 Description
 Features
 Absolute Maximum Ratings
 Recommended Operating Conditions
 Electrical Power Supply Characteristics
 Optical and Electrical Characteristics
 Drawing of transmitter and receiver modules
 DVI Pin Description/RS232 Pin Description
 Reliability Test of Modules
 Terminology
Headquarters
Opticis Co., Ltd
# 304, Byucksan Technopia
434-6 Sangdaewon-Dong, Chungwon-Ku
Sungnam City, Kyungki-Do, 462-120
South Korea
Tel: +82 (31) 737-8033
Fax: +82 (31) 707-8079
Email: [email protected]
www.opticis.com
Copyright © 2008, All rights reserved, Opticis Co., Ltd.
12, Aug. 2008
M5-2A2 (Ver. 1.5)
www.opticis.com
Digital Video/Audio and Serial I/O Extender
Description
The reality of gigabit high-speed digital graphic interconnections mandates products that maintain
front-of-screen video quality. Optical technology extends the ability to transmit digital graphic data
beyond the physical limits of copper wires by, i) providing pure signal integrity over long distances for
the optimum visual experience, ii) no EMI/RFI transmission or reception, iii) light weight, rugged
cabling and connectors, iv) very cost effective per foot/metre, v) low power consumption, and vi) plug
and go installation ease – no software requirements.
M5-2A2-TR offers integrated extension of digital video, audio and RS-232 interface up to 200m
(656ft) for HDMI and up to 2km (6,600 ft) for DVI. It maintains HD video signals up to WUXGA
(1920x1200) at 60Hz refresh rate for PC and 1080p for HDTV. It is compatible with full DDC2B and
HDCP. It supports connecting one of 3 different audio types in the transmitter; RCA, SPDIF (Optic) or
SPDIF (Coaxial) and outputting all 3 audio types. RS232 serial interface offers device-to-device and
device-to-controller connections to build up control system for A/V integration.
It is designed to multiplex and de-multiplex the DVI/HDMI video, digital/analog audio, Display Data
Channel (DDC) command interface, High Definition Copy Protection (HDCP) and serial protocol so as
to be linked over 4 LC fibers. It gives benefits of all-glass fiber transmission medium, data security,
long distance extension up to 2km, easy plug-and-go installation and no RFI/EMI effects. In addition, a
non-trivial feature is that both of Single and Multimode optical fibers are applicable.
The M5-2A2-TR consists of an Uplink (or transmitter; Tx) and a Downlink (or receiver; Rx), connected
by two duplex LC terminated single or multi-mode patch cords between them, which offers electrical
perfect isolation. Each link module is driven by +12V/3A DC power adaptor.
The shipping group is as follows;
1) One pair of the uplink and the downlink
2) Two +12V/3A power adaptors
3) User Manual
Copyright © 2008, All rights reserved, Opticis Co., Ltd.
-1-
12, Aug. 2008
M5-2A2 (Ver. 1.5)
www.opticis.com
Feature

Extends DVI, Audio and RS232 up to 2 km if using smart DDC ready button on front panel.

Extends HDMI, Audio and RS232 up to 200 m with DDC/HDCP.

Audio interface: Selectable RCA, SPDIF (Optic) or SPDIF (Coaxial).

The electrical S/PDIF and Optical S/PDIF port can support only D-PCM or PCM audio format
for stereo sound.
Ex) In case of Samsung (Bluray, SV-D507HD) DVD player
-. Audio Digital out: PCM
In case of Sony (DVP-NS92V, DVP-NS975V) DVD player
-. Audio Digital out: D-PCM

Serial control data: RS232 with 9 pin D-sub female connector in the transmitter and male
connector in the receiver.

Video data: WUXGA (1920X1200), 24bit color and 60Hz refresh rate for DVI and 1080p for HDMI.

Interconnection between transmitter and receiver: Two(2) Duplex LC patch cords of single or multi
mode fiber.

Applicable of both single and multi-mode fiber.

+12 V DC power supply to each module.

Complies with DDC2B/HDCP.

No software to install; just plug and go.

Data security with negligible RFI/EMI emissions
Applications

Digital display system integration for medical, military, aerospace, factory automation, and traffic
control platforms.

