AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:58 Seite 1 AC axial fans - HyBlade® The engineer’s choice version 07/2010 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:58 Seite 2 New AC axial fans - HyBlade® A new, first-of-its-kind hybrid blade design makes these ebm-papst axial fans even quieter, more powerful and more durable than ever. In designing the HyBlade® fan blades, we have developed a support structure of high-strength, corrosion-resistant aluminium alloy with a jacket of a special, fibre-reinforced plastics. Compared to conventional blades, the optimal aerodynamic shape results in an enormous noise reduction while significantly increasing efficiency. And thus it offers even more advantages for use in refrigeration, heating and ventilation technology. Revolutionary design In the field of refrigeration and ventilation, axial fans are widely used, e.g. to cool heat exchangers by making air pass through them. For ages, the ebm-papst external-rotor motor has proved to be the best choice as it has a compact design, with the axial blades directly mounted onto the rotor. However, fans are not only expected to have compact dimensions. Fans are also expected to offer maximum air performance at an absolute minimum of noise. Until now, the fan blades have been conventionally manufactured of steel or aluminium sheet. To keep up with the increasing demands on efficiency and noise behaviour, ebm-papst set its sights on the development of new blade geometries. In their research, ebm-papst engineers found themselves up against limits caused by the restrictive design potential of the monolithic sheet-metal blade with uniform plate thickness. To break these barriers and to achieve lower noise and better efficiency, they realised that entirely new principles of design, materials and component structures were necessary. And so, ebm-papst uses their revolutionary hybrid blade design to preserve seemingly incompatible properties by means of hybrid components and structures. Strong connection In designing the HyBlade® axial fan blades, ebm-papst was the first to use a support structure of highstrength, corrosion-resistant aluminium alloy with a jacket made of a special, fibre-reinforced plastics. Using these two materials makes for an ideal combination of their individual characteristics. The aluminium inlet receives the mechanical forces and ensures a durable connection to the rotor during operation, while the plastic encapsulating the support structure gives the blade its optimised aerodynamic shape. At the same time, the plastic jacket has a positive effect on the total weight of the fan. Two aspects add to the considerable noise reduction as compared to conventional blades: The aerodynamically optimised and profiled contour, and the simple addition of "winglets" to the ends of the blades. In meeting the ebm-papst quality standards, extensive tests and calculations were performed to guarantee the reliability of this new technology. With HyBlade®, ebm-papst has set new standards in fan technology by minimising noise and increasing maximum efficiency. 2 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:58 Seite 3 Table of content New AC axial fans - HyBlade® 2 GreenTech: The Green Company 4 Size 500 6 Size 560 12 Size 630 16 Size 710 22 Size 800 26 Size 910 30 Electrical connections 34 Technical parameters & scope 36 ebm-papst representatives & subsidiaries 40 3 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:58 Seite 4 Sustainability is at the Centre of Our Thoughts and Actions. Out of Conviction! Eco-friendliness and sustainability have always been at the core of our thoughts and actions. For decades, we have worked according to the simple but strict creed of our co-founder Gerhard Sturm: “Each new product we develop has to be better than the last one in terms of economy and ecology.” GreenTech is the ultimate expression of our corporate philosophy. AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:58 Seite 5 GreenTech is pro-active development. GreenTech is acknowledged and certified. Even in the design phase, the materials and processes we use are optimi- Every step in our chain of production meets the stringent standards of sed for the greatest possible eco-friendliness, energy balance and – environmental specialists and the public. The 2008 Environmental Prize wherever possible – recyclability. We continually improve the material of Baden-Wuerttemberg, the Green Award 2009, the Energy Efficiency and performance of our products, as well as the flow and noise charac- Award 2009 of the dena – to give just a few examples – testify to this. teristics. At the same time, we significantly reduce energy consumption. The environmental advantage gained in the performance of the products Close cooperation with universities and scientific institutes and the pro- developed from our GreenTech philosophy can also be measured in the fessorship we endow in the area of power engineering and regenerative fulfilment of the most stringent energy and environmental standards. energies allows us to profit from the latest research findings in these In many instances, our products are already well below the thresholds fields – and at the same time ensure highly qualified young academics. energy legislation will impose a few years from now – several times over. GreenTech is ecofriendly production. Our customers profit from this every day. GreenTech also stands for maximum energy efficiency in our production The heart of GreenTech is ebm-papst EC technology. The EC technology processes. There, the intelligent use of industrial waste heat and ground- at the core of our most efficient motors and fans allows efficiency of up water cooling, photovoltaics and, of course, our own cooling and venti - to 90%, saves energy at a very high level, significantly extends service lation technology are of the utmost importance. Our most modern plant, life and makes our products maintenance-free. These values pay off not for instance, consumes 91% less energy than currently specified and only for the environment, but every cent also pays off for the user! All required. In this way, our products contribute to protecting the environ- ebm-papst products – even those for which EC technology does not (yet) ment, from their origin to their recyclable packaging. make sense from an application viewpoint – feature the greatest possible connection of economy and ecology. 5 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:58 Seite 6 AC axial fans - HyBlade® Ø 500 *6D 500 M6D 110-EF *8D 500 M8D 110-EF B C D E F G 0° A ∆ Y ∆ Y ∆ Y ∆ Y 50 50 50 50 50 50 50 50 1340 1060 1390 1180 930 800 680 560 0,71 0,48 0,72 0,55 0,27 0,19 0,15 0,09 1,40 0,80 1,41 0,95 0,69 0,40 0,40 0,18 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 A 0° kW H Electr. connection 0° rpm Perm. amb. temp. M4D 110-GF Hz Max. operative range *4D 500 VAC Capacitor 0° Max. current draw (1) M4D 110-EF Max. power input (1) *4D 500 Speed/rpm (1) Motor Frequency Type Nominal voltage Nominal data Curve Blade angle – Material: Guard grille: Steel, phosphated and coated in black plastic Wall ring: Sheet steel, pre-galvanised and coated in black plastic Blades: Pressed-on round sheet steel plate, extrusion-coated in PP plastics Rotor: Coated in black – Number of blades: 5 – Direction of rotation: counter-clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharge holes: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings – Motor protection: Design with thermal overload protector µF/VDB Pa °C p. 34 140 87 140 100 75 55 40 28 -40..+60 -40..+60 -40..+65 -40..+65 -40..+65 -40..+65 -40..+65 -40..+65 — — — — — — — — Air performance measured 2 [in H O] [Pa] Curves 3 0,5 0,4 2 2 0,60 1,30 72 0,66 1,34 71 A 3 1340 0,71 1,40 71 B 1 1135 0,43 0,71 68 B 2 1095 0,46 0,76 66 Suction-side noise levels: B 3 1060 0,48 0,80 65 LwA as per ISO 13347, C 1 1410 0,60 1,28 72 C 2 1400 0,66 1,34 71 C 3 1390 0,72 1,41 71 D 1 1245 0,48 0,78 70 D 2 1215 0,52 0,84 68 D 3 1180 0,55 0,95 68 LpA measured at 1 m distance to fan axis 3 B 80 The acoustic values given are 0,3 2 only valid under the measurment conditions listed and 2 may vary depending on the 60 0,2 installation situation. 1 1 40 With any deviation to the stan- 1 dard setup, the specific values 1 0,1 have to be checked and reviewed once installed or fitted! 