Download

20W DC-DC Converter P20G-Series
Preliminary
●
●
●
●
●
●
●
●
●
●
●
Wide 2:1 Input Range
MTBF >560 kHours
1600 VDC Isolation
No Minimum Load Required
Continuous Short Circuit Protection
Over Current Protection
Over Voltage Protection
Efficiency up to 90%
Wide Operation Temperature Range -40...75°C
On / Off Remote Control Input
Soft Start
Model selection guide
Typ
Single output
P20G123R3S
P20G1205S
P20G1212S
P20G1215S
P20G243R3S
P20G2405S
P20G2412S
P20G2415S
P20G483R3S
P20G4805S
P20G4812S
P20G4815S
Dual output
P20G1212D
P20G1215D
P20G2412D
P20G2415D
P20G4812D
P20G4815D
Input
voltage
range
[VDC]
Input current
no load
[mA]
9...18
9...18
9...18
9...18
18...36
18...36
18...36
18...36
36...72
36...72
36...72
36...72
9...18
9...18
18...36
18...36
36...72
36...72
Output
voltage
Output
current
range
[mA]
Efficiency
typ.
Capacitor
Load
[%]
[µF]
full load
[mA]
[VDC]
60
60
30
30
35
35
25
25
25
25
15
15
1440
1850
1875
1875
720
935
935
935
360
470
470
465
3.3
5.0
12.0
15.0
3.3
5.0
12.0
15.0
3.3
5.0
12.0
15.0
0...4500
0...4000
0...1670
0...1330
0...4500
0...4000
0...1670
0...1330
0...4500
0...4000
0...1670
0...1330
86
90
89
89
86
89
89
89
86
89
89
90
6800
4700
680
680
6800
4700
680
680
6800
4700
680
680
30
30
30
30
20
20
1870
1870
940
940
470
470
±12.0
±15.0
±12.0
±15.0
±12.0
±15.0
0...±833
0...±667
0...±833
0...±667
0...±833
0...±667
89
89
89
89
89
89
2 x 220
2 x 100
2 x 220
2 x 100
2 x 220
2 x 100
Page 1 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
20W DC-DC Converter P20G-Series
Specifications
Input
Filter
Start up time with R-load
Remote CTRL on/off, Pin3
Pi Network
30 ms typ.
On: 3...12 V or open input
Off: 0...1.2 V
Standby current 5 mA typ
Under voltage shut down
12V types lock on 8.6 V, lock off 7.9 V
24V types lock on 17.8 V, lock off 16 V
48V types lock on 33.5 V, lock off 30.5 V
Output
Voltage accuracy
Voltage trim range
(only single output type)
Temperature coefficient
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Over load protection
Over voltage protection
3.3 V out type
5 V & ±5 V out type
12 V & ±12 V out type
15 V & ±15 V out type
Line voltage regulation
Load regulation
0...100% load
Cross balance
(dual outputs)
Transient recovery time
Transient response drift
@ 75%...50%...25% load
± 1 %, max.
± 10 %
± 0.02% / °C
100 mVp-p, max.
Indefinite (hiccup),
Automatic restart
150 % typ. off full load
Z-diode clamping
3.9 V
6.2 V
15 V
18 V
± 0.5 %, max.
single ± 0.5%, max.
dual ± 1%, max.
@ balanced load
± 5 % @ 75 % load difference
250 µs typ.
3 %, max.
General
Switching frequency
Safety Standard
Reliability calculated MTBF
MIL-HDBK-217 F)
Isolation:
Rated voltage
Resistance
Capacitance
EMC Characteristics
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
PFMF
Environmental
Operating temperatur
(ambient)
Case temperature
Storage temperature
Derating
Humidity
Cooling
Physical
Dimensions
Weight
Case material
Potting material
Absolute maximum ratings
Input voltage for 100 ms max.
Vin 12 V types
Vin 24 V types
Vin 48 V types
Pin soldering temperature
1.5mm distance from body
330 kHz, typ
IEC 60950-1:2001
560 khrs
1600 VDC (flash tested for 3 s)
9
10 Ω
1000 pF, max.
EN55022 class A
EN55022 class A
EN61000-4-2 Crit. B
EN61000-4-3 Crit. A
EN61000-4-4 Crit. B
EN61000-4-5 Crit. B
EN61000-4-6 Crit. A
EN61000-4-8 Crit. A
-40 °C to +75 °C
105 °C max.
-40 °C to +125 °C
see diagram
Up to 95 %
non-condensing
Free-air convection
25.4 x 25.4 x 9.9 mm
18 g
Nickel-coated copper
Epoxy (UL94V-0 rated)
-0,7…25 V
-0,7…50 V.
-0,7…100 V
260°C for 10sec
Page 2 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
20W DC-DC Converter P20G-Series
Efficiecy versus output current
Dimensions
Pin connections
Pin
1
2
3
4
5
6
Single
+V Input
-V Input
Remote control
+V Output
Trim Input
-Vout
Dual
+V Input
-V Input
Remote control
+V Output
Common
-Vout
Page 3 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
20W DC-DC Converter P20G-Series
12µH, LD1-120-R
Coiltronics
+ INPUT
+ OUTPUT
V in +
RemoteCTL-on
+
220µF
KR-Series
Nippon
Chemicon
+
V out +
R-trim-down
2.2µF
Remote
CTRL
DC/DC Converter
+
trim
input
C-Load
see table
RemoteCTL-off
R-trim-up
V in -
V out -
- INPUT
- OUTPUT
Table of trimming resistors
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the
express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose
failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected
to result in significant injury to the user. Rev: 12.11 f
Page 4 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]