6W DC-DC Converter P6C-Series ● ● ● ● ● Wide 2:1 input range Low input voltage range 4.5 to 9 V Up to 3500 VDC isolation MTBF >1.12 Mio. hours Continuous short circuit protection Model guide Type Single output P6C053R3S P6C0505S P6C0512S P6C0515S Dual output P6C053R3D P6C0505D P6C0512D P6C0515D Input voltage range Input current No load Full load Output voltage Output current min. / max. [VDC] [mA] [mA] [VDC] 4.5...9 4.5...9 4.5...9 4.5...9 25 25 30 30 1292 1600 1490 1472 3.3 5.0 12.0 15.0 4.5...9 4.5...9 4.5...9 4.5...9 25 25 35 40 1658 1548 996 997 ±3.3 ±5.0 ±12.0 ±15.0 [%] Capacitor load max. (see note 3) [mA] 0…1400 0…1200 0…500 0…400 73 76 82 82 1000 1000 330 220 0…±910 0…±600 0…±250 0…±200 75 79 83 83 2 x 680 2 x 330 2 x 100 2 x 47 [mA] Efficiency typ. Suffix: “H” for 3.5 kVDC isolation voltage Specifications Input Filter Reflected ripple current Start up time Isolation: Rated voltage (1 minute, input to output) Resistance Capacitance Output Voltage tolerance Dual outputs cross regulation (see note 1) Ripple and noise at 20 MHz BW (see note 2) Short circuit protection Current limiting Line voltage regulation Load voltage regulation LC circuit 35 mAp-p, typ. 20 ms, typ. 1500 VDC, Standard 3500 VDC, Suffix “H” 9 10 Ω 500 pF, typ. ± 1 %, max. ± 2 %, max. @ 3.3 V types ± 5 %, max. 60 mVp-p, max. Continuous, automatic restart ~150 %, typ. of full load ± 0.5 %, max. ± 0.5 %, max. ± 1.5 %, max.@ 3.3 V types Temperature coefficient ± 0.02 % / °C Transient recovery time (see note 4) 250 µs, typ. Transient response deviation 3 %, max. (see note 4) General Switching frequency 270 kHz, typ. 1.21 Mio. hours Reliability calculated MTBF (MIL-HDBK-217F) Safety in accordance with IEC 60950-1 EMC Radiated emmisions Conducted emmisions (see note 5) ESD RS EFT ( see note 6) Surge ( see note 6) CS PFMF Environmental Operating temperatur (ambient) Case temperature Storage temperature Derating Humidity Cooling Physical Dimensions Weight Potting material Case material Absolute maximum ratings Input voltage 0.1 s max. Lead soldering Temperature EN55022 ClassA EN55022 ClassA IEC 61000-4-2 perf. crit. A IEC 61000-4-3 perf. crit. A IEC 61000-4-4 perf. crit. A IEC 61000-4-5 perf. crit. A IEC 61000-4-6 perf. crit. A IEC 61000-4-8 perf. crit. A -40 °C to +85 °C 100 °C, max. -40 °C to +125 °C None required Up to 95%, non-condensing Free air convection 31.75 x 20.32 x 10.16 mm 17 g metal, standard Epoxy (UL94-V-0 rated) Nickel coated copper -0.7 VDC …15 VDC 260 °C for 10 s, distance from package 1.5 mm Page 1 of 3 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 6W DC-DC Converter P6C-Series Note: 1. If one output load is 25 % to 100 % and the other output load is 100 %, than the output voltage drift rate will be max. ± 5 %. 2. Ripple and noise measured with a 1 µF ceramic capacitor. 3. Tested by nominal input voltage and constant resistor load. 4. Tested by normal Vin and 25 % load step change (75 % - 50 % - 25 % of Io). 5. It’s recommended to add C1 330 µF, C2 470 µF, L 1.8 µH on the input end to achieve EN55022 conducted Class A. 6. An external filter capacitor is required if the module has to meet IEC61000-4-4 and IEC61000-4-5. C1 330 µF, C2 470 µF, L 1.8 µH Measure circuit for input reflected ripple current Measure point for current probe +Vin +Vout Lin 12 µH DC Resistive load 100 % Cin 100 µF ESR <1Ω @ 100kHz DC -Vin -Vout Input reflected ripple current is measured after the input inductor Lin and the source capacitor Cin at nominal input and full load. Output Ripple & Noise Measurement Test +Vout DC/DC-Converter Resistive load Cout 1 µF Measure points for oscilloscope -Vout The oscilloscope measurement bandwidth must be better than 20 MHz. EMI Filter +Vin +Vout L 1.8 µH DC Load C1 330 µF -Vin C2 470 µF DC -Vout Input filter components C1, C2, L are used to help meet the conducted emissions requirements of the module. These components should be mounted as close as possible to the module. All pins should be minimized to decrease radiated noise. Page 2 of 3 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 6W DC-DC Converter P6C-Series Dimensions Pin connections Pin 2 3 9 11 14 16 22 23 Single -V Input -V Input Omitted N.C. +V Output -V Output +V Input +V Input Dual -V Input -V Input Common -V Output +V Output Common +V Input +V Input PHI-CON is a trademark of HY-LINE power components. Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 02.14 f Page 3 of 3 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]