20 For detailed information see page 36 ff. 1000 2000 2000 3000 3000 4000 5000 4000 6000 7000 5000 8000 9000 [CFM] [m3/h] LwA [dB(A)] 1360 accidental contact D I [A] 1375 120 3 P1 [kW] 2 and without protection against A n [rpm] 1 in ebm-papst full nozzle C 6 F1b)/F2b) A Installation category A, 3 140 1000 F1b)/F2b) A as per: ISO 5801, 0 F1b)/F2b) (1) Nominal data in operating point 3 with maximum load subject to alterations 100 F1b)/F2b) AC_HyBlade_05_2010_EN:Axial_D 17:58 Seite 7 Cable exit: Via terminal box Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Direction of air flow – – – – 06.07.2010 ❮ "V" ❮ "V" Without attachments ❮ "V" With full square nozzle With guard grille for short nozzle "V" A4D 500-AJ03 -01 W4D 500-GJ03 -01 S4D 500-AJ03 -01 "V" A4D 500-AM03 -01 W4D 500-GM03 -01 S4D 500-AM03 -01 "V" A6D 500-AJ03 -01 W6D 500-GJ03 -01 S6D 500-AJ03 -01 "V" A8D 500-AJ03 -01 W8D 500-GJ03 -01 S8D 500-AJ03 -01 Direction of air flow "A" on request Air performance measured 2 [in H O] [Pa] Curves P1 [kW] I [A] LwA [dB(A)] E 1 945 0,23 0,65 64 E 2 935 0,25 0,66 62 E 3 930 0,27 0,69 63 F 1 850 0,16 0,29 62 F 2 830 0,17 0,30 59 Suction-side noise levels: F 3 800 0,19 0,40 59 LwA as per ISO 13347, G 1 700 0,13 0,37 58 G 2 695 0,13 0,38 55 G 3 680 0,15 0,40 54 H 1 610 0,08 0,16 55 H 2 590 0,08 0,16 51 H 3 560 0,09 0,18 50 as per: ISO 5801, 3 n [rpm] Installation category A, 70 E in ebm-papst full nozzle 0,25 and without protection against accidental contact 60 3 50 0,2 F 2 LpA measured at 1 m distance to fan axis 3 G 0,15 40 The acoustic values given are 2 only valid under the measurment conditions listed and 30 installation situation. 0,1 3 may vary depending on the 2 H 1 2 20 With any deviation to the stan- 1 dard setup, the specific values 0,05 1 have to be checked and re- 1 10 viewed once installed or fitted! For detailed information see page 36 ff. 0 500 1000 1000 2000 1500 2000 3000 2500 4000 3000 5000 3500 [CFM] 6000 [m3/h] 7 Drawings S. 10 Electr. connections S. 34 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:58 Seite 8 AC axial fans - HyBlade® Ø 500 Frequency Speed/rpm (1) Max. power input (1) Max. current draw (1) Capacitor Max. operative range Perm. amb. temp. Electr. connection VAC Hz rpm kW A µF/VDB Pa °C p. 34 1~ 230 50 1225 0,60 2,62 10,0 /400 100 -40..+55 A2b) B 1~ 230 50 1300 0,68 3,00 12,0 /450 150 -40..+65 A2b) 0° C 1~ 230 50 915 0,27 1,18 8,0 /400 70 -40..+65 A2b) 0° D 1~ 230 50 665 0,13 0,59 3,0 /400 35 -40..+65 A2b) Nominal data Curve Blade angle Nominal voltage – Material: Guard grille: Steel, phosphated and coated in black plastic Wall ring: Sheet steel, pre-galvanised and coated in black plastic Blades: Pressed-on round sheet steel plate, extrusion-coated in PP plastics Rotor: Coated in black – Number of blades: 5 – Direction of rotation: counter-clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharge holes: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings – Motor protection: Design with thermal overload protector Type Motor *4E 500 M4E 110-EF 0° A *4E 500 M4E 110-GF 0° *6E 500 M6E 110-EF *8E 500 M8E 110-EF (1) Nominal data in operating point 3 with maximum load subject to alterations Air performance measured 2 [in H O] [Pa] Curves as per: ISO 5801, 3 in ebm-papst full nozzle and without protection against 0,5 B accidental contact 120 Suction-side noise levels: LwA as per ISO 13347, 3 0,4 100 2 LpA measured at 1 m distance A to fan axis 80 0,3 The acoustic values given are only valid under the measurment conditions listed and 2 may vary depending on the 60 0,2 installation situation. 1 With any deviation to the stan- 40 dard setup, the specific values 1 0,1 have to be checked and reviewed once installed or fitted! 20 For detailed information see page 36 ff. 0 1000 1000 8 2000 2000 3000 3000 4000 5000 4000 6000 7000 [CFM] 8000 [m3/h] P1 [kW] I [A] LwA [dB(A)] A 1 1295 0,53 2,30 71 A 2 1270 0,56 2,44 69 A 3 1225 0,60 2,62 68 B 1 1355 0,57 2,50 72 B 2 1330 0,62 2,73 70 B 3 1300 0,68 3,00 72 Installation category A, 140 n [rpm] AC_HyBlade_05_2010_EN:Axial_D 17:58 Seite 9 Cable exit: Via terminal box Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Direction of air flow – – – – 06.07.2010 ❮ "V" ❮ "V" Without attachments ❮ "V" With full square nozzle With guard grille for short nozzle "V" A4E 500-AJ01 -01 W4E 500-GJ01 -01 S4E 500-AJ01 -01 "V" A4E 500-AM03 -01 W4E 500-GM03 -01 S4E 500-AM03 -01 "V" A6E 500-AJ03 -01 W6E 500-GJ03 -01 S6E 500-AJ03 -01 "V" A8E 500-AJ03 -01 W8E 500-GJ03 -01 S8E 500-AJ03 -01 Direction of air flow "A" on request Air performance measured 2 [in H O] [Pa] Curves as per: ISO 5801, P1 [kW] I [A] LwA [dB(A)] C 1 935 0,24 1,03 64 C 2 925 0,25 1,10 62 C 3 915 0,27 1,16 63 D 1 690 0,11 0,54 59 D 2 680 0,12 0,56 56 D 3 665 0,13 0,59 54 Installation category A, 3 70 n [rpm] in ebm-papst full nozzle and without protection against 0,25 C accidental contact 60 Suction-side noise levels: 50 0,2 LwA as per ISO 13347, 2 LpA measured at 1 m distance to fan axis The acoustic values given are 0,15 40 only valid under the measur- 3 ment conditions listed and D may vary depending on the 30 0,1 installation situation. 1 With any deviation to the stan- 2 20 dard setup, the specific values 0,05 have to be checked and re- 10 viewed once installed or fitted! 1 For detailed information see page 36 ff. 0 500 1000 1000 2000 1500 2000 3000 2500 4000 3000 5000 3500 [CFM] 6000 [m3/h] 9 Drawings S. 10 Electr. connections S. 34 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:58 Seite 10 AC axial fans - HyBlade® Ø 500 with motor M**110, drawings for direction of air flow "V" Mass [kg] Type Without attachments A4D A4D A6D A8D A4E A4E A6E A8E 99x99 Ø497±2 Ø115±0,3 112±3 500-AJ03 -01 500-AM03 -01 500-AJ03 -01 500-AJ03 -01 500-AJ01 -01 500-AM03 -01 500-AJ03 -01 500-AJ03 -01 g 8,5 189,5 10,5 209,5 8,5 189,5 8,5 189,5 8,5 189,5 10,5 209,5 8,5 189,5 8,5 189,5 Internal diameter of the wall ring at least 503 mm 65,5 g±2 4xM6 Depth of screw max. 12 mm ❮ "V" Cable gland With full square nozzle f Mass [kg] f W4D 500-GJ03 -01 W4D 500-GM03 -01 W6D 500-GJ03 -01 W8D 500-GJ03 -01 W4E 500-GJ01 -01 W4E 500-GM03 -01 W6E 500-GJ03 -01 W8E 500-GJ03 -01 16,0 13,5 18,0 33,5 16,0 13,5 16,0 13,5 16,0 13,5 18,0 33,5 16,0 13,5 16,0 13,5 Type Mass [kg] v 11,8 64,0 13,8 84,0 11,8 64,0 11,8 64,0 11,8 64,0 13,8 84,0 11,8 64,0 11,8 64,0 Ø11 Ø535 176±5 Type 16 615±1 656-3 120 ❮ "V" With guard grille for short nozzle 126 7 500-AJ03 -01 500-AM03 -01 500-AJ03 -01 500-AJ03 -01 500-AJ01 -01 500-AM03 -01 500-AJ03 -01 500-AJ03 -01 Ø565 8,5 S4D S4D S6D S8D S4E S4E S6E S8E Internal diameter of the wall ring at least 503 mm 52±4 v±3 ❮ "V" 10 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:58 Seite 11 11 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:58 Seite 12 AC axial fans - HyBlade® Ø 560 *4E 560 M4E 110-IA *6E 560 M6E 110-EF kW A ∆ Y ∆ Y 50 50 50 50 1220 870 870 660 1,16 0,65 0,45 0,28 1,95 1,10 0,88 0,48 Electr. connection 0° rpm Perm. amb. temp. M6D 110-EF Hz Max. operative range *6D 560 VAC Capacitor 0° Max. current draw (1) M4D 110-GF Max. power input (1) *4D 560 Speed/rpm (1) Motor Frequency Type Nominal voltage Nominal data Curve Blade angle – Material: Guard grille: Steel, phosphated and coated in black plastic Wall ring: Sheet steel, pre-galvanised and coated in black plastic Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics Rotor: Encased in aluminium – Number of blades: 5 – Direction of rotation: counter-clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharge holes: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings – Motor protection: Design with thermal overload protector µF/VDB Pa °C p. 34 140 72 75 43 -40..+50 -40..+50 -40..+65 -40..+65 D 3~ 400 3~ 400 3~ 400 3~ 400 -5° E 1~ 230 50 1275 1,09 4,76 20,0 /450 160 -40..+55 A2b) -5° F 1~ 230 50 895 0,41 1,80 10,0 /400 85 -40..+65 A2b) A B C — — — — Air performance measured 1270 1,03 1,78 73 1250 1,09 1,87 72 A 3 1220 1,16 1,95 77 B 1 930 0,62 1,03 65 B 2 900 0,64 1,06 65 Suction-side noise levels: B 3 870 0,65 1,10 67 LwA as per ISO 13347, C 1 895 0,39 0,81 65 C 2 880 0,42 0,83 65 C 3 870 0,45 0,88 69 D 1 700 0,26 0,44 58 D 2 680 0,27 0,46 59 D 3 660 0,28 0,48 61 0,6 and without protection against 0,5 accidental contact A 0,4 LpA measured at 1 m distance 2 to fan axis The acoustic values given are 0,3 80 3 only valid under the measur3 B ment conditions listed and may vary depending on the 60 installation situation. 