Datasheet

G9EC-1-B-AQ
DC Power Relay (200A type)
Capable of Interrupting Highvoltage, High-current Loads
• A compact relay (L98 x W44x H86.7mm) capable of
switching DC400V, 200A. (Capable of interrupting
max. DC400V, 1,000A)
• The switching section and driving section are
gas-injected and hermetically sealed, allowing
these compact relays to interrupt high-current.
The sealed construction also achieves no arc
space, space saving, and helps to ensure safe
applications. In addition, the contacts have a
high contact reliability that is unaffected by ambient atmosphere.
• Downsizing of parts and optimum design allow
no restrictions on the mounting direction.
■ Type standard
G9EC-@-@-@-@
➀ ➁ ➂ ➃
➀
➁
Classification
Symbol
Number of contact poles
1
Contact structure
➂
Coil terminal form
➃
Automotive use
Symbol Meaning of the symbol
1 pole
Blank
1a contact
B
M3.5 screw terminal
Blank
Lead wires
AQ
Available for automotive use
■ Classification
Terminal form
Classification
Coil terminals
Contact terminals
Screw terminals
Switching / current
conduction type
Contact structure
Rated coil voltage
1a
DC12V
DC24V
Screw terminals
Lead wires
Type name
G9EC-1-B-AQ
G9EC-1-AQ
DC Power Relay
Note:1. Come with two M8 nuts for main terminals (contacts).
2. Come with two M3.5 screws for screw-type coil terminal products.
3. If you are interested in a connector joint for coil terminal, please contact our sales representatives.
■ Ratings
● Operation coil
Rated voltage
(V)
Rated current
(mA)
Coil resistance
()
DC 12
583
20.6
DC 24
292
82.3
Operating voltage
(V)
Release voltage
(V)
Maximum voltage
(V)
Power consumption
(W)
75% or less of rated
voltage
8% or more of rated
voltage
130% of rated
voltage
(at 23C within
10min.)
Approx. 7
Note:1. Values of the rated current and the coil resistance are at coil temperature of +23C, and have a tolerance of ±10%.
2. The figures for the operating characteristics are at a coil temperature of 23C.
3. Value of the maximum voltage is the maximum voltage that can be applied to the relay coil.
● Switching area
Item
Rated load
Resistance load
G9EC-1(-B)-AQ
DC400V 200A
Rated current
200A
Maximum switching voltage
400V
Maximum switching current
200A
Please confirm Omron Safety Precautions for all automotive relays first.
Omron can not guarantee automotive relays before finish making a contract with product specifications.
G9EC-1-B-AQ
DC Power Relay (200A type)
■ Performance
Item
G9EC-1(-B)-AQ
Contact resistance *1
30 m or less (Typ. 0.2m)
Contact voltage drop
0.1V or less (at 200A)
Operating time
50 ms or less
Release time
30 ms or less
Insulation
resistance*2
Withstand voltage
Vibration tolerance
Shock resistance
Between coil and contacts
1,000 M or more
Between homopolar contacts
1,000 M or more
Between coil and contacts
AC2,500V for 1min.
Between homopolar contacts
AC2,500V for 1min.
Durability
5 to 200 to 5Hz Single amplitude 0.75mm (Acceleration: 2.94 to 88.9m/s2)
Malfunction
5 to 200 to 5Hz Single amplitude 0.75mm (Acceleration: 2.94 to 88.9m/s2)
Durability
490 m/s2
Malfunction
200 m/s2
Mechanical endurance *3
Electrical endurance (Resistance load) *4
Short time carry current
Maximum interruption current
Overload interruption
Reverse polarity interruption
200,000 times or more
DC400V 200A 3,000 times or more
300A (for 15 min)
DC400V 1,000A (10 times)
DC400V 700A (40 times or more)
DC200V 200A (1,000 times or more)
Minimum load current
1A
Ambient temperature
40 to +85C (with no icing or condensation)
Ambient humidity
5% to 85%RH
Weight (including accessories)
Approx. 650g
All values above are in early time under an ambient temperature of +23C unless stated.
Measurement condition: By voltage drop method at DC5V 1A.
Measurement condition: By insulation resistance at DC500V.
Test condition / Switching frequency: 3,600 times/hour.
Test condition / Switching frequency: 60 times/hour.
DC Power Relay
Note:
*1.
*2.
*3.
*4.
Please confirm Omron Safety Precautions for all automotive relays first.
Omron can not guarantee automotive relays before finish making a contract with product specifications.
G9EC-1-B-AQ
DC Power Relay (200A type)
■ Dimensions (Unit: mm)
●Relay with Screw Terminals
G9EC-1-B-AQ
Terminal arrangement /
Internal connections
(BOTTOM VIEW)
1(+)
7
32
44
2-M3.5
2(−)
2
7
28.6
Hole: 2-φ6.2
8
Note: Be sure to connect terminals with the
correct polarity. Coils do not have polarity.
72
86
98
Mounting holes
(BOTTOM VIEW)
2-M8
26
Hole: 2-M6 or φ6.5
1(+)
2(-)
Size (mm)
Tolerance (mm)
to 10
±0.3
10 to 50
±0.5
50 to
±1
7
G9EC-1-B-AQ
12VDC
8
MADE IN JAPAN
44.2
(Coil terminal
height)
86.2
70.2
(Terminal height)
86±0.1
Lot No. 2360Y1-0001
10.5
32±0.1
●Relay with Lead Wires
G9EC-1-AQ
Terminal arrangement /
Internal connections
(BOTTOM VIEW)
1(+)
32
44
2(−)
2
7
28.6
Hole: 2-φ6.2
8
Note: Be sure to connect terminals with the
correct polarity. Coils do not have polarity.
72
86
98
26
(10)
230±20
Mounting holes
(BOTTOM VIEW)
2-M8
Hole: 2-M6 or φ6.5
1(+)
2(-)
Size (mm)
Tolerance (mm)
7
8
G9EC-1-AQ
12VDC
DC Power Relay
MADE IN JAPAN
to 10
±0.3
10 to 50
±0.5
50 to
±1
86.2
70.2
(Terminal height)
86±0.1
Lot No. 2360Y1-0001
10.5
32±0.1
Please confirm Omron Safety Precautions for all automotive relays first.
Omron can not guarantee automotive relays before finish making a contract with product specifications.