POWERTRONIC Technical Information for HID lamps 70 W PTU 70/220-240 Edition: Juli 2005 Subject to change Technical Data: Reference: For lamp (wattage): PTU 70/220-240 HCI-TS 70 W, HCI-T 70 W, HCI-TC 70 W, HCI-PAR 70 W, HCI-E/P 70 W, HQI-TS 70 W, HQI-T 70 W, HQI-E 70 W (NAV on request) and other similar commercially available lamps Line voltage: 220 - 240 V∼ Perm. voltage fluctuations: 198-254 V∼ Line frequency: 50 / 60 Hz Line current at 230V: 0,36 A Power factor: >0.95c Inrush current: 45 A/130 µs System wattage: 80 W ± 3 W Losses: 7W±1W Lamp wattage: 73 W ± 3 W Operating frequency: 130 Hz Microprocessor reliable cut off of defective lamps or for tc > 83°C Time to reset the ECG (by mains interrupt) > 0,5 s Ignition voltage: 5 kVp Electronic unit/Ignition unit: 3,0 m (Max. capacity of wire ECG/lamp 200 pF) Ignition time is limited: 18 min Max. temperature in point tc 80 °C Max. ambient temperature ta 50 °C Min. ambient temperature ta: -25 °C Overheating protection power reduction at tc= 80°C, switch off at t c = 83°C Dimensions*) 134 mm x 88 mm x 39 mm Weight ≈ 350 g Terminal: permitted wiring cross section 0,5-4mm2 Radio interference suppression: EN 55015 Harmonics of line current: EN 61000-3-2 Immunity: EN 61547 Approval: Safety according to EN 61347-1;…-2-1;…-2-3 VDE-registration-no.: 40004469 Cable Clamp Reference PTU-SR mains: mains looping possible,use only one terminal for earthing cable: e.g.: H03VV-F 2 x 0,5; 2x0,75; 2x1,0; 2x1,5 3x0,50; 3x0,75; 3x1,0; 3x1,5 NYM 3x1,5 Output: *)See drawing ∅ max.10 mm e.g.: SIHY-Cu vz 3x0,75 POWERTRONIC Technical Information for HID lamps 70 W PTU 70/220-240 Edition: Juli 2005 39 Subject to change tc 88 134 78 1 16 120 PTU 70/220-240 with cable clamp Thermal characteristics: Ballast losses and lamp heat radiation can lead to heat accumulation in a complete closed case. Therefore it is necessary to ensure, that the temperature at the measuring point tc does not exceed the maximum value. Attention: Disconnect the device before replacing the lamp. Stand-alone installation possible: The cable clamp with covering plate is available separately. For ceiling cut outs of > 94 mm.