0,2 C 2 2 1 With any deviation to the stan- 3 40 dard setup, the specific values 2 0,1 D 1 have to be checked and re- 1 viewed once installed or fitted! 20 1 For detailed information see page 36 ff. 0 1000 2000 12 2000 4000 3000 4000 6000 5000 8000 6000 10000 7000 [CFM] 12000 [m3/h] LwA [dB(A)] 2 in ebm-papst full nozzle 120 I [A] 1 Installation category A, 3 P1 [kW] A as per: ISO 5801, 140 n [rpm] A 2 [in H O] [Pa] Curves 100 F1b)/F2b) (1) Nominal data in operating point 3 with maximum load subject to alterations 160 F1b)/F2b) AC_HyBlade_05_2010_EN:Axial_D 17:58 Seite 13 Cable exit: Via terminal box Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Direction of air flow – – – – 06.07.2010 ❮ "V" ❮ "V" Without attachments ❮ "V" With full square nozzle With guard grille for short nozzle "V" A4D 560-AM03 -01 W4D 560-GM03 -01 S4D 560-AM03 -01 "V" A6D 560-AJ03 -01 W6D 560-GJ03 -01 S6D 560-AJ03 -01 "V" A4E 560-AQ01 -01 W4E 560-GQ01 -01 S4E 560-AQ01 -01 "V" A6E 560-AK01 -01 W6E 560-GK01 -01 S6E 560-AK01 -01 Direction of air flow "A" on request 180 [in H2O] Air performance measured as per: ISO 5801, n [rpm] P1 [kW] I [A] LwA [dB(A)] E 1 1340 0,95 4,15 75 E 2 1315 1,02 4,44 73 E 3 1275 1,09 4,76 76 F 1 920 0,36 1,60 65 F 2 910 0,39 1,72 65 F 3 895 0,41 1,80 68 Installation category A, 0,70 [Pa] Curves in ebm-papst full nozzle and without protection against 160 3 0,60 accidental contact E 140 Suction-side noise levels: 100 LpA measured at 1 m distance to fan axis 0,40 120 0,50 LwA as per ISO 13347, The acoustic values given are 2 only valid under the measur3 0,30 80 ment conditions listed and F may vary depending on the installation situation. 60 0,20 2 With any deviation to the stan- 1 dard setup, the specific values 40 have to be checked and re0,10 20 1 viewed once installed or fitted! For detailed information see page 36 ff. 0 1000 2000 2000 4000 3000 4000 6000 5000 8000 6000 [CFM] 10000 [m3/h] 13 Drawings S. 14 Electr. connections S. 34 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:58 Seite 14 AC axial fans - HyBlade® Ø 560 with motor M**110, drawings for direction of air flow "V" Mass [kg] Type Without attachments A4D A6D A4E A6E c d 8,5 124,0 134,0 189,5 12,5 113,0 115,0 224,5 8,5 113,0 115,0 189,5 Ø552±2 99x99 Internal diameter of the wall ring at least 559 mm 65,5 g±2 4xM6 Depth of screw max. 12 mm ❮ "V" Cable gland With full square nozzle f Type Mass [kg] f W4D 560-GM03 -01 W6D 560-GJ03 -01 W4E 560-GQ01 -01 W6E 560-GK01 -01 24,0 17,5 Type Mass [kg] 22,0 --- 26,0 32,5 22,0 --- Ø11 Ø625 192±5 16 125 675±1 725-3 ❮ "V" With guard grille for short nozzle 125,5 8,5 Ø700 7 u±4 v±3 ❮ "V" 14 S4D S6D S4E S6E 560-AM03 -01 560-AJ03 -01 560-AQ01 -01 560-AK01 -01 g 10,5 124,0 134,0 209,5 Ø115±0,3 d±2 c±3 560-AM03 -01 560-AJ03 -01 560-AQ01 -01 560-AK01 -01 u v 15,0 88,0 108,0 13,0 88,0 17,0 77,0 123,0 13,0 77,0 Internal diameter of the wall ring at least 559 mm 88,0 88,0 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:58 Seite 15 15 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:58 Seite 16 AC axial fans - HyBlade® Ø 630 *4D 630 M4D 138-HF A ∆ Y ∆ Y ∆ Y 50 50 50 50 50 50 1330 1070 1320 1050 1310 1000 1,25 0,84 2,63 1,75 1,97 1,29 2,48 1,42 4,78 2,95 3,40 2,10 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 A B C D E -5° kW F Electr. connection 0° rpm Perm. amb. temp. M4D 138-LA Hz Max. operative range *4D 630 VAC Capacitor -10° Max. current draw (1) M4D 110-IA Max. power input (1) *4D 630 Speed/rpm (1) Motor Frequency Type Nominal voltage Nominal data Curve Blade angle – Material: Guard grille: Steel, phosphated and coated in black plastic Wall ring: Sheet steel, pre-galvanised and coated in black plastic Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics Rotor: Encased in aluminium – Number of blades: 5 – Direction of rotation: A B counter-clockwise, C D E F clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharge holes: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings – Motor protection: Design with thermal overload protector µF/VDB Pa °C p. 34 150 100 220 140 200 115 -40..+55 -40..+55 -40..+60 -40..+60 -40..+60 -40..+60 — — — — — — Air performance measured 2 [in H O] [Pa] Curves as per: ISO 5801, 0,6 in ebm-papst full nozzle and without protection against 0,5 accidental contact A 120 Suction-side noise levels: LwA as per ISO 13347, LpA measured at 1 m distance 0,4 2 to fan axis 3 B The acoustic values given are 80 0,3 only valid under the measurment conditions listed and 2 may vary depending on the 1 60 0,2 installation situation. With any deviation to the stan- 1 40 dard setup, the specific values 0,1 have to be checked and reviewed once installed or fitted! 20 For detailed information see page 36 ff. 0 1000 2000 16 F1b)/F2b) 2000 4000 3000 4000 6000 5000 8000 6000 10000 7000 [CFM] 12000 [m3/h] n [rpm] P1 [kW] I [A] LwA [dB(A)] A 1 1370 1,03 2,21 77 A 2 1355 1,14 2,32 75 A 3 1330 1,25 2,48 75 B 1 1140 0,74 1,23 72 B 2 1105 0,78 1,31 71 B 3 1070 0,84 1,42 70 Installation category A, 3 140 100 F1b)/F2b) (1) Nominal data in operating point 3 with maximum load subject to alterations 160 F1b)/F2b) AC_HyBlade_05_2010_EN:Axial_D 17:58 Seite 17 Cable exit: Via terminal box Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Direction of air flow – – – – 06.07.2010 ❮ "V" ❮ "V" Without attachments ❮ "V" With full square nozzle With guard grille for short nozzle "V" A4D 630-AR01 -01 W4D 630-GR01 -01 S4D 630-AR01 -01 "V" A4D 630-AD01 -01 W4D 630-GD01 -01 S4D 630-AD01 -01 "V" A4D 630-AH01 -01 W4D 630-GH01 -01 S4D 630-AH01 -01 Direction of air flow "A" on request Air performance measured 220 0,8 3 1360 2,30 4,29 78 2 1345 2,47 4,56 77 C 3 1320 2,63 4,78 80 D 1 1115 1,62 2,71 72 D 2 1080 1,68 2,83 72 Suction-side noise levels: D 3 1050 1,75 2,95 74 LwA as per ISO 13347, E 1 1345 1,68 2,94 75 E 2 1325 1,83 3,18 75 E 3 1310 1,97 3,40 78 F 1 1075 1,18 1,97 70 F 2 1035 1,24 2,08 68 F 3 1000 1,29 2,10 70 and without protection against E accidental contact 180 160 0,6 2 3 120 LpA measured at 1 m distance 2 D to fan axis The acoustic values given are 3 F only valid under the measur- 0,4 100 LwA [dB(A)] Installation category A, C 140 I [A] 1 in ebm-papst full nozzle 200 P1 [kW] C as per: ISO 5801, 3 n [rpm] C 2 [in H O] [Pa] Curves ment conditions listed and 2 may vary depending on the 2 80 installation situation. 1 1 With any deviation to the stan0,2 60 1 dard setup, the specific values 1 have to be checked and re- 40 viewed once installed or fitted! 20 For detailed information see page 36 ff. 0 2500 4000 5000 8000 7500 12000 10000 16000 [CFM] [m3/h] 17 Drawings S. 20 ff. Electr. connections S. 34 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:58 Seite 18 AC axial fans - HyBlade® Ø 630 *6E 630 M6E 110-GF *8E 630 M8E 110-GF kW A ∆ Y ∆ Y 50 50 50 50 890 690 660 520 0,60 0,40 0,33 0,19 1,20 0,68 0,83 0,39 Electr. connection -5° rpm Perm. amb. temp. M8D 110-GF Hz Max. operative range *8D 630 VAC Capacitor -5° Max. current draw (1) M6D 110-GF Max. power input (1) *6D 630 Speed/rpm (1) Motor Frequency Type Nominal voltage Nominal data Curve Blade angle – Material: Guard grille: Steel, phosphated and coated in black plastic Wall ring: Sheet steel, pre-galvanised and coated in black plastic Blades: Pressed-on round sheet steel plate, extrusion-coated in PP plastics Rotor: Coated in black – Number of blades: 5 – Direction of rotation: counter-clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharge holes: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings – Motor protection: Design with thermal overload protector µF/VDB Pa °C p. 34 105 56 60 36 -40..+65 -40..+65 -40..+65 -40..+65 D 3~ 400 3~ 400 3~ 400 3~ 400 -5° E 1~ 230 50 860 0,60 2,62 14,0 /400 100 -40..+55 A2b) -5° F 1~ 230 50 670 0,34 1,72 7,0 /450 60 -40..+65 A2b) A B C — — — — Air performance measured 3 905 0,53 1,15 66 895 0,57 1,19 65 A 3 890 0,60 1,20 67 B 1 730 0,36 0,63 61 B 2 705 0,38 0,66 60 Suction-side noise levels: B 3 690 0,40 0,68 61 LwA as per ISO 13347, C 1 685 0,29 0,81 60 C 2 675 0,31 0,82 60 C 3 660 0,33 0,83 61 D 1 560 0,18 0,35 56 D 2 535 0,19 0,37 55 D 3 520 0,19 0,39 55 in ebm-papst full nozzle accidental contact 0,3 80 LpA measured at 1 m distance 60 to fan axis B 3 The acoustic values given are 0,2 C only valid under the measur- 1 2 ment conditions listed and 2 40 3 may vary depending on the D installation situation. 