Digital FPD, PDP and projector installation in conference rooms, auditoriums and for kiosk
systems

LED signboards for large scale information display and stadiums
Copyright © 2008, All rights reserved, Opticis Co., Ltd.
-2-
12, Aug. 2008
M5-2A2 (Ver. 1.5)
www.opticis.com
Absolute Maximum Ratings
Parameter
Storage Temperature
Supply Voltage
Transmitter Differential Input Voltage
Relative Humidity
Lead Soldering Temperature & Time
Symbol
Tstg
VCC
Vd
RH
-
Minimum
- 10
10
10
-
Maximum
+ 70
16
1
85
Units
C
V
V
%
260C, 10 sec
Recommended Operating Conditions
Parameter
Ambient Operating Temperature
Data Output Load
Power Supply Rejection (Note1)
Supply Voltage
Symbol
TA
RLD
PSR
VCC
Minimum
0
+ 11.4
Typical
50
50
+ 12.0
Maximum
+ 50
+ 12.6
Units
C
Ω
mVp-p
V
Note1. Tested with a 50mVp-p sinusoidal signal in the frequency range from 500 Hz to 500 MHz on the V CC supply with
the recommended power supply filter in place. Typically less than a 0.25 dB change in sensitivity is experienced.
Electrical Power Supply Characteristics
(TA = 0 C to +50 C, unless otherwise noted)
Parameter
Supply Voltage
Supply Current
Power Dissipation
TX
RX
TX
RX
Symbol
VCC
ITCC
IRCC
PTX
PRX
Minimum
11.4
350
370
3.99
4.22
Copyright © 2008, All rights reserved, Opticis Co., Ltd.
-3-
Typical
12
380
390
4.56
4.68
Maximum
12.6
400
420
5.04
5.3
Units
V
mA
mA
W
W
12, Aug. 2008
M5-2A2 (Ver. 1.5)
www.opticis.com
Optical & Electrical Characteristics
Parameters
Symbol
1310 Tx
1550 Rx
Data Bit Rate
1550 Tx
1310 Rx
Fiber Length
9µum core SMF
(Top = 25℃)
Condition
Unit
PRBS 2 -1,NRZ
23
Mbps
23
Mbps
PRBS 2 -1,NRZ
Min.
Typ.
Max.
Remark
1250
155.52
155.52
1250
-10
10 BER,
155Mbps/1.25Gbps
km
2
dBm
-11
-15
dB
5
CW, @ POUT
nm
1270
1500
RMS Width
TRANSMITTER
Average Power Output
POUT
Extinction Ratio
ER
Center Wavelength
C
Spectral Width
RIN
Optical Rise/Fall Time
tr/tf
-9
-10
-7
-8
1310
1550
nm
1355
1600
4.0
dB/Hz
-120
nsec
0.26
2.0
If=IBIAS + Imod/2
20 – 80%
@1.31 µm
@1.55 µm
RECEIVER
Sensitivity
(Average Input Power)
1310
Wavelength
1550
Receiver Overload
Signal Detect Threshold
Decreasing light input
Increasing light input
PIN,MIN
23
PRBS 2 -1,
-10
10 BER
dBm
nm
1260
1500
-3.0
PIN,MAX
dBm
PD
PA
dBm
dBm
Signal Detect Hysteresis
PA - PD
dB
0.5
Parameters
Symbol
Unit
Min.
Condition
1310
1550
-23
-19
1360
1600
155M Rx
1.25G Rx
Max.
Remark
PIN,MIN-3
PIN,MIN-2
Typ.
Audio (Analog)
Analog Sample Rate
Faudio_a
Input level
output level
Input Impedance
Output Impedance
Ain
Aout
Vpp=3.3V/Analog
kHz
48
Vpp
Vpp
kΩ
Ω
0.56Vss
0.65
25
100
Audio(SPDIF)
Data Rate
TX
RX
Pulse Width Distortion
Δtw
Maximum Receivable Power
Minimum Receivable Power
Fiber Output Power
Center Emission Wavelength
Pmax
Pmin
Pf
λc
NRZ
NRZ
Mbps
Mbps
0.1
DC
6
6
Pulse Width = 67ns
Pulse Cycle = 134ns
CL = 10pF
ns
-15
15
dBm
dBm
dBm
nm
-14.5
15Mbps
15Mbps
Copyright © 2008, All rights reserved, Opticis Co., Ltd.
-4-
-24
-15
-21
650
12, Aug. 2008
M5-2A2 (Ver. 1.5)
www.opticis.com
Drawing of transmitter and receiver modules
Dimension [mm]
Transmitter
Receiver
Copyright © 2008, All rights reserved, Opticis Co., Ltd.
-5-
12, Aug. 2008
M5-2A2 (Ver. 1.5)
www.opticis.com
DVI Pin Description
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
Symbol
CH2CH2+
GND
Functional Description
TMDS Data Signal Channel 2 Negative
TMDS Data Signal Channel 2 Positive
TMDS Data Signal Channel 2 Shield
DDC Clock
DDC Data
N.C.
CH1CH1+
GND
DDC Clock line for DDC2B communication
