Download

6W DC-DC Converter P6C-Series
●
●
●
●
●
Wide 2:1 input range
Low input voltage range 4.5 to 9 V
Up to 3500 VDC isolation
MTBF >1.12 Mio. hours
Continuous short circuit protection
Model guide
Type
Single output
P6C053R3S
P6C0505S
P6C0512S
P6C0515S
Dual output
P6C053R3D
P6C0505D
P6C0512D
P6C0515D
Input voltage
range
Input current
No load
Full load
Output voltage Output current
min. / max.
[VDC]
[mA]
[mA]
[VDC]
4.5...9
4.5...9
4.5...9
4.5...9
25
25
30
30
1292
1600
1490
1472
3.3
5.0
12.0
15.0
4.5...9
4.5...9
4.5...9
4.5...9
25
25
35
40
1658
1548
996
997
±3.3
±5.0
±12.0
±15.0
[%]
Capacitor load
max.
(see note 3)
[mA]
0…1400
0…1200
0…500
0…400
73
76
82
82
1000
1000
330
220
0…±910
0…±600
0…±250
0…±200
75
79
83
83
2 x 680
2 x 330
2 x 100
2 x 47
[mA]
Efficiency typ.
Suffix: “H” for 3.5 kVDC isolation voltage
Specifications
Input
Filter
Reflected ripple current
Start up time
Isolation:
Rated voltage (1 minute,
input to output)
Resistance
Capacitance
Output
Voltage tolerance
Dual outputs cross regulation
(see note 1)
Ripple and noise at 20 MHz
BW (see note 2)
Short circuit protection
Current limiting
Line voltage regulation
Load voltage regulation
LC circuit
35 mAp-p, typ.
20 ms, typ.
1500 VDC, Standard
3500 VDC, Suffix “H”
9
10 Ω
500 pF, typ.
± 1 %, max.
± 2 %, max. @ 3.3 V types
± 5 %, max.
60 mVp-p, max.
Continuous, automatic restart
~150 %, typ. of full load
± 0.5 %, max.
± 0.5 %, max.
± 1.5 %, max.@ 3.3 V types
Temperature coefficient
± 0.02 % / °C
Transient recovery time (see note 4) 250 µs, typ.
Transient response deviation 3 %, max.
(see note 4)
General
Switching frequency
270 kHz, typ.
1.21 Mio. hours
Reliability calculated MTBF
(MIL-HDBK-217F)
Safety in accordance with
IEC 60950-1
EMC
Radiated emmisions
Conducted emmisions
(see note 5)
ESD
RS
EFT ( see note 6)
Surge ( see note 6)
CS
PFMF
Environmental
Operating temperatur
(ambient)
Case temperature
Storage temperature
Derating
Humidity
Cooling
Physical
Dimensions
Weight
Potting material
Case material
Absolute maximum ratings
Input voltage 0.1 s max.
Lead soldering Temperature
EN55022 ClassA
EN55022 ClassA
IEC 61000-4-2 perf. crit. A
IEC 61000-4-3 perf. crit. A
IEC 61000-4-4 perf. crit. A
IEC 61000-4-5 perf. crit. A
IEC 61000-4-6 perf. crit. A
IEC 61000-4-8 perf. crit. A
-40 °C to +85 °C
100 °C, max.
-40 °C to +125 °C
None required
Up to 95%, non-condensing
Free air convection
31.75 x 20.32 x 10.16 mm
17 g metal, standard
Epoxy (UL94-V-0 rated)
Nickel coated copper
-0.7 VDC …15 VDC
260 °C for 10 s, distance from
package 1.5 mm
Page 1 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
6W DC-DC Converter P6C-Series
Note:
1. If one output load is 25 % to 100 % and the other output load is 100 %, than the output voltage drift rate will be max. ± 5 %.
2. Ripple and noise measured with a 1 µF ceramic capacitor.
3. Tested by nominal input voltage and constant resistor load.
4. Tested by normal Vin and 25 % load step change (75 % - 50 % - 25 % of Io).
5. It’s recommended to add C1 330 µF, C2 470 µF, L 1.8 µH on the input end to achieve EN55022 conducted Class A.
6. An external filter capacitor is required if the module has to meet IEC61000-4-4 and IEC61000-4-5. C1 330 µF, C2 470 µF,
L 1.8 µH
Measure circuit for input reflected ripple current
Measure point
for current probe
+Vin
+Vout
Lin 12 µH
DC
Resistive
load 100 %
Cin 100 µF
ESR <1Ω
@ 100kHz
DC
-Vin
-Vout
Input reflected ripple current is measured after the input inductor Lin and the source capacitor Cin at nominal input and full load.
Output Ripple & Noise Measurement Test
+Vout
DC/DC-Converter
Resistive
load
Cout
1 µF
Measure points
for oscilloscope
-Vout
The oscilloscope measurement bandwidth must be better than 20 MHz.
EMI Filter
+Vin
+Vout
L 1.8 µH
DC
Load
C1
330 µF
-Vin
C2
470 µF
DC
-Vout
Input filter components C1, C2, L are used to help meet the conducted emissions requirements of the module. These components
should be mounted as close as possible to the module. All pins should be minimized to decrease radiated noise.
Page 2 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
6W DC-DC Converter P6C-Series
Dimensions
Pin connections
Pin
2
3
9
11
14
16
22
23
Single
-V Input
-V Input
Omitted
N.C.
+V Output
-V Output
+V Input
+V Input
Dual
-V Input
-V Input
Common
-V Output
+V Output
Common
+V Input
+V Input
PHI-CON is a trademark of HY-LINE power components.
Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions
carefully before using!
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without
the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and
whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably
expected to result in significant injury to the user. Rev: 02.14 f
Page 3 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]