2 1 With any deviation to the stan- 0,1 2 1 dard setup, the specific values 20 have to be checked and re1 viewed once installed or fitted! For detailed information see page 36 ff. 1000 2000 18 2000 4000 3000 4000 6000 5000 8000 6000 7000 [CFM] 10000 [m3/h] LwA [dB(A)] 2 and without protection against 3 I [A] 1 Installation category A, 2 P1 [kW] A as per: ISO 5801, A n [rpm] A 2 0,4 [in H O] [Pa] Curves 0 F1b)/F2b) (1) Nominal data in operating point 3 with maximum load subject to alterations 100 F1b)/F2b) AC_HyBlade_05_2010_EN:Axial_D 17:58 Seite 19 Cable exit: Via terminal box Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Direction of air flow – – – – 06.07.2010 ❮ "V" ❮ "V" Without attachments ❮ "V" With full square nozzle With guard grille for short nozzle "V" A6D 630-AN01 -01 W6D 630-GN01 -01 S6D 630-AN01 -01 "V" A8D 630-AN01 -01 W8D 630-GN01 -01 S8D 630-AN01 -01 "V" A6E 630-AN01 -01 W6E 630-GN01 -01 S6E 630-AN01 -01 "V" A8E 630-AN01 -01 W8E 630-GN01 -01 S8E 630-AN01 -01 Direction of air flow "A" on request 100 Air performance measured 2 0,4 [in H O] [Pa] Curves as per: ISO 5801, 3 n [rpm] P1 [kW] I [A] LwA [dB(A)] E 1 905 0,52 2,27 67 E 2 885 0,56 2,44 66 E 3 860 0,60 2,62 68 F 1 690 0,31 1,60 62 F 2 680 0,32 1,65 61 F 3 670 0,34 1,72 62 Installation category A, in ebm-papst full nozzle E 90 and without protection against accidental contact 80 0,3 Suction-side noise levels: LwA as per ISO 13347, 2 70 LpA measured at 1 m distance to fan axis 60 3 F The acoustic values given are only valid under the measur- 0,2 50 ment conditions listed and 2 40 may vary depending on the 1 installation situation. 30 0,1 With any deviation to the stan1 dard setup, the specific values 20 have to be checked and reviewed once installed or fitted! 10 For detailed information see page 36 ff. 0 1000 2000 2000 4000 3000 4000 6000 5000 8000 6000 [CFM] 10000 [m3/h] 19 Drawings S. 20 ff. Electr. connections S. 34 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:58 Seite 20 AC axial fans - HyBlade® Ø 630 with motor M**110, drawings for direction of air flow "V" Mass [kg] Type Without attachments A4D A6D A8D A6E A8E -01 -01 -01 -01 -01 c 14,0 104,0 d c±3 g±2 12,5 118,0 123,0 209,5 626,0 12,5 118,0 123,0 209,5 626,0 12,5 118,0 123,0 209,5 626,0 4xM6 Depth of screw max. 12 mm ❮ "V" Cable gland Type With full square nozzle f -01 -01 -01 -01 -01 Mass [kg] f 28,9 23,5 27,4 3,5 27,4 3,5 27,4 3,5 27,4 3,5 Ø11 Ø726 206±5 W4D 630-GR01 W6D 630-GN01 W8D 630-GN01 W6E 630-GN01 W8E 630-GN01 20 750±1 805-3 142 ❮ "V" Type With guard grille for short nozzle 123,5 7 Ø750 8,5 u±4 v±3 ❮ "V" 20 S4D S6D S8D S6E S8E Mass [kg] 630-AR01 630-AN01 630-AN01 630-AN01 630-AN01 -01 -01 -01 -01 -01 h 12,5 118,0 123,0 209,5 626,0 Internal diameter of the wall ring at least 634 mm 65,5 g 98,0 224,5 627,0 Øh±2 99x99 Ø115±0,3 d±2 630-AR01 630-AN01 630-AN01 630-AN01 630-AN01 u v 19,2 46,0 101,0 17,7 60,0 86,0 17,7 60,0 86,0 17,7 60,0 86,0 17,7 60,0 86,0 Internal diameter of the wall ring at least 634 mm AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:58 Seite 21 AC axial fans - HyBlade® Ø 630 with motor M4D138, drawings for direction of air flow "V" Without attachments Mass [kg] A4D 630-AD01 -01 A4D 630-AH01 -01 22,3 154,0 144,0 277,0 c d g 18,3 149,0 130,0 252,0 Ø627±2 99x99 c±3 d±2 Type Ø162±0,3 Internal diameter of the wall ring at least 634 mm 76 8xM10 Depth of screw max. 18 mm g±2 ❮ "V" Cable gland With full square nozzle f Mass [kg] f W4D 630-GD01 -01 W4D 630-GH01 -01 38,2 48,0 34,2 23,0 Type Mass [kg] S4D 630-AD01 -01 S4D 630-AH01 -01 28,5 87,0 134,0 24,5 82,0 109,0 Ø11 Ø696 229±5 Type 750±1 805-3 20 150 ❮ "V" With guard grille for short nozzle u v 4 143±3 Internal diameter of the wall ring at least 634 mm Ø750 Ø720 u±4 10 v±3 ❮ "V" 21 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:58 Seite 22 AC axial fans - HyBlade® Ø 710 *6D 710 M6D 110-IA -5° *6E 710 M6E 110-IA -10° kW A ∆ Y ∆ Y ∆ Y 50 50 50 50 50 50 1350 1095 905 730 880 670 2,38 1,66 1,03 0,69 0,84 0,53 4,50 2,76 2,35 1,34 1,74 0,94 50 900 0,63 2,79 F 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 G 1~ 230 A B C D E Electr. connection -5° rpm Perm. amb. temp. M6D 138-HF Hz Max. operative range *6D 710 VAC Capacitor -10° Max. current draw (1) M4D 138-LA Max. power input (1) *4D 710 Speed/rpm (1) Motor Frequency Type Nominal voltage Nominal data Curve Blade angle – Material: Guard grille: Steel, phosphated and coated in black plastic Wall ring: Sheet steel, pre-galvanised and coated in black plastic Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics Rotor: Encased in aluminium – Number of blades: 5 – Direction of rotation: E F G counter-clockwise, A B C D clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharge holes: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings – Motor protection: Design with thermal overload protector µF/VDB Pa °C p. 34 250 160 125 80 115 68 -40..+60 -40..+60 -40..+65 -40..+65 -40..+50 -40..+50 105 -40..+65 — — — — — — 14,0 /450 Air performance measured F1b)/F2b) A2b) 1380 2,00 3,92 81 1365 2,23 4,24 83 A 3 1350 2,38 4,50 86 B 1 1165 1,47 2,50 76 B 2 1125 1,59 2,71 78 Suction-side noise levels: B 3 1095 1,66 2,76 81 LwA as per ISO 13347, C 1 925 0,86 2,18 69 C 2 915 0,94 2,26 70 C 3 905 1,03 2,35 73 D 1 780 0,62 1,19 65 D 2 755 0,66 1,27 65 D 3 730 0,69 1,34 68 E 1 915 0,63 1,52 70 With any deviation to the stan- E 2 895 0,74 1,63 68 dard setup, the specific values E 3 880 0,84 1,74 71 F 1 755 0,43 0,77 65 F 2 710 0,48 0,85 63 F 3 670 0,53 0,94 65 and without protection against 0,8 accidental contact 2 LpA measured at 1 m distance 3 to fan axis B 0,6 160 The acoustic values given are C only valid under the measur- 3 120 2 3 E ment conditions listed and 1 0,4 may vary depending on the installation situation. 2 D 80 3 2 1 3 0,2 2 1 2 F 40 1 have to be checked and re- 1 viewed once installed or fitted! 1 For detailed information see page 36 ff. 0 4000 4000 8000 8000 12000 12000 16000 20000 [CFM] [m3/h] LwA [dB(A)] 2 in ebm-papst full nozzle A I [A] 1 Installation category A, 240 P1 [kW] A as per: ISO 5801, 3 n [rpm] A 2 1,0 [in H O] [Pa] Curves 22 F1b)/F2b) (1) Nominal data in operating point 3 with maximum load subject to alterations 200 F1b)/F2b) AC_HyBlade_05_2010_EN:Axial_D 17:58 Seite 23 Cable exit: Via terminal box Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Direction of air flow – – – – 06.07.2010 ❮ "V" ❮ "V" Without attachments ❮ "V" With full square nozzle With guard grille for short nozzle "V" A4D 710-AF01 -01 W4D 710-GF01 -01 S4D 710-AF01 -01 "V" A6D 710-AH01 -01 W6D 710-GH01 -01 S6D 710-AH01 -01 "V" A6D 710-AQ01 -01 W6D 710-GQ01 -01 S6D 710-AQ01 -01 "V" A6E 710-AR03 -01 W6E 710-GR03 -01 S6E 710-AR03 -01 Direction of air flow "A" on request Air performance measured 2 [in H O] [Pa] Curves as per: ISO 5801, n [rpm] P1 [kW] I [A] LwA [dB(A)] G 1 935 0,50 2,24 73 G 2 920 0,56 2,51 73 G 3 900 0,63 2,79 77 Installation category A, 3 in ebm-papst full nozzle 0,4 100 and without protection against G accidental contact Suction-side noise levels: 80 0,3 LwA as per ISO 13347, LpA measured at 1 m distance 2 to fan axis 60 The acoustic values given are 0,2 only valid under the measurment conditions listed and may vary depending on the installation situation. 40 1 With any deviation to the stan0,1 dard setup, the specific values have to be checked and re- 20 viewed once installed or fitted! For detailed information see page 36 ff. 0 1000 2000 2000 4000 3000 4000 6000 5000 8000 6000 7000 [CFM] 10000 [m3/h] 23 Drawings S. 24 ff. Electr. connections S. 34 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:59 Seite 24 AC axial fans - HyBlade® Ø 710 with motor M**110, drawings for direction of air flow "V" Without attachments Mass [kg] A6D 710-AQ01 -01 A6E 710-AR03 -01 14,0 118,0 113,0 c 14,0 111,0 Ø703±2 99x99 Ø115±0,3 d±2 c±3 Type Internal diameter of the wall ring at least 710 mm 65,5 224,5±2 4xM6 Depth of screw max. 12 mm ❮ "V" Cable gland With full square nozzle f Mass [kg] f W6D 710-GQ01 -01 W6E 710-GR03 -01 29,9 25,5 29,9 25,5 Type Mass [kg] u S6D 710-AQ01 -01 S6E 710-AR03 -01 20,5 29,0 20,5 22,0 Ø11 Ø792 199±5 Type 20 160 810±1 850-3 ❮ "V" With guard grille for short nozzle 154,5 8,5 Ø853 7 u±4 70±3 ❮ "V" 24 Internal diameter of the wall ring at least 710 mm d 96,0 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:59 Seite 25 AC axial fans - HyBlade® Ø 710 with motor M*D138, drawings for direction of air flow "V" Without attachments Mass [kg] A4D 710-AF01 -01 A6D 710-AH01 -01 22,6 142,0 110,0 277,0 c d g 18,8 148,0 126,0 252,0 Ø701±1 99x99 c±3 d±2 Type Ø162±0,3 Internal