Download

2W DC-DC Converter P2E-Series
●
●
●
●
●
●
9 Pin SIL
Wide 4:1 input range
Up to 1500 VDC isolation
MTBF > 1.2 MHours.
Continuous short circuit protection
Remote control input
Model selection guide
Typ
Single Output
P2E243R3S
P2E2405S
P2E2412S
P2E2415S
P2E483R3S
P2E4805S
P2E4812S
P2E4815S
Dual Output
P2E2405D
P2E2412D
P2E2415D
P2E4805D
P2E4812D
P2E4815D
Input
voltage
range
VDC]
Input
Current
no-load
mA]
Input
current
full-load
[mA]
Output
voltage
Output
current
[VDC]
[mA]
Load regulation
@
load
range
Efficiency
typ. @
full load
[%]
Filter
inductance
L1
[µH]
Filter
capacity
C2
C-Load
max.
[µF]
9…36
9…36
9…36
9…36
18...75
18...75
18...75
18...75
10
10
10
10
5
5
5
5
92
103
100
98
46
53
50
50
3.3
5.0
12.0
15.0
3.3
5.0
12.0
15.0
0...500
0...400
0...165
0...135
0...500
0...400
0...165
0...135
1%
1%
0.5%
0.5%
1%
1%
0.5%
0.5%
10...100%
10...100%
0...100%
0...100%
10...100%
10...100%
0...100%
0...100%
75
81
84
85
75
80
84
84
6.8
6.8
6.8
6.8
68
68
68
68
4.7µF
4.7µF
4.7µF
4.7µF
1µF
1µF
1µF
1µF
X7R
X7R
X7R
X7R
X7R
X7R
X7R
X7R
2200
1000
160
100
2200
1000
160
100
9…36
9…36
9…36
18...75
18...75
18...75
10
10
10
5
5
5
103
101
102
53
52
50
±5.0
±12.0
±15.0
±5.0
±12.0
±15.0
±0...200
±0...85
±0...65
±0...200
±0...85
±0...65
1%
1%
1%
1%
1%
1%
10...100%
10...100%
10...100%
10...100%
10...100%
10...100%
81
83
82
80
81
84
6.8
6.8
6.8
68
68
68
4.7µF
4.7µF
4.7µF
1µF
1µF
1µF
X7R
X7R
X7R
X7R
X7R
X7R
2 x 470
2 x 100
2 x 47
2 x 470
2 x 100
2 x 47
Page 1 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
2W DC-DC Converter P2E-Series
EFT & Surge (for EN61000-4-4 and EN61000-4-5)
The external filter capacitor C1 is required if the module has to meet EN61000-4-4 class B and
EN61000-4-5 class B.
EMI Filter (for EN55022 class A)
Input filter components (C2, L1) are used to help meet conducted emissions requirement for the module.
These components should be mounted as close as possible to the module; and all leads should be
minimized to decrease radiated noise.
L1 see table
Coiltronics SD3118 series
+ Vin
C1 + C2
220µF
100V
See
KR series
table
NipponChemicon
2
1k
6
3
+ Vout
max. C-Load
see table
Rem. ctrl voltage
“Off” 2.7..15V
“On” 0..0.6V or
open input
1
9
- Vin
- Vout
Efficiency versus output current
Page 2 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
2W DC-DC Converter P2E-Series
Specifications
Input
Absolute max. voltage for 100
ms
Input current at standby mode
Star up time (with resistive load)
Filter
Remote on/off controll
Isolation:
Rated voltage for 60 s, input /
output (Tested for 3 s)
Resistance
Capacitance
Output
Voltage accuracy
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Short circuit restart
Line voltage regulation
Dual output cross regulation
Temperature coefficient
Transient recovery time
Transient response deviation
General
Switching frequency
Safety standard in
accordance with
24 V type –0.7..50 VDC
48 V type –0.7..100 VDC
5 mA max.
10ms, typ.
Capacitors
on: open or 0…0.6V
off: 2.7…15 VDC
1500 VDC
9
10 Ω
500 pF, typ.
±1%
50 mVp-p, max.
Continuous
Automatic
± 0.5 %
±5%
± 0.02 % / °C
300µs, typ.
± 3 %, typ.
EMI (see circuit diagram page 1)
Conducted emissions
Radiated emissions
ESD
RS
EFT
Surge
CS
PFMF
Environmental
Operating temperatur
(ambient)
Case temperature
Storage temperature
Derating
Humidity
Cooling
Physical
Dimensions SIP8
Weight
Case material standard
version
Potting material
Pin soldering temperature
250 kHz
IEC60950
Dimensions
EN55022 class A
EN55022 class A
IEC61000-4-2 perf. criteria B
IEC61000-4-3 perf. criteria A
IEC61000-4-4 perf. criteria B
IEC61000-4-5 perf. criteria B
IEC61000-4-6 perf. criteria A
IEC61000-4-8 perf. criteria A
-40 °C to +85°C
(see derating curve)
100 °C, max.
-40 °C ... +125 °C
See curve
Up to 95 %,
non-condensing
Free-air convection
26 x 9.3 x 12,5 mm
6.5 g
non-conductive black plastic,
UL94-V0
Epoxy UL94-V0
260 C° for 10 s, 1.5 mm
distance from body
Pin connections
Pin
1
2
3
6
7
8
9
Single
-V Input
+V Input
Remote on/off
+V Output
N.C.
N.C.
-V Output
Dual
-V Input
+V Input
Remote on/off
+V Output
Common
N.C.
-V Output
Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions for
use carefully before using!
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the
express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose
failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected
to result in significant injury to the user. Rev: 12.12 f
Page 3 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]