20W DC-DC Converter P20F-Series ● ● ● ● ● ● ● ● ● ● ● Wide 4:1 Input Range MTBF >560 kHours 1600 VDC Isolation No Minimum Load Required Continuous Short Circuit Protection Over Current Protection Over Voltage Protection Efficiency up to 90% Wide Operation Temperature Range -40...75°C On / Off Remote Control Input Soft Start Model selection guide Typ Single output P20F243R3S P20F2405S P20F2412S P20F2415S P20F483R3S P20F4805S P20F4812S P20F4815S Dual output P20F2412D P20F2415D P20F4812D P20F4815D Input nominal voltage [VDC] Input current Output voltage Output current Efficiency typ. Capacitor Load no load [mA] full load [mA] [VDC] [mA] [%] [µF] 9...36 9...36 9...36 9...36 18...75 18...75 18...75 18...75 50 50 22 22 30 30 15 15 720 940 940 940 310 470 470 465 3.3 5.0 12.0 15.0 3.3 5.0 12.0 15.0 4500 4000 1670 1330 4500 4000 1670 1330 86 89 89 89 86 89 89 90 10000 5000 850 700 10000 5000 850 700 9...36 9...36 18...75 18...75 25 25 15 15 940 940 470 470 ±12.0 ±15.0 ±12.0 ±15.0 ±833 ±667 ±833 ±667 89 89 89 89 2 x 470 2 x 330 2 x 470 2 x 330 Page 1 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 20W DC-DC Converter P20F-Series Specifications Input Filter Start up time with R-load Remote CTRL on/off, Pin 3 Pi Network 30 ms typ. On: 3...12 V or open input Off: 0...1.2 V Standby current 5 mA typ Under voltage shut down 24 V types lock on 8.6 V, lock out 7.9 V 48 V types lock on 17.8 V, lock out 16 V Reflected input ripple current 30 mAp-p (with input circuit, see below) Output Voltage accuracy ± 1 %, max. Voltage trim range ± 10 % ±5% Cross regulation (dual outputs) Temperature coefficient ± 0.02% / °C 100 mVp-p, max. Ripple and noise (at 20 MHz BW) Short circuit protection Indefinite (hiccup), Automatic restart Over load protection 150 % of Iout max. Over voltage protection Z-diode clamping 3.3 V out type 3.9 V 5 V & ±5 V out type 6.2 V 12 V & ±12 V out type 15 V 15 V & ±15 V out type 18 V Line voltage regulation Load regulation 0...100% load Cross regulation @ dual output Transient recovery time ± 0.5 %, max. single ± 0.5 %, max. dual ± 1 %, max. (with balanced load) ±5% 250 µs typ. General Switching frequency Safety Standard Isolation: Rated voltage (for 60 s) Resistance Capacitance EMC Characteristics Radiated Emissions Conducted Emissions ESD RS EFT Surge CS PFMF Environmental Operating temperatur (ambient) Derating Case temperature Storage temperature Humidity Cooling Physical Dimensions Weight Case material Potting material Absolute maximum ratings Input voltage Vin 24 V types Vin 48 V types Pin soldering temperature 1.5 mm distance from body 330 kHz, typ IEC 60950-1 1600 VDC (flash tested for 3s) 9 10 Ω 1000 pF, max. EN55022 class A EN55022 class A EN61000-4-2 Crit. A EN61000-4-3 Crit. A EN61000-4-4 Crit. A EN61000-4-5 Crit. A EN61000-4-6 Crit. A EN61000-4-8 Crit. A -40 °C to +75 °C with derating! see diagram 105 °C max. -40 °C to +125 °C Up to 95 %, non-condensing Free-air convection 25.4 x 25.4 x 9.9 mm 18 g Nickel-coated copper Epoxy (UL94V-0 rated) -0,7…50 V for 100 ms max. -0,7…100 V for 100 ms max. 260 °C for 10 s Page 2 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 20W DC-DC Converter P20F-Series Dimensions Pin connections Pin 1 2 3 4 5 6 Single +V Input -V Input Remote control +V Output Trim Input -Vout Dual +V Input -V Input Remote control +V Output Common -Vout Page 3 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 20W DC-DC Converter P20F-Series 12µH, LD1-120-R Coiltronics + INPUT 1 RemoteCTL-on + 220µF KR-Series Nippon Chemicon + 4 + OUTPUT R-trim-down 2.2µF 3 DC/DC Converter + 5 C-Load see table RemoteCTL-off R-trim-up 2 6 - INPUT - OUTPUT Table of trimming resistors Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 12.11 f Page 4 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]