diameter of the wall ring at least 710 mm 76 8xM10 Depth of screw max. 18 mm g±2 ❮ "V" Cable gland With full square nozzle f Mass [kg] f W4D 710-GF01 -01 W6D 710-GH01 -01 39,9 17,0 36,7 --- Type Mass [kg] u v S4D 710-AF01 -01 S6D 710-AH01 -01 30,5 31,0 90,0 26,6 37,0 65,0 Ø14,5 Ø772 260±5 Type 810±1 850-3 20 170 ❮ "V" With guard grille for short nozzle 4 187±3 Internal diameter of the wall ring at least 710 mm Ø853 Ø821 u±4 10 v±3 ❮ "V" 25 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:59 Seite 26 AC axial fans - HyBlade® Ø 800 *8D 800 M8D 138-LA *ZD 800 MZD 138-HF B C D E F G 0° A ∆ Y ∆ Y ∆ Y ∆ Y 50 50 50 50 50 50 50 50 900 700 880 670 660 485 435 340 2,33 1,59 1,94 1,21 0,99 0,58 0,36 0,20 4,85 2,87 3,90 2,23 2,37 1,21 1,12 0,47 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 A 0° kW H Electr. connection 0° rpm Perm. amb. temp. M6D 138-LA Hz Max. operative range *6D 800 VAC Capacitor +5° Max. current draw (1) M6D 138-NA Max. power input (1) *6D 800 Speed/rpm (1) Motor Frequency Type Nominal voltage Nominal data Curve Blade angle – Material: Guard grille: Steel, phosphated and coated in black plastic Wall ring: Sheet steel, pre-galvanised and coated in black plastic Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics Rotor: Encased in aluminium – Number of blades: 5 – Direction of rotation: clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharge holes: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings – Motor protection: Design with thermal overload protector µF/VDB Pa °C p. 34 120 75 160 92 105 54 40 23 -40..+50 -40..+50 -40..+60 -40..+60 -40..+65 -40..+65 -40..+65 -40..+65 — — — — — — — — Air performance measured F1b)/F2b) F1b)/F2b) 920 1,99 4,59 74 910 2,10 4,69 74 A 3 900 2,33 4,85 76 B 1 750 1,39 2,58 69 B 2 735 1,44 2,68 69 Suction-side noise levels: B 3 700 1,59 2,87 70 LwA as per ISO 13347, C 1 910 1,58 3,44 72 C 2 900 1,72 3,60 73 C 3 880 1,94 3,90 77 D 1 740 1,08 1,98 66 D 2 710 1,13 2,08 67 D 3 670 1,21 2,23 70 and without protection against accidental contact 0,6 C 140 120 LpA measured at 1 m distance 3 to fan axis A 2 0,4 The acoustic values given are 3 D only valid under the measurment conditions listed and 80 2 3 may vary depending on the B 2 installation situation. 60 1 0,2 2 40 With any deviation to the standard setup, the specific values 1 1 have to be checked and reviewed once installed or fitted! 1 20 For detailed information see page 36 ff. 0 4000 5000 8000 10000 15000 12000 20000 16000 [CFM] 25000 [m3/h] +5˚ LwA [dB(A)] 2 in ebm-papst full nozzle 3 I [A] 1 Installation category A, 160 P1 [kW] A as per: ISO 5801, 180 n [rpm] A 2 [in H O] [Pa] Curves 26 F1b)/F2b) (1) Nominal data in operating point 3 with maximum load subject to alterations 100 F1b)/F2b) AC_HyBlade_05_2010_EN:Axial_D 17:59 Seite 27 Cable exit: Via terminal box Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Direction of air flow – – – – 06.07.2010 ❮ "V" ❮ "V" Without attachments ❮ "V" With full square nozzle With guard grille for full nozzle "V" A6D 800-AU01 -01 W6D 800-GU01 -01 S6D 800-CU01 -01 "V" A6D 800-AD01 -01 W6D 800-GD01 -01 S6D 800-CD01 -01 "V" A8D 800-AD01 -01 W8D 800-GD01 -01 S8D 800-CD01 -01 "V" AZD 800-AG03 -01 WZD 800-GG03 -01 SZD 800-CG03 -01 Direction of air flow "A" on request Air performance measured n [rpm] P1 [kW] I [A] LwA [dB(A)] E 1 685 0,77 2,10 65 E 2 675 0,85 2,20 66 E 3 660 0,99 2,37 74 F 1 555 0,51 1,07 60 F 2 530 0,53 1,12 60 Suction-side noise levels: F 3 485 0,58 1,21 66 LwA as per ISO 13347, G 1 450 0,32 1,09 55 G 2 445 0,34 1,10 55 G 3 435 0,36 1,12 59 H 1 365 0,18 0,43 51 H 2 355 0,19 0,45 49 H 3 340 0,20 0,47 52 2 [in H O] [Pa] Curves as per: ISO 5801, Installation category A, 3 in ebm-papst full nozzle 0,4 100 and without protection against E accidental contact 0,3 80 LpA measured at 1 m distance 2 to fan axis 60 The acoustic values given are 3 only valid under the measur- 0,2 F ment conditions listed and may vary depending on the 40 2 G 3 installation situation. 1 0,1 With any deviation to the stan- 2 H dard setup, the specific values 3 20 1 have to be checked and re- 2 viewed once installed or fitted! 1 1 For detailed information see page 36 ff. 0 4000 4000 8000 8000 12000 12000 16000 20000 [CFM] [m3/h] 27 Drawings S. 28 Electr. connections S. 34 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:59 Seite 28 AC axial fans - HyBlade® Ø 800 with motor M*D138, drawings for direction of air flow "V" Mass [kg] Type Without attachments A6D A6D A8D AZD -01 -01 -01 -01 c d 23,0 159,0 149,0 277,0 23,0 159,0 149,0 277,0 19,0 159,0 149,0 252,0 Ø162±0,3 Ø788±1 Internal diameter of the wall ring at least 795 mm 76 8xM10 Depth of screw max. 18 mm g±2 ❮ "V" Cable gland Type With full square nozzle f -01 -01 -01 -01 Mass [kg] f 46,6 36,0 44,2 --- 44,2 --- 40,2 --- Mass [kg] s Ø14,5 Ø857 283±5 W6D 800-GU01 W6D 800-GD01 W8D 800-GD01 WZD 800-GG03 910±1 970-3 17 190 ❮ "V" Type 68 15,5 26 Ansicht X 15±0,5 7,5 With guard grille for full nozzle S6D S6D S8D SZD 800-CU01 800-CD01 800-CD01 800-CG03 -01 -01 -01 -01 Ø816 Ø861 s±4 t±3 ❮ "V" 28 t 33,3 162,0 211,0 30,1 127,0 169,0 30,1 127,0 169,0 26,2 127,0 144,0 92 108±3 g 26,5 172,0 171,0 297,0 99x99 c±3 d±2 800-AU01 800-AD01 800-AD01 800-AG03 Internal diameter of the wall ring at least 795 mm AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:59 Seite 29 29 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:59 Seite 30 AC axial fans - HyBlade® Ø 910 *ZD 910 MZD 138-HF A ∆ Y ∆ Y ∆ Y 50 50 50 50 50 50 885 685 650 475 420 305 2,48 1,57 1,15 0,64 0,41 0,21 5,15 2,90 2,78 1,36 1,13 0,48 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 A B C D E 0° kW F Electr. connection 0° rpm Perm. amb. temp. M8D 138-LA Hz Max. operative range *8D 910 VAC Capacitor 0° Max. current draw (1) M6D 138-NA Max. power input (1) *6D 910 Speed/rpm (1) Motor Frequency Type Nominal voltage Nominal data Curve Blade angle – Material: Guard grille: Steel, phosphated and coated in black plastic Wall ring: Sheet steel, pre-galvanised and coated in black plastic Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics Rotor: Encased in aluminium – Number of blades: 5 – Direction of rotation: clockwise, seen on rotor – Type of protection: IP 54 (acc. to EN 60529) – Insulation class: "F" – Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request – Condensate discharge holes: Rotor-side – Mode of operation: Continuous operation (S1) – Bearings: Maintenance-free ball bearings – Motor protection: Design with thermal overload protector µF/VDB Pa °C p. 34 150 90 90 47 38 20 -40..+50 -40..+50 -40..+65 -40..+65 -40..+65 -40..+65 — — — — — — [in H2O] Air performance measured 75 4,88 75 A 3 885 2,48 5,15 77 B 1 750 1,41 2,67 70 B 2 715 1,49 2,82 69 Suction-side noise levels: B 3 685 1,57 2,90 71 LwA as per ISO 13347, C 1 675 0,95 2,57 68 C 2 665 1,05 2,67 67 C 3 650 1,15 2,78 70 D 1 530 0,59 1,24 61 D 2 500 0,62 1,31 59 D 3 475 0,64 1,36 63 0,60 0,50 LpA measured at 1 m distance 0,40 The acoustic values given are only valid under the measur- 3 B ment conditions listed and may vary depending on the installation situation. C 60 0,20 2 2 D With any deviation to the stan- 1 3 dard setup, the specific values 40 2 1 0,10 20 4,67 2,26 to fan axis 0,30 80 2,05 900 3 3 have to be checked and re- 1 viewed once installed or fitted! 1 For detailed information see page 36 ff. 0 5000 5000 30 10000 10000 15000 [CFM] 15000 20000 25000 30000 [m3/h] LwA [dB(A)] 915 accidental contact 2 I [A] 2 and without protection against 140 P1 [kW] 1 in ebm-papst full nozzle A n [rpm] A Installation category A, 160 100 F1b)/F2b) A as per: ISO 5801, 0,70 [Pa] Curves 120 F1b)/F2b) (1) Nominal data in operating point 3 with maximum load subject to alterations 180 F1b)/F2b) AC_HyBlade_05_2010_EN:Axial_D 17:59 Seite 31 Cable exit: Via terminal box Protection class: I (acc. to EN 61800-5-1) Product conforming to standard: CE Approvals: VDE (acc. to EN 60034) Direction of air flow – – – – 06.07.2010 ❮ "V" ❮ "V" Without attachments ❮ "V" With full square nozzle With guard grille for full nozzle "V" A6D 910-AA01 -01 W6D 910-GA01 -01 S6D 910-CA01 -01 "V" A8D 910-AD03 -01 W8D 910-GD03 -01 S8D 910-CD03 -01 "V" AZD 910-AG03 -01 WZD 910-GG03 -01 SZD 910-CG03 -01 Direction of air flow "A" on request 40 Air performance measured 2 0,16 [in H O] [Pa] Curves as per: ISO 5801, P1 [kW] I [A] LwA [dB(A)] E 1 440 0,34 1,08 57 E 2 430 0,37 1,10 56 E 3 420 0,41 1,13 59 F 1 340 0,19 0,44 51 F 2 325 0,20 0,46 49 F 3 305 0,21 0,48 50 Installation category A, in ebm-papst full nozzle 3 and without protection against accidental contact E 0,12 Suction-side noise levels: 30 n [rpm] LwA as per ISO 13347, LpA measured at 1 m distance to fan axis 2 0,08 The acoustic values given are 20 only valid under the measur- 3 ment conditions listed and F may vary depending on the installation situation. 