Download

20W DC-DC Converter P20F-Series
●
●
●
●
●
●
●
●
●
●
●
Wide 4:1 Input Range
MTBF >560 kHours
1600 VDC Isolation
No Minimum Load Required
Continuous Short Circuit Protection
Over Current Protection
Over Voltage Protection
Efficiency up to 90%
Wide Operation Temperature Range -40...75°C
On / Off Remote Control Input
Soft Start
Model selection guide
Typ
Single output
P20F243R3S
P20F2405S
P20F2412S
P20F2415S
P20F483R3S
P20F4805S
P20F4812S
P20F4815S
Dual output
P20F2412D
P20F2415D
P20F4812D
P20F4815D
Input
nominal
voltage
[VDC]
Input current
Output
voltage
Output
current
Efficiency
typ.
Capacitor
Load
no load
[mA]
full load
[mA]
[VDC]
[mA]
[%]
[µF]
9...36
9...36
9...36
9...36
18...75
18...75
18...75
18...75
50
50
22
22
30
30
15
15
720
940
940
940
310
470
470
465
3.3
5.0
12.0
15.0
3.3
5.0
12.0
15.0
4500
4000
1670
1330
4500
4000
1670
1330
86
89
89
89
86
89
89
90
10000
5000
850
700
10000
5000
850
700
9...36
9...36
18...75
18...75
25
25
15
15
940
940
470
470
±12.0
±15.0
±12.0
±15.0
±833
±667
±833
±667
89
89
89
89
2 x 470
2 x 330
2 x 470
2 x 330
Page 1 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
20W DC-DC Converter P20F-Series
Specifications
Input
Filter
Start up time with R-load
Remote CTRL on/off, Pin 3
Pi Network
30 ms typ.
On: 3...12 V or open input
Off: 0...1.2 V
Standby current 5 mA typ
Under voltage shut down
24 V types
lock on 8.6 V, lock out 7.9 V
48 V types
lock on 17.8 V, lock out 16 V
Reflected input ripple current 30 mAp-p (with input circuit,
see below)
Output
Voltage accuracy
± 1 %, max.
Voltage trim range
± 10 %
±5%
Cross regulation
(dual outputs)
Temperature coefficient
± 0.02% / °C
100 mVp-p, max.
Ripple and noise
(at 20 MHz BW)
Short circuit protection
Indefinite (hiccup),
Automatic restart
Over load protection
150 % of Iout max.
Over voltage protection
Z-diode clamping
3.3 V out type 3.9 V
5 V & ±5 V out type 6.2 V
12 V & ±12 V out type 15 V
15 V & ±15 V out type 18 V
Line voltage regulation
Load regulation
0...100% load
Cross regulation @ dual
output
Transient recovery time
± 0.5 %, max.
single ± 0.5 %, max.
dual ± 1 %, max.
(with balanced load)
±5%
250 µs typ.
General
Switching frequency
Safety Standard
Isolation:
Rated voltage (for 60 s)
Resistance
Capacitance
EMC Characteristics
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
PFMF
Environmental
Operating temperatur
(ambient)
Derating
Case temperature
Storage temperature
Humidity
Cooling
Physical
Dimensions
Weight
Case material
Potting material
Absolute maximum ratings
Input voltage
Vin 24 V types
Vin 48 V types
Pin soldering temperature
1.5 mm distance from body
330 kHz, typ
IEC 60950-1
1600 VDC (flash tested for 3s)
9
10 Ω
1000 pF, max.
EN55022 class A
EN55022 class A
EN61000-4-2 Crit. A
EN61000-4-3 Crit. A
EN61000-4-4 Crit. A
EN61000-4-5 Crit. A
EN61000-4-6 Crit. A
EN61000-4-8 Crit. A
-40 °C to +75 °C
with derating!
see diagram
105 °C max.
-40 °C to +125 °C
Up to 95 %,
non-condensing
Free-air convection
25.4 x 25.4 x 9.9 mm
18 g
Nickel-coated copper
Epoxy (UL94V-0 rated)
-0,7…50 V for 100 ms max.
-0,7…100 V for 100 ms max.
260 °C for 10 s
Page 2 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
20W DC-DC Converter P20F-Series
Dimensions
Pin connections
Pin
1
2
3
4
5
6
Single
+V Input
-V Input
Remote control
+V Output
Trim Input
-Vout
Dual
+V Input
-V Input
Remote control
+V Output
Common
-Vout
Page 3 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
20W DC-DC Converter P20F-Series
12µH, LD1-120-R
Coiltronics
+ INPUT
1
RemoteCTL-on
+
220µF
KR-Series
Nippon
Chemicon
+
4
+ OUTPUT
R-trim-down
2.2µF
3
DC/DC Converter
+
5
C-Load
see table
RemoteCTL-off
R-trim-up
2
6
- INPUT
- OUTPUT
Table of trimming resistors
Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the
express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose
failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected
to result in significant injury to the user. Rev: 12.11 f
Page 4 of 4
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]