Package Outline Drawing (POD)

Hermetic Packages for Integrated Circuits
Metal Can Packages (Can)
T10.B MIL-STD-1835 MACY1-X10 (A2)
REFERENCE PLANE
A
10 LEAD METAL CAN PACKAGE
e1
L
L2
L1
INCHES
ØD2
4.19
4.70
-
0.019
0.41
0.48
1
Øb1
0.016
0.021
0.41
0.53
1
N
Øb2
0.016
0.024
0.41
0.61
-
ØD
0.335
0.375
8.51
9.52
-
α
ØD1
0.305
0.335
7.75
8.51
-
ØD2
0.110
0.160
2.79
4.06
-
k
C
L
e
BASE AND
SEATING PLANE
Q
BASE METAL
Øb1
LEAD FINISH
Øb2
SECTION A-A
NOTES:
1. (All leads) Øb applies between L1 and L2. Øb1 applies between
L2 and 0.500 from the reference plane. Diameter is uncontrolled
in L1 and beyond 0.500 from the reference plane.
2. Measured from maximum diameter of the product.
3. α is the basic spacing from the centerline of the tab to terminal 1
and β is the basic spacing of each lead or lead position (N -1
places) from α, looking at the bottom of the package.
4. N is the maximum number of terminal positions.
5. Dimensioning and tolerancing per ANSI Y14.5M - 1982.
6. Controlling dimension: INCH.
65
NOTES
0.185
1
β
MAX
0.016
k1
Øb1
Øb
MIN
0.165
Øe
F
MAX
A
A
2
MIN
Øb
A
ØD ØD1
MILLIMETERS
SYMBOL
0.230 BSC
e1
0.115 BSC
F
-
0.040
5.84 BSC
-
2.92 BSC
-
-
1.02
-
k
0.027
0.034
0.69
0.86
-
k1
0.027
0.045
0.69
1.14
2
L
0.500
0.750
12.70
19.05
1
L1
-
0.050
1.27
1
-
L2
0.250
-
6.35
-
1
Q
0.010
0.045
0.25
1.14
-
α
36o
BSC
3
β
36o BSC
36o BSC
3
N
10
10
BSC
36o
4
Rev. 0 5/18/94