2 1 With any deviation to the stan- 0,04 10 dard setup, the specific values have to be checked and re- 1 viewed once installed or fitted! For detailed information see page 36 ff. 0 2000 2000 4000 4000 6000 6000 8000 10000 8000 12000 14000 [CFM] [m3/h] 31 Drawings S. 32 Electr. connections S. 34 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:59 Seite 32 AC axial fans - HyBlade® Ø 910 with motor M*D138, drawings for direction of air flow "V" Without attachments Mass [kg] A6D 910-AA01 -01 A8D 910-AD03 -01 AZD 910-AG03 -01 26,9 297,0 g 23,7 277,0 19,8 252,0 Ø904±1 99x99 Ø162±0,3 149±3 119±2 Type 76 Internal diameter of the wall ring at least 913 mm 8xM10 Depth of screw max. 18 mm g±2 ❮ "V" Cable gland With full square nozzle f Mass [kg] f W6D 910-GA01 -01 W8D 910-GD03 -01 WZD 910-GG03 -01 51,6 19,0 48,4 --- 44,5 --- Type Mass [kg] t S6D 910-CA01 -01 S8D 910-CD03 -01 SZD 910-CG03 -01 34,9 209,0 Ø14,5 Ø976 277±5 Type 20 205 1010±1 1070-3 ❮ "V" 76 44 Ø931 Ø983 106 88 137±4 t±3 ❮ "V" 32 31,6 189,0 27,8 164,0 29 View X 15±0,5 10,5 With guard grille for full nozzle Internal diameter of the wall ring at least 913 mm AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:59 Seite 33 33 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:59 Seite 34 Electrical connections AC Fans (1~ 230 VAC power line) Fans, 2 speeds via ∆/Y-switch (3~ 400 VAC power line) A2b) Single-phase capacitor motor F1b) Delta connection (high speed) with connection for external TOP C U1 Z U2 L N PE Fans with terminal box TOP TOP U1 = blue U2 = black Z = brown = green/ yellow F2b) Star connection (low speed) with TOP with TOP U1 V1 W1 W2 U2 V2 TOP TOP L1 L2 L3 Fans with terminal box PE U1 U2 V1 V2 W1 W2 = = = = = = = black green blue white brown yellow green/ yellow U1 V1 W1 W2 U2 V2 TOP TOP L1 L2 L3 Fans with terminal box Direction of rotation is reversed by swapping two line phases. 34 PE U1 U2 V1 V2 W1 W2 = = = = = = = black green blue white brown yellow green/ yellow AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:59 Seite 35 35 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:59 Seite 36 Technical parameters & scope High standards for all ebm-papst products Here at ebm-papst, we constantly strive to further improve our products in order to be able to offer you the best possible product for your application. Careful monitoring of the market ensures that technical innovations are reflected in the improvements of our products. Based on the technical parameters listed below and the ambience you want our product to operate in, we here at ebm-papst can always work out the best solution for your specific application. General performance parameters Service life Any deviations from the technical data and parameters described here The service life of ebm-papst products depends on two major factors: are listed on the product-specific data sheet. – The service life of the insulation system – The service life of the bearing system Type of protection The service life of the insulation system mainly depends on voltage level, The type of protection is specified in the product-specific data sheets. temperature and ambient conditions, such as humidity and condensation. The service life of the bearing system depends mainly on the thermal load Insulation class on the bearing. The insulation class is specified in the product-specific data sheets. The majority of our products use maintenance-free ball bearings for any mounting position possible. As an option, sleeve bearings can be Mounting position used, which is indicated on the product-specific data sheet wherever The mounting position is specified in the product-specific data sheets. applicable. The service life L10 of the ball bearings can be taken as approx. 40,000 Condensate discharge holes operating hours at an ambient temperature of 40 °C, yet this estimate Information on the condensate discharge holes is provided in the can vary according to the actual ambient conditions. product-specific data sheets. We will gladly provide you with a lifetime calculation taking into account your specific operating conditions. Mode of operation The mode of operation is specified in the product-specific data sheets. Motor protection / thermal protection Information on motor protection and thermal protection is provided in the Protection class product-specific data sheets. The protection class is specified in the product-specific data sheets.. Depending on motor type and field of application, the following protective features are realised: – Thermal overload protection (TOP), either in-circuit or external – PTC with electronic diagnostics – Impedance protection – Thermal overload protection (TOP) with electronic diagnostics – Current limitation via electronics If an external TOP is connected, the customer has to make sure to connect a conventional trigger device for switching it off. Products without fitted TOP and without protection against improper use, a motor protection complying with the valid standards has to be installed. 36 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:59 Seite 37 Left: Endurance test room Middle: Shock test Right: Chamber test rig Mechanical strain / performance parameters Legal and normative directives All ebm-papst products are subjected to comprehensive tests complying The products described in this catalogue are designed, developed and with the normative specifications. In addition to this, the tests also reflect produced in keeping with the standards in place for the relevant product the vast experience and expertise of ebm-papst. and, if known, the conditions governing the relevant fields of application. Vibration test Standards Vibration tests are carried out in compliance with Information on standards is provided in the product-specific data sheets. – Vibration test in operation according to DIN IEC 68, parts 2-6 – Vibration test at standstill according to DIN IEC 68, parts 2-6 EMC Information on EMC standards is provided in the product-specific data Shock load sheets. Shock load tests are carried out in compliance with Complying with the EMC standards has to be established on the final – Shock load according to DIN IEC 68, parts 2-27 appliance, as different mounting situations can result in changed EMC properties. Balancing quality Testing the balancing quality is carried out in compliance with Leakage current – Residual imbalance according to DIN ISO 1940 Information on the leakage current is provided in the product-specific – Standard balancing quality level G 6.3 data sheets. Should you require a higher balancing quality level for your specific Measuring is according to IEC 60990. application, please let us know and specify this when ordering your product. Approvals In case you require a specific approval for your ebm-papst product Chemo-physical strain / performance parameters (VDE, UL, GOST, CCC, CSA, etc.) please let us know. Should you have questions about chemo-physical strain, please direct Most of our products can be supplied with the relevant approval. them to your ebm-papst contact. Information on existing approvals is provided in the product-specific data sheets. Fields of application, industries and applications Our products are used in various industries and applications: Air performance measurements Ventilation, air-conditioning and refrigeration technology, clean room All air performance measurements are carried out on suction side and on technology, automotive and rail technology, medical and laboratory tech- chamber test beds conforming to the specifications as per ISO 5801 and nology, electronics, computer and office technology, telecommunications, DIN 24163. The fans under test are installed in the measuring chamber at household appliances, heating, machines and plants, drive engineering. free air intake and exhaust (installation category A) and are operated at Our products are not designed for use in the aviation and aerospace nominal voltage, with AC also at nominal frequency, and without any industry! additional components such as guard grilles. As required by the standard, the air performance curves correspond to an air density of 1.2 kg/m3. 