 min 110 mm x 75 mm x 30 mm 99 mm x 64 mm ≈ 257 g EN 61347-2-12 / IEC 61347-2-12 EN 55015 / CISPR 15 EN 61000-3-2 / IEC 61000-3-2 EN 61547 / IEC 61547 40020649 40027499 Approval marks: 1) with max. 10% failure rate at max. tc 2011-11-25 page 1 of 3 POWERTRONIC PT-FIT 50/220-240 S Technical Information For metal halide lamps 50 W Edition: June 2011 Subject to change Geometry Product number: Reference PT-FIT 50/220-240 S 2011-11-25 EAN 10 4008321 648693 page 2 of 3 EAN 40 4008321 648709 POWERTRONIC PT-FIT 50/220-240 S Technical Information Edition: June 2011 For metal halide lamps 50 W Subject to change Thermal characteristics Ballast losses and lamp heat radiation can lead to heat accumulation in a complete closed case. Therefore it is necessary to ensure, that the temperature at the measuring point tc does not exceed the maximum value. Attention! For safety reasons disconnect the device before replacing the lamp! Any conductive material must have a minimum distance of 4mm to the front of the terminal block. Wiring diagram Installation by qualified electricians only. Terminals for protective earth not suitable for any through connection. PE Setup for built-in or integral ECG Mains ECG PT-FIT 50/220-240 S 2011-11-25 page 3 of 3