ARL2505 THRU ARL256

BUTTON AUTOMOTIVE RECTIFIER
ARL2505 THRU ARL256
ARSL2505 THRU ARSL256
50 to 600 Volts
CURRENT
25.0 Amperes
AR-L
FEATURES
•
•
•
•
VOLTAGE RANGE
ARS-L
0.346(8.8)DIA
0.327(8.2)TYP
0.409(10.4)DIA
0.382(9.7)TYP
Low Leakage
Low forward voltage drop
High current capability
High forward surge current capacity
0.051(1.3)DIA
0.047(1.2)TYP
0.051(1.3)DIA
0.047(1.2)TYP
1.0(25.4)
MIN
1.0(25.4)
MIN
MECHANICAL DATA
•
•
•
•
•
•
•
0.252(6.4)
0.236(6.0)
0.252(6.4)
0.236(6.0)
Technology: Cell with vacuum soldered
Case: transfer molded plastic
Epoxy: UL94V-0 rate flame retardant
Lead: Plated lead , solderable per MIL-STD-202E
method 208C
Polarity: Color ring denotes cathode end
Mounting Position: any
Weight: 0.083 ounces, 2.32 grams
1.0(25.4)
MIN
1.0(25.4)
MIN
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
•
•
•
Ratings at 25℃ ambient temperature unless otherwise specified
Single Phase, half wave, 60HZ, resistive or inductive load
For capacitive load derate current by 20%
SYMBOLS
ARL2505
ARL251
ARL252
ARL254
ARL256
ARSL2505
ARSL251
ARSL252
ARSL254
ARSL256
UNIT
Maximum Repetitive Peak Reverse Voltage
VRRM
50
100
200
400
600
Volts
Maximum RMS Voltage
VRMS
35
70
140
280
420
Volts
Maximum DC Blocking Voltage
VDC
50
100
200
400
600
Volts
Maximum Average Forward Rectified Current,
IO
25.0
Amps
IFSM
400
Amps
Rating for fusing (t<8.3ms)
I2t
664
A2S
Maximum instantaneous Forward Voltage at 80A
VF
1.1
Volts
At Tc=110℃
Peak Forward Surge Current
3.3mS single half sine wave superimposed on
Rated load (JEDEC method)
Maximum DC Reverse Current at Rated TA=25℃
DC Blocking Voltage per element TA=100℃
Typical Thermal Resistance
Operating and Storage Temperature Range
5.0
IR
RθJC
1.0
℃/W
TJ,TSTG
(-65 to +175)
℃
Polarity and voltage demotion color band
Red
Notes:
1.
UA
250
Enough heatsink must be considered in application.
Web Site: www.hkmic.com
Yellow
Silver
Green
Green
BUTTON AUTOMOTIVE RECTIFIER
ARL2505 THRU ARL256
ARSL2505 THRU ARSL256
CURRENT
25.0 Amperes
F1G.2 MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
PEAK FORWARD SURGE
CURRENT,(A)
F1G.1 TYPICAL FORWARD CURRENT
DERATING GURVE
AVERAGE FORWARD CURRENT,
(A)
50 to 600 Volts
ARL2505 THRU ARL256
ARSL2505 THRU ARSL256
RATINGS AND CHARACTERISTIC CURVES
30
25
20
Single Phase
Half Wave 60Hz
10
VOLTAGE RANGE
Resistive or
Inductive Load
8.3ms Single Half Sine-Wave
500
(JEDEC Method) Tj=Tj max
400
300
200
100
1 Cycle
0.375″(9.5mm) Lead Length
0
1
0
0
25
50
75
110
100
125
150
175
2
4
6
8 10
20
40
60
100
NUMBER OF CYCLES AT 60 Hz
CASE TEMPERATURE, (℃)
F1G.3 TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
F1G.4 FORWARD ROWER DISSIPATION
AVERAGE POWER DISSIPATION
(W)
INSTANTANEOUS FORWARD CURRENT,
(A)
1000
100
10
T1=25℃
PULSE WIDTH=300μS
1%DUTY CYCLE
0.8
1.0
1.2
1.4
1.6
40
SQUARE WAVE
20
0
0
5
10
15
20
AVERAGE FORWARD CURRENT, (A)
1.0
0.1
0.6
60
1.8
2.0
INSTANTANEOUS FORWARD VOLTAGE,(V)
Web Site: www.hkmic.com