3W DC-DC Converter P3G-Series ● ● ● ● ● ● 9 Pin SIL Wide 4:1 input range Up to 1500 VDC isolation MTBF > 1.2 Mio. hours Continuous short circuit protection Remote control input Model selection guide Type Single Output P3G243R3S P3G2405S P3G2412S P3G2415S P3G483R3S P3G4805S P3G4812S P3G4815S Dual Output P3G2405D P3G2412D P3G2415D P3G4805D P3G4812D P3G4815D Input voltage range VDC] Input Current no-load mA] Input current full-load [mA] Output voltage Output current [VDC] [mA] Load regulation Output @ load Voltage drift range [%] [%] 9…36 9…36 9…36 9…36 18...75 18...75 18...75 18...75 10 10 10 10 5 5 5 5 125 153 149 148 65 78 75 75 3.3 5.0 12.0 15.0 3.3 5.0 12.0 15.0 0...700 0...600 0...250 0...200 0...700 0...600 0...250 0...200 1 1 0.5 0.5 1 1 0.5 0.5 9…36 9…36 9…36 18...75 18...75 18...75 10 10 10 5 5 5 155 149 149 78 75 76 ±5.0 ±12.0 ±15.0 ±5.0 ±12.0 ±15.0 ±0...300 ±0...125 ±0...100 ±0...300 ±0...125 ±0...100 1 1 1 1 1 1 Efficiency typ. @ full load [%] Filter inductance L1 [µH] Filter capacitor C2 (type X7R) [µF] C-Load max. [µF] 10...100 10...100 0...100 0...100 10...100 10...100 0...100 0...100 77 82 84 85 75 81 84 84 6.8 6.8 6.8 6.8 68 68 68 68 4.7 4.7 4.7 4.7 1 1 1 1 2200 1000 160 100 2200 1000 160 100 10...100 10...100 10...100 10...100 10...100 10...100 81 84 84 81 84 83 6.8 6.8 6.8 68 68 68 4.7 4.7 4.7 1 1 1 2 x 470 2 x 100 2 x 47 2 x 470 2 x 100 2 x 47 Page 1 of 3 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 3W DC-DC Converter P3G-Series EFT & Surge (for EN61000-4-4 and EN61000-4-5) The external filter capacitor C1 is required if the module has to meet EN61000-4-4 class B and EN61000-4-5 class B. EMI Filter (for EN55022 class A) Input filter components (C2, L1) are used to help meet conducted emissions requirement for the module. These components should be mounted as close as possible to the module; and all leads should be minimized to decrease radiated noise. L1 see table Coiltronics SD3118 series + Vin C1 + C2 220µF 100V See KR series table NipponChemicon 2 1k 6 3 + Vout max. C-Load see table Rem. ctrl voltage “Off” 2.7..15 V “On” 0..0.6 V or open input 1 9 - Vin - Vout Efficiency versus output current Page 2 of 3 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 3W DC-DC Converter P3G-Series Specifications Input Absolute max. voltage for 100 ms Input current at standby mode Start up time (with resistive load) Filter Remote on/off controll Isolation: Rated voltage for 60 s, input / output (Tested for 3 s) Resistance Capacitance Output Voltage accuracy Ripple and noise (at 20 MHz BW) Short circuit protection Short circuit restart Line voltage regulation Dual output cross regulation Temperature coefficient Transient recovery time Transient response deviation General Switching frequency Safety standard in accordance with 24 V type –0.7..50 VDC 48 V type –0.7..100 VDC 5 mA max. 10 ms, typ. Capacitors on: open or 0…0.6 V off: 2.7…15 VDC 1500 VDC 9 10 Ω 500 pF, typ. ±1% 50 mVp-p, max. Continuous Automatic ± 0.5 % ±5 % ± 0.02 % / °C 300 µs, typ. ± 3 %, typ. EMI (see circuit diagram page 1) Conducted emissions Radiated emissions ESD RS EFT Surge CS PFMF Environmental Operating temperatur (ambient) Case temperature Storage temperature Derating Humidity Cooling Physical Dimensions SIP8 Weight Case material standard version Potting material Pin soldering temperature 250 kHz IEC60950 Dimensions EN55022 class A EN55022 class A IEC61000-4-2 perf. criteria B IEC61000-4-3 perf. criteria A IEC61000-4-4 perf. criteria B IEC61000-4-5 perf. criteria B IEC61000-4-6 perf. criteria A IEC61000-4-8 perf. criteria A -40 °C to +85 °C (see SOA diagramm) 100 °C, max. -40 °C ... +125 °C See curve Up to 95 %, non-condensing Free-air convection 26 x 9.3 x 12.5 mm 6.5 g non-conductive black plastic, UL94-V0 Epoxy UL94-V0 260 C° for 10 s, 1.5 mm distance from body Pin connections Pin 1 2 3 6 7 8 9 Single -V Input +V Input Remote on/off +V Output N.C. N.C. -V Output Dual -V Input +V Input Remote on/off +V Output Common N.C. -V Output Only for professional use by professionals! Not for resale or distribution to the general public in any way! Read the instructions for use carefully before using! Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 12.13 f Page 3 of 3 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]