POWERTRONIC for 2 metal halide lamps 35W PTi 2x35/220-240 S Technical Information Edition: Jan 2006 Subject to change Technical data: Reference: For 2 lamps (wattage): PTi 2x35/220-240 S HCI-T 35 W, HCI-TC 35 W, HCI-E/P 35 W, HCI-PAR 35 W and other similar commercially available lamps Line voltage(AC): 220 - 240 V Perm. voltage fluctuations(AC): 198 - 264 V Line frequency: 50 / 60 Hz Line current (230V): 0,37 A Power factor: >0,95c Inrush current: 40 A/250 µs System wattage: 86 W ± 4 W Losses: 8W Lamp wattage: 2 x 39 W ± 2 W Operating frequency: 165 Hz 2 separate independent lamp circuits for discrete lamp operation Microprocessor: Reliable cut off of defective lamps Overheating protection thanks to power reduction and cut off above T at tc > 80 °C Min. ECG-reset time (by mains interrupt) 0,5 s Ignition voltage: max. 4,5 kVp Max. wiring length ECG per lamp: 1,5 m Max. capacity of wire ECG per lamp: 120 pF Limited ignition time: 18 min Max. temperature at point tc 80 °C Max. ambient temperature ta 55 °C Min. ambient temperature ta -25 °C Life time: 50000 h (ta = 50°C; T = 75 °C at t c) 40000 h (ta = 55°C; T = t c) Dimensions *: 135mm x 75mm x 30mm Weight: ≈ 290 g Terminal: permitted wiring cross section 0,5-2,5 mm2 Radio interference suppression: EN 55015 Harmonics of line current: EN 61000-3-2 Immunity: EN 61547 Safety: acc. EN 61347-2-12 VDE-Safety approval: 40016889 VDE-EMC-sign: 40004500 *See drawing POWERTRONIC for 2 metal halide lamps 35W PTi 2x35/220-240 S Technical Information Edition: Jan 2006 Subject to change Thermal characteristics: Ballast losses and lamp heat radiation can lead to heat accumulation in a complete closed case. Therefore it is necessary to ensure, that the temperature at the measuring point tc does not exceed the maximum value. Attention: For safety reasons disconnect the device before replacing the lamp. Terminals for protective earth not suitable for any through connection. Installation by qualified electricians only.