20W DC-DC Converter P20G-Series Preliminary ● ● ● ● ● ● ● ● ● ● ● Wide 2:1 Input Range MTBF >560 kHours 1600 VDC Isolation No Minimum Load Required Continuous Short Circuit Protection Over Current Protection Over Voltage Protection Efficiency up to 90% Wide Operation Temperature Range -40...75°C On / Off Remote Control Input Soft Start Model selection guide Typ Single output P20G123R3S P20G1205S P20G1212S P20G1215S P20G243R3S P20G2405S P20G2412S P20G2415S P20G483R3S P20G4805S P20G4812S P20G4815S Dual output P20G1212D P20G1215D P20G2412D P20G2415D P20G4812D P20G4815D Input voltage range [VDC] Input current no load [mA] 9...18 9...18 9...18 9...18 18...36 18...36 18...36 18...36 36...72 36...72 36...72 36...72 9...18 9...18 18...36 18...36 36...72 36...72 Output voltage Output current range [mA] Efficiency typ. Capacitor Load [%] [µF] full load [mA] [VDC] 60 60 30 30 35 35 25 25 25 25 15 15 1440 1850 1875 1875 720 935 935 935 360 470 470 465 3.3 5.0 12.0 15.0 3.3 5.0 12.0 15.0 3.3 5.0 12.0 15.0 0...4500 0...4000 0...1670 0...1330 0...4500 0...4000 0...1670 0...1330 0...4500 0...4000 0...1670 0...1330 86 90 89 89 86 89 89 89 86 89 89 90 6800 4700 680 680 6800 4700 680 680 6800 4700 680 680 30 30 30 30 20 20 1870 1870 940 940 470 470 ±12.0 ±15.0 ±12.0 ±15.0 ±12.0 ±15.0 0...±833 0...±667 0...±833 0...±667 0...±833 0...±667 89 89 89 89 89 89 2 x 220 2 x 100 2 x 220 2 x 100 2 x 220 2 x 100 Page 1 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 20W DC-DC Converter P20G-Series Specifications Input Filter Start up time with R-load Remote CTRL on/off, Pin3 Pi Network 30 ms typ. On: 3...12 V or open input Off: 0...1.2 V Standby current 5 mA typ Under voltage shut down 12V types lock on 8.6 V, lock off 7.9 V 24V types lock on 17.8 V, lock off 16 V 48V types lock on 33.5 V, lock off 30.5 V Output Voltage accuracy Voltage trim range (only single output type) Temperature coefficient Ripple and noise (at 20 MHz BW) Short circuit protection Over load protection Over voltage protection 3.3 V out type 5 V & ±5 V out type 12 V & ±12 V out type 15 V & ±15 V out type Line voltage regulation Load regulation 0...100% load Cross balance (dual outputs) Transient recovery time Transient response drift @ 75%...50%...25% load ± 1 %, max. ± 10 % ± 0.02% / °C 100 mVp-p, max. Indefinite (hiccup), Automatic restart 150 % typ. off full load Z-diode clamping 3.9 V 6.2 V 15 V 18 V ± 0.5 %, max. single ± 0.5%, max. dual ± 1%, max. @ balanced load ± 5 % @ 75 % load difference 250 µs typ. 3 %, max. General Switching frequency Safety Standard Reliability calculated MTBF MIL-HDBK-217 F) Isolation: Rated voltage Resistance Capacitance EMC Characteristics Radiated Emissions Conducted Emissions ESD RS EFT Surge CS PFMF Environmental Operating temperatur (ambient) Case temperature Storage temperature Derating Humidity Cooling Physical Dimensions Weight Case material Potting material Absolute maximum ratings Input voltage for 100 ms max. Vin 12 V types Vin 24 V types Vin 48 V types Pin soldering temperature 1.5mm distance from body 330 kHz, typ IEC 60950-1:2001 560 khrs 1600 VDC (flash tested for 3 s) 9 10 Ω 1000 pF, max. EN55022 class A EN55022 class A EN61000-4-2 Crit. B EN61000-4-3 Crit. A EN61000-4-4 Crit. B EN61000-4-5 Crit. B EN61000-4-6 Crit. A EN61000-4-8 Crit. A -40 °C to +75 °C 105 °C max. -40 °C to +125 °C see diagram Up to 95 % non-condensing Free-air convection 25.4 x 25.4 x 9.9 mm 18 g Nickel-coated copper Epoxy (UL94V-0 rated) -0,7…25 V -0,7…50 V. -0,7…100 V 260°C for 10sec Page 2 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 20W DC-DC Converter P20G-Series Efficiecy versus output current Dimensions Pin connections Pin 1 2 3 4 5 6 Single +V Input -V Input Remote control +V Output Trim Input -Vout Dual +V Input -V Input Remote control +V Output Common -Vout Page 3 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 20W DC-DC Converter P20G-Series 12µH, LD1-120-R Coiltronics + INPUT + OUTPUT V in + RemoteCTL-on + 220µF KR-Series Nippon Chemicon + V out + R-trim-down 2.2µF Remote CTRL DC/DC Converter + trim input C-Load see table RemoteCTL-off R-trim-up V in - V out - - INPUT - OUTPUT Table of trimming resistors Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 12.11 f Page 4 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]