2W DC-DC Converter P2E-Series ● ● ● ● ● ● 9 Pin SIL Wide 4:1 input range Up to 1500 VDC isolation MTBF > 1.2 MHours. Continuous short circuit protection Remote control input Model selection guide Typ Single Output P2E243R3S P2E2405S P2E2412S P2E2415S P2E483R3S P2E4805S P2E4812S P2E4815S Dual Output P2E2405D P2E2412D P2E2415D P2E4805D P2E4812D P2E4815D Input voltage range VDC] Input Current no-load mA] Input current full-load [mA] Output voltage Output current [VDC] [mA] Load regulation @ load range Efficiency typ. @ full load [%] Filter inductance L1 [µH] Filter capacity C2 C-Load max. [µF] 9…36 9…36 9…36 9…36 18...75 18...75 18...75 18...75 10 10 10 10 5 5 5 5 92 103 100 98 46 53 50 50 3.3 5.0 12.0 15.0 3.3 5.0 12.0 15.0 0...500 0...400 0...165 0...135 0...500 0...400 0...165 0...135 1% 1% 0.5% 0.5% 1% 1% 0.5% 0.5% 10...100% 10...100% 0...100% 0...100% 10...100% 10...100% 0...100% 0...100% 75 81 84 85 75 80 84 84 6.8 6.8 6.8 6.8 68 68 68 68 4.7µF 4.7µF 4.7µF 4.7µF 1µF 1µF 1µF 1µF X7R X7R X7R X7R X7R X7R X7R X7R 2200 1000 160 100 2200 1000 160 100 9…36 9…36 9…36 18...75 18...75 18...75 10 10 10 5 5 5 103 101 102 53 52 50 ±5.0 ±12.0 ±15.0 ±5.0 ±12.0 ±15.0 ±0...200 ±0...85 ±0...65 ±0...200 ±0...85 ±0...65 1% 1% 1% 1% 1% 1% 10...100% 10...100% 10...100% 10...100% 10...100% 10...100% 81 83 82 80 81 84 6.8 6.8 6.8 68 68 68 4.7µF 4.7µF 4.7µF 1µF 1µF 1µF X7R X7R X7R X7R X7R X7R 2 x 470 2 x 100 2 x 47 2 x 470 2 x 100 2 x 47 Page 1 of 3 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 2W DC-DC Converter P2E-Series EFT & Surge (for EN61000-4-4 and EN61000-4-5) The external filter capacitor C1 is required if the module has to meet EN61000-4-4 class B and EN61000-4-5 class B. EMI Filter (for EN55022 class A) Input filter components (C2, L1) are used to help meet conducted emissions requirement for the module. These components should be mounted as close as possible to the module; and all leads should be minimized to decrease radiated noise. L1 see table Coiltronics SD3118 series + Vin C1 + C2 220µF 100V See KR series table NipponChemicon 2 1k 6 3 + Vout max. C-Load see table Rem. ctrl voltage “Off” 2.7..15V “On” 0..0.6V or open input 1 9 - Vin - Vout Efficiency versus output current Page 2 of 3 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 2W DC-DC Converter P2E-Series Specifications Input Absolute max. voltage for 100 ms Input current at standby mode Star up time (with resistive load) Filter Remote on/off controll Isolation: Rated voltage for 60 s, input / output (Tested for 3 s) Resistance Capacitance Output Voltage accuracy Ripple and noise (at 20 MHz BW) Short circuit protection Short circuit restart Line voltage regulation Dual output cross regulation Temperature coefficient Transient recovery time Transient response deviation General Switching frequency Safety standard in accordance with 24 V type –0.7..50 VDC 48 V type –0.7..100 VDC 5 mA max. 10ms, typ. Capacitors on: open or 0…0.6V off: 2.7…15 VDC 1500 VDC 9 10 Ω 500 pF, typ. ±1% 50 mVp-p, max. Continuous Automatic ± 0.5 % ±5% ± 0.02 % / °C 300µs, typ. ± 3 %, typ. EMI (see circuit diagram page 1) Conducted emissions Radiated emissions ESD RS EFT Surge CS PFMF Environmental Operating temperatur (ambient) Case temperature Storage temperature Derating Humidity Cooling Physical Dimensions SIP8 Weight Case material standard version Potting material Pin soldering temperature 250 kHz IEC60950 Dimensions EN55022 class A EN55022 class A IEC61000-4-2 perf. criteria B IEC61000-4-3 perf. criteria A IEC61000-4-4 perf. criteria B IEC61000-4-5 perf. criteria B IEC61000-4-6 perf. criteria A IEC61000-4-8 perf. criteria A -40 °C to +85°C (see derating curve) 100 °C, max. -40 °C ... +125 °C See curve Up to 95 %, non-condensing Free-air convection 26 x 9.3 x 12,5 mm 6.5 g non-conductive black plastic, UL94-V0 Epoxy UL94-V0 260 C° for 10 s, 1.5 mm distance from body Pin connections Pin 1 2 3 6 7 8 9 Single -V Input +V Input Remote on/off +V Output N.C. N.C. -V Output Dual -V Input +V Input Remote on/off +V Output Common N.C. -V Output Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions for use carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 12.12 f Page 3 of 3 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]