Download

5W AC-DC Power-Supply PAC5C
●
●
●
●
●
●
●
Enclosed plastic case
85 … 264 VAC or 120 … 370 VDC universal input range
Continuously short circuit protected
Over voltage protected
Isolation class II
MTBF > 300000 hours
3 years product warranty
Model guide
Output voltage
Type
PAC5C03S
PAC5C05S
PAC5C09S
PAC5C12S
PAC5C15S
PAC5C24S
[VDC]
3.3
5.0
9.0
12
15
24
Output
voltagetolerance
[%] typ.
±3
±2
±2
±2
±2
±2
Output current
Efficiency @ full load
Capacitive load
[mA] max.
1250
1000
550
420
330
230
[%] typ.
70
75
77
79
80
82
[µF] max.
32000
30000
3800
2500
1300
800
Specification
Input
Voltage range
Line frequency range
Full load input current
Inrush current
Recommended fuse
Isolation
Isolation voltage (input to output)
Leakage current
Output
Voltage accuracy
Line regulation
Temperature coefficient
Ripple & noise up to 20 MHz
Output load stability @ load
change 10 to 100 %
Protection
Short circuit
Over current
Over temperature
Output over voltage protection
(external TVS D1 see Fig.1)
General
Switching frequency
Hold up time @ full load
Reliability MTBF@25°C
85..264 VAC or 120..370 VDC
Power derating see diagram
47…63 Hz
125 mA @ 115 VAC, typ.
80 mA @ 230 VAC, typ.
10 A typ. @ 115 VAC
20 A typ. @ 230 VAC
2 A / 250 V slow blow
3000 VAC for 1 min.
0.3 mA typ. @ Vin 230 VAC / 50 Hz
±2%
± 0.5 %
± 0.02 % / °C
100 mVp-p max.
±1%
Continuous, auto recovery
110 %, min. of full load
150 °C, max.
PAC5C03S: < 7.5 VDC
PAC5C05S: < 7.5 VDC
PAC5C09S: < 12 VDC
PAC5C12S: < 20 VDC
PAC5C15S: < 20 VDC
PAC5C24S: < 30 VDC
65 kHz typ.
15 ms @ 115 VAC typ.
80 ms @ 230 VAC typ.
>300000 h
EMC compliance
EMI: Conducted & Radiation
(EMC application circuit is
required, see figure 2)
ESD: Electrostatic discharge
RS: field susceptibility
EFT: Fast transients on mainsline
Surge: External circuit is required
to converter at inrush and fast
transient test, refer to typical
application!
CS:
PFM:
Voltage dips, short and
interruptions immunity
Safety approvals
Safety
Environmental
Operating temperature (ambient)
Case temperature
Storage temperature
Power derating above 55°C and
below 0°C
Humidity
Cooling
Physical
Dimensions, PCB version
Weight
Case material
Soldering temperature
CE: EN55011 (CISPR22), class B
RE: EN55011 (CISPR22), class B
IEC-, EN61000-4-2, air ± 8 kV, contact ±
6 kV, pref. Criteria B
IEC-, EN61000-4-3, 10 V / m pref.
Criteria A
IEC-, EN61000-4-4, ± 4 kV, pref. Criteria
B
IEC, EN61000-4-5, ±2 kV / ± 4 kV, pref.
Criteria B
IEC-, EN61000-4-6, 10 Vrms,
perf. Criteria A
IEC-, EN61000-4-8, 10 A / m,
perf. Criteria A
IEC-, EN61000-4-11, 0 %...70 %,
perf. Criteria B
EN60950, UL60950, EN60601-1
Class I
-40 °C to 70 °C (with derating)
90°C, max.
-40 °C to +105 °C
3.75 % per °C, see diagram
85 %, non-condensing
Free-air convection
36 x 48.5 x 20.5 mm
50 g
UL94V-0 rated
260°C, 10s, 1.5mm from case
Page 1 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
5W AC-DC Power-Supply PAC5C
Page 2 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
5W AC-DC Power-Supply PAC5C
PAC5C
L
+Vout
-Vout
N
PE
This connection is not supported for the PAC5C series!
Output ripple & noise measure circuit
Conductor track
Oscilloscope probe
L
AC
AC
line
voltage
C1
C2
Load
1 µF
DC
N
10 µF
ceramic
25.4mm
Typical application circuit
Figure 1
F1
L
PAC5C
R1
L
ϑ
C1
C2
D1 +Vout
+Vo
R2
U
N
25.4mm
-Vout
-Vo
N
PE
PE
Application circuit and example for ripple and noise reduction
Figure 2
PAC5C
L
Rs
F1
PIF001A
L1
L
V
U
N
Cy
Cy
Cy
Cx
+V out
Rd
+V out
Cy
PE
-V out
C1
C2
D1
-V out
Rs
N
PE
C1
C2
F1
R1
Rs
Rd
V
D1
Cy
Cx
L1
400 V~ 250 V~ Common mode
Cer.
Slow blow fuse NTC
MOV
TVS
[nF]
[µF]
[µF]
[µF]
type
[Ω]
[MΩ]
type
type
[mH]
PAC5C03S
1
330
1A / 250V~
5D-9
2
1
S14K350
SMBJ7.0A
1
0.1
10 … 30
PAC5C05S
1
330
1A / 250V~
5D-9
2
1
S14K350
SMBJ7.0A
1
0.1
10 … 30
PAC5C09S
1
120
1A / 250V~
5D-9
2
1
S14K350
SMBJ12A
1
0.1
10 … 30
PAC5C12S
1
120
1A / 250V~
5D-9
2
1
S14K350
SMBJ20A
1
0.1
10 … 30
PAC5C15S
1
120
1A / 250V~
5D-9
2
1
S14K350
SMBJ20A
1
0.1
10 … 30
PAC5C24S
1
68
1A / 250V~
5D-9
2
1
S14K350
SMBJ30A
1
0.1
10 … 30
PIF 001A is an integrated PHI-CON filter module which contains all components in the framed field of figure 2.
Model
Page 3 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
5W AC-DC Power-Supply PAC5C
Recommended PCB layout with EMC-Filter PIF001A
Note:
1. Output filtering capacitor C2 is an electrolytic capacitor. It is recommended to use high frequency and low impedance electrolytic
capacitor. For capacitance and current of capacitor please refer to manufacture’s datasheet. Voltage derating of capacitor should be
80% or above. C1 is a ceramic capacitor, it is used to filter high frequency noise. TVS D1 is a recommended component to protect
post-circuits (if converter fails).
2. The varistor R2 protect the device under surge.
3. Recommended fuse parameter for F1 are 1 A / 250 V slow blow. A external input NTC limited the inrush current.
Recommended model is NTC 5D-9. (see figure 1 and table)
4. If common requirement to EMC performance (EN55011 Class A), refer to figure 1.
If higher requirement to EMC performance (EN55011 Class B), refer to figure 2.
C6: X capacitor, recommended values 0.1 μF / 275 V;
C4, C5: Y capacitor, recommended values 2200 pF / 400 V;
L1: common mode choke, recommended inductance is about 10 mH – 30 mH.
Dimensions
Unit: mm
Pin diameter tolerance: ± 0.1 mm
Pin length: >6 mm
General tolerances: ± 0.5 mm
Pin
1
2
3
4
5
6
7
8
Pin configuration
Single
PE
N
L
- V out
Not connected
Not connected
Not connected
+ V out
PHI-CON is a trademark of HY-LINE Power Components.
Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions for
use carefully before using!
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the
express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose
failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to
result in significant injury to the user. Rev: 03.14 f
Page 4 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]