37 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:59 Seite 38 Room for precision noise measuring Measurement conditions for air and noise measurement ebm-papst products are measured under the following conditions: – Axial and diagonal fans in direction of rotation “V” in full nozzle and without guard grille – Backward curved centrifugal fans, free-running and with inlet nozzle – Forward curved single and dual inlet centrifugal fans with housing Noise measurements All noise measurements are carried out in low-reflective test rooms with reverberant floor. Thus the ebm-papst acoustic test chambers meet the requirements of precision class 1 according to DIN EN ISO 3745. For noise measurement, the fans being tested are placed in a reverberant wall and operated at nominal voltage (for AC, also at nominal frequency) without additional attachments such as the guard grille. Sound pressure level and sound level All acoustic values are established according to ISO 13347, DIN 45635 and ISO 3744/3745 to accuracy class 2 and given in A-rated form. When the sound pressure level (Lp) is measured, the microphone is on the intake side of the fan being tested, usually at a distance of 1 m on the fan axis. To measure the sound level (Lw), 10 microphones are distributed over an enveloping surface on the intake side of the fan being tested 1,5d (see graphic). The sound level measured can be roughly calculated D from the sound pressure level by adding 7 dB. Measuring configuration as per ISO 13347-3 respectively DIN 45635-38: 10 measuring points h 3d d≥D h = 1,5d ... 4,5d Measurement area S = 6d2 + 7d (h + 1,5d) 38 2d 17:59 Seite 39 Adding multiple noise sources with the same level 15 06.07.2010 [dB] AC_HyBlade_05_2010_EN:Axial_D pressure level of a fan is approximately 75 dB(A). The level increase measured from the diagram is 9 dB. Thus the overall sound level of the installation can be expected to be 84 dB(A). 10 9 5 Example: 8 A3G800 axial fans are on a condenser. According to the data sheet, the sound 0 The noise characteristics of multiple identical fans can be determined in advance based on the noise values specified in the data sheet. This is shown in the diagram opposite. Increase in sound pressure / sound power level Adding 2 noise sources with the same volume results in a level increase of approx. 3 dB. 1 2 5 8 10 15 20 25 3 Adding two noise sources with different levels [dB] Number of sources of sound with identical level the overall sound level of the unit can be expected to be 76.5 dB(A). 2 1,5 4 dB. The level increase can now be read in the diagram as approx. 1.5 dB. This means that 1 Example: There is an axial fan A3G800 with a sound pressure level of 75 dB(A) at the operating point and an axial fan A3G710 with 71 dB(A) in a ventilation unit. The level difference is 0 levels given in the data sheet. This is shown in the diagram opposite. Increase in sound pressure / sound power level The acoustic performance of two different fans can be predetermined based on the sound 0 4 8 12 16 20 24 [dB] 0 Distance laws [dB] Difference in level with two sources of sound Sound power level is independent of distance to the sound source. In contrast to this, sound -10 pressure level decreases the further away the noise source is. The adjacent diagram shows the decrease in level under far sound field conditions. Far sound field conditions apply when- levels can be considerably smaller. The following example only applies to far sound field conditions and can vary strongly depending on the installation effects: With an axial fan A3G300, a sound pressure level of 65 dB(A) was measured at a distance of 1 m. According to the adjacent diagram, at a distance of 20 m we would get a reduction by -20 -26 -30 -40 vant literature on this complex topic. Per doubling of distance, the level in the far sound field decreases by 6 dB. In the near field of the fan, other correlations apply and the decrease in Decrease in sound pressure level ever the distance between microphone and fan is big when compared to fan diameter and wavelength to be considered. For more information on far sound field, please consult the rele- 1 Distance 2 5 10 20 50 100 [m] 26 dB, i.e. a sound pressure level of 39 dB(A). 39 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 fan agent compact fan agent 17:59 Seite 40 ebm-papst representatives & subsidiaries motor specialist motor agent Germany ebm-papst Mulfingen GmbH & Co. KG ebm-papst St. Georgen GmbH & Co. KG ebm-papst Landshut GmbH Bachmühle 2 D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 [email protected] Hermann-Papst-Straße 1 D-78112 St. Georgen Phone +49 7724 81-0 Fax +49 7724 81-1309 [email protected] Hofmark-Aich-Straße 25 D-84030 Landshut Phone +49 871 707-0 Fax +49 871 707-465 [email protected] www.ebmpapst.com www.ebmpapst.com www.ebmpapst.com Agencies Berlin Dipl.-Ing. (TH) Jens Duchow Händelstraße 7 D-16341 Panketal Phone +49 30 944149-62 Fax +49 30 944149-63 [email protected] Bielefeld Dipl.-Ing. (FH) Wolf-Jürgen Weber Niehausweg 13 D-33739 Bielefeld Phone +49 5206 91732-31 Fax +49 5206 91732-35 [email protected] Dortmund Dipl.-Ing. (FH) Hans-Joachim Pundt Auf den Steinern 3 D-59519 Möhnesee-Völlinghausen Phone +49 2925 800-407 Fax +49 2925 800-408 [email protected] Frankfurt Dipl.-Ing. Christian Kleffmann Dr.-Hermann-Krause-Straße 23 D-63452 Hanau Phone +49 6181 1898-12 Fax +49 6181 1898-13 [email protected] Halle Dipl.-Ing. (TU) Michael Hanning Lerchenweg 4 D-06120 Lieskau Phone +49 345 55124-56 Fax +49 345 55124-57 [email protected] Hamburg Ingenieurbüro Breuell GmbH Ing. Dirk Kahl Elektroingenieur Grützmühlenweg 40 D-22339 Hamburg Phone +49 40 538092-19 Fax +49 40 538092-84 [email protected] 40 Kassel Dipl.-Ing. (FH) Ralph Brück Hoherainstraße 3 b D-35075 Gladenbach Phone +49 6462 4071-10 Fax +49 6462 4071-11 [email protected] Koblenz Winfried Schaefer Hinter der Kirch 10 D-56767 Uersfeld Phone +49 2657 16-96 Fax +49 2657 16-76 [email protected] Munich Dipl.-Wirt.-Ing. (FH) Jens Peter Uhlandstraße 6 D-74427 Fichtenberg Phone +49 7971 260-180 Fax +49 7971 260-221 [email protected] Nuremberg Friedrich Klein Adlerstraße 49/1 D-73540 Heubach Phone +49 7173 4983 Fax +49 7173 8053 [email protected] Offenburg Dipl.-Ing. (FH) Ralf Braun Hubeneck 21 D-77704 Oberkirch Phone +49 7802 9822-52 Fax +49 7802 9822-53 [email protected] Stuttgart Dipl.-Ing. (FH) Rudi Weinmann Hindenburgstraße 100/1 D-73207 Plochingen Phone +49 7153 9289-80 Fax +49 7153 9289-81 [email protected] Ulm Dipl.-Wirt.-Ing. (FH) Axel Resch Bachmühle 2 D-74673 Mulfingen Phone +49 7938 81-7092 Fax +49 7938 81-110 [email protected] Distributors Frankfurt R.E.D. Handelsgesellschaft mbH Gutenbergstraße 3 D-63110 Rodgau - Jügesheim Phone +49 6106 841-0 Fax +49 6106 841-111 [email protected] www.red-elektromechanik.de Hamburg Breuell + Hilgenfeldt GmbH Grützmühlenweg 40 D-22339 Hamburg Phone +49 40 538092-20 Fax +49 40 538092-84 [email protected] Munich A. Schweiger GmbH Ohmstraße 1 D-82054 Sauerlach Phone +49 8104 897-0 Fax +49 8104 897-90 [email protected] www.schweiger-gmbh.com (1 to 5 pieces) North Breuell + Hilgenfeldt GmbH Grützmühlenweg 40 D-22339 Hamburg Phone +49 40 538092-20 Fax +49 40 538092-84 [email protected] South HDS Ventilatoren Vertriebs GmbH Glaswiesenstraße 1 D-74677 Dörzbach Phone +49 7937 8033520 Fax +49 7937 8033525 [email protected] AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 Europe Austria ebm-papst Motoren & Ventilatoren GmbH Straubingstraße 17 A-4030 Linz Phone +43 732 321150-0 Fax +43 732 321150-20 [email protected] www.ebmpapst.at Belarus ebm-papst Bel AgmbH P.O. Box 117 BY-220138 Minsk Phone +375 17 3851556 Fax +375 17 3851556 [email protected] www.ebmpapst.by Belgium ebm-papst Benelux B.V. Sales office Belgium-Luxemburg Romeinsestraat 6/0101 Research Park Haasrode B-3001 Heverlee-Leuven Phone +32 16 396-200 Fax +32 16 396-220 [email protected] www.ebmpapst.be Bulgaria ebm-papst Romania S.R.L. Str. Tirnavei Nr. 20 RO-500327 Brasov Phone +40 268 312-805 Fax +40 268 312-805 [email protected] Croatia ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 [email protected] 17:59 Seite 41 Czech Republic / Slovakia ebm-papst CZ s.r.o. Kaštanová 34a CZ-620 00 Brno Phone +420 547 232-617 Fax +420 547 232-622 [email protected] www.ebmpapst.cz Denmark ebm-papst Denmark ApS Vallensbækvej 21 DK-2605 