15W DC-DC Converter P15F-Series ● ● ● ● ● ● ● ● ● ● ● ● Wide 4:1 Input Range MTBF >550 kHours 1600 VDC Isolation No Minimum Load Required Continuous Short Circuit Protection Over Current Protection Over Voltage Protection Efficiency up to 89% 15 mA no load Input Current Wide Operation Temperature Range -40...85°C On / Off Remote Control Input Soft Start Model selection guide Typ Single output P15F243R3S P15F2405S P15F2412S P15F2415S P15F483R3S P15F4805S P15F4812S P15F4815S Dual output P15F2405D P15F2412D P15F2415D P15F4805D P15F4812D P15F4815D Input nominal voltage [VDC] Input current Output voltage Output current Efficiency typ. Capacitor Load no load [mA] full load [mA] [VDC] [mA] [%] [µF] 9...36 9...36 9...36 9...36 18...72 18...72 18...72 18...72 15 15 15 15 10 10 10 10 650 730 750 710 330 370 380 360 3.3 5.0 12.0 15.0 3.3 5.0 12.0 15.0 4000 3000 1300 1000 4000 3000 1300 1000 86 87 88 89 84 86 87 88 1000 1000 330 220 1000 1000 330 220 9...36 9...36 9...36 18...72 18...72 18...72 15 15 15 10 10 10 750 720 710 380 360 360 ±5.0 ±12.0 ±15.0 ±5.0 ±12.0 ±15.0 ±1500 ±625 ±500 ±1500 ±625 ±500 85 88 89 84 87 88 2 x 470 2 x 220 2 x 100 2 x 470 2 x 220 2 x 100 Page 1 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 15W DC-DC Converter P15F-Series Specifications Input Filter Pi Network Start up time with R-load 20 ms typ. Remote CTRL on/off, Pin3 On: 3...12 V or open input Off: 0...1.2 V Standby current 5mA typ Under voltage shut down 24V types lock on 8.5V, lock out 7V 48V types lock on 17V, lock out 15V Output Voltage accuracy ± 1 %, max. Voltage trim range ± 10 % Voltage balance ±1% (dual outputs) Temperature coefficient ± 0.02% / °C 100 mVp-p, max. Ripple and noise (at 20 MHz BW) Short circuit protection Indefinite (hiccup), Automatic restart Over load protection 170 % of Iout max. Over voltage protection Z-diode clamping 3.3 V out type 3.9 V 5 V & ±5 V out type 6.2 V 12 V & ±12 V out type 15 V 15 V & ±15 V out type 18 V Line voltage regulation Load regulation 0...100% load Cross regulation @ dual output Transient recovery time Transient response drift @ 75%...50%...25% load ± 0.2 %, max. single ± 0.5%, max. dual ± 1%, max. ±5% 250 µs typ. 3 %, max. General Switching frequency Safety Standard Isolation: Rated voltage (for 60 s) Resistance Capacitance EMC Characteristics Radiated Emissions Conducted Emissions ESD RS EFT Surge CS PFMF Environmental Operating temperatur (ambient) Case temperature Storage temperature Derating Humidity Cooling Physical Dimensions Weight Case material Potting material Pin soldering temperature 1.5mm distance from body 370 kHz, typ IEC 60950-1:2001 1600 VDC (flash tested 1s) 109 Ω 1200 pF, max. EN55022 class A EN55022 class A EN61000-4-2 Crit. A EN61000-4-3 Crit. A EN61000-4-4 Crit. A EN61000-4-5 Crit. A EN61000-4-6 Crit. A EN61000-4-8 Crit. A -40 °C to +85 °C 105 °C max. -40 °C to +125 °C see diagram Up to 95 %, non-condensing Free-air convection 25.4 x 25.4 x 9.9 mm 18 g Nickel-coated copper Epoxy (UL94V-0 rated) 260°C for 10sec Page 2 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 15W DC-DC Converter P15F-Series Dimensions Pin connections Pin 1 2 3 4 5 6 Single +V Input -V Input Remote control +V Output Trim Input -Vout Dual +V Input -V Input Remote control +V Output Common -Vout Page 3 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected] 15W DC-DC Converter P15F-Series 12µH, LD1-120-R Coiltronics + INPUT 1 RemoteCTL-on + 220µF KR-Series Nippon Chemicon + 4 + OUTPUT R-trim-down 2.2µF 3 DC/DC Converter + 5 C-Load see table RemoteCTL-off R-trim-up 2 6 - INPUT - OUTPUT Table of trimming resistors Life Support Policy: HY-LINE does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Rev: 12.11 f Page 3 of 4 Deutschland: Inselkammerstraße 10 D-82008 Unterhaching Tel.: 089 614 503-10 E-Mail: [email protected] Schweiz: Gründenstrasse 82 CH-8247 Flurlingen Tel.: 052 647 42 00 E-Mail: [email protected]