Download

12W DC-DC Converter P12C-Series
●
●
●
●
●
●
●
●
Wide 2:1 Input Range
1600 VDC Isolation
MTBF >1 MHours
Continuous Short Circuit Protection
Efficiency up to 91%
15 mA no load Input Current
Soft Start
Wide Operation Temperature Range -40...85°C
Model selection guide
Typ
Single output
P12C122R5S
P12C123R3S
P12C1205S
P12C1212S
P12C1215S
P12C242R5S
P12C243R3S
P12C2405S
P12C2412S
P12C2415S
P12C482R5S
P12C483R3S
P12C4805S
P12C4812S
P12C4815S
Dual output
P12C1212D
P12C1215D
P12C2412D
P12C2415D
P12C4812D
P12C4815D
Input nominal
voltage
[VDC]
Input current
full load
[mA]
Output voltage
Output current
Efficiency typ.
[VDC]
[mA]
[%]
Capacitor
Load
[µF]
9...18
9...18
9...18
9...18
9...18
18...36
18...36
18...36
18...36
18...36
36...72
36...72
36...72
36...72
36...72
890
1145
1165
1150
1150
445
575
580
575
575
225
285
290
295
290
2.5
3.3
5.0
12.0
15.0
2.5
3.3
5.0
12.0
15.0
2.5
3.3
5.0
12.0
15.0
3500
3500
2400
1000
800
3500
3500
2400
1000
800
3500
3500
2400
1000
800
85
87
89
90
90
85
87
89
90
90
84
88
89
88
89
2000
2000
2000
430
300
2000
2000
2000
430
300
2000
2000
2000
430
300
9...18
9...18
18...36
18...36
36...72
36...72
1150
1135
575
562
295
290
±12.0
±15.0
±12.0
±15.0
±12.0
±15.0
±500
±400
±500
±400
±500
±400
90
91
90
91
88
89
2 x 200
2 x 120
2 x 200
2 x 120
2 x 200
2 x 120
Page 1 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
12W DC-DC Converter P12C-Series
Specifications
Input
Filter
Pi Network
Start up time with R-load
20 ms typ.
Remote CTRL on/off, Pin1 On: 3...12V or open input
Off: 0...1.2V
Standby current 5mA typ
Isolation:
Rated voltage (for 60 s)
1600 VDC (flash tested 3 s)
Resistance
109 Ω
Capacitance
1200 pF, typ.
Output
Voltage accuracy
± 1.2%, max.
Voltage balance
± 1%
(dual outputs)
Cross regulation @ dual outp.
± 5%
Temperature coefficient
± 0.02% / °C
Ripple and noise
85 mVp-p, max.
(at 20 MHz BW)
Short circuit protection
Indefinite (hiccup),
Automatic restart
Over current limiting
150% of Iout max.
Over voltage protection
2.5V , 3.3V out type 3.9V Z-diode clamping
5V out type 6.2V Z-diode clamping
(±) 12V out type (±)15V Z-diode clamping
(±) 15V out type (±)18V Z-diode clamping
Line voltage regulation
± 0.5%, max.
single ± 0.5%, max.
Load regulation
0...100% load
dual ± 1%, max.
Transient recovery time
250µs typ.
3%
Transient response drift
@ 75%...50%...25% load
General
Switching frequency
Safety Standard
EMC Characteristics
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
PFMF
Environmental
Operating temperatur
(ambient)
Case temperature
Storage temperature
Derating
Humidity
Cooling
Physical
Dimensions
Weight
Case material
Potting material
Pin soldering temperature
1.5mm distance from body
330 kHz
IEC 60950-1
EN55022 class A
EN55022 class A
EN61000-4-2 Crit. B
EN61000-4-3 Crit. A
EN61000-4-4 Crit. B
EN61000-4-5 Crit. B
EN61000-4-6 Crit. A
EN61000-4-8 Crit. A
-40 °C to +85 °C
100 °C max.
-40 °C to +125 °C
see diagram
Up to 95%,
non-condensing
Free-air convection
31.75 x 20.32 x 10.16 mm
18 g
Standard, nickel-coated
copper metal
Epoxy (UL94V-0 rated)
260°C for 10sec
12µH, LD1-120-R
Coiltronics
+ INPUT
22 / 23
14
+ OUTPUT
Remote ON
330µF KR-Series
Nippon Chemicon
1
DC/DC Converter
C-Load
see table
Remote OFF
2/3
16
- INPUT
- OUTPUT
Page 2 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
12W DC-DC Converter P12C-Series
Dimensions
Pin connections
Pin
1
2
3
9
11
14
16
22
23
Single
Remote contr.
-V Input
-V Input
Omitted
N.C.
+V Output
-V Output
+V Input
+V Input
Dual
Remote contr.
-V Input
-V Input
Common
-V Output
+V Output
Common
+V Input
+V Input
Life Support Policy: HY-LINE does not authorize the use of any of its products
for use in life support devices or systems without the express written approval
of an officer of the Company. Life support systems are devices which support or
sustain life, and whose failure to perform, when properly used in accordance
with instructions for use provided in the labeling, can be reasonably expected to
result in significant injury to the user. Rev: 12.09 f
Page 3 of 3
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00