MA-COM DS

Flatpack Four-Way Power Divider
25 - 1000 MHz
DS-324
V2.00
Features
●
●
FP-5
0.5 dB Typical Midband Insertion Loss
38 dB Typical Midband Isolation
1.2:1 Typical Midband VSWR
Guaranteed Specifications1
Frequency Range
(from -55°C to +85°C)
25-1000 MHz
Insertion Loss
(Less Coupling)
25-500 MHz
25-1000 MHz
Isolation
25-1000 MHz
20 dB Min
Amplitude Balance 25-1000 MHz
0.25 dB Max
Phase Balance
25-500 MHz
500-1000 MHz
VSWR (All Ports)
In
Out
0.75 dB Max
1.0 dB Max
3° Max
6° Max
1.3:1 Max
1.4:1 Max
Dimensions in ( ) are in mm.
Unless Otherwise Noted: .xxx = ± 0.010 (.xx = ± 0.25)
.xx = ± 0.02 (.x = ± 0.5)
Weight (approx.): 0.21 ounces 6 grams
Typical Performance
Operating Characteristics
Impedance
Maximum Power Rating
or Input Power
INSERTION LOSS
50 Ohms Nominal
Internal Load Dissipation
LOSS (dB)
1.0 Watt Max
0.05 Watt Max
Environmental
MIL-STD-883 screening available.
Pin Configuration
IN; P4
Outputs; P8, P10, P12 & P14
All other pins and case are ground
1.0
7.0
0.75
6.75
0.5
6.5
0.25
10
100 300
500
1000
6.25
1500
FREQUENCY MHz
1. All specifications apply with 50 ohm source and load impedance.
ISOLATION (dB)
ISOLATION
Ordering Information
Model Number
DS-324 PIN
30
Package
Flatpack
50
40
30
20
10
30
100 300
500
1000
1500
FREQUENCY MHz
VSWR
VSWR
1.6
1.4
1.2
1.0
10
30
100 300
500
1000
FREQUENCY MHz
M/A-COM Division of AMP Incorporated ■ North America: Tel. (800) 366-2266, Fax (800) 618-8883 ■ Asia/Pacific: Tel. +85 2 2111 8088, Fax +85 2 2111 8087
■ Europe: Tel. +44 (1344) 869 595, Fax +44 (1344) 300 020
www.macom.com
AMP and Connecting at a Higher Level are trademarks.
Specifications subject to change without notice.
6-34
1500
TOTAL TRANSMISSION