5W AC-DC Power-Supply PAC5C ● ● ● ● ● ● ● Enclosed plastic case 85 … 264 VAC or 120 … 370 VDC universal input range Continuously short circuit protected Over voltage protected Isolation class II MTBF > 300000 hours 3 years product warranty Model guide Output voltage Type PAC5C03S PAC5C05S PAC5C09S PAC5C12S PAC5C15S PAC5C24S [VDC] 3.3 5.0 9.0 12 15 24 Output voltagetolerance [%] typ. ±3 ±2 ±2 ±2 ±2 ±2 Output current Efficiency @ full load Capacitive load [mA] max. 1250 1000 550 420 330 230 [%] typ. 70 75 77 79 80 82 [µF] max. 32000 30000 3800 2500 1300 800 Specification Input Voltage range Line frequency range Full load input current Inrush current Recommended fuse Isolation Isolation voltage (input to output) Leakage current Output Voltage accuracy Line regulation Temperature coefficient Ripple & noise up to 20 MHz Output load stability @ load change 10 to 100 % Protection Short circuit Over current Over temperature Output over voltage protection (external TVS D1 see Fig.1) General Switching frequency Hold up time @ full load Reliability MTBF@25°C 85..264 VAC or 120..370 VDC Power derating see diagram 47…63 Hz 125 mA @ 115 VAC, typ. 80 mA @ 230 VAC, typ. 10 A typ. @ 115 VAC 20 A typ. @ 230 VAC 2 A / 250 V slow blow 3000 VAC for 1 min. 0.3 mA typ. @ Vin 230 VAC / 50 Hz ±2% ± 0.5 % ± 0.02 % / °C 100 mVp-p max. ±1% Continuous, auto recovery 110 %, min. of full load 150 °C, max. PAC5C03S: < 7.5 VDC PAC5C05S: < 7.5 VDC PAC5C09S: < 12 VDC PAC5C12S: < 20 VDC PAC5C15S: < 20 VDC PAC5C24S: < 30 VDC 65 kHz typ. 15 ms @ 115 VAC typ. 80 ms @ 230 VAC typ. >300000 h EMC compliance EMI: Conducted & Radiation (EMC application circuit is required, see figure 2) ESD: Electrostatic discharge RS: field susceptibility EFT: Fast transients on mainsline Surge: External circuit is required to converter at inrush and fast transient test, refer to typical application! CS: PFM: Voltage dips, short and interruptions immunity Safety approvals Safety Environmental Operating temperature (ambient) Case temperature Storage temperature Power derating above 55°C and below 0°C Humidity Cooling Physical Dimensions, PCB version Weight Case material Soldering temperature CE: EN55011 (CISPR22), class B RE: EN55011 (CISPR22), class B IEC-, EN61000-4-2, air ± 8 kV, contact ± 6 kV, pref. Criteria B IEC-, EN61000-4-3, 10 V / m pref. Criteria A IEC-, EN61000-4-4, ± 4 kV, pref. Criteria B IEC, EN61000-4-5, ±2 kV / ± 4 kV, pref. Criteria B IEC-, EN61000-4-6, 10 Vrms, perf. Criteria A IEC-, EN61000-4-8, 10 A / m, perf. Criteria A IEC-, EN61000-4-11, 0 %...70 %, perf. Criteria B EN60950, UL60950, EN60601-1 Class I -40 °C to 70 °C (with derating) 90°C, max. -40 °C to +105 °C 3.75 % per °C, see diagram 85 %, non-condensing Free-air convection 36 x 48.5 x 20.5 mm 50 g UL94V-0 rated 260°C, 10s, 1.5mm from case Page 1 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 5W AC-DC Power-Supply PAC5C Page 2 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 5W AC-DC Power-Supply PAC5C PAC5C L +Vout -Vout N PE This connection is not supported for the PAC5C series! Output ripple & noise measure circuit Conductor track Oscilloscope probe L AC AC line voltage C1 C2 Load 1 µF DC N 10 µF ceramic 25.4mm Typical application circuit Figure 1 F1 L PAC5C R1 L ϑ C1 C2 D1 +Vout +Vo R2 U N 25.4mm -Vout -Vo N PE PE Application circuit and example for ripple and noise reduction Figure 2 PAC5C L Rs F1 PIF001A L1 L V U N Cy Cy Cy Cx +V out Rd +V out Cy PE -V out C1 C2 D1 -V out Rs N PE C1 C2 F1 R1 Rs Rd V D1 Cy Cx L1 400 V~ 250 V~ Common mode Cer. Slow blow fuse NTC MOV TVS [nF] [µF] [µF] [µF] type [Ω] [MΩ] type type [mH] PAC5C03S 1 330 1A / 250V~ 5D-9 2 1 S14K350 SMBJ7.0A 1 0.1 10 … 30 PAC5C05S 1 330 1A / 250V~ 5D-9 2 1 S14K350 SMBJ7.0A 1 0.1 10 … 30 PAC5C09S 1 120 1A / 250V~ 5D-9 2 1 S14K350 SMBJ12A 1 0.1 10 … 30 PAC5C12S 1 120 1A / 250V~ 5D-9 2 1 S14K350 SMBJ20A 1 0.1 10 … 30 PAC5C15S 1 120 1A / 250V~ 5D-9 2 1 S14K350 SMBJ20A 1 0.1 10 … 30 PAC5C24S 1 68 1A / 250V~ 5D-9 2 1 S14K350 SMBJ30A 1 0.1 10 … 30 PIF 001A is an integrated PHI-CON filter module which contains all components in the framed field of figure 2. Model Page 3 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 5W AC-DC Power-Supply PAC5C Recommended PCB layout with EMC-Filter PIF001A Note: 1. Output filtering capacitor C2 is an electrolytic capacitor. It is recommended to use high frequency and low impedance electrolytic capacitor. For capacitance and current of capacitor please refer to manufacture’s datasheet. Voltage derating of capacitor should be 80% or above. C1 is a ceramic capacitor, it is used to filter high frequency noise. TVS D1 is a recommended component to protect post-circuits (if converter fails). 2. The varistor R2 protect the device under surge. 3. Recommended fuse parameter for F1 are 1 A / 250 V slow blow. A external input NTC limited the inrush current. Recommended model is NTC 5D-9. (see figure 1 and table) 4. If common requirement to EMC performance (EN55011 Class A), refer to figure 1. If higher requirement to EMC performance (EN55011 Class B), refer to figure 2. C6: X capacitor, recommended values 0.1 μF / 275 V; C4, C5: Y capacitor, recommended values 2200 pF / 400 V; L1: common mode choke, recommended inductance is about 10 mH – 30 mH. Dimensions Unit: mm Pin diameter tolerance: ± 0.1 mm Pin length: >6 mm General tolerances: ± 0.5 mm Pin 1 2 3 4 5 6 7 8 Pin configuration Single PE N L - V out Not connected Not connected Not connected + V out PHI-CON is a trademark of HY-LINE Power Components. Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions for use carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 03.14 f Page 4 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]