1W SMD DC-DC Converter P1ES-Series ● ● ● ● ● ● Single output Up to 1500 VDC isolation MTBF > 3.5 Mio. h at 25 °C -40...105 °C Operating temperature range Continuous short circuit protection Efficiency up to 81 % Model guide Type P1ES3R33R3S P1ES3R305S P1ES3R312S P1ES053R3S P1ES0505S P1ES0509S P1ES0512S P1ES0515S P1ES0524S P1ES1205S P1ES1209S P1ES1212S P1ES1215S P1ES1224S P1ES1505S P1ES1515S P1ES2405S P1ES2409S P1ES2412S P1ES2415S P1ES2424S Input voltage range Output voltage [VDC] [VDC] no-load typ. [mA] full-load typ. [mA] min. [mA] max. [mA] Output voltage drift @ load 10~100% [%] 2.97…3.63 2.97…3.63 2.97…3.63 4.5..5.5 4.5..5.5 4.5..5.5 4.5..5.5 4.5..5.5 4.5..5.5 10.8..13.2 10.8..13.2 10.8..13.2 10.8..13.2 10.8..13.2 13.5..16.5 13.5..16.5 21.6..26.4 21.6..26.4 21.6..26.4 21.6..26.4 21.6..26.4 3.3 5.0 12 3.3 5.0 9.0 12.0 15.0 24.0 5.0 9.0 12.0 15.0 24.0 5.0 15.0 5.0 9.0 12.0 15.0 24.0 30 30 30 20 20 20 20 20 20 15 15 15 15 15 10 10 7 7 7 7 7 390 390 390 250 250 250 250 250 250 104 104 103 103 103 83 82 52 52 51 51 51 30 20 9 20 20 12 9 7 4 20 12 9 7 4 20 7 20 11 8 7 4 300 200 84 300 200 111 84 67 42 200 111 84 67 42 200 67 200 110 83 67 42 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 Part designation structure PHI-CON & Series output power designation P1 1W E Input current Mounting technology S SMD Output current Input voltage Output voltage 3R3 05 12 15 24 3R3 05 09 12 15 24 3.3V 5V 12 V 15 V 24 V Fig. 1 Input reflected ripple current measure circuit 3.3V 5V 9V 12 V 15 V 24 V Reflected input ripple current (see Fig.1) typ. [mA] 20 20 20 15 15 15 15 15 15 5 5 5 5 5 5 5 5 5 5 5 5 Output configuration S Single Efficiency typ. Capacitive load max. [%] [µF] 77 78 78 78 80 80 80 80 80 80 80 81 81 81 80 81 80 80 81 81 81 220 220 220 220 220 220 220 220 220 220 220 220 220 220 220 220 220 220 220 220 220 Packing blank TR Tube Reel Fig. 2 EMI recommended external circuit oscilloscope current probe + Vin + Vin 4.7µH Measure point 220 µF ESR <1 Ω at 100 kHz - Vin L Load CX Load - Vin CY External components to meet IEC/EN55022, CLASS A see Fig. 2 Vin Version Model series CX CY 5V P1ES05xxDx 4.7 µF, 50 V not assembled 12 V P1ES12xxDx 4.7 µF, 50 V not assembled 15 V P1ES15xxDx 4.7 µF, 50 V 470 pF, 2 kV 24 V P1ES24xxDx 4.7 µF, 50 V 470 pF, 2 kV L 6.8 µH 6.8 µH 6.8 µH 6.8 µH Page 1 of 6 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 1W SMD DC-DC Converter P1ES-Series Specifications Input Voltage range Filter Input / output: Isolation voltage tested for 60 sec. @ leakage current < 1mA Isolation Resistance @ 500 VDC Capacitance Output Output voltage drift @ input voltage change Output voltage tolerance at 70 % load Output voltage drift @ 10 % to 100 % load change Temperature coefficient Short circuit protection Ripple & noise (BW 20 MHz) General Switching frequency Environmental EMI CE, with external filter circuit Fig. 2 EMS, ESD ± 10 % Capacitor 1.5 kVDC Operating temperature (ambient) Storage temperature Case temperature rise at full load Derating Humidity 109 Ω, min. 30 pF, typ. @ P1ES2424S 20 pF, typ. @ all others ± 1.2 % @ 1% Vin change ± 5 % max. See diagram below See diagram below 0.03 % / °C, max., at full load Continuous, automatic recovery 30 mV @ Vout 5, 9, 12 V Types 60 mV @ Vout 12 & 24 V Types ~ 100 kHz… 300 kHz Cooling Physical Package material Weight Reliability, MTBF (MIL-HDBK-217 @ 25 °C) Absolute maximum ratings Vin 5 V types Vin 12 V types Vin 15 V types Vin 24 V types Manual soldering lead temperature Soldering temperature Moisture sensitivity level (MSL) CISPR22 / EN55022 CLASS B IEC-, EN61000-4-2, contact ± 8 kV perf. criteria B -40 °C to +105 °C with derating -55 °C to +125 °C 25 °C, typ. See derating curve Up to 95 %, non-condensing Free-air convection Epoxy resin (UL94-V0) 1.52 g 3.5 Mio. hours -0.7 ~ 9 VDC, max. 1 s -0.7 ~ 18 VDC, max. 1 s -0.7 ~ 21 VDC, max. 1 s -0.7 ~ 30 VDC, max. 1 s 300 °C max. 10 s max., 1.5 mm distance from body 217 °C for 60 s max., 245 °C peak IPC/JEDEC J-STD-020D.1 Note: 1. Operation under minimum load will not damage the converter. However, they may not meet all specifications. 2. Maximum capacitive load is tested at nominal input voltage and full load. 3. Unless otherwise noted, all specifications are measured at Ta 25 °C, humidity <75 %, nominal input voltage and rated output load. 4. Specifications of this product are subject to changes without prior notice. 5. P1ES series is not usable for IGBT driver applications. Fig. 3 recommended external circuit for ripple & noise reduction + Vin + Vout Cin - Vin Table A External capacitor table for Figure 3 Vin version Cin Vout version 5V 4.7 µF 5V 12 V 2.2 µF 9V 15 V 2.2 µF 12 V 24 V 1 µF 15 V 24 V Recommended circuit If you want to further decrease the input/output ripple, a capacitor filtering network may be connected to the input and output ends of the DC/DC converter, see (Figure 3). Cout - Vin Cout 10 µF 4.7 µF 2.2 µF 1 µF 0.47 µF It should also be noted that the capacitance of filter capacitor must be proper. If the capacitance is too big, a start up problem might arise. To ensure safe and reliable operation, the capacitance of the output filter for each output channel may not exceed certain values (see table page 1). It’s not recommended to connect any external capacitor in the application field with less than 0.5 watt output. Page 2 of 6 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 1W SMD DC-DC Converter P1ES-Series Page 3 of 6 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 1W SMD DC-DC Converter P1ES-Series Dimensions Footprint Notes: All dimensions are in mm General tolerances ±0.25 mm Pin tolerances ±0.1 mm Lead 1 2 3 4 5 6 7 8 Lead connection - Vinput + Vinput No lead - Voutput + Voutput No lead No lead Not connected Page 4 of 6 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 1W SMD DC-DC Converter P1ES-Series Page 5 of 6 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 1W SMD DC-DC Converter P1ES-Series PHI-CON is a trademark of HY-LINE Holding GmbH. Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 10.14 f Page 6 of 6 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]