20W DC-DC Converter P20Y-Series
●
●
●
●
●
●
●
●
●
20 W Output Power
4:1 Wide Input Voltage Range
Adjustable Output Voltage
Remote Control Input
International Safety Standard
Six-Sided Continuous Shield
High Efficiency up to 84%
Standard 2" x 1.6" x 0.4" Package
Fixed Switching Frequency
Model selection guide
Typ
Input
nominal
voltage
Single output
P20Y24S33W
P20Y24S05W
P20Y24S12W
P20Y24S15W
P20Y48S33W
P20Y48S05W
P20Y48S12W
P20Y48S15W
Dual output
P20Y24D05W
P20Y24D12W
P20Y24D15W
P20Y48D05W
P20Y48D12W
P20Y48D15W
Input
current
full-load
Output
voltage
Output
current
Efficiency
typ.
Capacitor
load max.
Output
ripple @
bandwide
20mHz
[mVp-p]
[VDC]
[mA]
[VDC]
[mA]
[%]
[uF]
9-36
9-36
9-36
9-36
18-75
18-75
18-75
18-75
764
1111
1082
1082
377
548
541
541
3.3
5
12
15
3.3
5
12
15
4000
4000
1670
1330
4000
4000
1670
1330
76
79
81
81
77
80
81
81
13000
6800
2200
755
13000
6800
2200
755
75
75
75
75
75
75
75
75
9-36
9-36
9-36
18-75
18-75
18-75
1111
1082
1068
556
527
521
±5
±12
±15
±5
±12
±15
±2000
±833
±666
±2000
±833
±666
79
81
82
79
83
84
2 x 3400
2 x 680
2 x 450
2 x 3400
2 x 680
2 x 450
100
100
100
100
100
100
Page 1 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]
20W DC-DC Converter P20Y-Series
Specifications
Input
Voltage range
Filter
Input surge voltage for
100mS max.
Start up time
Remote CTRL
P20Y: 9..36, 18..75VDC
π Pi type
24V type : 50 VDC max.
48V type : 100 VDC max.
20mS typ
On: open or 3.5..12 VDC
Off : 0...1.2 VDC
-20mA
-Input
Remote CTRL input current
Remote CTRL input reference
Output
Power
Voltage accuracy
20W max
Single & Dual
±2%
Auxiliary
±5%
±10%
Hiccup, automatics recovery
3.3V output: 3.9V, 5V output: 6.2V,
12V output: 15V, 15V output: 18V
Auxiliary
±5%
single: ± 0.5%,
dual: ±3%,
tiple3.3V/5V: ±2%, Auxiliary: 5%
± 0.02% / °C max.
10% to maintain the specified
regulation
Voltage adjustability
Short circuit protection
Over voltage protection
zener diode clamp
Line voltage regulation
Load voltage regulation
25%…100%
Temperature coefficient
Minimum load
General
Efficiency
Switching frequency
Transient response recovery time
Isolation voltage
Isolation Leakage current
Isolation Resistance
Isolation Capacitance
Case material
Base material
Potting material
MTBF
Bellcore TR-NWT-000332
Environmental
Operating temperature
Storage temperature
Maximum case temp.
Thermal impedance
Vibration
Humidity
Physical
Dimensions
Weight
Dimensions
50.8
2 x 1.6x 0.4 inches
50.8x40.6x10.2 mm
48 g
5.1
10.2
17.8
Bottom
view
10.2
-25 °C to +85 °C
(standard, derating)
-55 °C to +105 °C
+100 °C
Nature convection 10°C/W
with headsink
8.3°C/W
10..55Hz, 2G, 30min, X,Y, Z axis
5% to 95% RH
Derating
40.6
15.2
See table
300 kHz, typ.
@25% load change 500µs
1600 VDC
1 mA
9
10 Ω
300 pF, typ.
Nickel-coated copper
Non conductive black plastic
Epoxy (UL94-V0)
@Ta 40°C, 50% stress:
6
1.928x10 hrs
45.7
10.2
5.6
17.8
12.7
All dimensions in inches (mm)
Pin Pitch tolerance (0.35)
Pin connections
Output adjustment
PIN
1
2
4
5
6
7
8
Output can be externally trimmed
by using the method shown below.
( ) for dual output trim.
Single
Dual
+ Input
+ Input
- Input
- Input
Remote CTRL Remote CTRL
No Pin
+ Output
+ Output
Common
- Output
- Output
TRIM Input
TRIM Input
7(7)
TRIM UP
8(8)
TRIM DOWN
6(5)
Life Support Policy: HY-LINE does not
authorize the use of any of its products for
use in life support devices or systems
without the express written approval of an
officer of the Company. Life support systems are devices which support or sustain
life, and whose failure to perform, when
properly used in accordance with instructions for use provided in the labeling, can
be reasonably expected to result in significant injury to the user.
Rev: 5 / 2005 f
Page 2 of 2
Deutschland:
Inselkammerstraße 10
D-82008 Unterhaching
Tel.: 089 614 503-10
E-Mail: [email protected]
Schweiz:
Gründenstrasse 82
CH-8247 Flurlingen
Tel.: 052 647 42 00
E-Mail: [email protected]