DDC Data line for DDC2B communication
14
5V
15
GND
Hot plug
Detect
CH0CH0+
GND
5 V Input for Transmitter from Host
5 V Output for Monitor from Receiver
Ground
Signal is driven by monitor to enable the system to identify the presence
of a monitor
TMDS Data Signal Channel 0 Negative
TMDS Data Signal Channel 0 Positive
TMDS Data Signal Channel 0 Shield
GND
CLK+
CLK-
TMDS Clock Signal Shield
TMDS Clock Channel Positive
TMDS Clock Channel Negative
16
17
18
19
20
21
22
23
24
TMDS Data Signal Channel 1 Negative
TMDS Data Signal Channel 1 Positive
TMDS Data Signal Channel 1 Shield
Note: Channels 3, 4 and 5 dual-link data signal pins are not used
RS232C Pin Description
Pin
1
2
3
4
5
6
7
8
9
Symbol
Received Line
Signal Detector
RD
TD
Data Terminal
Ready
GND
Data Set Ready
Request To Send
Clear To Send
NC
Functional Description
Connected with Pin4 & Pin6 in module
Data Receive: Uplink  Downlink
Data Transmit: Uplink  Downlink
Connected with Pin1 & Pin6 in module
Signal Ground
Connected with Pin1 & Pin4 in module
Connected with Pin8 in module
Connected with Pin7 in module
Connection tips:
1) Connection of PC-to-PC: Cross connection of pins 2 and 3 between two PCs.
2) Connection of PC-to-Device: Straight connection of pin 2:2 and pin 3:3
Copyright © 2008, All rights reserved, Opticis Co., Ltd.
-6-
12, Aug. 2008
M5-2A2 (Ver. 1.5)
www.opticis.com
Reliability Test
Opticis utilizes three types of test criteria for a reduction of variability and a continuous improvement of
the process by its FEMA (Failure Mode and Effective Analysis) program.
1) Mechanical test (vibration, shock)
2) Temperature & humidity tests
3) EMC test (FCC class A and CE Verification)
Mechanical and Temperature & Humidity Test Data
Heading
Operating
Test
Storage
Test
Test
Operating at each
Temperature
(See Note)
Duration
Sample
Failure
Size
30 Min
* 0 ~ 50 °C
(Each
(Interval: 10 °C)
n =3
0
Temperature)
Remarks
Note: Visual Test on the
Display
Low Temperature
* TS = -30 °C
96 HR
n=3
0
1. TS: Storage Temperature
High Temperature
* TS = 70 °C
96 HR
n=3
0
2. RH: Relative Humidity
High Humidity
* TS: 60 °C
96 HR
n=3
0
High Temperature
* RH: 90%
-
n=2
0
-
n=2
0
Mechanical
Shock
Mechanical
Test
Conditions
* Pulse: 11 ms
* Peak level: 30 g
* Shock pulse: 3 times/Axis
* Peak acceleration: 20 g
Mechanical
* Frequency: 20~2000 ㎐
Vibration
* Sweep time: 30 Minutes
* 4 Times/Axis
Copyright © 2008, All rights reserved, Opticis Co., Ltd.
-7-
12, Aug. 2008
M5-2A2 (Ver. 1.5)
www.opticis.com
EMC Test Data
1) EMI: Meet FCC class A (ICES-003) and CE class A
STANDARDS
EN 55 022 (CISPR22)
CE (Conducted Emission) &
FCC; PART 15 SUBPART B
RE (Radiated Emission)
EN 61000-3-2 (IEC 61000-3-2)
Harmonics
EN 61000-3-3 (IEC 61000-3-3)
Flickers
CONDITIONS
Meet Class A
Meet Class A
Meet Class A
2) EMS: Meet CE standards (EN 55024) and CISPR24 equivalents
EN 61 000-4-2:1995
EN 61 000-4-3:1996
EN 61 000-4-4:1995
EN 61 000-4-5:1995
EN 61 000-4-6:1996
EN 61 000-4-11:1994
STANDARDS
Electrostatic Discharge Immunity
(Air: 8kv, Contact: 4kv)
Radiated RF E-Field (80~1000 MHz)
3V/m (AM 80%, 1kHz)
Fast Transients (5kHz, 60Seconds)
Surge Transients
Conducted Susceptibility (CS)
Radiated Susceptibility (RS)
Voltage Dips, Interruption & Variation
Copyright © 2008, All rights reserved, Opticis Co., Ltd.
-8-
CONDITIONS
Meet Criterion A
Meet Criterion A
Meet Criterion A
Meet Criterion A
Meet Criterion A
Meet Criterion A and C
12, Aug. 2008