ETC DS319

Two-Way Power Divider
10 - 500 MHz
DS-109/319/DSS-333
V2.00
FP-2
Features
●
●
●
1° Phase Balance Max
35 dB Typical Midband Isolation
1.1 Typical Midband VSWR
PIN 0.015 DIA ±0.005
(0.038 ±0.13)
8 PLACES
Guaranteed Specifications*
(From -55°C to +85°C)
MODEL
DSS-333
DS-109
Frequency Range
10-500
10-500 10-500 MHz
0.6
0.6 dB Max
0.6 0.9 dB Max
Isolation
25
25
Phase Balance
VSWR (All Ports)
10-200
10-500
2
3
4
5
6
7
8
0.385 ± 0.020
(9.8 ± 0.5)
0.080 (2.0)
0.100 (2.5)
0.250 (6.3)
25 dB Min
0.15 dB Max
0.15 0.2 dB Max
0.15
1
DS-319
Insertion Loss (Less coupling)
10-200 MHz
10-500 MHz
Amplitude Balance
10-200
10-500
0.312 MIN TYP
(7.9 MIN)
1°
2°
1° Max
1.3:1
1.4:1
1.3:1 Max
1.6:1 Max
0.51
(12.9 ±0.5)
0.350 (8.9)
0.150 MAX
(3.8 MAX)
0.060 (1.5)
Operating Characteristics
Impedance
Dimensions in ( ) are in mm.
Unless Otherwise Noted: .xxx = ±0.010 (.xx = ±0.25)
.xx = ±0.02 (.x = ±0.5)
WEIGHT (APPROX.): 0.09 OUNCES 2.5 GRAMS
50 Ohms Nominal
Maximum Power Rating
Or Input Power
1 Watt Max
Internal Load DIssipation
0.05 Watts Max
Environmental
MIL-STD-202 screening available.
DS-109
DS-319
DSS-333
TO-8-2
Pin Configuration
ΣIN; P1, Output C; P4
Output D; P8,
Case and all others pins ground.
ΣIN; P5, Output ‘C’; P8,
Output ‘D’; P2
All others pins are ground.
ΣIN; P1, Output ‘C’; P2,
Output ‘D’; P4
Case and all others pins are ground.
* All specifications apply with 50 ohm source and load impedance.
Ordering Information
Model No.
DS-109 PIN
DS-319 PIN
DSS-333 PIN
Package
Flatpack
TO-8-2
Surface Mount
Dimensions in ( ) are in mm.
Unless Otherwise Noted: .xxx = ±0.010 (.xx = ±0.25)
.xx = ±0.02 (.x = ±0.5)
Bottom of Case is AC ground.
M/A-COM Division of AMP Incorporated ■ North America: Tel. (800) 366-2266, Fax (800) 618-8883 ■ Asia/Pacific: Tel. +85 2 2111 8088, Fax +85 2 2111 8087
■ Europe: Tel. +44 (1344) 869 595, Fax +44 (1344) 300 020
www.macom.com
AMP and Connecting at a Higher Level are trademarks.
Specifications subject to change without notice.
6-20
DS-109/319
Two-Way Power Divider
V2.00
Typical Performance
INSERTION LOSS
ISOLATION
VSWR
SF-1
M/A-COM Division of AMP Incorporated ■ North America: Tel. (800) 366-2266, Fax (800) 618-8883 ■ Asia/Pacific: Tel. +85 2 2111 8088, Fax +85 2 2111 8087
■ Europe: Tel. +44 (1344) 869 595, Fax +44 (1344) 300 020
www.macom.com
AMP and Connecting at a Higher Level are trademarks.
Specifications subject to change without notice.
6-21