Brøndby Phone +45 43 631111 Fax +45 43 630505 [email protected] www.ebmpapst.dk Hungary ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 [email protected] Iceland RJ Engineers Stangarhyl 1A IS-110 Reykjavik Phone +354 567 8030 Fax +354 567 8015 [email protected] www.rj.is Estonia ebm-papst Oy, Eesti Filiaal Kesk tee 13 Aaviku küla, Jüri Tehnopark EST-75301 Rae Vald, Harjumaa Phone +372 65569-78 Fax +372 65569-79 www.ebmpapst.ee Ireland ebm-papst Limited Portlaoise Business & Technology Park Mountrath Road IRL-Portlaoise, Co. Laois Phone +353 5786 643-43 Fax +353 5786 643-46 [email protected] www.ebmpapst.ie Finland ebm-papst Oy Puistotie 1 FIN-02760 Espoo Phone +358 9 887022-0 Fax +358 9 887022-13 [email protected] www.ebmpapst.fi Italy ebm-papst Srl Via Cornaggia 108 I-22076 Mozzate (Co) Phone +39 0331 836201 Fax +39 0331 821510 [email protected] www.ebmpapst.it France ebm-papst SARL ZI Nord - rue A. Mohler BP 62 F-67212 Obernai-Cedex Phone +33 820 326266 Fax +33 3 88673883 [email protected] www.ebmpapst.fr Macedonia ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 [email protected] Greece Helcoma Th. Rotas & Co OE Davaki 65 GR-17672 Kallithea-Attiki Phone +30 210 9513-705 Fax +30 210 9513-490 [email protected] www.helcoma.gr 41 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 fan agent compact fan agent 17:59 Seite 42 ebm-papst representatives & subsidiaries motor specialist motor agent Netherlands ebm-papst Benelux B.V. Engelseweg 127 NL-5705 AC Helmond Phone +31 492 502-900 Fax +31 492 502-950 [email protected] www.ebmpapst.nl Russia ebm-papst Ural GmbH Posadskaja-Strasse, 23(E), 3 RU-620102 Ekaterinburg Phone +7 343 2338000 Fax +7 343 2337788 [email protected] www.ebmpapst.ur.ru Switzerland ebm-papst AG Rütisbergstrasse 1 CH-8156 Oberhasli Phone +41 44 73220-70 Fax +41 44 73220-77 [email protected] www.ebmpapst.ch Norway ebm-papst AS P.B. 173 Holmlia N-1203 Oslo Phone +47 22 763340 Fax +47 22 619173 [email protected] www.ebmpapst.no ebm-papst Rus GmbH proezd 4529, vladenie 5, stroenie 1 RU-141000 Mytistschi, Oblast Moskau Phone +7 495 9807524 Fax +7 495 5140924 [email protected] www.ebmpapst.ru Turkey Akantel Elektronik San. Tic. LTD. Sti. Atatürk Organize Sanayi Bölgesi 10007 SK. No.:6 TR-35620 Cigli-Izmir Phone +90 232 3282090 Fax +90 232 3280270 [email protected] www.ebmpapst.com.tr Poland ebm-papst Polska Sp. z o.o. ul. Annopol 4A PL-03236 Warszawa Phone +48 22 6757819 Fax +48 22 6769587 [email protected] www.ebmpapst.pl Portugal ebm-papst (Portugal), Lda. Av. Marechal Gomes da Costa, 35 e Rua Conselheiro Emidio Navarro P-1800-255 Lisboa Phone +351 218 394-880 Fax +351 218 394-759 [email protected] www.ebmpapst.pt Romania ebm-papst Romania S.R.L. Str. Tirnavei Nr. 20 RO-500327 Brasov Phone +40 268 312-805 Fax +40 268 312-805 [email protected] 42 Serbia & Montenegro ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 [email protected] Spain ebm-papst Ibérica S.L. Avda. del Sistema Solar, 29 E-28830 San Fernando de Henares (Madrid) Phone +34 91 6780894 Fax +34 91 6781530 [email protected] Sweden ebm-papst AB Äggelundavägen 2 S-17562 Järfälla Phone +46 8 7619400 Fax +46 8 362306 [email protected] www.ebmpapst.se Ukraine ebm-papst Ukraine LLC Lepse Boulevard, 4, Building 47 UA-03067 Kiev Phone +38 044 2063091 Fax +38 044 2063091 [email protected] www.ebmpapst.ua United Kingdom ebm-papst UK Ltd. Chelmsford Business Park GB-Chelmsford Essex CM2 5EZ Phone +44 1245 468555 Fax +44 1245 466336 [email protected] www.ebmpapst.co.uk ebm-papst Automotive & Drives (UK) Ltd. The Smithy Fidlers Lane, East Ilsley GB-Berkshire RG20 7LG Phone +44 1635 2811-11 Fax +44 1635 2811-61 A&[email protected] www.ebmpapst-ad.com AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 America Argentina ebm-papst de Argentina S.A. Hernandarias 148 Lomas del Mirador Pcia. de Buenos Aires (1752) Phone +54 11 46576135 Fax +54 11 46572092 [email protected] www.ebmpapst.com.ar Brasil ebm-papst Motores Ventiladores Ltda. Av. José Giorgi, 301 Galpões B6+B7 Condominio Logical Center BR-06707-100 Cotia - São Paulo Phone +55 11 4613-8700 Fax +55 11 3164-8924 [email protected] www.ebmpapst.com.br 17:59 Seite 43 USA ebm-papst Inc. P.O. Box 4009 100 Hyde Road USA-Farmington, CT 06034 Phone +1 860 674-1515 Fax +1 860 674-8536 [email protected] www.ebmpapst.us ebm-papst Automotive & Drives, Inc. 3200 Greenfield, Suite 255 USA-Dearborn, MI 48120 Phone +1 313 406-8080 Fax +1 313 406-8081 [email protected] www.ebmpapst-automotive.us Africa South Africa ebm-papst South Africa (Pty) Ltd. P.O. Box 3124 1119 Yacht Avenue ZA-2040 Honeydew Phone +27 11 794-3434 Fax +27 11 794-5020 [email protected] www.ebmpapst.co.za Canada ebm-papst Canada Inc. 1800 Ironstone Manor, Unit 2 CDN-Pickering, Ontario, L1W3J9 Phone +1 905 420-3533 Fax +1 905 420-3772 [email protected] www.ebmpapst.ca Mexico ebm Industrial S.de R.L. de C.V. Paseo de Tamarindos 400-A-5to Piso Col. Bosques de las Lomas MEX-Mexico 05120, D.F. Phone +52 55 3300-5144 Fax +52 55 3300-5243 [email protected] www.ebmpapst.com.mx 43 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 fan agent compact fan agent 17:59 Seite 44 ebm-papst representatives & subsidiaries motor specialist motor agent Asia China ebm-papst Ventilator (Shanghai) Co., Ltd. No. 418, Huajing Road WaiGaoQiao Free Trade Zone No. 2001, Yang Gao (N) Road VRC-200131 Shanghai, P.R. of China Phone +86 21 5046-0183 Fax +86 21 5046-1119 [email protected] www.ebmpapst.com.cn Hong Kong ebm-papst Hong Kong Ltd. Unit No. 13,9 / F Technology Park, 18 On Lai Street Siu Lek Yuen, Shatin N.T. Hong Kong - P.R. of China Phone +852 2145-8678 Fax +852 2145-7678 [email protected] India ebm-papst India Pvt. Ltd. 26/3, G.N.T. Road, Erukkencherry IND-Chennai-600118 Phone +91 44 25372556 Fax +91 44 25371149 [email protected] www.ebmpapst.in Indonesia ebm-papst Indonesia Representative Office German Centre, 4th Floor, Suite 4470 Jl. Kapt. Subijono Dj. Bumi Serpong Damai RI-15321 Tangerang Phone +62 21 5376250 Fax +62 21 5388305 [email protected] Israel Polak Bros. Import Agencies Ltd. 9 Hamefalsim Street IL-Kiryat Arie, Petach-Tikva 49514 Phone +972 3 9100300 Fax +972 3 5796679 [email protected] www.polak.co.il 44 Japan ebm-papst Industries Japan K.K. 12 Floor, Benex S-3 Bldg. 3-20-8 Shinyokohama, Kohoku-ku J-222-0033 Yokohama Phone +81 45 47057-51 Fax +81 45 47057-52 [email protected] www.ebmpapst.jp Korea ebm-papst Korea Co. Ltd. 6F, Trutec Bldg. B 6-2, Digital Media City (DMC) Sangam-Dong, Mapo-Gu ROK-Seoul 121-270 Phone +82 2 366213-24 Fax +82 2 366213-26 [email protected] www.ebmpapst.co.kr Malaysia ebm-papst Malaysia Representative Office Unit 12-2, Jalan USJ Sentral 3 Persiaran Subang, Selangor Darul Ehsan MAL-47600 Subang Jaya Phone +60 3 8024-1680 Fax +60 3 8024-8718 [email protected] Singapore ebm-papst SEA Pte. Ltd. No. 23 Ubi Road 4 #06-00 Olympia Industrial Building SGP-Singapore 408620 Phone +65 65513789 Fax +65 68428439 [email protected] Taiwan ETECO Engineering & Trading Corp. 10F-I, No. 92, Teh-Wei Str. RC-Tsow-Inn District, Kaohsiung Phone +886 7 557-4268 Fax +886 7 557-2788 [email protected] www.ebmpapst.com.tw Thailand ebm-papst Thailand Co., Ltd. 99/349 Na-Nakorn Bldg., 4th Floor Chaeng Wattana Road, Thungsonghong, THA-10210 Laksi, BKK Phone +66 2 57615-24 Fax +66 2 57615-42 [email protected] United Arab Emirates ebm-papst Middle East FZE PO Box 17755 Jebel Ali Free Zone / FZS1 / AP05 UAE-Dubai Phone +971 4 88608-26 Fax +971 4 88608-27 [email protected] www.ebmpapst.ae Vietnam ebm-papst Vietnam Representative Office Room #102, 25 Nguyen Van Thu Street District 1 VN-Ho Chi Minh City Phone +84 8 39104099 Fax +84 8 39103970 [email protected] AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:59 Seite 45 Australia Australia ebm-papst A&NZ Pty Ltd. 10 Oxford Road AUS-Laverton North, Victoria, 3026 Phone +61 3 9360-6400 Fax +61 3 9360-6464 [email protected] www.ebmpapst.com.au New Zealand ebm-papst A&NZ Pty Ltd. 102 Henderson Valley Road NZ-Henderson, Auckland 1230 Phone +64 9 837-1884 Fax +64 9 837-1899 [email protected] www.ebmpapst.com.au 45 AC_HyBlade_05_2010_EN:Axial_D Notes 46 06.07.2010 17:59 Seite 46 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:59 Seite 47 47 AC_HyBlade_05_2010_EN:Axial_D 06.07.2010 17:59 Seite 48 37789-7-8811 · RÖ-07/10-3’ Printed in Germany ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone +49 (0) 79 38 / 81-0 Fax +49 (0) 79 38 / 81-110 [email protected] www.ebmpapst.com